Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

Similar documents
MT 560/UMT TRANSDUCER & ANALYZER

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Programmable AC Current Transducer MT418

Programmable AC Voltage Transducer MT416

ELECTRICAL NETWORK RECORDER - MC 750 ELECTRICAL NETWORK ANALYZER -MC 760 ENERGY METER - MC 720 POWER METER - MC 710 MULTIFUNCTION METER - MC 740

Measuring transducers

Measuring centers MC7x0 series Multifunction Meter MC740

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Product Guide. Transducers

Energy Management Modular Smart Power Transducer Type SPT-90

Universal measuring transducer

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

DATA SHEET Selectable AC transducer TAS-311DG

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Theta 20A / 20V. Technical Data Sheet. Special Features

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

Integra 1560 and 1580 Digital Transducer Systems

ULTRA RAPID POWER QUALITY ANALYZER

ND40 - POWER NETWORK ANALYZER /RECORDER

Energy Management Modular Power Analyzers Type WM2-96

NETWORK ANALYZERS Analyzers

PEM353. Universal measuring device

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RISH Ducer E13 3 channel transducer for AC current and voltage

DE MEDIDA PROGRAMABLES - CLASE 0,2 MEASURING PARAMETER. Apparent power, per phase and total

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Theta Hz. Technical Data Sheet. Special Features

Operating Guide October 2006

MEASURING TRANSDUCERS PROGRAMMABLE TRANSDUCERS

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Data Sheet. RISH Master Record %THD

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Power Quality and Energy Measurement PEM575

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power Quality and Energy Measurement PEM575

Power Quality and Energy Measurement PEM533

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

N30P DIGITAL PANEL METER

Measurement and control. Digital instruments and measuring transducers

METRAClip87 and 88 Clamp Multimeters

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

Power Meter Series PM3200 Functions and characteristics

EM-72 Electricity Meters for Current Transformers

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Energy Management Energy Analyzer Type EM210 MID

Energy Division

Installation and Operating Instructions

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Energy Management Energy meters Type EM2-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

SINEAX V 604s Programmable multifunctional transmitter

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Paladin Transducers 250 Series Class 0.5 and Class 0.2

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

INSTALLATION INSTRUCTIONS QUICK START GUIDE. Multi-transducer, MTR-3. Document no.: B SW version 3.0X.X or later

XP2-R Power and Reverse Power Relay

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

DM-III Multitest & DM-III Multitest F Power Quality Recorders

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Mars-Energo. Volt/mA Calibrator CALMAR-S. User s manual Edition 3.1

SINEAX U 553 Transducer for AC Voltage

Energy Management Energy Analyzer Type EM210

Power Quality and Energy Measurement PEM330/PEM333

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Universal-Transducer Multi-E11-MU

SUBJECT TO CHANGE WITHOUT NOTICE

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

AMIK 200 / 201 Technical Data Sheet

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Multimeter 500CVD21 RTU500 series

S200 I/O System Units

Technical Data Sheet AMIK 300 / 301

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Transcription:

Measuring Transducers Transducing electrical quantities Iskra MIS d.d. Measuring Transducers Features AC, DC POWER SYSTEM MEASUREMENT MICROPROCESSOR CONTROL HOUSING FOR DIN RAIL MOUNTING IN COMPLIANCE WITH EN 50022 PROGRAMMABLE VOLTAGE RANGE PROGRAMMABLE CURRENT RANGE PROGRAMMABLE ANALOGUE SERIAL COMMUNICATION RS232/RS485 (OPTION) UP TO THREE ELECTRICALLY ISOLATED ANALOGUE S UNIVERSAL AUXILIARY POWER SUPPLY (OPTION) ACCURACY CLASS 0.5 (FREQUENCY TRANSDUCER 0.2) CURRENT S ELECTRICALLY ISOLATED FROM THE SYSTEM S, SERIAL COMMUNICATION, AUXILIARY POWER SUPPLY, CURRENT AND VOLTAGE S GALVANICALLY SEPARATED (SOME MODELS)

Description Digital technology, on which measuring transducers are built, enables them, with corresponding software, to adapt to different input and output quantities. Input quantities, for energy measuring transducers, of phase voltage can be set within the range from 50 to 500 V and currents from 0.2 to 5 A. Values of analogue outputs can also be set within the range from 1 to 20 ma for current and from 1 to 10 V for voltage. Input-output characteristics can be created with five breaking spots for unipolar and bipolar output signals. The accuracy class of measuring transducers is 0.5, except for frequency, where accuracy class is 0.2. MISET Software / Features - Configuring and setting software - Full instrument setup capability - Displays data in real time - Windows compatible - User friendly The above stated versions of measuring transducers can be provided with the RS232 or RS485 communication for connection to the network. The MODBUS communication protocol is used with bit rate from 1,200 to 115,200 bit/s. A measuring transducer with three electrically isolated bipolar analogue outputs (MI400) is the most capable version. Outputs can be software adapted to any measured quantity (voltage, current, power, power factor, frequency) for a phase or for a complete system value. The transducer is supplied with a universal supply module within the range from 24 to 300 V DC or 40 to 276 V AC voltage. Beside AC measuring transducers we produce also DC programmable measuring transducers for conversion of DC current and voltage, resistance and temperature into appropirate DC current or voltage signals. Their analogue output signal is proportional to the measured value and it is appropriate for regulation of analogue and digital devices. Input quantities for DC measuring transducers can vary from 50 mv to 300 V for voltage and from 1 ma to 1 A (up to 7.5 A as special version) for current. Output values are similar to output values of AC measuring transducers. Accuracy class for both (current and voltage) DC measuring transducer is 0.5. MISET Software / Application MISET software is created for configuring and setting of all the instruments with serial communication port (RS232 or RS485) connected in your power network. Devices must be connected to the computer via RS232 communication port (one device, or up to 32 devices connected in network via RS485/RS232 communication converter). With MISET software you can set any parameter of your device, such as input values and transformer ratios, type and value of output and its characteristic, address, communication speed. It also displays measured values in numerical format and in table form. PC software MISET is user friendly and involves help function to simplify the work. MISET Software / System requirements - Windows 95, 98, Millennium, 2000, XP, NT4.0-50 MB available disk space - VGA monitor - Min. 32 MB of RAM - CD drive - RS232 communication port Measuring quantities - AC voltage and current - RMS AC voltage and current - Active and reactive power - Frequency - Power factor - Resistance - DC voltage and current - Temperature - TAP position

Differences between measuring transducers Our measuring transducers can be divided into two groups: MI400 multifunctional measuring transducer and all the others. MI400 is the most powerful multifunctional measuring transducer. It supervises simultaneously any 3 values of an electrical system. It has the capability of measuring more than 50 different electrical quantities such as: TRMS values of voltage, current, kw, kvar, kva, PF, Hz, MD, THD etc in one instrument. All values are available via communication port for monitoring on the PC. It can have up to three configurable analogue outputs, which are programmable. Programmable are also CT and VT ratios. All the other measuring transducers compose group MI4xx (4xx greater than 400). Each measuring transducer in this group is tailored for measuring one electrical quantity. In the table below you can see which functionality is covered by which instrument and instrument's input and output values. Input quantity Programmable Active power Reactive power Power factor transducer transducer transducer measuring TYPE MI400 MI413 MI414 MI421 Class 0.5 1 With auxiliary power supply Measuring principle Microprocessor control Measuring range -Pn...0...Pn -Pn...0...Pn -Qn...0...Qn Cap. 0...1...0 Ind. -Qn...0...Qn 0...Pn 0...Qn -180...0...+180 -Sn...0...Sn Cap. 0...1...0 Ind. -180...0...+180 45...65 Hz 0...1.2 Un 0...1.2 In Input voltage Un 0...50-500 V Nominal voltage Programmable range Input current In 0...0.5-5 A Nominal current Programmable range Nominal frequency 50/60 Hz Consumption/Input Voltage circuit: U 2 /3 MΩ Current circuit: Ι 2 x 0.01 Ω resistance Overload capability Range selection Numbers of analogue outputs Current nominal values 1.5 Un; 2 In 57, 100, 110, 230, 400, 500 V AC, ± 20%, 45...65 Hz 3 VA Universal auxiliary power supply 24...300 V DC 40...276 V AC Programmable range over communication, at placing order 0, 1, 2 and 3 1-1 ma...0 (0.2)...1 ma -5 ma...0 (1)...5 ma -10 ma...0 (2)...10 ma -20 ma...0 (4)...20 ma -1 V...0... 1 V, -10 V... 0...10 V Yes (Optional)- Voltage nom. values Harmonic analysis Maximum Demand Yes - Communication RS232 or RS485 RS232, RS485 (optional) Residual ripple < 1 % p.p. on nominal current Response time < 300 ms Burden max. I output 5 ma 3 kω, 10 ma 1.5 kω, min. U output 20 ma 750 Ω, 10 V 500 Ω Working temperature -10 +55 C Storage temperature -40...+70 C Climatic class 3 according to EN 60688 General technical data Protection system: IP 50, terminals IP20, according to EN 60529, 1989 Characteristic curves Dimensions A, B, C, D A = 100 mm, B = 75 mm, C = 104.5 mm

Input quantity 3 x AC - 3 x AC - Frequency Voltage Current TYPE MI436 MI438 MI420 Class 0.5 0.2 With auxiliary power supply Measuring principle Microprocessor control Measuring range 0..50 V to 0..500 V 0..6 A, 1 A, 5 A 40 to 70 Hz Input voltage 500 V programmable, 3...500 V Nominal voltage 57.74, 63.5, 100, 110, 230, 250, 400, 500 V fixed configuration Input current Nominal current Nominal frequency 50/60 Hz 6 A programmable 1 A, 5 A fixed configuration 45...55 Hz 48...52 Hz 45...65 Hz 55...65 Hz Consumption / Input U 2 / 3 MΩ I 2 0.01 Ω < 0.5 VA resistance Overload capability 1.2 Un 2 In 1.2 Un Universal auxiliary power supply 57, 100, 110, 230, 400, 24...300 V DC, 40...276 V AC, 40...70 Hz, < 3 VA 500 V AC, ±20%, Universal auxiliary power supply 24...300 V DC 40...276 V AC Range selection Programmable range over communication, at placing order Number of analogue outputs 3 1 Current nominal values 0 (0.2)...1 ma 5 ma, 20 ma 0 (1)...5 ma programmable 10 ma fixed configuration 5 ma, 10 ma, 20 ma, 0 (4)...20 ma 4...20 ma fixed 4...20 ma fixed configuration Voltage nom. values 0...1 V to 0...10 V 10 V programmable, fixed Harmonic analysis Yes (Optional)- Maximum Demand - Yes (thermal function)- Communication RS232, RS485 (optional) Residual ripple on < 1% p.p. nominal current Response time < 300 ms Burden max. I output 5 ma 3 kω, 10 ma 1.5 kω, 20 ma 750 Ω, 10 V 500 Ω min. U output Working temperature -10 +55 C -10 +55 C Storage temperature -40 to +70 C -40...+70 C Climatic class 3 according to EN 60688 3 according to EN 60688 General technical data Protection system: IP 50, terminals IP20, according to EN 60529, 1989 Characteristic curves A, B A, B, D Dimensions A = 100 mm, B = 75 mm, A = 44.8 mm, B = 75 mm, C = 104.5 mm C = 104.5 mm

Input quantity AC - Voltage AC - Current RMS RMS AC - Voltage AC - Current TYPE MI406 MI408 MI416 MI418 Class 0.5 Without auxiliary power supply With auxiliary power supply Measuring principle Rectifier method Microprocessor control Measuring range 0.2...Un 0...In 0...1.2 Un 0...1.2 In Input voltage Un 0...20 to 0...500 V Un 0...50 V to 0...500 V programmable range Nominal voltage 57.74, 63.5, 100, 57.74, 63.5, 100, 110, 250, 500 V 110, 230, 250, 400, 500 V Input current In 0...1 A to 0...7.5 A In 0..6 A programmable range Nominal current 1 A, 5 A In 1 A, 5 A fixed configuration Nominal frequency 50/60 Hz Consumption / Input < 2 VA < 2 VA < 0.5 VA < 0.5 VA resistance Overload capability 1.2 Un 2 In 1.2 Un 2 In 57, 100, 110, 230, 400, 500 V AC, ± 20 %, from measuring circuit 45...65 Hz 3 VA Universal auxiliary power supply 24...300 V DC, 40...276 V AC Range selection At placing order Programmable range over communication, at placing order Number of analogue outputs 1 Current nominal values 0...5 ma 0 (0.2)...1 ma 0...10 ma 0 (1)...5 ma 0...20 ma 0 (2)...10 ma 0 (4)...20 ma Voltage nom. values 0...1 V, 0...10 V Harmonic analysis - Yes (Optional) Maximum Demand - Communication - RS232, RS485 (optional) Residual ripple on nominal current < 1% p.p. Response time < 300 ms Burden max. I output 5 ma 3 kω, 10 ma 1.5 kω, 5 ma 3 kω, 10 ma 1.5 kω, min. U output 20 ma 750 Ω 20 ma 750 Ω, 10 V 500 Ω Working temperature -10 +55 C Storage temperature -40...+70 C Climatic class 3 according to EN 60688 General technical data Protection system: IP 50, terminals IP20, according to EN 60529, 1989 Characteristic curves A A, B, D Dimensions A = 44.8 mm, B = 75 mm, C = 104.5 mm

Input quantity Temperature Resistance Potenciometer & Pt 100 TAP position TYPE MI450 MI452 MI454 Class 0.5 With auxiliary power supply Measuring principle Microprocessor control Measuring range 0..20 Ω to 0..10 kω 0...Rn 0..100Ω to 0..500kΩ Un < 2.2 V R0 Rn...R0 Un < 2.2 V Input value -200 C +850 C for Pt Rn 0..10 Ω - 50 kω Rn 100 Ω to 500 kω -60 C +250 C for Ni 0..100 Ω - 500 kω programmable 20 Ω to 10 kω for programmable polinom programmable Nominal value 0 to 100, 0 to 250, Rn 100, 1 k, 2 k, 5 k, Rn 100, 1 k, 2 k, 5 k, 10 k -100 to 800 C for Pt 10 k, 20 k, 50 kω fixed 20 k, 50 k, 100 k, 200 k, 0 to 100, 0 to 180, Rn 5 k, 10 k, 50 k, 100 k, 500 kω 0-linear -50 to 150 C for Ni 200 k, 500 kω fixed Rn 300, 1 k, 2 k, 5 k, 10 k, fixed configuration 20 k, 50 k, 100 k, 200 k, 500 kω 10 steps (both fixed configuartion) Nominal frequency - Consumption / Input resistance < 0.5 VA 57, 100, 110, 230, 400, 500 V AC, ± 20 %, Universal auxiliary power supply: 24...300 V DC, 40... 276 V AC Range selection Programmable range over communication, at placing order Number of analogue 1 outputs Current nominal -1...0 (0.2)...1 ma 0 (0.2)...1 ma values -5...0 (1)...5 ma 0 (1)...5 ma -20...0 (4)...20 ma 0 (4)...20 ma Voltage nom. values -1...0...1 V, -10...0...10 V 0...1 V, 0...10 V Harmonic analysis - Maximum Demand - Communication RS232, RS485 (optional) Residual ripple on < 1 % p.p. nominal current Response time Programmable 0.5 s to 60 s Burden max. I output min. U output 5 ma 3 kω, 10 ma 1.5 kω, 20 ma 750 Ω, 10 V 500 Ω Working temperature -10 +55 C Storage temperature -40...+70 C Climatic class 2 according to EN 60688 General technical Protection system: IP 50, terminals IP20, according to EN 60529, 1989 data Characteristic curves A, B, C, D A Dimensions A = 44.8 mm, B = 75 mm, C = 104.5 mm

Input quantity DC - DC - RS232 to Voltage Current RS485 TYPE MI456 MI458 MI485 Class 0.5 - With auxiliary power supply Measuring principle Microprocessor control - Measuring range 0...Un 0...In RS485 -Un 0...Un -In 0...In Bit rate to115200 bit/s Input value Un 0...50 mv 1 V In 0...1 10 ma - 0..1 50 V 0...10 100 ma 0..50 300 V programmable programmable Nominal input Un 50, 100, 500 mv, In 1, 1.5, 2, 2.5, 4, 5, 6, 1 V fixed 10 ma fixed 1.5, 2, 2.5, 4, 5, 6, In 15, 20, 25, 40, 50, 10, 15, 20, 25, 40, 60, 100 ma fixed 50 V fixed 60, 100, 150, 200, 250, 400 V fixed Nominal frequency DC - Consumption / < 0.5 VA < 0.5 VA Input resistance Overload capability 1.2 Un 2 In - 57, 100, 110, 230, 400, 500 V AC, ± 20 %, 45...65 Hz 3 VA Universal auxiliary power supply 24...300 V DC 40...276 V AC Range selection Programmable range over communication RS232 at placing order Electrically isolated Number of analogue 1 Terminals or SUB D outputs connector Current nominal -1 ma...0 (0.2)...1 ma Indication values -5 ma...0 (1)...5 ma communication with -20 ma...0 (4)...20 ma LED Diode Voltage nom. values -1V...0...1V, -10V...0...10V Harmonic analysis - Maximum Demand - Communication RS232, RS485 (optional)- Residual ripple on < 1% p.p. - nominal current Response time Programmable 0.5s to 3s - Burden max. I output min. U output 5 ma 3 kω, 10 ma 1.5 kω, 20 ma 750 Ω, 10 V 500 Ω - Working temperature -10 +55 C Storage temperature -40...+70 C Climatic class 3 according to EN 60688 General technical data Protection system: IP50, terminals IP20, according to EN 60529, 1989 Characteristic curves A, B, C, D - Dimensions A = 44.8 mm, B = 75 mm, C = 104.5 mm Note: Transducers according to EN 60688 1, EN 61010 1

Characteristic curves a) linear characteristic b) up to 5 break points c) zoom absolute value d) zoom Case dimensions Ordering info Ordering informations for each transducer are available in technical leaflets. Version 2, September 2004