Field noise measurement in the huge industrial plants for accurate prediction

Similar documents
WindPRO version Sep 2011 Printed/Page :22 / 1. DECIBEL - Main Result. Calculation: Bielice Park. WTGs. Sound Level.

WindPRO version Sep 2011 Printed/Page :29 / 1. DECIBEL - Main Result. Calculation: Bielice Park. WTGs. Sound Level.

WindPRO version joulu 2012 Printed/Page :22 / 1. DECIBEL - Main Result

Environmental Noise Propagation

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times

Pre-Construction Sound Study. Velco Jay Substation DRAFT. January 2011 D A T A AN AL Y S IS S OL U T I ON S

Please refer to the figure on the following page which shows the relationship between sound fields.

WindPRO version Sep 2011 Project:

Investigation of Noise Spectrum Characteristics for an Evaluation of Railway Noise Barriers

METHODOLOGY FOR VERIFICATION OF SOFTWARE FOR NOISE ATTENUATION CALCULATION ACCORDING TO ISO STANDARD

Pipeline Blowdown Noise Levels

IS INTERNATIONAL STANDARD. Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation

Description: Valmistaja takaa mallinnuksessa käytetyn melun kokonaistason. Valmistajan takuu ei koske oktaavi- tai tessioktaavikaistoja.

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia

SILVERSTONE CIRCUIT MASTERPLAN APPENDIX H NOISE & VIBRATION

HARMONOISE: NOISE PREDICTIONS AND THE NEW EUROPEAN HARMONISED PREDICTION MODEL

Appendix D: Preliminary Noise Evaluation

Field experiment on ground-to-ground sound propagation from a directional source

Problems with the INM: Part 2 Atmospheric Attenuation

PREDICTING SOUND LEVELS BEHIND BUILDINGS - HOW MANY REFLECTIONS SHOULD I USE? Apex Acoustics Ltd, Gateshead, UK

The Research on Application of Cadna/A Software in Noise Prediction of Urban Substation

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Sound Reflection from a Motorway Barrier

The criterion of noise attenuation by hedges

91 Street Earth Berm Removal in Edmonton, Alberta

Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2

WesPac Pittsburg Energy Infrastructure Project. Noise Assessment Report

WIND TURBINE ACOUSTICS - a sneak preview on research topics- Dr. Andree Altmikus ENERCON Research & Development

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1

An experimental evaluation of a new approach to aircraft noise modelling

A realistic environmental approach for the construction of a perceptual typology of industrial noise sources

Road Noise Auralisation for Planning New Roads

ISO INTERNATIONAL STANDARD

International Journal of Technical Research and Applications e-issn: , Volume 3, Issue 4 (July-August 2015), PP.

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

Research Article Study on Noise Prediction Model and Control Schemes for Substation

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 5 th Edition / December 2010

The following is the summary of Keane Acoustics community mechanical noise study for the City of St. Petersburg.

Roche Ireland Limited

Application of Graphical User Interface of Matlab for Opencast Mining Machinery Noise Prediction

Validation and evolution of the road traffic noise prediction model NMPB-96 - Part 1: Comparison between calculation and measurement results

MEASURING SOUND INSULATION OF BUILDING FAÇADES: INTERFERENCE EFFECTS, AND REPRODUCIBILITY

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

noise is generally defined as unwanted sound

AMERICAN UNIVERSITY EAST CAMPUS DEVELOPMENT WASHINGTON, D.C. Environmental Noise Study. Project Number

FINAL REPORT. On Project Supplemental Guidance on the Application of FHWA s Traffic Noise Model (TNM) APPENDIX L Tunnel Openings

Performance of Roadside Sound Barriers with Sound Absorbing Edges

RECOMMENDATION ITU-R F.1404*

Reducing the influence of microphone errors on in- situ ground impedance measurements

The Harmonoise noise prediction algorithm: Validation and use under Australian conditions

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007

Bancroft & Piedmont Cellular Facility

Behrens & Associates Environmental Noise Control, Inc.

PERMANENT AND SEMI-PERMANENT NOISE MONITORING - FIRST RESULTS IN THE CITY OF NIS

A Road Traffic Noise Evaluation System Considering A Stereoscopic Sound Field UsingVirtual Reality Technology

Temperature and Water Vapor Density Effects On Weather Satellite

ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Acoustic Intensity Mapping at a Natural Gas Compression Station

WITHIN GENERATOR APPLICATIONS

Tonal sound from onshore drilling rig top drive unit

Acoustics Technical Note

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 4 th Edition / December 2008

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0

Southwest Anthony Henday Drive At Wedgewood Heights Residential Neighborhood in Edmonton, AB

NOISE IMPACT ASSESSMENT 2016

A STUDY ON THE CHARACTERISTICS AND PREDICTION METHOD OF NOISE FROM CONCRETE RAILWAY BRIDGE

Silent Transformers to Help Consolidated Edison Meet New York City s Ultrastrict Noise Ordinances

Appendix 8. Draft Post Construction Noise Monitoring Protocol

Effect of wind speed and wind direction on amplitude modulation of wind turbine noise. Thileepan PAULRAJ1; Petri VÄLISUO2;

Viterra's Pacific Terminal Dust Control & Ship Loader Upgrades Community Noise Asessment Report

APPENDIX A SOUND PROPAGATION THEORY & METHODOLOGIES

Urban sound energy reduction by means of sound barriers

Environmental Noise Survey For. Vista Coal Project. Prepared for: Coalspur Mines Ltd. Prepared by: S. Bilawchuk, M.Sc., P.Eng.

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0

Underwater Noise Levels

NOISE IMPACT STUDY FOR THE SOUTH PIER IMPROVEMENT PROJECT BROOKLYN, NEW YORK. April 2008

Acoustic Assessment Report Silvercreek Solar Park Transformer Station Aylmer, Ontario

Experimental Investigation on the Effect of Origami Geometry on the Acoustic Characteristics

Assessment of rail noise based on generic shape of the pass-by time history

Optimizing localization of noise monitoring stations for the purpose of inverse engineering applications

REVISED NOISE IMPACT STUDY

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01

Acoustic Calibration Service in Automobile Field at NIM, China

Appendix N. Preliminary Noise Assessment Technical Memorandum

Offaly County Council

Emergency Siren Sound Propagation and Coverage Optimization Analysis

Acoustic effects of platform screen doors in underground stations

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

TO Derek Holmes BURNCO Rock Products Ltd CC FROM Zhaohui Yu, Virgini Senden

Roche Ireland Limited

January 7, Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C

Noise attenuation directly under the flight path in varying atmospheric conditions

Noise Mitigation Study Pilot Program Summary Report Contract No

Microphone calibration service for airborne ultrasound

ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE

NOISE FROM GEOTHERMAL DRILLING

The spatial structure of an acoustic wave propagating through a layer with high sound speed gradient

Fundamentals of Environmental Noise Monitoring CENAC

Technical Note. Noise reducing properties of crash barriers. Performed for WillumTech. AV 1217/11 Project no.: A Page 1 of 19 incl.

Transcription:

Field noise measurement in the huge industrial plants for accurate prediction Takahiro HIDA 1 1 JGC Corporation, Japan ABSTRACT Proper noise controls of the industrial plants based on accurate noise prediction are important since noise from these plants will affect wide area both inside and outside of the plants. Also, occupational noise exposure is serious problem for workers of the plants. However, it is not easy to predict the noise propagation from the industrial plants such as refineries, petrochemical and gas treatment plants because of their huge amount of noise sources and complicated structures as obstacles and reflectors. At the inter-noise conferences in the last two years, we have presented our field data of noise propagation from industrial plants over the desert and sea with prediction results followed by ISO method. In this paper we focus on sound propagation in the near filed of the industrial plants. From our new field measurements, the effect of the noise sources, obstacles, and various field circumstances is discussed. We also try to improve the usage of the ISO calculation methods for each plant condition at design phase based on our measurement experience. Keywords: Industrial plant, Attenuation, Piling noise I-INCE Classification of Subjects Number(s): 55 1. INTRODUCTION For industrial plants, noise control is required for the purposes of protecting the hearing of personnel, reducing interference with speech and work and preventing annoyance to the neighboring communities. JGC has executed over 20,000 projects of industrial plants including oil and gas, petrochemical and general industrial fields. The plants usually contain many sources of noise, such as compressors, pumps, piping systems, flare stacks and fin fan coolers. Moreover, in recent years, plants have been becoming larger and noise emission has increased in power accordingly. Effective noise control for industrial plants depends upon proper noise prediction in design phase. ISO 9613 Acoustics -Attenuation of sound during propagation outdoors- [1] is most-used calculation method for the noise prediction of industrial plants. In this method, we have to decide several conditions such as, obstacles, temperature, relative humidity and ground factor for calculation models. Some of the factors are, however, not easy to determine because they are vary by each site. Therefore we need to estimate the factors supported by plentiful noise measurements. At last two inter-noise [2][3], we introduced our measurement experience of plant noise attenuation over the desert and sea where there are no obstacles, and we clarified the practical ground factors of each condition. In this paper we will introduce our measurement results of plant noise attenuation across the areas including the fields with some obstacles. Noise attenuations on fields of no obstacles and of some obstacles are compared with calculation by ISO 9613-2 where the field conditions are coordinated with the conditions of measurement as far as possible. We will also present measurement result of piling noise on construction phase and evaluate their attenuation in residential area where there are trees and houses. The piling noise is clear impact sound and we can identify their noise in residential area even though background noise exists. 1 hida.takahiro@jgc.com Inter-noise 2014 Page 1 of 6

Page 2 of 6 Inter-noise 2014 2. PARAMETERS REQUIRED FOR NOISE PREDICTION BY ISO 9613-2 Noise Prediction of industrial plants is often calculated using ISO 9613-2. The ISO 9613-2 requires many parameters for calculation, see equation (1). Some of the parameters are, however, difficult to obtain without field measurement on certain site. L p L D A (1) w C A = Adiv + Aatm + Agr + Abar + Amisc (2) Where, Lp: the sound presser level (SPL)at receiver point, Lw: the sound power level (PWL) of noise source, Dc: the directivity correction, A: the attenuation, Adiv: the attenuation due to geometrical divergence, Aatm: the attenuation due to atmospheric absorption, Agr: the attenuation due to the ground effect, Abar: the attenuation due to a barrier, Amisc: the attenuation due to miscellaneous other effects. Sound Pressure Level (SPL) at receiver location is calculated adopting Sound Power Level (PWL) of noise sources, their directivity and attenuation during propagation. PWL and directivity are obtained from equipment suppliers or estimated from past experience of similar equipment. Attenuation should be defined taking the field conditions into account. As shown in equation (2) the attenuation A has some elements, geometrical divergence, atmospheric absorption, ground effect, screening by obstacle and miscellaneous other effects. The attenuation due to atmospheric absorption is given by plant design condition. Ground abruption and screening of obstacles should be chosen carefully depending on the site situation. Also, ISO 9613-2 considers downwind condition, so we have no choice. Therefore, when noise sources information is obtained and design air temperature / humidity are given, models of ground and screening obstacles are key to accurate prediction in design phase. Such conditions for modeling must be estimated by noise measurements on similar plants to our target. We have measured many plants we constructed to improve our prediction calculation. 3. PLANT NOISE ATTENUATION OBSERVED ON THE SEVERAL FIELDS We would like to describe some overview of several measurement results to know the trend of the attenuation on several field conditions. In this section, three examples of noise attenuation from industrial plants are shown. Two no obstacles fields during propagation and the other is tank area adjacent to noisy plant units. 3.1 No Obstacle Conditions During Propagation Noise attenuation can be calculated in practicable level of accuracy by using ISO 9613-2 at no obstacle fields if the adequate parameters are obtained by measurement at similar condition site. The attenuation is prone to be large at the measurement depending on the conditions such as wind. As we presented at previous inter noise conferences, we measured attenuation of noise over the desert and the sea generated by industrial plants. Then we considered that the attenuation observed on the measurement can be replicated by using adequate ground factor on the calculation. Figure 1 shows the noise attenuation on the desert from boundary to 1500m outside of the gas treatment plant and calculated noise attenuation. The measurement was conducted in the morning, temperature was about 15 o C, relative humidity was about 20% and there was no wind to be considered. We could find that when the ground factor is 1, the attenuation could be well replicated. The attenuation obtained by measurement looks larger than calculation on the figure 1. One of the reasons is wind condition, there were no wind on the measurement but ISO considering downwind condition. Page 2 of 6 Inter-noise 2014

Inter-noise 2014 Page 3 of 6 Figure 1 Noise Attenuation on the desert by measurement and calculation Figure 2 shows the noise attenuation on the sea from boundary to 1000m outside of a petrochemical plant and calculated noise attenuation. The measurement was conducted in the morning, temperature was about 10 o C, relative humidity was about 70% and wind speed was 4m/s downwind. Contribution of traffic noise running parallel to measuring points was subtracted from the measurement data. We found that when the ground factor is 0.4, the attenuation was well replicated. In this case, the attenuation of measurement and calculation are almost same. It may be because the measurement condition and calculation condition including downwind presumption in ISO 9613-2 are similar; there were downwind condition on measurement and no obstacles in measurement. Slightly large attenuation is, however, observed on measurement compared with calculation. Figure 2 Noise Attenuation on the desert by measurement and calculation From above two examples, we may assume that if there are no obstacles, the attenuation is calculated in reliable level of accuracy by the ISO method. Also we found that large attenuation was observed on measurement compared with calculation in the case of no wind, and even downwind condition there was slight deference. 3.2 Tanks During Propagation In our experience, the noise attenuation through some obstacles seems to be larger than calculated based on ISO 9613-2. We conducted the measurement in the refinery plant and their adjacent tank area. The Inter-noise 2014 Page 3 of 6

Page 4 of 6 Inter-noise 2014 measurement was conducted in the afternoon, temperature of 35 o C, relative humidity of 50% and 2m/s downwind was observed. There are four small tanks and two lager tanks. The height of the small tanks is 12m and they located at 70m to 180m from noise generating plant units. The height of the large tanks is 20m and they located at 250m to 400m from the plant units. Figure 3 shows the measurement result and calculation based on ISO 9613-2. The PWL of plant used in the calculation was assumed by the measurement of equipment in the plant. Tanks are modeled as obstacles. Modeling and calculation were conducted by SoundPLAN the noise propagation software. The attenuation on measurement is obviously larger than on calculation at the small tanks area. At the back of large tanks noise levels become almost same level between measurement and calculation; the levels are influenced by background noise from other units. Therefore, unfortunately no idea can be derived from large tanks area. Figure 3 Noise Attenuation on Tanks We can find that it is difficult to predict accurate attenuation around obstacles. In this case, wind condition was downwind as ISO supposed and parameters are selected to consistent between calculation and measurement conditions. There was, however, obvious large attenuation at the obstacles area. Therefore, accumulating an adequate amount of measurement experience is important to accurate prediction. 4. PILING NOISE ATTENUATION MEASUREMENT ON RESIDENTIAL AREA In section 3, we presented the attenuation of plant noise on several sound propagation conditions. We can use these data for next plant which has similar condition. On the other hand, we have noise measurement for the target site before detail design is fixed when the nearby residential area noise was supposed to be sensitive. In this section, we introduce one of our measurement results during early construction phase. We measured noise levels of piling at around the piling machine and at adjacent residential area in order to know the propagation property from plant site to neighbor residential area. There are trees or rice field between the plant site and the village, so we observed different type of attenuation properties. Piling noise is impact sound and it is clear to distinguish its noise levels at each location. Table 1 shows measured noise levels around the piling machine to obtain its PWL. The PWL of piling noise was estimated by measured at 15m, 50m and 100m from the machine. The impact high of piling hammer was at around 10m, thus we used directivity factor Q = 1 for measurement point at 15m from the machine and Q = 2 for measurement points at 50m and 100m from the machine in calculation of PWL from SPL and distances. As a result, we obtained PWL of this machine as135dba by averaging out of three points. Page 4 of 6 Inter-noise 2014

Inter-noise 2014 Page 5 of 6 Table 1 Measured noise level of piling machine on construction site to estimate its PWL Distance from Piling machine Measured SPL Directivity factor Calculated PWL [m] [dba] Q [dba] 15 101 1 136 50 93 2 135 100 86 2 134 Table 2 shows the measurement results of each location of residential area. The measurement was conducted in the morning, temperature was about 35 o C, relative humidity was about 60% and wind speed was 2m/s downwind. Visibility of each location to piling machines are tentatively classfied as 0 to 4, 0 is completely clear view and 4 is completely blind, example images are shown in figure 4. Calculation was conducted based on ISO 9613-2 in accordance with the site condition but not including any obstacles. We use 135dBA as PWL from piling machine measurement mentioned above. We can find clear relation between visibility and differences of calculation and measurement. When the visibility is 1, difference is 0 1.5 db. When the visibility is 2, difference is 7 8.5 db. When the visibility is 4, difference is 11.5dB. By using this information, we can consider the attenuation of each pass depending upon their visibility at each point. Also we can incorporate the obstacles in an appropriate way into calculation modeling for plant noise prediction at design phase. No. Table 2 Measured and calculated piling noise at various points in residential area Distance from Piling machine Measured SPL Calculated SPL not including any obstacles Difference of Measured and Calc. Visibility 0: completely clear ~ 4: completely blind [m] [dba] [dba] [dba] 1 715 52 60.5 8.5 2 2 800 58 59.3 1.3 1 3 920 50 57.3 7.3 2 4 950 57 56.9-0.1 1 5 1140 54 54.7 0.7 1 6 1150 43 54.5 11.5 4 Visibility:1 Visibility:2 Visibility:4 Figure 4 Examples of visibility indicators Modeling of residential area is difficult because the obstacles are varied at each location, but if the plant is near the residential area, accurate prediction is required. Therefore, this kind of measurements before detail design of the plants is effectual. 5. CONCLUSIONS AND FUTURE WORKS Two plant noise measurement results of no obstacle sites, on the desert and sea, were introduced and the attenuation properties were compared with calculation based on ISO 9613-2. It was found that we can obtain good estimation from calculation by using appropriate ground factor. ISO 9613-2 presupposes downwind condition, so the measurement at downwind condition was good with calculation but there was slightly large attenuation. Also a plant noise measurement result of the site Inter-noise 2014 Page 5 of 6

Page 6 of 6 Inter-noise 2014 where there are obstacles was introduced and we found that the attenuation on the measurement was larger than calculated one. We also introduced the measurement of piling noise at residential area. We obtained attenuation level of each pass of this site by comparing with visibility due to trees and houses. These attenuation levels obtained by measurement improve our noise model in designing the plant on this site. For piling noise measurement, we measured many location and same location at some days. We would like to analyze these measurement results by each octave band, meteorological conditions and land use to understand detail effects of such factors. REFERENCES 1. ISO9613-2:1996, Acoustics Attenuation of sound during propagation outdoors Part2: General method of calculation. 2. T. Hida, The latest acoustic engineering of industrial plants, Proceedings of INTER-NOISE 2012, 512 (2012). 3. T. Hida, Open area field measurements of industrial plants noise, Proceedings of INTER-NOISE 2013, 632 (2013). Page 6 of 6 Inter-noise 2014