FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Similar documents
CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CERTIFICATE OF COMPLIANCE

Fisher 646 Electro Pneumatic Transducer

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

Fisher 646 Electro-Pneumatic Transducers

IP26 Series Current to Pneumatic Converter

Fisher LCP100 Local Control Panel

Fisher 4200 Series Electronic Position Transmitters

JM Enclosure Dimensions (in mm)

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Intrinsic Safety Control Drawing

EN Series Installation Manual

Range Spring, Bias Spring, and Spring Retainer/ Spacer Selection for Fisher 3570 Pneumatic Valve Positioners

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.

Product manual wire programmable RTD transmitter

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

Power supply. Calibration. Surface finishing. Seal. Process connection

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

ESSENTIAL INSTRUCTIONS Read this page before proceeding!

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Certificate of Compliance

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

CERTIFICATE OF COMPLIANCE

PROline promag 53 Division 1

Fieldbus Solutions & Network Topologies. ISA Exhibition Toronto May 12, 2004

Title: INTRINSIC SAFETY MADE EASY

DPharp Differential Pressure and Pressure Transmitters

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO

COMMUNICATION NETWORKS

Loop Powered Indicator

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

ORIGINAL SIZE SYSTEM CONTROL DWG. FILE. ROSEMOUNT 2410 OrCADl. o o

LIQ_MAN_ABR_5081P-FF-FI/Rev. D January 2015

FM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10

Armstrong Intelligent Monitoring Installation and Operation Manual

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

YVP110 Advanced Valve Positioner

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Certificate of Conformity

ATEX Installation Drawings and Instructions

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Certificate of Compliance

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Product Manual wire HART transmitter

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

LIQ_MAN_ABR_5081T-HT/Rev. L January 2015

Customer Drawings Product Selection

User s Manual YOKOGAWA. Model PH202G (S) ph Transmitter. IM 12B6C3-E-E 12th Edition

AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

Model DY Vortex Flowmeter Model DYA Vortex Flow Converter Fieldbus Communication Type

Single-Channel Safety Barriers Series 9001

Safety Instructions Proline Promag 500

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

Safety Instructions Proline Promass 300

IECEx Certificate of Conformity Annexe

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

INSTRUCTION & SAFETY MANUAL

YTA610 and YTA710 Temperature Transmitter (Hardware)

Binary Output Series 9175

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

INTRINSICALLY SAFE DUPLEXER

MODEL LP35 LP SERIES LOW PROFILE INTRINSIC SAFETY INCREMENTAL ENCODER

Product Manual wire HART transmitter

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Operating Manual. isolate501

General Specifications

Rosemount 148 Temperature Transmitter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Isolators A3/1.

Instruction Manual LIQ_MAN_5081A-FF/rev.M January A. FouNdAtIoN Fieldbus two-wire Chlorine, dissolved oxygen, and ozone transmitter

User s Manual Flange Mounted Differential Pressure Transmitters EJX210A and EJA210E

Rosemount 148 Temperature Transmitter

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Safety Instructions Micropilot NMR81, NMR84

User s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438

Binary Output without Power Supply Series 9176

Emerson (Appleton Group ATX)

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Head mounted Temperature Transmitter TF02/TF02-Ex

Rosemount 248 Wireless Temperature Transmitter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

ProcessMaster, HygienicMaster FEX300, FEX500

Certificate of Conformity

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Transcription:

Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions for Safe Use and Installations in Hazardous Locations Certain nameplates may carry more than one approval, and each approval may have unique installation/wiring requirements and/or conditions of safe use. These special instructions for safe use are in addition to, and may override, the standard installation procedures. Special instructions are listed by approval type. Note This information supplements the nameplate markings affixed to the product and the DVC6200 Series quick start guide (D103556X012), available from your Emerson sales office or Local Business Partner, or at Fisher.com. Always refer to the nameplate itself to identify the appropriate certification. WARNING Failure to follow these conditions of safe use could result in personal injury or property damage from fire or explosion and area re classification. Explosion-proof, Dust-Ignition proof, Non-Incendive, Suitable for Use DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION Fieldbus, PROFIBUS) XP: Class I, Division 1, Groups B,C,D DIP: Class II, III, Division 1, Groups E,F,G NI: Class I, Division 2, Groups A,B,C,D S: Class II, III, Division 2, Groups F,G Class I Zone 1 AEx d IIC Class I Zone 2 Ex nc IIC T5 Ta = 80 C, T6 Ta = 75 C Type 4X, IP66 www.fisher.com

DVC6200 Digital Valve Controllers Instruction Manual Supplement DVC6215 Remote Mount XP: Class I, Division 1, Groups A,B,C,D DIP: Class II, III, Division 1, Groups E,F,G NI: Class I, Division 2, Groups A,B,C,D S: Class II, III, Division 2, Groups F,G Class I Zone 1 AEx d IIC Class I Zone 2 Ex na IIC T4 Ta = 125 C, T5 Ta = 90 C, T6 Ta = 75 C Type 4X, IP66 Intrinsically Safe and Nonincendive Field Wiring Intrinsic Safety IS Class I, II, III Division 1 Groups A,B,C,D,E,F,G Class I Zone 0 AEx ia IIC Class I Zone 2 AEx ic IIC Nonincendive Field Wiring NI Class I Division 2 Groups A,B,C,D Type 4X, IP66 Intrinsically safe or Nonincendive Field Wiring when connected per control drawing GE42819, as shown in the following figures DVC6200 HW2 and DVC6200 SIS Intrinsically Safe... figure 1 and 15 Intrinsically Safe or Nonincendive Field Wiring... figure 2 and 15 DVC6205, DVC6205 SIS, and DVC6215 Remote Mount Intrinsically Safe... figure 3 and 15 Intrinsically Safe or Nonincendive Field Wiring... figure 4 and 15 DVC6200f and DVC6200p Entity Fieldbus Loop: Intrinsically Safe... figure 5 and 15 Entity Fieldbus Loop: Intrinsically Safe or Nonincendive Field Wiring... figure 6 and 15 FISCO Installations: Intrinsically Safe... figure 7 and 15 FISCO Installations: Intrinsically Safe or Nonincendive Field Wiring... figure 8 and 15 DVC6205f, DVC6205p, and DVC6215 Remote Mount Entity Fieldbus Loop: Intrinsically Safe... figure 9 and 15 Entity Fieldbus Loop: Intrinsically Safe or Nonincendive Field Wiring... figure 10 and 15 FISCO Installations: Intrinsically Safe... figure 11 and 15 FISCO Installations: Intrinsically Safe or Nonincendive Field Wiring... figure 12 and 15 DVC6200 HW1 Intrinsically Safe... figure 13 and 15 Intrinsically Safe or Nonincendive Field Wiring... figure 14 and 15 Special Conditions of Safe Use When product is used with natural gas as the pneumatic medium, the maximum working pressure of the natural gas supply shall be limited to 10 bar (145 psi). When product is used with natural gas as the pneumatic medium the product shall not be permitted in a Class I, Division 2, Group A, B, C, D location without the proper venting installation per the manufacturer's instruction manual. The apparatus enclosure contains aluminum and is considered to constitute a potential risk of ignition by impact or friction. Care must be taken into account during installation and use to prevent impact or friction. Part of the enclosure is constructed from plastic. To prevent the risk of electrostatic sparking the plastic surface should only be cleaned with a damp cloth. 2

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 1. FM Loop Schematics FIELDVUE DVC6200 HW2 and DVC6200 SIS INTRINSICALLY SAFE DVC6200, DVC6200S (HW2 CONSTRUCTION) POWER MAY BE APPLIED TO EITHER THE LOOP TERMINALS OR OUTPUT TERMINALS OR TO BOTH SETS OF TERMINALS AT THE SAME TIME UNITS WITHOUT THE I/O PACKAGE WILL NOT HAVE OUTPUT TERMINALS AVAILABLE FOR CONNECTION ** Li = 0.15 mh WHEN THE AUX TERMINALS ARE NOT USED OR NOT PROVIDED LOOP TERMINALS ** **Imax = 130 ma **Pi = 1.0 W ** OUTPUT TERMINALS **Vmax = 28 VDC **Imax = 100 ma **Pi = 1.0 W **Li = 0.50 mh 1 NOTE 9 1 NOTE 7 BARRIER BARRIER WITH I/O PACKAGE T6 (Tamb) 61 C WITHOUT I/O PACKAGE T6 (Tamb) 74 C GE42819 Sheet 11, Rev. C 3

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 2. FM Loop Schematics FIELDVUE DVC6200 HW2 and DVC6200 SIS INTRINSICALLY SAFE OR NONINCENDIVE FIELD WIRING DVC6200, DVC6200S (HW2 CONSTRUCTION) POWER MAY BE APPLIED TO EITHER THE LOOP TERMINALS OR OUTPUT TERMINALS OR TO BOTH SETS OF TERMINALS AT THE SAME TIME UNITS WITHOUT THE I/O PACKAGE WILL NOT HAVE OUTPUT TERMINALS AVAILABLE FOR CONNECTION ** Li = 0.15 mh WHEN THE AUX TERMINALS ARE NOT USED OR NOT PROVIDED LOOP TERMINALS **Vmax = N/A **Imax = 130 ma **Pi = N/A ** OUTPUT TERMINALS 1 NOTE 7 BARRIER OR NONINCENDIVE CIRCUIT **Vmax = N/A **Imax = 100 ma **Pi = N/A **Li = 0.50 mh 1 NOTE 8 BARRIER OR NONINCENDIVE CIRCUIT WITH OR WITHOUT I/O PACKAGE T6 (Tamb) 75 C GE42819 Sheet 11, Rev. C 4

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 3. FM Loop Schematics FIELDVUE DVC6205, DVC6205 SIS, and DVC6215 INTRINSICALLY SAFE DVC6205 (HW2 CONSTRUCTION) WITH OR WITHOUT I/O PACKAGE DVC6215 Ci = 50 nf NOTE 1, 3 1 T4 (Tamb) 125 C T5 (Tamb) 95 C T6 (Tamb) 80 C REMOTE FIELD WIRING TERMINAL BOX REMOTE TERMINALS Voc = 30 VDC Isc = 21.2 ma Po = 160 mw Ca = 55 nf La = 78 mh FIELD WIRING TERMINAL BOX LOOP TERMINALS ** **Imax = 130 ma **Pi = 1.0 W ** OUTPUT TERMINALS **Vmax = 28 VDC **Imax = 100 ma **Pi = 1.0 W **Li = 0.50 mh NOTE 7 1 FM APPROVED BARRIER FM APPROVED BARRIER NOTE 9 1 WITH I/O PACKAGE T6 (Tamb) 61 C WITHOUT I/O PACKAGE T6 (Tamb) 74 C POWER MAY BE APPLIED TO EITHER THE LOOP TERMINALS OR OUTPUT TERMINALS OR TO BOTH SETS OF TERMINALS AT THE SAME TIME UNITS WITHOUT THE I/O PACKAGE WILL NOT HAVE OUTPUT TERMINALS AVAILABLE FOR CONNECTION ** Li = 0.15 mh WHEN THE AUX TERMINALS ARE NOT USED OR NOT PROVIDED GE42819 Sheet 12, Rev. C 5

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 4. FM Loop Schematics FIELDVUE DVC6205, DVC6205 SIS, and DVC6215 INTRINSICALLY SAFE OR NONINCENDIVE FIELD WIRING DVC6205 (HW2 CONSTRUCTION) WITH OR WITHOUT I/O PACKAGE DVC6215 Ci = 50 nf NOTE 1, 3 1 T4 (Tamb) 125 C T5 (Tamb) 95 C T6 (Tamb) 80 C REMOTE FIELD WIRING TERMINAL BOX REMOTE TERMINALS Voc = 30 VDC Isc = 21.2 ma Po = 160 mw Ca = 55 nf La = 78 mh FIELD WIRING TERMINAL BOX LOOP TERMINALS **Vmax = N/A **Imax = 130 ma **Pi = N/A ** OUTPUT TERMINALS **Vmax = N/A **Imax = 100 ma **Pi = N/A **Li = 0.50 mh NOTE 7 1 BARRIER OR NONINCENDIVE CIRCUIT BARRIER OR NONINCENDIVE CIRCUIT NOTE 8 1 WITH OR WITHOUT I/O PACKAGE T6 (Tamb) 75 C POWER MAY BE APPLIED TO EITHER THE LOOP TERMINALS OR OUTPUT TERMINALS OR TO BOTH SETS OF TERMINALS AT THE SAME TIME UNITS WITHOUT THE I/O PACKAGE WILL NOT HAVE OUTPUT TERMINALS AVAILABLE FOR CONNECTION ** Li = 0.15 mh WHEN THE AUX TERMINALS ARE NOT USED OR NOT PROVIDED GE42819 Sheet 12, Rev. C 6

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 5. FM Loop Schematics FIELDVUE DVC6200f and DVC6200p, Entity Fieldbus Loop INTRINSICALLY SAFE DVC6200F, DVC6200FS DVC6200P, DVC6200PS ENTITY DEVICE NOTE 1, 3 1 Vmax = 24 VDC Imax = 380 ma Ci = 5 nf Li = 0 mh 1 NOTE 9 1 NOTE 7 GE42819 Sheet 3, Rev. F T4 (Tamb) 80 C T5 (Tamb) 77 C T6 (Tamb) 62 C FM APPROVED BARRIER 1 NOTE 1, 3, 4, 5, 6 Figure 6. FM Loop Schematics FIELDVUE DVC6200f and DVC6200p, Entity Fieldbus Loop INTRINSICALLY SAFE OR NONINCENDIVE FIELD WIRING DVC6200F, DVC6200FS DVC6200P, DVC6200PS ENTITY DEVICE NOTE 1, 3 1 Imax = N/A Pi = N/A Ci = 5 nf Li = 0 mh 1 NOTE 8 GE42819 Sheet 3, Rev. F 1 NOTE 7 T6 (Tamb) 75 C BARRIER OR NONINCENDIVE CIRCUIT 1 NOTE 1, 3, 4, 5, 6 7

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 7. FM Loop Schematics FIELDVUE DVC6200f and DVC6200p, FISCO Installations INTRINSICALLY SAFE I.S. CL I,II,III DIV 2 GP ABCDEFG DVC6200F, DVC6200FS DVC6200P, DVC6200PS FISCO DEVICE FISCO FIELD DEVICE NOTE 2, 3 1 1 NOTE 9 FISCO TERMINATOR GE42819 Sheet 4, Rev. F T4 (Tamb) 80 C T5 (Tamb) 77 C T6 (Tamb) 62 C FISCO POWER SUPPLY (Ex ia IIC) 1 NOTE 2, 3, 4, 5, 6 Figure 8. FM Loop Schematics FIELDVUE DVC6200f and DVC6200p, FISCO Installations INTRINSICALLY SAFE OR NONINCENDIVE FIELD WIRING DVC6200F, DVC6200FS DVC6200P, DVC6200PS FISCO DEVICE FISCO FIELD DEVICE NOTE 2, 3 1 FISCO TERMINATOR GE42819 Sheet 4, Rev. F T6 (Tamb) 75 C FISCO POWER SUPPLY (Ex ic IIC minimum) 1 NOTE 2, 3, 4, 5, 6 8

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 9. FM Loop Schematics FIELDVUE DVC6205f, DVC6205p, and DVC6215, Entity Fieldbus Loop INTRINSICALLY SAFE ENTITY DEVICE NOTE 1, 3 1 DVC6215 Ci = 50 nf NOTE 1, 9 1 DVC6205f, DVC6205p Voc = 24 VDC Isc = 44 ma Po = 330 mw Ca = 121 nf La = 30 mh Vmax = 24 VDC Imax = 380 ma Ci = 5 nf Li = 0 mh NOTE 9 1 BARRIER NOTE 7 1 T4 (Tamb) 125 C T5 (Tamb) 95 C T6 (Tamb) 80 C T4 (Tamb) 80 C T5 (Tamb) 77 C T6 (Tamb) 62 C 1 NOTE 1, 3, 4, 5, 6 GE42819 Sheet 9, Rev. D Figure 10. FM Loop Schematics FIELDVUE DVC6205f, DVC6205p, and DVC6215, Entity Fieldbus Loop INTRINSICALLY SAFE OR NONINCENDIVE FIELD WIRING DVC6215 ENTITY DEVICE Ci = 50 nf NOTE 1, 3 NOTE 1 1 1 DVC6205f, DVC6205p Voc = 30 VDC Isc = 44 ma Po = 330 mw Ca = 121 nf La = 30 mh Imax = N/A Pi = N/A Ci = 5 nf Li = 0 mh NOTE 8 1 BARRIER OR NONINCENDIVE CIRCUIT NOTE 7 1 T4 (Tamb) 125 C T5 (Tamb) 95 C T6 (Tamb) 80 C T6 (Tamb) 75 C 1 NOTE 1, 3, 4, 5, 6 GE42819 Sheet 9, Rev. D 9

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 11. FM Loop Schematics FIELDVUE DVC6205f, DVC6205p, and DVC6215, FISCO Installations INTRINSICALLY SAFE FISCO DEVICE NOTE 2, 3 1 DVC6215 Ci = 50 nf NOTE 1, 9 1 DVC6205f, DVC6205p Voc = 17.75 VDC Isc = 44 ma Po = 330 mw Ca = 121 nf La = 30 mh FISCO FIELD DEVICE NOTE 9 1 FISCO TERMINATOR T4 (Tamb) 125 C T5 (Tamb) 95 C T6 (Tamb) 80 C T4 (Tamb) 80 C T5 (Tamb) 77 C T6 (Tamb) 62 C FISCO POWER SUPPLY (Ex ia IIC) 1 NOTE 2, 3, 4, 5, 6 GE42819 Sheet 10, Rev. D Figure 12. FM Loop Schematics FIELDVUE DVC6205f, DVC6205p, and DVC6215, FISCO Installations INTRINSICALLY SAFE OR NONINCENDIVE FIELD WIRING FISCO DEVICE NOTE 2, 3 1 DVC6215 Ci = 50 nf NOTE 1, 1 DVC6205f, DVC6205p Voc = 17.5 VDC Isc = 44 ma Po = 330 mw Ca = 121 nf La = 30 mh FISCO FIELD DEVICE FISCO POWER SUPPLY (Ex ic IIC minimum) FISCO TERMINATOR T4 (Tamb) 125 C T5 (Tamb) 95 C T6 (Tamb) 80 C T6 (Tamb) 75 C 1 NOTE 2, 3, 4, 5, 6 GE42819 Sheet 10, Rev. D 10

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 13. FM Loop Schematic FIELDVUE DVC6200 HW1 INTRINSICALLY SAFE I.S. CLASS I,II,III DIV 1 GP ABCDEFG DVC6200, DVC6200S 1 NOTE 9 Ci = 5 nf FM APPROVED BARRIER 1 NOTE 1, 3, 4, 5, 6 T6 (Tamb) 75 C 1 NOTE 7 GE42819 sheet 2, Rev. F Figure 14. FM Loop Schematic FIELDVUE DVC6200 HW1 INTRINSICALLY SAFE OR NONINCENDIVE FIELD WIRING DVC6200, DVC6200S 1 NOTE 8 Vmax = N/A Pi = N/A Ci = 5 nf T6 (Tamb) 75 C 1 NOTE 7 BARRIER OR NONINCENDIVE CIRCUIT 1 NOTE 1, 3, 4, 5, 6 GE42819 sheet 2, Rev. F 11

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 15. Notes for FM Loop Schematics THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO ASSOCIATED APPARATUS NOT SPECIFICALLY EXAMINED IN SUCH COMBINATION. THE CRITERIA FOR INTERCONNECTION IS THAT THE VOLTAGE (Vmax OR Ui), THE CURRENT (Imax OR Ii), AND THE POWER (Pmax or Pi) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Uo), AND THE CURRENT (Isc OR Io), AND THE POWER(Po) DEFINED BY THE ASSOCIATED APPARATUS. IN ADDITION, THE SUM OF THE MAX UNPROTECTED CAPACITANCE (Ci) AND MAX UNPROTECTED INDUCTANCE (Li), INCLUDING THE INTERCONNECTING CABLING CAPACITANCE (Ccable) AND CABLING INDUCTANCE (Lcable) MUST BE LESS THAN THE ALLOWABLE CAPACITANCE (Ca) AND INDUCTANCE (La) DEFINED BY THE ASSOCIATED APPARATUS. IF THE ABOVE CRITERIA IS MET, THEN THE COMBINATION MAY BE CONNECTED. Vmax or Ui Voc or Uo Imax or Ii Isc or Io Pmax or Pi Po Ci + Ccable Ca Li + Lcable La THE FISCO CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO ASSOCIATED APPARATUS NOT SPECIFICALLY EXAMINED IN SUCH COMBINATION. THE CRITERIA FOR THE INTERCONNECTION IS THAT THE VOLTAGE (Vmax OR Ui), CURRENT (Imax OR Ii), AND POWER (Pmax or Pi), WHICH AN INTRINSICALLY SAFE APPARATUS CAN RECEIVE AND REMAIN INTRINSICALLY SAFE, CONSIDERING FAULTS, MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Uo), CURRENT (Isc OR Io), AND POWER (Po) LEVELS WHICH CAN BE DELIVERED BY THE ASSOCIATED APPARATUS, CONSIDERING FAULTS AND APPLICABLE FACTORS. IN ADDITION THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF EACH APPARATUS (OTHER THAN THE TERMINATION) CONNECTED TO THE FIELDBUS MUST BE LESS THAN OR EQUAL TO 5 nf AND 10 uh RESPECTIVELY. IN EACH SEGMENT ONLY ONE ACTIVE DEVICE, NORMALLY THE ASSOCIATED APPARATUS, IS ALLOWED TO PROVIDE THE NECESSARY ENERGY FOR THE FIELDBUS SYSTEM. THE VOLTAGE (Uo OR Voc OR Vt) OF THE ASSOCIATED APPARATUS HAS TO BE LIMITED TO THE RANGE OF 9 V TO 17.5 VDC. ALL OTHER EQUIPMENT CONNECTED TO THE BUS CABLE HAS TO BE PASSIVE, MEANING THAT THEY ARE NOT ALLOWED TO PROVIDE ENERGY TO THE SYSTEM, EXCEPT FOR A LEAKAGE CURRENT OF 50 ua FOR EACH CONNECTED DEVICE. SEPARATELY POWERED EQUIPMENT NEEDS A GALVANIC ISOLATION TO ASSURE THAT THE INTRINSICALLY SAFE FIELDBUS CIRCUIT REMAINS PASSIVE. THE CABLE USED TO CONNECT THE DEVICES NEEDS TO HAVE THE PARAMETERS IN THE FOLLOWING RANGE: LOOP RESISTANCE R': 15 TO 150 ohms/km INDUCTANCE PER UNIT LENGTH L: 0.4 TO 1 mh/km CAPACITANCE PER UNIT LENGTH C': 80 TO 200 nf/km C' = C' LINE/LINE + 0.5' LINE/SCREEN, IF BOTH LINES ARE FLOATING OR C' = C' LINE/LINE + C' LINE/SCREEN, IF THE SCREEN IS CONNECTED TO ONE LINE. LENGTH OF SPLICE: < 1 m (T BOX MUST ONLY CONTAIN TERMINAL CONNECTIONS WITH NO ENERGY STORAGE CAPABILITY) LENGTH OF SPUR CABLE: < 30 M LENGTH OF TRUNK CABLE: < 1 km AT EACH END OF THE TRUNK CABLE AN APPROVED INFALLIBLE TERMINATION WITH THE FOLLOWING PARAMETERS IS SUITABLE: R = 90 TO 100 ohms AND C = 0 TO 2.2 uf NOTE, A BUILT IN TERMINATOR IS INCLUDED IN THE FIELD SIDE AND A SELECTABLE TERMINATOR IS AVAILABLE ON THE HOST SIDE. THE NUMBER OF PASSIVE DEVICES CONNECTED TO THE BUS SEGMENT IS NOT LIMITED IN THE FISCO CONCEPT FOR INTRINSICALLY SAFE REASONS. IF THE ABOVE RULES ARE RESPECTED, UP TO A TOTAL LENGTH OF 1000 m (SUM OF THE LENGTH OF THE TRUNK CABLE AND ALL SPUR CABLES), THE INDUCTANCE AND CAPACITANCE OF THE CABLE WILL NOT IMPAIR THE INTRINSIC SAFETY OF THE INSTALLATION. INSTALLATION MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) AND ANSI/ISA RP12.6.01. MAXIMUM SAFE AREA VOLTAGE SHOULD NOT EXCEED 250 Vrms. RESISTANCE BETWEEN INTRINSICALLY SAFE GROUND AND EARTH GROUND MUST BE LESS THAN ONE OHM LOOPS MUST BE CONNECTED ACCORDING TO THE BARRIER MANUFACTURER'S INSTRUCTIONS. IF HAND HELD COMMUNICATOR OR MULTIPLEXER IS USED, IT MUST BE WITH ENTITY PARAMETERS AND INSTALLED PER THE MANUFACTURER'S CONTROL DRAWINGS. GE42819, sheet 8, Rev. G 12

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 15. Notes for FM Loop Schematics CONTINUED FOR NONINCENDIVE APPLICATION, E.G. CLASS I DIVISION 2 OR AEx ic, PLEASE NOTE THE FOLLOWING: HART MODELS DURING NORMAL OPERATION, THE VOLTAGE OF THE FIELD WIRING CIRCUIT CONNECTED TO THE DIGITAL VALVE CONTROLLER IS CONTROLLED BY THE DIGITAL VALVE CONTROLLER ITSELF. THEREFORE, THE LIMITING FACTOR IS THE MAXIMUM CURRENT, Imax OR Ii, WHICH MUST NOT BE EXCEEDED. FIELDBUS/PROFIBUS MODELS DURING NORMAL OPERATION, THE CURRENT OF THE FIELD WIRING CIRCUIT CONNECTED TO THE DIGITAL VALVE CONTROLLER IS CONTROLLED BY THE DIGITAL VALVE CONTROLLER ITSELF. THEREFORE THE LMITING FACTOR IS THE MAXIMUM VOLTAGE, Vmax OR Ui, WHICH MUST NOT BE EXCEEDED. CAUTION/WARNING THE APPARATUS ENCLOSURE CONTAINS ALUMINUM AND IS CONSIDERED TO CONSTITUTE A POTENTIAL RISK OF IGNITION BY IMPACT AND FRICTION. AVOID IMPACT AND FRICTION DURING INSTALLATION AND USE TO PREVENT RISK OF IGNITION. GE42819, sheet 8A, Rev. A 13

DVC6200 Digital Valve Controllers Instruction Manual Supplement Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay, 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 14 2017 Fisher Controls International LLC. All rights reserved.