Alignment and Operation

Similar documents
Automatic Tracking Filter for DDS Generator

3.2 Measuring Frequency Response Of Low-Pass Filter :

Keywords: ISM, RF, transmitter, short-range, RFIC, switching power amplifier, ETSI

HF Amateur SSB Receiver

CHAPTER 13 TRANSMITTERS AND RECEIVERS

Kostas SV3ORA's triple crystal oscillator:

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D

Tuning a 160M full sized vertical with strong AM broadcast RF present on the antenna. Jay Terleski, WX0B

ALX-SSB 5 Band Filter Assembly Manual 19 November 2018

Exercise 1: RF Stage, Mixer, and IF Filter

Receiver Design. Prof. Tzong-Lin Wu EMC Laboratory Department of Electrical Engineering National Taiwan University 2011/2/21

Homebrew and Experimenters Group HF Inductance Bridge (Compiled by VK2TOX)

Laboratory Exercise 6 THE OSCILLOSCOPE

Chapter 3. Question Mar No

Technical Shorts. by Gerry O Hara, VE7GUH/G8GUH

The G4EGQ RAE COURSE Lesson 9 Transmitters Lesson 8 looked at a simple transmitter exciter comprising of oscillator, buffer and multiplier stages.

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION (Autonomous) (ISO/IEC Certified) SUMMER 14 EXAMINATION Model Answer

Lab Reference Manual. ECEN 326 Electronic Circuits. Texas A&M University Department of Electrical and Computer Engineering

Understanding RF and Microwave Analysis Basics

MARTIN - G8JNJ ECLECTIC AETHER - ADVENTURES WITH AMATEUR RADIO

10 GHz Microwave Link

Glossary of VCO terms

Definitions. Spectrum Analyzer

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Lab 4. Crystal Oscillator

A.C. FILTER NETWORKS. Learning Objectives

2m Weak Signal Sources January 2018

HF PA kit with built-in standalone raised cosine controller

PN9000 PULSED CARRIER MEASUREMENTS

Module 8 Theory. dbs AM Detector Ring Modulator Receiver Chain. Functional Blocks Parameters. IRTS Region 4

8 Hints for Better Spectrum Analysis. Application Note

Exam Booklet. Pulse Circuits

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

EVALUATION KIT AVAILABLE 10MHz to 1050MHz Integrated RF Oscillator with Buffered Outputs. Typical Operating Circuit. 10nH 1000pF MAX2620 BIAS SUPPLY

Single Conversion LF Upconverter Andy Talbot G4JNT Jan 2009

Some Thoughts on Electronic T/R Circuits

THE 1956 ZENITH ROYAL 500 TRANSISTOR OWL S EYES RADIO.

UNIT-3. Electronic Measurements & Instrumentation

Fourier Theory & Practice, Part II: Practice Operating the Agilent Series Scope with Measurement/Storage Module

A Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09

Chapter 6. FM Circuits

Technical Notes from Laplace Instruments Ltd. EMC Emissions measurement. Pre selectors... what, why and when?

WESTREX RA-1712 PHOTOGRAPHIC SOUND RECORD ELECTRONICS

A Guide to Calibrating Your Spectrum Analyzer

Measuring Non-linear Amplifiers

8 Hints for Better Spectrum Analysis. Application Note

HF Receivers, Part 2

Application Note Receivers MLX71120/21 With LNA1-SAW-LNA2 configuration

Radio Receivers. Al Penney VO1NO

A 3 TO 30 MHZ HIGH-RESOLUTION SYNTHESIZER CONSISTING OF A DDS, DIVIDE-AND-MIX MODULES, AND A M/N SYNTHESIZER. Richard K. Karlquist

ANALOG COMMUNICATION

Experiment 1: Instrument Familiarization (8/28/06)

10MHz to 1050MHz Integrated RF Oscillator with Buffered Outputs

2-Tone Generator For 145Mhz

Experiment 1: Instrument Familiarization

Definitions of Technical Terms

N3ZI Kits General Coverage Receiver, Assembly & Operations Manual (For Jun 2011 PCB ) Version 3.33, Jan 2012

Optical Pumping Control Unit

Building a Bitx20 Version 3

ericssonz LBI-38640E MAINTENANCE MANUAL FOR VHF TRANSMITTER SYNTHESIZER MODULE 19D902780G1 DESCRIPTION

Spectrum analyzer for frequency bands of 8-12, and MHz

4. Digital Measurement of Electrical Quantities

Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed

Measurement of the equivalent circuit of quartz crystals

Application Note SAW-Components

Rigol DSA705 Spectrum Analyzer Reviewed by Phil Salas AD5X

THE AMAZING BARLOW WADLEY XCR-30 CRYSTAL CONTROLLED 30 BAND TRANSISTOR RADIO. (A method to set the AGC) H. Holden, 2018.

Lab 4. Crystal Oscillator

note application Measurement of Frequency Stability and Phase Noise by David Owen

100 Hz to 22. HP 8566B Spectrum Analyzer. Discontinued Product Support Information Only. Outstanding Precision and Capability

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

Applications Note RF Transmitter and Antenna Design Hints

RFID Systems: Radio Architecture

The ROSE 80 CW Transceiver (Part 1 of 3)

1, Bandwidth (Hz) ,

CAVITY TUNING. July written by Gary Moore Telewave, Inc. 660 Giguere Court, San Jose, CA Phone:

MAINTENANCE MANUAL RF BOARD 19D901835G1 ( MHz) 19D901835G2 ( MHz) FOR MVS

The Active Bridge 11/20/09

HOMEBREW Q-MULTIPLIER

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

Lecture 16 Microwave Detector and Switching Diodes

Tuned circuits. Introduction - Tuned Circuits

Lab 10: Oscillators (version 1.1)

1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD...

Electrical Fundamentals and Basic Components Chapters T2, T3, G4

Fabricate a 2.4-GHz fractional-n synthesizer

Technical Bulletin A Versatile Pulse Tester Page 1 of 6

FMC664CC FM BAND CONVERTER

A year and a half after the first introduction of the PXA, Agilent is now introducing the world s highest performance mmw signal analyzer in April

ATUs - ANTENNA TUNING UNITS THE ATU. An Antenna Tuning Unit MAKE YOUR OWN ATU

A COMPACT, AGILE, LOW-PHASE-NOISE FREQUENCY SOURCE WITH AM, FM AND PULSE MODULATION CAPABILITIES

Using the V5.x Integrator

Copyright 2012, R. Eckweiler & OCARC, Inc. Page 1 of 5

Chapter 2. The Fundamentals of Electronics: A Review

Beta-test ED1 PCB installed in I0CG s K1

But this is about practical experiments so lets find out what an inductor is all about.

Knight Kit V44 VFO Stabilized by the Cumbria Design X-Lock 3.0

An Introduction to Spectrum Analyzer. An Introduction to Spectrum Analyzer

Experiment No. 2 Pre-Lab Signal Mixing and Amplitude Modulation

Transcription:

Introduction Spectrum Analyser theory Construction Techniques Power Supply Sweep Generator Logarithmic Amplifier 145 MHz IF Filter 1st Mixer 2nd Mixer 8 MHz IF Filter Low-pass Filter Input Attenuator 10MHz Crystal Calibrator Alignment and Operation The simple man's Spectrum Analyser Alignment and Operation 1 / 10

Final alignment There isn't much to do in the way of final alignment. The simple man's spectrum analyser is designed particularly to avoid any complicated and difficult alignment or construction procedures. The hardest part is getting the 2nd local oscillator tuned to 153MHz, but that has already been taken care of. As a final alignment, the only thing needed is to make sure the tuning range of the VCO is just right. The sweep generator should be outputting the maximum voltage range without clipping, if it has been correctly set as described. Now the oscillator coil in the VCO can be adjusted. The ideal sweep range of the VCO is 145-295MHz, giving analyser coverage of 0-150 MHz. That's actually quite an impressive range. This adjustment is best made with no signal to the analyser. The frequency span control should be set to maximum, and the adjustment made by squeezing or expanding the turns of the air-wound coil in the VCO. It might be necessary to add or remove coil turns, or perhaps very small (pf) capacitors in parallel with the coil. The centre frequency control should be used to view the lower and upper frequency bounds. The 0 MHz spur will be visible at the left of the screen when the lower end of the VCO range is at or below 145MHz. This spur is generated when the VCO 2 / 10

passes through the first IF frequency. Similarly, when the upper end of the range is at or above 295MHz another spur will be generated corresponding to an input frequency of 145MHz. After a lot of fiddling around, if all is Ok both the 0 and 145MHz spurs will be visible on the screen at the same time, as shown in this photograph. When this is the case, by definition the analyser is covering at least the range 0-145MHz. Operation hints In use the spectrum analyser should be easy and intuitive to operate. If the user wants to use narrow sweeps and finds the centre frequency too difficult to set, then a multi-turn potentiometer could be used in the Sweep Generator, or a separate fine-tuning potentiometer adjustment. Of absolutely crucial importance is the input attenuator. This spectrum analyser is by design simple to build and align, the use of the SA602 IC is particularly beneficial in this respect. However the SA602 does suffer from limited strong signal handling performance which can cause many spurious signals in the analyser in the presense of large input signals. This is a penalty of using such a simple design. Yet with careful use, this limitation need not prevent the analyser from being extremely useful and making great observations. It is usually easy to identify spurious signals by switching in a little attenuation. The amplitude of the true signals will change by the expected amount according to the selected attenuation, whereas the spurious responses will appear to be reduced in amplitude by a larger amount. Sometimes this effect is quite marked: just switching in 1dB of attenuation which hardly affects the true signals has a drastic effect on the spurii. If the input signal is strong enough to cause spurious responses I usually select attenuation such that all the spurious responses dissappear. Obviously switching in attenuation also reduces the signals you do want to see. Sometimes weak frequency components could drop below the noise floor. So it may be desirable to use less attenuation than would be necessary to remove any spurious responses altogether. In this case it is often useful to temporarily use larger attenuation in order to identify any spurious responses present. Another way to identify some spurious responses, is by tuning the centre frequency. For example as you increase the centre frequency, the spectrum will scroll towards the left of the display. However, some peaks might move to the left much faster than the main "true" peaks, or even move in the opposite direction! These peaks are the result of residual high harmonics which make it through the input low pass filter. For transmitter testing, a short piece of wire connected to the analyser input is sufficient to show 3 / 10

the output spectrum. But for accurate measurements you need to make a proper connection between the transmitter and the spectrum analyser. Unless the transmitter is extemely low power (mw) the spectrum analyser input will be overloaded and most probably damaged. Therefore you would need a power attenuator, providing say 20dB attenuation (or more for a QRO transmitter) and of appropriate wattage rating. The high impedance input is more sensitive and vulnerable to damage than the 50-ohm input and accordingly care should be taken. I managed to destroy a MAX4178 amplifier IC by unplugging the signal generator while it was switched on. Since my signal generator is an old Heathkit type using valves, high voltages are present and I suspect that the earth connection was broken before the inner coaxial signal connection, resulting in a large DC bias on the signal input. I find it useful to normally use the 50-ohm input and only switch in the high impedance input when it is needed. Resolution Bandwidth By close in observations on the signal generator output and switching in different attenuations I have been able to approximately determine that the resolution bandwidth of this spectrum analyser is about 200KHz. In analyser specifications this is defined as the point at which adjacent signals can be separated with a 3dB dip between their peaks. The resolution bandwidth is completely dependent on the characteristics of the 2nd IF filter. In my case, I used ceramic resonator filters from the junk box having unknown characteristics. Certainly filters are available (e.g. 10.7MHz) with narrower bandwidths than this. Alternatively crystal filters could be used. A future version of the spectrum analyser will include several 2nd IF filters with different bandwidths, selectable via a front panel switch. 4 / 10

Frequency axis linearity Precise linarity of the frequency axis is hard to achieve in such as simple design. Any VCO using a varicap diode for tuning will exhibit some non-linearity. The reverse capacitance of varicaps is not linear with applied voltage, nor is the the VCO frequency linear with capacitance. Given these inherent limitations I am extremely surprised at the excellent linearity shown by this circuit. The photograph (right) shows the spectrum of the internal 10MHz crystal calibrator oscillator 5 / 10

over the range 0-100MHz. Some non-linearity is visible at the right of the display but in general the linearity is very good. Always suspicious of my cheap 5Mhz Kenwood oscilloscope, I decided to try the same trace but swap the oscilloscope X and Y connections. Because of the scales of the voltages involved and the considerably lesser amplification available on the oscilloscope X input, the size of the peaks in this mode is smaller (see photo, left). The experiment shows that the frequency axis linearity is greatly improved. This means that much of the non-linearity visible in the normal trace is due to imperfections in the oscilloscope rather than true non-linearity in the spectrum analyser. To further illustrate this point and make a nice comparison - here's an experiment with the frequency linearity over the whole frequency coverage 0-140MHz. The photograph below left shows the spectrum from 0-140 MHz of the 10MHz calibration oscillator. Below centre is the same trace, with the X and Y inputs swapped. Below right: the digitally remastered composite image. Here I used Microsoft PhotoEditor to remove the axis tilt and size the pictures to the same scale. The upper trace is the normal configuration, the lower half is the X-Y swapped version. Here it's clear to see that the linearity of the oscilloscope X axis is questionable. 6 / 10

7 / 10

Other Oscilloscope problems You can't fail to have noticed the annoying upward slope of the baseline from left to right, in all the oscilloscope photographs. Is this a problem in the analyser or another 'scope defect? Quite possibly the response of circuits in the analyser could create this effect, indicating a design fault. Fortunately this one is easy to blame on the 'scope: the upward slope is present even when the spectrum analyser is disconnected. I am developing a new spectrum analyser which uses digital storage and a 4.5-inch television tube for the display. This photograph shows the display section of the new project, connected to the output of this spectrum analyser. The spectrum of the 10MHz calibration oscillator is being displayed, the frequency range is about 2-42 MHz. The baseline is perfectly horizontal against the digitally generated graticule. Some more screenshots Here's a few more examples. Left: 10MHz calibration oscillator spectrum, 8-32 MHz showing fundamental at 10MHz, with 2nd and 3rd harmonics. Note the very much reduced amplitude of the 2nd harmonic. In a perfect square wave oscillator there are no even-order harmonics. The output of the calibrator approximates a 10MHz square wave which is why the even harmonics are always much lower in these photographs. Centre: Closeup on the 10MHz peak, showing the shape of the 2nd IF filtering. Right: spectrum of my Heathkit signal generator tuned to approximately 1MHz. The even-order harmonics are of lower amplitude but still visible out to about 40MHz. 8 / 10

9 / 10