EMC Test Facility Sale

Similar documents
We re In The Business Of Making Your Life Easier

Semi Anechoic Chamber (SAC)

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

Normalized Site Attenuation Test Report

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

ACCREDITED LABORATORY. LIBERTY LABS, INC. Kimballton, IA for technical competence in the field of Calibration

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

E MC Ane c hoi c Chambers

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

AMPLIFIER RESEARCH... APPLICATION NOTE: 23

Model AS08010, M1 AR System 10kHz 8GHz

AMPLIFIER RESEARCH... APPLICATION NOTE: 20

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

YRS01 York Reference Source

Specification for Conducted Emission Test

EMC LAB EQUIPMENT CALIBRATION SCHEDULER

SAC-10 Plus Triton Class

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

AMPLIFIER RESEARCH... APPLICATION NOTE: 19

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Test and Measurement for EMC

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

LS200 TEST DATA IEC61000 SERIES

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

EMC Precompliance Systems and Accessories Catalog

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Failing EMC testing? > 50% of products fail EMC testing first time around

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Content. Report No. SH Page 2 of 22

TECHNICAL REQUIREMENTS

EMC VERIFICATION SUMMARY Report No.: SZHH

Advanced Test Equipment Rentals ATEC (2832) CNE III Comparison Noise Emitter

EMC TEST REPORT. according to

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

EMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations

Model BiConiLog Antenna. User Manual

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

Model AS18071, M1, M2 AR System 10kHz 18GHz

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

Test Centre Facilities Regulatory Test Lab

Methods for Testing Impulse Noise Tolerance

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

CE EMC Test Certification

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

MIL-STD 461F Results for M&A Technology Companion epad Computer

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

CE TEST CERTIFICATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

CE TEST CERTIFICATION

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Communication Certification Laboratory

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

ETS Lindgren Anechoic Chamber

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

Test Report. Prepared for: Technologic Systems, Inc. Model: TS Description: Embedded Computer Board. Serial Number: N/A. FCC Part 15B Class A

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

Schlöder GmbH - EMC Test and Measurement Systems Model #

Electromagnetic Compatibility

Emerging Standards for EMC Emissions & Immunity

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. TOKIN EMC ENGINEERING CO., LTD Hanashimashinden, Tsukuba-shi, Ibaraki Japan

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Advanced Test Equipment Rentals ATEC (2832)

EMC TEST REPORT For Prokits Industries Co., Ltd.

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

FCC Test Report. Report No.: AGC FE08 MODEL NAME : TH 9800,TH 9800D,TH 7800,TH 7900 CLIENT : TYT ELECTRONICS CO., LTD

EMC Back to Basics. Matthew Carter EMC Product Support Engineer Agilent Technologies Inc. April 16, 2014

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

TEST REPORT. Table of Contents

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

RF Conducted Immunity and Automotive Transient Generator Test Systems

Test Report According to EN V1.9.2; EN V Starcom GPS Systems Ltd.

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com

Test Instrumentation Range Overview

CENTRE OF TESTING SERVICE INTERNATIONAL

Trees, vegetation, buildings etc.

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

TEST REPORT of the accredited test laboratory

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

Transcription:

EMC Test Facility Sale Radiated Emissions Pre-Compliance Conducted Emissions Full-Compliance Radiated & Conducted Immunity Full-Compliance 1

Please find an information pack attached for an EMC test facility. Equipment Included in Package Compact semi-anechoic chamber (Panashield Model 1024 compact chamber) for emissions precompliance and radiated immunity full-compliance testing. Biconical & Biconilog antennas covering the frequency range 20 MHz to 6 GHz. Conducted emissions equipment. ESD: Haefely Onyx 16 kv simulator. EFT/Burst: Haefley 1ph/3ph EFT generator, several CDNs, capacitive clamp and verification equipment. Surge: Haefely 1ph/3ph Surge generator and CDNs. Conducted immunity: Signal generator, RF power amplifier, EM clamp, current probe and calibration jig to achieve 10 V/, across 150 khz to 80 MHz. Radiated immunity: signal generator, power amplifiers, power meter, field probe and automation control to achieve 10 V/m across 80 MHz 1 GHz. All equipment was purchased new in 2012 and has been very lightly used (mint condition). Test facility offered at $295k USD. Please see the following pages for further details. If you have any questions, please call me on 250-898-4567 or email me at andy@emcfastpass.com Best regards, Andy Eadie Owner, EMC FastPass. 2

Table of Contents Chamber Details... 4 History... 4 Dimensions... 4 Description... 5 Power filters... 5 Absorber... 5 Performance... 6 Guarantees... 6 Included Test Equipment... 7 Equipment Pictures... 8 Radiated Emissions... 8 Conducted Emissions... 9 Radiated Immunity... 10 Conducted Immunity... 12 ESD... 13 EFT... 13 Surge... 14 Logistics... 16 Location... 16 Packaging... 16 Shipping... 16 Taxes/Import Fees... 16 Installation... 16 3

Chamber Details History The chamber and all equipment were factory installed new in 2012. The facility has been lightly used since that time by one manufacturer. It was professionally dismantled and packaged in Feb 2018. Dimensions Exterior dimensions: Door dimensions: Approx. 23 11 long x 10 10 wide x 10 10 high. 4 wide x 7 high. Drawings (full construction drawings available): 4

Description The Panashield Model 1024 Compact 3M Chamber is designed for EMC assessment for full compliance radiated immunity testing to EN61000-4-3 and pre-compliant radiated emission measurements for EN5022, FCC Part 15 Class B, CISPR 22 and ANSI C63.4. It is constructed as a semi-anechoic chamber using an advanced hybrid absorber technology to provide performance from 30 MHz to 18 GHz. Compact chambers are a common solution for manufacturers who need to meet the international and domestic EMC standards. They are cost effective relative to a full 3 Meter chamber, and provide for a high degree of performance certainty before sending product to an independent test lab for certification. With a Panashield Model 1024, manufacturers can reduce product development cycles and costs associated with the third party test services. Power filters 5 x high quality power filters included. Absorber Absorber treatment consists of full coverage of ferrite tiles, and also partial coverage with low-profile, fire-proof HYB-NF-12 hybrid absorber. Floor coverage consists of removable ferrite panels with a smaller patch of HYB-NF-12 Hybrid for performance to IEC 61000-4-3 to 6 GHz. White absorbing wedges are included as shown in the chamber picture on the front page and the construction drawings. The chamber is specified for measurements up to 18 GHz. 5

Performance NSA report from the original installation available. Sample plots below: Guarantees Due to the nature of chamber construction, it is not possible to offer performance guarantees. Shielding effectiveness and measurement accuracy are dependent on the correct assembly of a chamber so we recommend the use of experienced chamber installers to maximize the shielding effectiveness upon reassembly. 6

Included Test Equipment Manufacturer Model Description Amplifier Research EM10123 Injection Clamp 10 khz-1 GHz Fischer Custom Comm. F-2031-23mm-CF-1 EM10123 Injection Clamp Cal Fixture Part 3 of 3 Amplifier Research EM10123CF EM10123 Injection Clamp Cal Fixture Part 3 of 3 Amplifier Research AF06250 250W 6 db attenuator Amplifier Research AF20050 50W 20 db attenuator Amplifier Research AF10050 50W 10 db attenuator Amplifier Research BP00250 Current Probe 1kHz-250MHz (monitor probe) Agilent Technologies N9010A Signal Analyzer-EXA series 3.6 GHz, opts 503, B25, EA3, EMC, P03 Amplifier Research SG1200 Signal Generator 9 khz-1.2 GHz Amplifier Research PM2003 Power Meter 10 khz-40 GHz Amplifier Research SC1000M RF Switch Controller Amplifier Research 75A250AM1 RF Amplifier 10kHz-250MHz Amplifier Research DC2600A Dual Directional Coupler-75A250M1 amp Amplifier Research PH2000 RF Power Head Amplifier Research TL50050 RF Load Amplifier Research CD20032 DC Power Line CDN Amplifier Research CDN S9 Signal Line CDN Amplifier Research CD50032 3 Phase Power Line CDN Amplifier Research CD40032 3 Phase Power Line CDN Amplifier Research CD30032 Power Line CDN Amplifier Research 150W1000M3 RF Amplifier 80MHz-1000MHz Amplifier Research DC6080A Dual Directional Coupler-150W1000M3 amp Amplifier Research FM7004 RF Field Monitor Amplifier Research FI7000 Laser Probe Interface Amplifier Research Laser Probe Tripod Amplifier Research ATR80M6GM4 Emissions/RF Immunity Antenna 80MHz-6GHz Amplifier Research TP1000B Antenna Tripod Amplifier Research FL7006 Laser Powered Field Probe Haefely Test AG PEFT4010 EFT Generator Haefely Test AG IP4A Capacitive Coupling Clamp Haefely Test AG FP-EFT 32M 3 Phase Coupler Decoupler Network Haefely Test AG PSURGE4010 Surge Generator Haefely Test AG FP-Surge 32.1 3 Phase Coupler Decoupler Network Haefely Test AG ONYX16 ESD Simulator 16 kv ETS-Lindgren 3104C Biconical Antenna 20MHz-300MHz Amplifier Research IN54025 3 Phase Line Impedance Stabilization Network Tekbox TBOH01, TBLC08 DC (CISPR 25) and AC (CISPR 16) LISNs EMC Partner VERI1K EFT-1520 1000 Ohm 60 db attenuator EMC Partner VERI50 EFT-1524 50 Ohm 54 db attenuator EMC Partner VERI-CP-EFT-1512 EFT Transducer Plate 7

Equipment Pictures Radiated Emissions Antenna Two antennas are used to cover the frequency range of interest. ETS-Lindgren 3104C Biconical Antenna 20MHz-300MHz Amplifier Research ATR80M6GM4 Emissions/RF Immunity Antenna 80MHz-6GHz Analyzer Agilent Technologies N9010A Signal Analyzer-EXA series 3.6 GHz, opts 503, B25, EA3, EMC, P03 Automation Software Radiated emissions testing is undertaken using the software EMCWare from Amplifier Research. (Host computer not included) USB to GPIB adaptor included. 8

Conducted Emissions In conjunction with the spectrum analyzer, the following equipment allows measurement of conducted emissions. LISNs Amplifier Research IN54025 3-Phase Line Impedance Stabilization Network (480V, 32A max) Tekbox TBOH01 DC (CISPR 25) LISN (60V, 10A mas) Tekbox TBLC08 AC (CISPR 16) LISN (250V, 8A max) 9

Radiated Immunity The chamber and support equipment allow for full-compliance radiated immunity testing in accordance with EN/IEC61000-4-3 (or similar). Antenna Amplifier Research ATR80M6GM4 RF Immunity Antenna 80MHz-6GHz Laser Powered Field Probe & Monitor Amplifier Research FM7004 RF Field Monitor Amplifier Research FI7000 Laser Probe Interface Amplifier Research Laser Probe Tripod 10

Signal Generator, Power Amplifiers & Controller The radiated emissions test setup includes an RF switch controller that speeds up test time by automatically switching between RF amplifiers. This automated system is controlled by the EMCWare software from Amplifier Research. Using the included amplifiers, a field strength of 10 V/m can be achieved over the frequency range 80 MHz 1 GHz. Amplifier Research SG1200 Signal Generator 9 khz-1.2 GHz Amplifier Research PM2003 Power Meter 10 khz-40 GHz Amplifier Research SC1000M RF Switch Controller Amplifier Research PH2000 RF Power Head Amplifier Research 150W1000M3 RF Amplifier 80MHz-1000MHz Amplifier Research DC6080A Dual Directional Coupler-150W1000M3 amp Laser field probe monitor RF power meter 10 khz 40 GHz RF power head Signal generator 9 khz 1.2 GHz Switch Controller RF power amp 80 MHz 1 GHz 150W RF power amp 10 khz 250 MHz 75W 11

TEM Cell To accommodate other standards that demand testing to higher field strengths, a TEM cell is included. This allows for much higher field strengths to be generated for a given amplifier output power. The TEM cell should be used within the chamber to avoid breaking regulatory emission limits. Length: 1038 mm Width: 501 mm Height: 305 mm Septum height: 150 mm Conducted Immunity Conducted immunity testing according to EN/IEC61000-4-6 (or similar equivalents) can be performed with the following equipment. Clamps/Probes and Accessories Amplifier Research EM10123 Injection Clamp 10 khz-1 GHz Fischer Custom Comm. F-2031-23mm-CF-1 EM10123 Injection Clamp Cal Fixture Part 3 of 3 Amplifier Research EM10123CF EM10123 Injection Clamp Cal Fixture Part 3 of 3 Amplifier Research BP00250 Current Probe 1kHz-250MHz (monitor probe) 12

ESD Full-compliance ESD testing in accordance with EN/IEC61000-4-2 (or similar) can be performed using the equipment below. Horizontal coupling plane also included. ESD Simulator Haefely Test AG ONYX16 ESD Simulator 16 kv EFT The Haefely PEFT 4010 is a complete stand-alone EFT/Burst Generator designed to meet the requirements of IEC/EN 61000-4-4 edition 1 & 2. It covers a voltage range from 100V to 4.8kV and has an integrated 16A single phase CDN. The additional 3-phase CDN, capacitive coupling clamp and verification kit add to the capability. EFT/Burst Generator Haefely Test AG PEFT4010 EFT Generator Haefely Test AG FP-EFT 32M 3 Phase Coupler Decoupler Network EMC Partner VERI1K EFT-1520 1000 Ohm 60 db attenuator EMC Partner VERI50 EFT-1524 50 Ohm 54 db attenuator EMC Partner VERI-CP-EFT-1512 EFT Transducer Plate 13

Capacitive Coupling Clamp Haefely Test AG IP4A Capacitive Coupling Clamp Surge The PSURGE 4010 allows evaluation of the performance (full-compliance) of equipment when subject to high-energy disturbances on power and interconnection lines. This is a test solution for EN/IEC 61000-4- 5, EN/IEC 61000-6-1, and EN/IEC 61000-6-2 amongst many other standards. The additional 3-phase CDN allows for testing of 3-phase equipment. Surge Generator Haefely Test AG PSURGE4010 Surge Generator 3 Phase CDN Haefely Test AG FP-Surge 32.1 3 Phase Coupler Decoupler Network 14

Other CDNs 5 more standalone CDNs are included for additional test capability. Amplifier Research CD20032 DC Power Line CDN Amplifier Research CDN S9 Signal Line CDN Amplifier Research CD50032 3 Phase Power Line CDN Amplifier Research CD40032 3 Phase Power Line CDN Amplifier Research CD30032 Power Line CDN 15

Logistics Location The chamber and equipment are currently located in storage in Houston, Texas. Available for inspection upon request. Packaging The equipment was professionally crated and packaged. Ready to ship at short notice. Shipping Shipping costs are in addition to the sale price. A quote can be provided for shipping and insurance at time of purchase. Taxes/Import Fees Local taxes, import fees and tariffs may be applicable and will be calculated at time of sale once destination is known. Buyer is responsible for all applicable taxes, fees and tariffs. Installation An experienced chamber installer is recommended to assemble the chamber to ensure that shielding effectiveness and room performance is maintained. Pricing does not include installation. 16