Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Similar documents
Zeiss 880 Training Notes Zen 2.3

LSM 510 Meta Training Notes

LSM 510 Training Notes

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

LSM 710 Confocal Microscope Standard Operation Protocol

Zeiss 780 Training Notes

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

LSM 780 Confocal Microscope Standard Operation Protocol

LSM 800 Confocal Microscope Standard Operation Protocol

ZEISS LSM510META confocal manual

Leica SP8 TCS Users Manual

Microscopy from Carl Zeiss

Guide to Confocal 5. Starting session

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

1 Co Localization and Working flow with the lsm700

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Operating Instructions for Zeiss LSM 510

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Zeiss LSM 880 Protocol

Practical work no. 3: Confocal Live Cell Microscopy

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Internal Medicine Imaging Core Emory University Department of Medicine

Zeiss LSM 780 Protocol

Leica Sp5 II Confocal User Guide

OPERATING INSTRUCTIONS

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

Leica SP8 TCS Users Manual

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

Quick Start Guide. Leica SP5 X

User manual for Olympus SD-OSR spinning disk confocal microscope

Supplemental Method Information Zeiss LSM710

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Title: Leica SP5 Confocal User Manual

The Zeiss AiryScan System, Confocal Four.

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Swept-Field User Guide

CONFOCAL MICROSCOPE (Zeiss LSM 510 META v4.2)

b. Turn the power switch and key to on position for blue laser.

Leica TCS SP8 Quick Start Guide

Leica SP8 Resonant Confocal. Quick-Start Guide

Things to check before start-up.

Microscope Confocal Sp2 Upright.

Leica TCS SP8 Quick Start Guide

Microscope Confocal LSM510 META

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Zeiss LSM880 Operating Instructions. UTMB Optical Microscopy Core Jan. 16, 2018

Confocal Microscopy. Kristin Jensen

Comparing FCS and FRAP as methodologies for calculating diffusion

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Use of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK

TRAINING MANUAL. Olympus FV1000

3D light microscopy techniques

CCAM Microscope Objectives

CCAM s Selection of. Zeiss Microscope Objectives

1 Set up the confocal light path for imaging a green dye (Alexa488-EGFP). For example, the

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

Zeiss LSM 510 Multiphoton Confocal Microscope

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

Multifluorescence The Crosstalk Problem and Its Solution

Zeiss LSM 510 Multiphoton Confocal Microscope

Topics. - How to calibrate the LSM scanner. - How to clean the microscope. - How to adjust the pinhole alignment. - How to adjust the Collimator

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Application Note. The New 2D Superresolution Mode for ZEISS Airyscan 120 nm Lateral Resolution without Acquiring a Z-stack

Figure 1. Oil-immersion objectives available for use with the Lionheart FX.

REMEMBER: You have 5GB of disk space on this microscope. Check before you start if you have room for your experiment. If not delete your old data.

Fundamentals of Digital Imaging. Dr Paul McMillan Biological Optical Microscopy Platform

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Contents. Introduction

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

CMI STANDARD OPERATING PROCEDURE. Fluoview 300 laser scanning confocal microscope

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

a) How big will that physical image of the cells be your camera sensor?

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

LSM 510 META in Chang Gung University

Diskovery Spinning Disk Guide

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

Invitation for a walk through microscopy. Sebastian Schuchmann Jörg Rösner

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands

Cell Biology and Bioimaging Core

Point Calibration. July 3, 2012

Nikon Instruments Europe

User Guide to the IBIF Leica TCS SP8 MP Confocal Microscope

ZEISS LSM 710 NLO Multiphoton microscope Manual/Quick guide

Title: Nikon A1R Confocal User Manual

Confocal Application Notes Vol. 5 July 2010

ScanArray Overview. Principle of Operation. Instrument Components

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.

Transcription:

Bi/BE 227 Winter 2016 Assignment #3 Adding the third dimension: 3D Confocal Imaging Schedule: Jan 20: Assignment Jan 20-Feb 8: Work on assignment Feb 10: Student PowerPoint presentations. Goals for this week A. Collect 3D Confocal data set: Z-stack. B. Document effects of refractive Index mismatch C. Determine linear range for Detectors at different gains. D. Measure laser power. Samples A. Carolina sample slides with pollen grains. Clean off oil with OptiPad after use. B. Carolina sample slides with pollen grains. Clean off oil with OptiPad after use. C. Autofluorescent plastic slides from Chroma Technologies. INSTRUCTIONS: A. Single channel 3D imaging of Carolina pollen slides. (40x oil, or 63x oil objective) Before starting any 3D acquisition, read the section Considerations for Z-sectioning at the end of section B. A1. Find Settings for 3D Imaging Collect Z-stacks of Pollen grains by exciting with either the 488nm, 543 nm or the 633 laser. Compare stacks collected with different intervals (~50% overlap versus larger intervals). Q1: What happens as you image deeper into the specimen? Are the optimal brightness and contrast settings the same for the entire stack? Can you get all of the way through the specimen? A2. Compare Effect of Pinhole Aperture Acquire two Z-stacks of the same sample (Carolina pollen grain) with different pinhole size settings (wide open, and ~1 Airy unit), adjusting the intensity, exposure time, brightness, and contrast such as to fill the whole dynamic range. Make sure to record your X-scale, Y-scale, and Z-interval values; visualize the sample in 3D using the Zeiss software or FIJI (Image J) software. Q2: What is the effect of changing the pinhole size on the 3D renderings?

B. Single channel 3D imaging of Carolina pollen slides. (40x dry and then 40x oil objective) Before starting any 3D acquisition, read the section Considerations for Z-sectioning at the end of this section. B1. Acquire Z-stacks using optimal settings as determined in A2. Collect Z-stacks of Pollen grains by exciting with either the 488nm, 543 nm or the 633 laser and the pinhole set at 1 Airy unit. Make sure that several round spiky pollen are in your field of view. Collect enough optical sections at a small Z-interval (smaller than your Z-section thickness in microns, see below regarding typical objectives). Use the Dry object first and then collect a comparable stack using the oil objective. NOTE: Z interval will be smaller and there may be more sections with the oil objective. B2. Compare Z-stacks taken with dry and oil objectives. Compare the Z-stack collected with a dry objective to the one collected using an oil objective in 3 dimensions using the Zeiss confocal software or FIJI. Look at the round pollen in 3D, observing its shape in different planes. Compare the shape in the X-Y plane to cross sections in the X-Z or Y-Z planes. Q3: How does the shape of the pollen differ between dry and oil objectives? What do you think the refractive index of the material the pollen grains are embedded in is most similar to? Considerations for Z-sectioning PLEASE BE CAREFUL: Watch out for clearance of the objectives! It is very important that you do not plow the objective into the coverslips. Adjust the focus slowly and watch for and avoid contact with the coverslip. Be careful that your z-stack is not too large to cause the objective to slam into the coverslip toward the end of the stack. Choosing Top and bottom boundaries of a Z-stack. There are a couple ways to set this parameter: The best Z-stacks are collected using optimal intervals. Sections spaced too far apart will leave gaps. Sections placed too close means oversampling and bleaching due the excessive illumination. These best intervals are ~50% of the thickness of the optical slice that you are collecting. Remember that the thickness of the optical slice is related to the NA of the objective and the size of the pinhole used. Below are listed the approximate thickness of optical sections collected with our objectives. All @ pinhole = ~1 Airy unit Objective: 40x Air (NA=0.75) Optical section thickness = 1.7μm interval for Z sectioning = 0.84 μm Objective: 40x Oil (NA=1.3) Optical section thickness = 0.8 μm Optimal Optimal interval for Z sectioning = 0.41 μm

Objective: 63x Oil (NA=1.4) Optical section thickness = 0.7 μm Optimal interval for Z sectioning = 0.35 μm Choosing Top and bottom boundaries of a Z-stack There are few options to set this parameter: 1. Do it by eye. Using epifluorescence or a fast LSM scan - focus down and up. Note the Z- position at bottom on the parameter windows. Then focus up until you get slightly above the specimen region of interest and note that Z position. Leave the scope focus at that top position. Make sure that you designate your current section position to 1. Then figure the total size of the stack you want to collect and divide by the interval to get the number of sections, add 1 and put that information into the dialog box for number of sections. Then start the Z-stack collection and it should go from the top ->down to the bottom that you selected (one section at a time). 2. Software based boundary setting. Click on the Z-scan radio button. The scope will do a fast vertical scan. Then it will display this vertical scan with the current focus position in a dotted line and the top and bottom (as shown in the Z section dialog box) as solid lines. The user can move the top and bottom boundaries accordingly. NOTE: Be aware that the software isn t intelligent and it will change the interval size as you move the top and bottom boundaries. So you will have to go back and change the number of sections in order to get you desired interval. There isn t a way to keep the interval parameters constant while changing the boundaries. Final Note: The output from a Z-stack is going to be a series of images. Make sure you save the

output to a folder or you will have a mess on your data disk. Z Sectioning in Zeiss software Z Interval: Step size in microns Number of Sections: User defined based on sample size. Current Section Pos: Take care to always make sure that you are at the beginning of your stack Refractive Correction: N2/N1 (Example: Oil/Water =1.518/1.0= 1.518) Destination: Video Memory: internal video memory buffer, do not use. File: Use this option Screen: Display only one image on the image screen Host Memory: Save into computer s RAM, must be saved through the File menu. Z-Scan: Line Scan through your sample at the center of the image window. Users can define boundaries for z-sectioning through the use of this function. NOTE that adjusting the top and bottom boundaries will change the interval size; you ll have to readjust it. Move to X: Single scan at first, middle, or last positions. Ok: starts the image acquisition. C. Determine the linearity of different Confocal detectors. For this assignment you will compare a detector (PMT) of one of the confocal microscopes in the 68 Church to the GaAsP detector in the LSM 800 in the Biological Imaging Facility (BIF). C1. Plot gain versus intensity for a PMT (LSM 410 or 310). Using the autofluorescent slide from Chroma that matches your laser wavelength use the 488 nm or 543 nm laser line and focus on the very bright slide. Use the 20x objective with 0.8 NA that will be provided. Place the pinhole at 1 airy unit to achieve an optical section. Start at the highest gain and measure the intensity of a typical point in the image. Now decrease the detector gain and measure the pixel intensity again. Repeat several times until you have enough values for a good X-Y plot. Plot the gain versus the pixel intensity on a graph. NOTE: you have to add the 20x 0.8 NA objective to the objective parameter in the Zeiss confocal software. Q4. How linear are the PMTs? How broad is the linear range? C2. Plot gain versus intensity for a GaAsP detector (LSM 800).

NOTE: GaAsP detectors are very light sensitive so be very careful to start with very low laser power! Use the same laser line you used for the PMT or as close as you can get (488 nm may be best). Use the 20x lens with 0.8 NA already on the microscope. Again place the pinhole at 1 airy unit. Raise the gain to maximum and measure the intensity of a typical point in the image. Lower the gain and measure the pixel intensity again. Repeat several times until you have enough values for a good X-Y plot. Plot the gain versus the pixel intensity on a graph. NOTE: the gain on the LSM 800 will not go below 500. Q5. How linear are the GaAsP detectors? How do they compare to a PMT? D. Learn how to measure laser power. You will use the X-Cite Power Meter (Model No. XR2100) with the slide shaped detector to measure the laser power right where your specimen is positioned on the microscope. D1. Measure power of all laser lines on one of the LSM 410s. We will use the confocals with inverted microscopes for this exercise. Again you will use the 20x objective with 0.8 NA. Measure the laser power with different pinhole size settings (wide open, and ~1 Airy unit). One of the LSM 410s has a Krypton-Argon laser with 4 lines while the other LSM 410 has an Argon laser with 2 lines. When measuring laser power make sure the hardware and attenuation are the same for all lines being measured. Try and raise the laser power to near maximum. Q6: Do the different lines on the same gas laser have similar power? D2. Measure power of all laser lines on the LSM 800. All the lasers on this system are solid state instead of gas as on most of the laser lines measured above. Note: the 633 nm on the LSM 410 is the only exception. NOTE: Turn down the detector gain to zero to avoid damaging the detectors! Raise the laser power to near maximum for conducting your measurements. Q7: How does the power of the lasers on the LSM 800 compare to those on the LSM 410? Assignment presentation: You can work in groups. Only oral presentation is required. Just make sure to specifically indicate the answers to the questions somewhere on a slide. Answer Qs and present select images illustrating the topics and tasks covered in this assignment. Use the Zeiss confocal software or ImageJ/Fiji to visualize your data and select images. Explore the various ways to visualize and analyze your data, for example: single-plane view; z-projection (average, maximum intensity); orthogonal-plane views in xy, yz, or xz. Remember to annotate all of the presented images, with relevant imaging parameters, descriptions of the sample, scale bar, visual aids (eg arrows pointing to feature that you want to highlight), etc. Discuss any problems and successes you had during imaging.

Optimal spatial sampling and resolution (From Assignment 1): The optimal spatial sampling density (i.e. size of pixel in the lateral xy plane, and thickness of axial z-section) depends on the optical resolution of the imaging setup. Under-sampling leads to loss of information; over-sampling leads to excessive illumination and unnecessary photobleaching and phototoxicity. The so-called Nyquist s criterion states that the minimal sampling frequency, for no loss of information, is twice of the highest frequency present in the signal. Applied to imaging, this means that if the microscope has resolutions of d_lateral and d_axial, then optimally one should have a lateral pixel of size of (d_lateral/2) and z- sections separated by (d_axial/2). (The ideal factor of 2 in Nyquist s criterion becomes 2.3 for a real microscope, due to certain practical considerations.) The resolution of the microscope could be estimated by the following formulas: d_lateral 0.6*(λ)/NA d_axial 1.6*n*(λ)/NA2 where λ=wavelength (of the fluorescence), NA=numerical aperture, n=refractive index of immersion medium. Using these expressions, you could calculate what optimal voxel size (lateral and axial) you should use. Tο reach the axial resolution stated above, the pinhole has to be set at 1 Airy unit. Example: Objective: 63x Oil (NA=1.4) For fluorescence ~ 575um, pinhole = 1 Airy unit: Lateral resolution = 0.25 um Axial resolution = 0.7 um Using the ideal Nyquist s criterion to determine sampling frequency: pixel size (X,Y) ~ 0.12 um Interval for Z sectioning = 0.35 um (In practice, you over-sample by a further 30-50% if you want a really nice image, and you under-sample by up to 100% if you re concerned about photodamage/imaging speed.) The Zeiss LSM software automatically calculates the resolutions described in the above expressions, for a given objective lens. Click on the radio button next to pinhole slider in the main control window, which would bring up a control window for the pinhole, then click on theradio button labeled Resolution info, toward the lower right corner of the window. You should get a window listing the expected lateral and axial resolutions, for the pinhole size and the lens in use (make sure the software lists the correct lens being used), at the listed excitation and emission wavelengths.