Identify extraneous chemicals that contributed towards the failure of actuating mechanism in inner vial

Similar documents
Beeswax adulteration issue: aspects of contamination and outcome

INFRARED ANALYSIS OF SINGLE AND MULTILAYER FILMS IN THE PRODUCTION AREA

Philippa Eshun. Lincoln Leadership Academy Charter School (Allentown, PA)

Damage-free failure/defect analysis in electronics and semiconductor industries using micro-atr FTIR imaging

Material analysis by infrared mapping: A case study using a multilayer

Infrared Microscope. Dedicated AIMsolution Software. Hisato Fukuda. 1. Introduction. 2. Automatic Contaminant Recognition Function

Installation and User Guide. FlexIR TM NIR Fiber Optic Accessory

INGEDE Project PMV Entrance Quality Control of Recovered Paper Regarding Deinkability of Printed Products by FT-IR Spectroscopy

Development and Applications of a Sample Compartment FTIR Microscope

FTIR microscopy and imaging for failure analysis in electronics manufacturing

Characteristics and Applications of Imaging Microscope FT-IR. Teo Wei Boon PerkinElmer Singapore

Welcome to Today s Webinar

Vol. Validation of FTIR Systems AIM-9000 Infrared Microscope Infrared Microscope. Convenience of a Wide-View Camera

An Investigation of Synthetic Body Covering Materials in Soil Burials for Forensic Application

Preparation and evaluation of demulsifiers agents for Basra crude oil

November 17, Mr. Jeffrey Fuller Fuller Fine Art Auctions 730 Carpenter Lane Philadelphia, PA Dear Mr. Lawrence:

Technical Procedure for Infrared Spectroscopy

NIR SPECTROSCOPY Instruments

We are reliable distributors of industrial pigments, dyes, colors and additives representing several reknowned international principals and provides

UNCLASSI FIED 4;0LO68, DEFENSE DOCUMENTATION CENTER FOR SCIENTIFIC' AN D TECHNICAL INFORMATION CAMERON STATION. ALEXANDRIA, VIRGINIA UNCLASSIFIED

Agilent 4300 Handheld FTIR Spectrometer AT-SITE. IMMEDIATE RESULTS. TRUE NON-DESTRUCTIVE ANALYSIS.

FTIR Microscopy and Imaging

WHITE PAPER MINIATURIZED HYPERSPECTRAL CAMERA FOR THE INFRARED MOLECULAR FINGERPRINT REGION

- OVERVIEW Introduction of plastic tealight cups a trip back in time.

The FTNIR Myths... Misinformation or Truth

Creating Barriers Repellent Finishing for Medical & Protective Apparel. Melanie P. Jones Operations Supervisor Precision Fabrics Group, Inc.

Project #76: Self-Centering Motor Housing Design Proposal

Diamond Analysis. Innovation with Integrity. Reliable identification and type determination by FTIR spectroscopy FTIR

CHAPTER-V SUMMARY AND CONCLUSIONS

Spectrum 400. FT-IR and FT-NIR Spectrometer. There is only one answer.

Possibility of Identifying Treated and Non-treated Sri Lankan Ruby and Sapphires by FT-IR Spectroscopy

DRUG CONTAINER CLOSURE TESTING: IMPACT OF EXTRACTION AND ANALYSIS METHODOLOGY ON METAL CONTAMINANT QUANTIFICATION

Seized Drugs Operational Guidelines for the Thermo FTIR Comparative and Analytical Division

N-Methyl-1-(6-methylpyridin-2-yl)propan-2-amine

CHM 130 Paper Chromatography

TRACE EVIDENCE ANALYSIS UV-VIS-IR MICROSPECTROMETRY POLARIZED LIGHT MICROSCOPY

Beverage industries use coldrolled

Enameled Wire Having Polyimide-silica Hybrid Insulation Layer Prepared by Sol-gel Process

Refined from crude oil, has relatively low melting point (50-70 C) and relatively brittle. Refined from petroleum, has medium melting range (60 C).

Mould Sprays 49

Infrared Microscope AIM-9000 C103-E103B

Analytical Chemistry in Forensic Science spectral imaging

DRY-CLEANING, WASHING OR BLEACHING FIBRES, FILAMENTS, THREADS, YARNS, FABRICS, FEATHERS OR MADE-UP FIBROUS GOODS; BLEACHING LEATHER OR FURS

) Forensic Footwear and Tire Impression Evidence. t the form of a three-dimensional shoe impression

5-2 Terahertz Spectroscopy for Non-Invasive Analysis of Cultural Properties

PAPER AND CARD PACKAGING DESIGN TIPS FOR RECYCLING

PET SHEETS PERFORMANCE CHEMICALS

Technological Innovation of Inspection Equipment for Effective Border Control in Japan. Noriaki Oka

DAP 33 Window Glazing

Spectroscopy Application: Using Raman Spectroscopy to Detect Art Forgeries Detecting art forgeries using Raman spectroscopy

SWS SWS62221 Spectral Sensor. General Description. Block Diagram

TRANSFORMER MANUAL. Bérkel Acrylic Mirror

Hangzhou Bili Rubber & Plastic Co., ltd

Agilent 8700 LDIR Chemical Imaging System. Bringing Clarity and Unprecedented Speed to Chemical Imaging.

Experiment 6: Paper Chromatography

December Fourier Transform and Apodization ABC of the FTIR Measurement Methods: Liquid Membrane Method Question --- 9

RDIT19_12 Cacia. Caustic soda contamination Preliminary report_24/04/2012

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

BANKNOTE CHARACTERIZATION USING THE FTIR SPECTROSCOPY

Advancing FT-IR Imaging Synchrotron IR Imaging in Your Lab. Dr. Mustafa Kansiz FTIR Microscopy & Imaging Product Manager

Industrial Waxes Chemistry & Blending

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

Bareco Products. Introduction to Petroleum Waxes

Influence of Photo-illumination on Greenish Metallic Luster of Safflower Red Pigment Film

Color More than meets the Eye

Fourier Transform Infrared Spectrophotometer. IRAffinity-1S C103-E096C

Red lake pigments: linking analytical results to the recipes

TECHNICAL INFORMATION. HARD-CORE Tire and Footprint Casing Kit Catalog No. 639HCB

Eliminating A Common OCC Stickies Problem

NEW PIGMENT PASTE FOR LEATHER FINISHING

FTIR Spectrophotometer

UV Beads Summary: In this activity we will: Materials:

Standard Opening Screw Thread Vials, 12x32mm, 8-425mm Neck Finish

Metal coatings analysis using the handheld Agilent 4100 ExoScan FTIR

INFLUENCE OF PRINTING SPEED AND RADIATION DOSE ON THE CURING OF UV INKS AND VARNISHES

DAP Latex Window Glazing

Glass & Plastic Containers

Thermo Scientific HyClone Powdertainer TM II and Filling Stand

Paint Analysis Test No Summary Report

Designated Raw Materials and Environmental Assurance Data. Supplier Relations Department Procurement Center May, 2007

International Journal of Pharma and Bio Sciences PROCESS ANALYTICAL TECHNOLOGY IMPLEMENTATION- PROGRESSION FOR A PHARMACEUTICAL INDUSTRY ABSTRACT

PYROELECTRIC PASSIVE INFRARED SENSOR

Supporting Information

Fourier Transform Infrared Spectrophotometer. IRTracer-100 C103-E091B

Analytical Cumulative Exam November 21, 2008

Making a Surface Coating Kersti Cox, Miami University, Oxford, OH

TURTLE WAX COMPOUND & POLISHING SYSTEM TURTLE WAX PUTS THE SHINE BACK

Rapid Quantification of the A:B mixratio of a 2K Industrial OEM PU paint prior to autoclave thermal activation

Appendix C. Example Science Items. Grade 4 and Grade 8

Using the scientific equipment at the Smithsonian National Postal Museum

Sumitomo Seika Chemicals Company, Limited

Void Reduction in Reflow Soldering Processes by Sweep Stimulation of PCB Substrate

TALL OIL PITCH AS BITUMEN EXTENDER

Fourier Transform Infrared Spectrophotometer. IRAffinity-1S C103-E096

Flash chromatography. MN Flash adsorbents a unique variety of phases. Separation efficiency and reproducibility

Discrimination of Single White Layer Architectural Paints

Identification of Textile Fibres by means of Pyrognostic Analysis

CONVERTING RECLAIMED SCRAP PET TO USEFUL PROCESS CHEMICALS

Fourier Transform Infrared Spectroscopy

Abstract No. 32. Arne Bengtson and Tania Irebo. Swerea KIMAB AB, Isafjordsgatan 28A, SE Kista, Sweden

Transcription:

Identify extraneous chemicals that contributed towards the failure of actuating mechanism in inner vial By Vishu Shah Consultek 460-D West Lambert Road Brea, CA 92821 1

Identify extraneous chemicals that contributed towards the failure of actuating mechanism in inner vial Objective: The second aging study of the Clicker assemblies had exhibited a failure rate of 2.5%. In the failed two samples, actuating mechanism did not activate during first try. This study was undertaken to identify if there is any chemical compound that was present on the gears that could have contributed to the failure of the actuating mechanism. Background: It was hypothesized that there was a waxy substance that came from PE bags and/or HDPE components such as HDPE cap, and after aging study caused gears to become gummy. To test this hypothesis, a chemical analysis was done using hexane wash and FTIR analysis. These techniques were chosen for the following reasons: A. Various polymer additives can be extracted with high recovery efficiency using hexane from polymer surfaces by using room temperature extraction surface wash technique. In addition, Hexane is also inert towards ABS, PC and PE compounds as well as anticipated additives such as waxes and silicone oils, and therefore would not attack the components. B. Thereafter, FTIR (Fourier Transform Infrared) spectroscopy was applied to analyze and identify the different types of organic as well as many inorganic compounds that were present in the hexane wash. FTIR was chosen since it is one of the most powerful analytical chemistry instruments that is used to identify and quantitatively analyze additives that are present in plastics. Pure organic molecules give identical IR spectra. Hence, the IR spectrum of a material can be used as a "fingerprint" for identification purposes by comparing spectra of known database references to the sample spectrum. By comparing standard IR spectra of the known additive with unknown, it was hypothesized that the presence of additive could be identified that may have contributed towards the gummy behavior of actuating mechanism. Collection of samples and analysis: Reference gear samples (virgin molded part), gears from the failed samples in the second aging study and HDPE cap (also from aging study) were collected and subjected to the following analysis to determine the root cause of failure. Analytical test: All samples were washed using Hexane and collected hexane was subsequently subjected to IR analysis. 2

Result of FTIR Spectra: Analytical tests conducted by Seal Laboratories involved washing reference gear samples, gear samples from aging study and HDPE cap with hexane, collecting the solution and analyzing it using Fourier Transform Infrared (FTIR) technique. FTIR results indicated that both gears from the aging study as well as the reference gears had amide wax on them. Also, silicone was present on the reference gears. However, amide wax was not present on the inside of the HDPE cap. For details, please refer to appendix. Conclusions: A. Amide wax was definitely a contributing factor that caused actuating mechanism to become sticky. The mechanism that caused the amide wax to become a contributing factor was due to the fact that amide wax 1 melted during the aging study (higher temperatures) and became softer and then migrated onto the gears, thereby contributing to gumminess of the actuating mechanism. B. Hexane wash and subsequent FTIR analysis of HDPE cap proved that amid wax was not present and/or did not come from the cap. Recommendations: A. Further investigation should be carried out to see whether or not there is any amide wax that is present on the implant (from the aging study) and the clinical implications of having wax on the implant. There is a possibility of secondary migration of amide wax on to the implant due to higher aging temperatures and/or due to higher temperature packaging is exposed to during storage or transport. B. Molder should be instructed not to use silicone mold release agent to eject the parts from the mold. C. FDA approved PE bags should be used for transportation of parts. 1 Amid wax is used as an external lubricant in manufacture of PE film and bags and therefore, it could only come from Polyethylene bags that were used to package and ship molded parts. 3

Appendix: Raw results of FTIR Analysis Sample gear: SEAL Laboratories.12 Hexane Wash of Black & Clear Gears from Sample #1 80273-1.1 Absorbance.08.06.04 Amide Wax Reference.02 0 3500 3000 2500 2000 1500 1000 Wavenumber (cm-1) In this figure, the spectrum of the hexane wash from the Sample #1 gears is compared to a reference amide wax spectrum. The spectra are identical with identical peak positions (wavenumber positions) and peak shapes and heights. The residue from the hexane wash of the Sample #1 gears is an amide wax. 4

Reference gear: SEAL Laboratories.1 Hexane Wash of Reference Black & Clear Gears 80273-2.05 Absorbance 0 -.05 Amide Wax Reference -.1 -.15 3500 3000 2500 2000 1500 1000 Wavenumber (cm-1) In this figure, the spectrum of the hexane wash from the reference gears is compared to a reference amide wax spectrum. This spectrum contains the amide wax spectrum but also contains peaks from presence of silicone. 5

Reference Gears Reference Silicone In this figure, the spectrum of the hexane wash from the reference gears is compared to a reference silicone spectrum. The residue from the hexane wash from the reference gears is a mixture of amide wax and silicone. 6

HDPE cap: SEAL Laboratories.04 1088 1022 2967 2923 2857 803.03.02 1261.01 0 -.01 3000 2000 1000 Hexane wash of PE Cap shows absence of Amide Wax and presence of silicone. 7