USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

Similar documents
USER S MANUAL VAF POWER METER TRINITY. VAF Operational Manual

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

Digital Multifunction Instrument - Rish Master 3440

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Data Sheet. RISH Master Record %THD

Technical Data Sheet AMIK 300 / 301

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Installation and Operating Instructions

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

AMIK 200 / 201 Technical Data Sheet

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

TAS APFC Controller / Load Managers with MOD-BUS Interface

Technical Data Sheet. x1000. kwh R Y B

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

SERIES 3000 Kilowatt Hour Meter

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Contents. Introduction and description Package contents Device identification PM Options... 80

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

LARSEN & TOUBRO LIMITED

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

Integra 1560 and 1580 Digital Transducer Systems

installation guide XMFM1

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

User's Manual. Model f/1f Power Clamp-on Meter

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

MODBUS RS485 SERIAL PROTOCOL

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Operating Guide October 2006

MultiCube Multi-Function Electricity Meter. Installation and Operation

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

ET3 ADVANCED POWER TRANSDUCER

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

Warranty Terms & Conditions

Technical Data Sheet

Energy Management Energy Meter Type EM112

Ziegler EM 1320/30/40

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SANPERA I. Player`s Handbook

Preliminary Data Sheet!

Centrale de mesure Power Meter PM500 Merlin Gerin

PM-PA/PM-PAC POWER ANALYZER

Power Requirements. Features

Energy Management Energy Meter Type EM340

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Energy Management Energy Meter Type EM111

EPM Single-point submetering system. imagination at work. Engineered for retrofit and new construction with power line communication capability

User s Guide FM Transmitter

Grid Radar Installation Manual

Energy Management Energy Analyzer Type EM112

ELECTRONIC METER MX2-A01E MX2-C01E MX2-C41E MX2-B41E MODBUS RTU Interface Specifications MDD-T0026

LIMITED 90-DAY CONSUMER WARRANTY LIMITED TWO-YEAR CONSUMER WARRANTY WITH PURCHASE AND INSTALLATION BY A SOUNDSTREAM AUTHORIZED DEALER

DPF-MAC Auto power factor controller

Dual Purpose Projection Screen

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Copyright Teletronics International, Inc. Patent Pending

Model 935A Current Source Operation Manual

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

ASCO 5210 Digital Power Meter. Operator s Manual DANGER

Digital Lighting Systems, Inc.

Energy Management Energy Meter Type EM21 72R Retro-Fit

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

4111 Usage Minutes 1 Integer RO Y - Minutes 0-59 Y Y YP

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

Document Version 1.2

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups

SSR-150xxx-40VL-12P-xC-xxxCS

E50 MODBUS POINT MAP

Tegra 710 and 810 Digital metering with RS485 Modbus TM o/p

Series 3000 Model R-107A

SSR VL-12P-xC-NCS

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

BC145 SIGNAL ISOLATOR BOARD

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1

OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

F Series SINGLE-PHASE DIGITAL SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODELS

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

Table of Contents. Safety Notices

COMMERCIAL TRANSMITTER INSTRUCTIONS

AM/FM Stereo Headset Radio

H8238/MCM MODBUS POINT MAP

Transcription:

USER S MANUAL EMPOWER POWER METER This document contains the latest technical information about Empower which is a micro-controller based Power meter. The product Empower is sophisticated electronic equipment, and the user is advised to read this User s Manual carefully before attempting to install or operate the equipment. Published on: (mention the date of publishing) Document Version: 1.0 [1]

Warranty statement Trinity warrants to the original retail purchaser of the Trinity product enclosed with this limited warranty statement that the product, if purchased new and used in the India conforms to the manufacturer s specifications and will be free from defects in workmanship and materials for a period of one year from the date of original purchase, unless expressly stated otherwise by Trinity, in a written format. Should your Trinity product prove defective during the warranty period, please bring the product securely packaged in its original container or an equivalent, along with proof of the date of original purchase, to our Trinity Dealer or Factory. You are responsible for all costs (shipping, insurance, travel time) in getting the product to the service location. Trinity will, at its option, repair or replace on an exchange basis the defective unit, without charge for parts or labor. When warranty service involves the exchange of the product or of a part, the item replaced becomes Trinity property. The replacement unit may be new or refurbished to the Trinity standard of quality, and at Trinity s option, the replacement may be another model of like kind and quality. Trinity s liability for replacement of the covered product will not exceed the original retail selling price of the covered product. Exchange or replacement products or parts assume the remaining warranty period of the product covered by this limited warranty. What This Warranty Does Not Cover: This warranty does not apply to refurbished or reconditioned products. This warranty covers only normal use in India. This warranty does not cover damage to the Trinity product caused by parts or supplies not manufactured, distributed or certified by Trinity. This warranty is not transferable. This warranty does not cover third party parts, components or peripheral devices added to the Trinity product after its shipment from Trinity. Trinity is not responsible for warranty service should the Trinity label or logo or the rating label or serial number be removed or should the product fail to be properly maintained or fail to function properly as a result of misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters such as fire, flood, and lightning, improper electrical current, interaction with non-trinity products, or service other than by an Trinity Authorized Service. The warranty and remedy provided above are exclusive and in lieu of all other express or implied warranties including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose. In the event, the remedies above fail, Trinity s entire liability shall be limited to a refund of the price paid for the Trinity product covered by this limited warranty. Except as provided in this written warranty, neither Trinity Energy Systems Pvt. Ltd. nor its affiliates shall be liable for any loss, inconvenience, or damage, including direct, special, incidental, or consequential damages, resulting from the use or inability to use the Trinity product, whether resulting from breach of warranty or any other legal theory. [2]

Contents Introduction... 4 The Main Features Available in This Model... 4 Front View of the Unit... 4 Technical Specifications... 5 Installation and Commissioning... 6 Back View... 9 RS485 Connection... 10 Operational Details... 11 Programming Mode... 12 Setting CT- primary... 12 Setting a unit address for RS485 port... 13 Run Mode... 14 Run Mode Displays... 14 Freezing and unfreezing the displays... 17 Communication... 18 Modbus RTU on RS485 Port... 18 Appendix... 19 Ordering Options... 20 [3]

Introduction has a host of low cost, easy to use individual and multifunctional meter that offers for all the basic measurement capabilities required to monitor electricity over and above basic metering. These meters also have an RS485 port supporting MODBUS-RTU protocol for integration with SCADA/EMS. The entire range is very rugged and cost-effective. All these products are field proven and more than 100,000 units are active in service. The Main Features Available in This Model All parameters with default accuracy class 1.0S Multiparameter Monitoring Displays with 0.4 Red Seven Segment with LED indicators Measurement of individual voltage and current in three phases Measurement of system powers (KW, KVA and KVAR) Measurement of three energies (KWh, KVAh and KVARh) Frequency and system PF with lead (-) and lag side (+) RS485 port with SCADA/EMS using Modbus-RTU protocol. Front View of the Unit [4]

Technical Specifications SR. NO PARAMETERS & OPTIONS 1 Volts R-N 2 Volts Y-N 3 Volts B-N STATASTICS Direct Voltage Input : 20 to 300V L-N Burden : 0.5VA Secondary Voltage Input : 63.5V* 4 Volts RY Direct Voltage Input : 25 to 500V L-L 5 Volts YB Burden : 0.5VA 6 Volts BR Secondary Voltage Input : 110V* 7 Current R Secondary Current Input : 5A or 1A (To be specified at the time of Ordering) 8 Current Y CT Primary : Site Selectable Range of Reading : 5 5000A Burden : < 1.0VA 9 Current B Overload (Through CT) : 5A CT = 6A RMS Continuous 1A CT = 1.2A RMS Continuous (Whole Current) : 120% of Imax continuous. 10 Frequency 45 to 55 Hz, Accuracy : 0.3% of Reading 11 KWh Range of Reading : 0 to 9999999.0 Accuracy : 1.0S as per IS13779. 12 KVARh Range of Reading : 0 to 9999999.0 Accuracy : 1.5% of Reading (Between 0.5 Lag to 0.8 Lead) 13 KVAh Range of Reading : 0 to 9999999.0 Accuracy : 1.0% of Reading 14 System PF Accuracy : 1% of Reading (IPFI>0.5) Range of Reading : 0.05 to 1.00 Lag/Lead 15 System KVA Accuracy : 1.0% of Reading 16 System KW Accuracy : 1.0% of Reading (Between 0.5 Lag to 0.8 Lead) 17 System KVAR Accuracy : 1.5% of Reading (Between 0.5 Lag to 0.8 Lead) 18 DISPLAY 0.4 Red Seven Seg. 19 RS485 For Integration with EMS/SCADA 20 Bezel 96x96 mm 21 Depth 55 mm DIN enclosure * To be specified at the time of ordering along with PT primary. [5]

Installation and Commissioning The unit can be used only for either 3P4W or 3P3W according to your ordering option and requirement in your electrical installation. To install and commission for 3P4W, proceed the following instructions: 1. Push the unit into the panel and mount using the clamps provided on it. 2. Connect the auxiliary supply (80V AC to 270V AC) to the terminals marked P and N. 3. Connect the three phases with the phase sequence being R-Y-B to the terminals marked U1, U2 and U3 respectively. Make sure that the phases coming to the unit come through control fuses of 1.0A rating. This will protect the electronic inside from damage due to severe over voltage or phase faults in the system. 4. Connect the neutral wire to the terminal marked U4. 5. Connect the two wires from the R-phase CT to the terminal marked M1 and L1 such that S1 from CT goes to M1. 6. Connect the two wires from the Y-phase CT to the terminals marked M2 and L2 such that S1 from the CT goes to M2. 7. Connect the two wires from the B-phase CT to the terminals marked M3 and L3 such that S1 from the CT goes to terminal marked M3. [6]

8. Switch on the auxiliary supply as well as three phase supply and then, the unit will come alive in order to display such as ESPL, CT ratio, Unit Address and Run Mode respectively. 9. Firstly, user should program the settable parameters, CT-primary and unit address for RS485 communication port. (Refer Operational Details in the next section). 10. Now the unit is ready for operation. [7]

To install and commission for 3P3W, proceed the following instructions: 1. Push the unit into the panel and mount using the claim provided on it. 2. Connect the auxiliary supply (80V AC to 270V AC) to the terminals marked P and N. 3. Connect the three phases with the phase sequence being R-Y-B to the terminals marked U1, U4 and U3 respectively. Make sure that the phases coming to the unit come through control fuses of 1.0A rating. This will protect the electronic inside from damage due to severe over voltage or phase faults in the system. 4. Connect the two wires from the R-phase CT to the terminals marked M1 and L1 such that S1 from CT goes to M1. 5. Connect the two wires from the B-phase CT to the terminals marked M3 and L3 such that S1 from the CT goes to the terminal marked M3. 6. Switch on the auxiliary supply as well as three phases supply and then, the unit will come alive in order to display such as ESPL, CT ratio, unit Address and Run Mode respectively. 7. Firstly, user should program the settable parameters, CT-primary and unit address for RS485 communication port as required. (Refer Operational Details in the next section). 8. Now, the unit is ready for operation. [8]

Back View [9]

RS485 Connection [10]

Operational Details The Power Meter, Empower is a versatile meter, with all the features needed to implement for a robust electrical load measurement. It can be configured to monitor most electrical parameters and communication needs and, is also achieved by making field programmable parameters, as possible. There are basically two modes of operation in Empower: 1. Programming Mode 2. Run Mode After supplying power (80 VAC - 270 VAC), the unit displays immediately power receiving information, ESPL on Red Seven Segment screen and by default, the display comes into Run Mode such as shown below. Now, the unit can be operated for both the Programming Mode and Run Mode by pressing the keys such as, and. [11]

Programming Mode In order to operate for all the field programmable parameters, it is easy user interface by pressing the keys such as,, and keys. Once the unit displays CT- PRIMARY, press key to move into the next programmable parameter, UNIT ADDRESS for RS485 communication. Setting CT- primary The CT-primary is settable from 5 to 5000 and, should be set so as to give actual current values in an electrical installation. To set the CT-primary, proceed the following instructions: 1. Press key for about 4 to 5 seconds on Run Mode display. 2. The unit will enter into Programming Mode display with settable parameter, CT-PRIMARY such as shown below. 3. Press key. Immediately, P starts blinking with an interval of one second which shows that the parameter is now settable. Set the CT-primary by using and keys until the desired value is received and then press key to confirm the set value. 4. Now, the unit will reset and return into Run Mode. [12]

Setting a unit address for RS485 port The unit has the provision to specify a meter address at site for RS485 port. This address can be set starting from 1 to 255 with a fixed baud rate of 9600. To set the CT-primary, proceed the following instruction: 1. Press key for about 4 to 5 seconds on Run Mode display. 2. The unit will enter into Programming Mode display with the settable parameter, unit ADDRESS such as shown below. 3. Press key. Immediately, P starts blinking with an interval of one second which shows that the parameter is now settable. Set the ADDRESS by using and keys until the desired value is received and then, press key to confirm the set value. 4. Now, the unit will reset and return into Run Mode. [13]

Run Mode In the run mode, the various parameters calculated by the EMPOWER are displayed on different pages on a three lines of 0.4 Red Seven Segment. There are ten parameters which display on different pages with the system values. Run Mode Displays The Run mode displays will autoscroll by default and stay for each page for an interval of 7 to 8 seconds. Page 1 The LED indicator glows on VOLT with respect to L1, L2 and L3 which shows individual phase to phase voltage of R-Y-B on first row, second row and third row display respectively. Page 2 The LED indicator glows on AMPS with respect to L1, L2 and L3 which shows [14]

individual phase current values of R-Y-B on first row, second row and third row display respectively. If current (I)<1000 which takes one digit after decimal. Or else, current (I) 1000 which doesn t take any digit after decimal. Page 3 The LED indicators glow on system PF, Hz and active power (KW) which shows their values on first row, second row and third row displays respectively. Page 4 The LED indicator glow on system apparent power (KVA), Reactive power (KVAR) and Active power (KW) which shows their values on first row, second row and third row displays respectively. [15]

Page 5 The LED indicator glows on Total Active Energy (KWh) which shows its value on fifth display. If KWh < 100 which takes two digits after decimal. Or else, KWh 100 which takes one digit after decimal. Page 6 The LED indicator glows on Total Apparent Energy (KVAh) which shows its value on sixth display. If KVAh < 100 which takes two digits after decimal. Or else, KVAh>100 which takes one digit after decimal. [16]

Page 7 The display shows Total Reactive energy (KVARh). If KVARh < 100 which takes two digits after decimal. Or else, KVARh 100 which takes one digit after decimal. Page 8 The LED indicator glows on VOLT which shows individual phase to neutral voltage of R-Y-B on first row, second row and third row display respectively. Freezing and unfreezing the displays The Run Mode Display is in scroll mode by default, i.e. each page is displayed for about 7-8 seconds, after which the next page is automatically shown. To freeze the display at a particular page, press key. The LEDs will start blinking to indicate that the display is frozen. Now it is also possible to go to the next or previous page by using and keys respectively. To unfreeze the display and start autoscrolling again, press key. [17]

Communication UNIT CONNECTED TO RS485 PORT The industrial standard RS-485 communication port option is also available in Empower. This option makes it possible for a user to select Empower to provide power and energy information into a variety of existing or new control systems and communication networks such as EMS/PLS/SCADA. Modbus RTU on RS485 Port In order to download live data for the various system parameters, user can use RS485 connecting to a SCADA or EMS software. Empower supports an RS485 port with MODBUS-RTU protocol. The station ID for every meter is site selectable. The data which can be read using MODBUS query # 3 (Read Holding Registers) is provided in an address map, with the applicable multiplication factors, vide Appendix. Communication line parameters: 9600/8/N/1. The register map is described in Appendix. All addresses are in decimal whose parameters are unsigned long. If illegal address is sent in query or host, try to read more than 32 bytes of data in one query exception message is generated. The parameters name, address and multiplication factor are also mentioned. Reserved values are for future uses which are transmitted as zeroes. Please refer to the address map for the various parameters in Appendix. [18]

Appendix 3 phase 3000-3019 R phase 3030-3049 Y phase 3060-3079 B phase 3090-3109 3000-KVA 3030-KWh Reserved Reserved X100 3002-KW 3032-KVAh Reserved Reserved X100 3004-KVAr 3034-KVARh Reserved Reserved X100 3006-PF 3036-Hz Reserved Reserved X1000 3008-Avg.VLL 3038-Vry 3068-Vyb 3098-Vbr X100 3010-Avg. VLN 3040-Vr 3070-Vy 3100- Vb X100 3012-Avg. Amps. 3042-Ir 3072-Iy 3102-Ib X100 MF DEFINING MULTIPLICATION FACTOR Hz has a multiplication factor of 100 & not 1000. e.g. If Hz is 48.33, and then it is sent as 4833. For providing resolution, all parameters except PT are multiplied with 100 before transmitting. Thus if the KVA value is 278.99, it is sent out as 27899. PF has MF of 1000, instead of 100. Thus, a PF value of 0.987 is sent as 987. If an attempt is made to read some address other than the valid addresses, the exception response is sent. EXPEPTION CODE In the event that the query from the HOST has no communication error, but there is some error in specifying the address of registers to be read, the meter returns an exception message. The format of the exception message will be as under: Unit Address 0X83 Exception code CRC CRC Exception Code can have only one value, 02: if the address is not a valid, start address or host has requested more than 32 bytes of data, this code is returned. [19]

Ordering Options Empower can be ordered with the following options according to your requirements. Empower Power Meter Technical Specification Installation For H.T application ( only if meter is to be used for HT line) CT secondary (Current) Communication Options 3P4W installation 3P3W installation PT-Primary.. KV. PT-secondary..V. 5A 1A RS485 port with Modbus-RTU protocol. None [20]

P.O No. Customer Sr. No. Result of Test Remarks Test engineer Date : : : : : : : [21]