ACCESSIBILITY REQUIREMENTS FOR SINKS

Similar documents
WEST HOLLYWOOD ACCESSIBLE UNISEX BATHROOMS: COMMERCIAL CLEARANCES. Accessible Unisex Bathrooms: Commercial Page 1 of 5

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS

Priority 3 - Toilet Rooms

Priority 3 - Toilet Rooms

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

NCIDQ Restroom Drawing. Answers to the most common questions about this drawing for the Practicum Qpractice

Accessible Toilet Stalls 6/18/03 1

REAR FRONT 93' 20' 12' 48' 120' 30' 52' 75' Sample Shopping Center. Unit # 5 +/- 10,920 GLA GROUND FLOOR. Width +/- 105' Depth +/- 120' Site Map

Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers

WALKS AND SIDEWALKS REQUIREMENTS:

KEYS TO COMPLIANCE ASSEMBLY AND MERCANTILE OCCUPANCIES ACCESSIBLE TOILET COMPARTMENTS. Figure 16 Handrail cross section {505.7}

atm installation for accessibility a guide to ada/aba accessibility guidelines

Chapter 4. Accessible Routes

CKBD Peakes Bath Scoresheet

404 Doors, Doorways, and Gates

grab BarS and rails 800 SerieS

ID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES:

ADA Barrier-Free Bathware for Assisted Living

Dry Toilet, Version 2.0 June 17, 2015

A.1 KING RESTROOM DEMOLITION PLAN. KING PARK 725 Monte Diablo Ave, San Mateo, CA LEGEND A.2 4 SCALE:

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Letter of Transmittal

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

Chapter General. Accessible built-in storage facilities shall comply with Section 905. Chapter 9. Built-in Furnishings and Equipment

Jan H: ARCHITECTURAL WOODWORK (06410-H)

Installation Instructions. Installation Type

Installation Instructions. Installation Type

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

Installing Electronic Media Storage Components into Lateral File Cabinets

1 PREPARE HEADER AND ROUGH OPENING

City of Thousand Oaks

GE Monogram 36" Built-In French-door Bottom-freezer

Installation Instructions

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

SUPPLEMENT 2 TO SECTIONS 14 & 15

Extra Wide Designer Lockers Series Installation Instructions

SECTION SIGNAGE

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

MONOGRAM 36" BUILT-IN ALL-REFRIGERATOR

1907 Grayson Street North Charleston, SC TMS: FRANKLIN DESIGN

-1- Coach Instructions.

SECTION PLUMBING FIXTURES


The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

Example Plans: Business Signs (Not For Construction)

ZIC360NR GE Monogram 36" Built-In Bottom Freezer Refrigerator with Automatic Icemaker The Installation Space

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

INSTALLATION INSTRUCTIONS

Custom. Options Guide. and. Installation Instructions. GE Monogram 36" Built-In Refrigerators. Models: ZIS36NY ZISW36DY ZISB36DY

SECTION IDENTIFYING DEVICES

INSTALLATION MANUAL 32273/1205 C C-403 GB - F - D - NL - ES - I - S - SLO

GRAF HALL ADA ASSESSMENT & SURVEY

CounterBalance CounterPlate Plus

OVERALL DIMENSIONS 36" (91.5) (213.4) 84" (213.4 cm) ** Allow 25" (63.5) min clearance for 130 door swing

9 X 12 FIXED TYPE ALUMINUM WINDOW BARS INSTALLATION INSTRUCTIONS Import Note : 9 X 12 Spacing Fixed Type Installation is covered in this Instruction.

DC3210. Recommended Closer Size

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

COMMERCIAL VISUAL INDEX LOBBIES COMMERCIAL VISUAL INDEX NURSE S STATIONS. General Safety. General Safety. Kitchens

GE Monogram 36" Built-In Bottom-freezer Refrigerator

Wayne State University. Prentis Building Renovation. NM Project Number: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Barn Door & Hardware Installation Guide

Bathroom Fittings. Hardware Bathroom Washroom Handrail Wardrobe Signs KNUD HOLSCHER H DESIGN

SECTION 2: INSTALLATION

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Hardware Bathroom Washroom Handrail Signs. Bathroom Fittings

Elementary Dimensioning

BASEBALL PLAYER FACILITIES CLEMSON, SOUTH CAROLINA

Sitting Height Base Cabinets

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

VERDERA T01-A INSTALLATION INSTRUCTIONS MIRRORED CABINET K-99003T-R/K-99003T-L K-99005T-R/K-99005T-L K-99009T

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750.

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions

MONOGRAM 36" BUILT-IN ALL-FREEZER

11SIXTY5 Weaver Dairy Road

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

BALANTINE WALL-MOUNT FAUCET INSTALLATION

MONOGRAM 36" BUILT-IN ALL-FREEZER

83199 Grain Tank Auger Liner John Deere 9650 STS, 9750 STS, & 9570 STS Installation Instructions

INSTALLATION MANUAL. semihandmade

Installation. *HDWC-INSTR-007* HDWC-INSTR-007 Rev. K; ECN G 2018 Bradley Page 1 of 24 3/22/2018

Potting Bench Assembly Manual Outdoor Living Today

Tolerancing. Summary

SLIDE 06 Solutions Document/Installation Manual

Installation. *HDWC-INSTR-008* HDWC-INSTR-008 Rev. H; ECN G 2018 Bradley Page 1 of 24 3/22/2018

Agave Standard Series

Y1160A EIA Rack Sliding Shelf Installation Note

Building an Elevated Garden Bed & Hydroponic Table

Superior by Design. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

AIR MASTER SYSTEMS INSTALLATION GUIDE TABLE OF CONTENTS

4Post and 2Post Rails for Dell PowerEdge R810

OFS ED-6C Instruction Sheet LIGHTGUIDE CROSS-CONNECT Comcode: LGX DISTRIBUTING FRAME INSTALLATION

INSTALLATION INSTRUCTIONS John Deere 600C Corn Head Auger Trough Liner


INSTALLATION AND CUSTOMER CARE INFORMATION FOR SC FREESTANDING STERILIZATION CENTERS

Installation *HDWL-INSTR-001* IMPORTANT. Plastic Laminate Restroom Partitions Floor-Mounted with Overhead Brace Series 400

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

Transcription:

ACCESSIBILITY REQUIREMENTS FOR SINKS 1. Max. Height to top of counter at sink 2. Min. toe clearance 3. Plan view of 30 x48 clear space and depth 4. Min. knee clearance 5. Plan view of 30 x48 clear space and 25 max. sink depth 1. See 2. below 48 min. Fig. 306.2 Toe Clearance 2. 3. 48 min. Fig. 306.3 Knee Clearance 4. \\cordata\planning\handouts 2016\Handouts_Current_2015 Code\Accessiblility Requirements.doc (11-28-17) Page 1 of 6 5.

ACCESSIBILITY REQUIREMENTS FOR TOILETS Accessible Req s for Toilets (Not in a compartment) 1. Plan view of side clearance 2. Rear grab bar req d 3. Side grab bars req d 4. Height of toilet seat 5. Dispenser location 6. Dispenser location if above the grab bar 7. 16-18 clear to C.L. 1. 2. 3. 4. 5. 6. 7. \\cordata\planning\handouts 2016\Handouts_Current_2015 Code\Accessiblility Requirements.doc (11-28-17) Page 2 of 6

GRAB BAR REQUIREMENTS FOR RESTROOMS IN COMMERCIAL BUILDINGS 604.5.1 Side Wall. The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. Figure 604.5.1 Side Wall Grab Bar at Water Closets Figure 604.5.2 Rear Wall Grab Bar at Water Closets 604.5.2 Rear Wall. The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on the other side. EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location of a recessed fixture adjacent to the water closet.2. Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area. \\cordata\planning\handouts 2016\Handouts_Current_2015 Code\Accessiblility Requirements.doc (11-28-17) Page 3 of 6

TURNING SPACE REQUIREMENTS INSIDE TOILET ROOMS ANSI Sec 304 & 603.2 Either the standard 60 turning Circle or the T-shaped turning space shown on this handout are allowed. Doors can swing into this turning space but cannot swing into the clearance around the toilet or the sink (see other handouts). This turning space can overlap with the clearance requirements of the other handouts (toilets and sinks). Either of these turning spaces can use a knee and toe clearance underneath a sink as part of their turning area. Figure 304.3.2 T-Shaped Turning Space \\cordata\planning\handouts 2016\Handouts_Current_2015 Code\Accessiblility Requirements.doc (11-28-17) Page 4 of 6

ACCESSIBILITY REQUIREMENTS AT DOORS Please note that these drawings and this information is not meant to be a comprehensive list of all the requirements that apply to doors. These are simply the most commonly asked questions and the most common problems encountered during construction. The actual verbiage of the requirements can be obtained from the ANSI standard where the ADA law comes from (copyrighted publication, some excerpts available upon request). Many other requirements exist relative to handicap accessibility and maneuvering at all doors and doorways. Please ask questions before you install something. The City will try to help where it can. In projects where an architect or engineer (generally on commercial projects over 4,000 s.f. in size) is responsible for the accessibility design, please consult with them, as they will be required to design and draw the details for accessibility. In drawing (a) below, the only door that will meet this minimum clear width is a 36 wide door. That is what you will see all doors in commercial buildings being 3-0 wide. In drawing (b) below, the most common problem with sliding doors is the handle which may prevent the door from opening to 32 wide. Make sure before buying the door hardware. Figure 404.2.3 Clear Width of Doorways \\cordata\planning\handouts 2016\Handouts_Current_2015 Code\Accessiblility Requirements.doc (11-28-17) Page 5 of 6

ACCESSIBILITY REQUIREMENTS AT DOORS MANEUVERING CLEARANCE REQUIREMENTS \\cordata\planning\handouts 2016\Handouts_Current_2015 Code\Accessiblility Requirements.doc (11-28-17) Page 6 of 6