Lab 8 6.S02 Spring 2013 MRI Projection Imaging

Similar documents
2015 Spin echoes and projection imaging

6.S02 MRI Lab Acquire MR signals. 2.1 Free Induction decay (FID)

(N)MR Imaging. Lab Course Script. FMP PhD Autumn School. Location: C81, MRI Lab B0.03 (basement) Instructor: Leif Schröder. Date: November 3rd, 2010

Background (~EE369B)

k y 2k y,max k x 2k x,max

A Conceptual Tour of Pulsed NMR*

Your first NMR measurement

MAGNETIC RESONANCE IMAGING

H Micro-Imaging. Tuning and Matching. i. Open any 1H data set and type wobb.

NMR Basics. Lecture 2

EE225E/BIOE265 Spring 2012 Principles of MRI. Assignment 7. Due March 16, 2012

MRI Summer Course Lab 2: Gradient Echo T1 & T2* Curves

Pulse Sequence Design and Image Procedures

User manual Bruker DPX200 NMR spectrometer

Gradient Spoiling. Average balanced SSFP magnetization Reduce sensitivity to off-resonance. FFE, FISP, GRASS, GRE, FAST, Field Echo

RAD 229: MRI Signals and Sequences

1D Transient NOE on the Bruker DRX-500 and DRX-600

H 2 O and fat imaging

MRI: From Signal to Image

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

EE225E/BIOE265 Spring 2011 Principles of MRI. Assignment 6 Solutions. (y 0 + vt) dt. 2 y 0T + 3 )

SIEMENS MAGNETOM Skyra syngo MR D13

Encoding of inductively measured k-space trajectories in MR raw data

4 Experiment 4: DC Motor Voltage to Speed Transfer Function Estimation by Step Response and Frequency Response (Part 2)

Pulse Sequence Design Made Easier

HETERONUCLEAR IMAGING. Topics to be Discussed:

MR in RTP. MR Data for Treatment Planning: Spatial Accuracy Issues, Protocol Optimization, and Applications (Preview of TG117 Report) Acknowledgements

PHY3902 PHY3904. Nuclear magnetic resonance Laboratory Protocol

MR in Tx Planning. Acknowledgements. Outline. Overview MR in RTP

IR/SR TrueFISP. Works-in-Progress package Version 1.2. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B.

RF Pulse Toolkit: Application Specific Design

RF pulse design and the Small Tip Angle Approximation

Student Name: Date Completed: Supervisor:

Study of the HD target spin rotations during G14

Image Quality/Artifacts Frequency (MHz)

Ultrahigh-resolution Total Correlation NMR Spectroscopy

EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 3. x 2 + y 2 0

Pulse Sequences: Rapid Gradient Echo

An NMR Caveman s Guide to Quickly Acquiring Spectroscopic Data By Brian Sparling

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

Chapter 2. The Physics of Magnetic Resonance Imaging

1 Introduction. 2 The basic principles of NMR

Spiral MRI on a 9.4T Vertical-bore Superconducting Magnet Using Unshielded and Self-shielded Gradient Coils

Time-Varying Signals

EE469B: Assignment 2 Solutions

RC and RL Circuits Prelab

Voltage Current and Resistance II

Exercise 2-6. Target Bearing Estimation EXERCISE OBJECTIVE

Supplementary Material

SpinCore RadioProcessor LabVIEW Extensions

Fire CR Calibration Guide

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

2014 M.S. Cohen all rights reserved

Module 2. Artefacts and Imaging Optimisation for single shot methods. Content: Introduction. Phase error. Phase bandwidth. Chemical shift review

EE 4314 Lab 3 Handout Speed Control of the DC Motor System Using a PID Controller Fall Lab Information

In a typical biological sample the concentration of the solute is 1 mm or less. In many situations,

EE225E/BIOE265 Spring 2014 Principles of MRI. Assignment 6. Due Friday March 7th, 2014, Self Grading Due Monday March 10th, 2014

Nuclear Magnetic Resonance (NMR)

The Agilent OneNMR Probe

Works-in-Progress package Version 1.0. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B. January 22, 2003

Reference Sources. Prelab. Proakis chapter 7.4.1, equations to as attached

Wireless Communication Systems Laboratory #2. Understanding test equipments. The students will be familiar with the following items:

PULSED NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

ISMRM weekend educational course, MR Systems Engineering, Console Electronics

Analysis of magnetic and electromagnetic field emissions produced by a MRI device

NMR spectrometer usage at the BioNMR facility ETH Zürich

Noise Measurements Using a Teledyne LeCroy Oscilloscope

Chapter 11 Coherence Editing: Pulse-field Gradients and Phase Cycling

Principios Básicos de RMN en sólidos destinado a usuarios. Gustavo Monti. Fa.M.A.F. Universidad Nacional de Córdoba Argentina

Chapter 12: Electronic Circuit Simulation and Layout Software

Applications Guide. Spectral Editing with SVS. (Works-in-Progress) MAGNETOM TaTs and Verio Systems (3T)

Exercise 2-1. Beamwidth Measurement EXERCISE OBJECTIVE

Intermediate and Advanced Labs PHY3802L/PHY4822L

System/Imaging Imperfections

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

MR Advance Techniques. Flow Phenomena. Class II

EE469B: Assignment 4 Solutions

The Discussion of this exercise covers the following points:

Experiments #6. Convolution and Linear Time Invariant Systems

Multi-channel SQUID-based Ultra-Low Field Magnetic Resonance Imaging in Unshielded Environment

Laboratory Experiment #1 Introduction to Spectral Analysis

SonoLab Echo-I User Manual

Lab E2: B-field of a Solenoid. In the case that the B-field is uniform and perpendicular to the area, (1) reduces to

New developments in near-field acoustic holography

ENSC327 Communication Systems Fall 2011 Assignment #1 Due Wednesday, Sept. 28, 4:00 pm

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0


Steady-state sequences: Spoiled and balanced methods

EECS40 RLC Lab guide

ISONIC PA AUT Spiral Scan Inspection of Tubular Parts Operating Manual and Inspection Procedure Rev 1.00 Sonotron NDT

NOVA technical note #8 1. Case study: how to use cutoff conditions in a FRA frequency scan?

STELAR s.r.l. via E. Fermi, Mede (PV) - Italy tel Uni-Pavia 24/11/06

The Pulsed Resistive Low-Field MR Scanner

Frequency Agility and Barrage Noise Jamming

RadioProcessor-G. Owner s Manual. SpinCore Technologies, Inc.

PART III LABORATORY MANUAL. Electromagnetic Waves and Transmission Lines By Dr. Jayanti Venkataraman

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

PULSED/CW NUCLEAR MAGNETIC RESONANCE

MARP. MR Accreditation Program Quality Control Beyond Just the Scans and Measurements July 2005

Supplementary Figure 1. Scanning Electron Microscopy images of the pristine electrodes. (a) negative electrode and (b) positive electrode.

Transcription:

1. Spin Echos 1.1 Find f0, TX amplitudes, and shim settings In order to acquire spin echos, we first need to find the appropriate scanner settings using the FID GUI. This was all done last week, but these calibration settings should be found before each experiment. Insert RF coil into magnet bore. Insert full water tube (phantom #1) into coil. Run FID GUI sequence, by typing FID_GUI into the command window. Make sure to set the MATLAB path, by adding the MRI_Lab folder (including subfolders) to the path. Look on your cart for a piece of paper with the recorded Larmor Frequency for your magnet; type this into the GUI for frequency. Set the # of repetitions to a high number (so it runs over and over). Reach in and slowly adjust the coil position inside the magnet. Take the sample out to make sure the signal fully goes away. Position it for maximum signal. Adjust the system console frequency f 0, until the peak is centered at 0 Hz. Record this f 0 frequency: Find the RF TX amplitude that corresponds to a 90 o flip angle and a 180 o flip angle. You can do this by stopping the run, checking the flip angle calibration box in the gui then starting again. This steps thru the amplitude of the RF excitation pulse and plots the amplitude of the FID as it goes. It steps from 0W power to ~1W. The 90 o flip angle occurs when amplitude of the FID signal is maximized. The 180 o flip angle occurs at the power of the first minimum after the first maximum. Sometimes there will be a second maximum because a 270deg rotation will be reached. Record the 90 degree TX amplitude:, Record the 180 degree Tx amplitude: In the GUI adjust current offsets to x,y,z gradient coils to apply linear shim fields. Try to increase the magnitude of the frequency peak (thus make the line as narrow as possible.) Save your best shim settings by clicking the save shims button. Record the currents: xshim: yshim: zshim: 1.2 Acquire Spin Echos Make sure the FID GUI is stopped. Run the Spin Echo GUI, but typing SE_PROJ_GUI into the command window. Enter your f0, TX amplitudes, and shim settings (use the load shims button) into the GUI. Make sure the acquisition type is set to Spin Echo. Click Run Scan

Sketch the real part of the acquired signal (green trace), note that the 180 o pulse is applied at 15ms: Stop the scan and click the zero shims button. How does the acquired signal change? Try adjusting the echo time (TE). The readout time also needs to be increased when you increase TE. Try readout = 300ms and TE= 150ms. How does the acquired signal change? Check off 1: Explain to a staff member: What is seen in the spin echo sketch (what is physically happening to the spins?) How does the acquired signal change when the shims settings are loaded versus when the shims are zeroed? How does the acquired signal change when TE is increased or decreased? (Hint: the spin echo sequence refocuses T2* spin dephasing, but there is also signal decay with a longer time constant, T2) 2. 1D Projections The goal of this lab is to learn about projection imaging. i.e. what happens when you record a signal with a linear gradient field present: ( ) where G x is defined as Then: ( )

So we see that the frequency of precession is now dependent on location, with the spins at x=0 precessing at the old frequency of gamma*b0. Let k = 1/2π γg x t and then the phase relative to the spin at x=0 becomes: ( ) ( ) ( ) ( ) Eq. 10 Since the detection coil simply adds all the signals from inside the coil: ( ) ( ) Eq. 13 where ( ) ( ) Eq. 12 Since k and t are proportional (k = 1/2π γg x t ) we stop thinking about the acquisition being as a function of t and start thinking of it as a function of k. ( ) ( ) Eq. 14 2.1 Small Cylinder Phantom Continue using SE_PROJ_GUI, but change the readout time and TE back to the default settings (TE = 30ms and readout = 60ms) To turn on gradient currents (and therefore add a gradient field), choose projection along X, Y, or Z as the acquisition type. The frequency domain signal is now a projection of the phantom onto the gradient field. We need to make sure that the phantom is centered in the gradient coils. To do this turn on the Y gradient by choosing projection along Y, this creates a field gradient along the bore of the magnet. Adjust the coil position until the projection is centered around 0 KHz in the frequency domain. Remove the full water phantom, and insert small cylinder phantom (phantom #2). How do the projections change? Fig 1: gradient field directions in magnet Go back to using the X or Z gradient. Try rotating the phantom inside the coil. Notice that width and basic shape of the projection does not change because of the geometry of the phantom (but it may shift in frequency if it s not in the center of the gradient). Plot the projection (frequency domain signal) in MATLAB. Use the fact that the cylinder is 4mm dia. to estimate the gradient field strength. Transform the x-axis to mm instead of Hz.

Check off 2: Explain/show to a staff member: How does the time domain and frequency domain signal change when a gradient field is turned on? How does the 1D projection change with the full water phantom vs the small ball phantom? Show your projection plot to staff member. What is the calculated gradient field strength? 2.2 Two-tube Phantom Insert phantom #3, which consists of 2 capillary tubes filled with water. Turn on the X gradient, rotate the phantom until the 2 projections are collapsed into a single lump. Define this as the 0 degree position. You can decrease the field of view (FOV) to 1cm to zoom in (this increases the gradient field strength). Turn on the Z gradient, the 2 projections should be maximally separated. Why? Switch back to the X gradient. Save your time domain signal in this redefined 0 deg position. Now rotate the phantom by 45 degree increments from 0 to 180 o, and save the signal from each rotation. (try not to move the coil while you are doing this) Plot the projection (frequency domain signal) of the 0 o Fig 2: Projection reconstruction plot rotation in MATLAB. Use this plot along with your gradient field strength estimate to determine the size of the 2 capillaries and the spacing between them. Plot all of the projections in MATLAB. Create a drawing like Fig. 2 with your projections (doing this by hand is fine). Check off 3: Explain/show to a staff member: Why does the X projection and Z projection look different? What angle collapses the spectral response? Show your 0 deg projection plot to staff member. What are the dimensions of this phantom in mm? Show your projection reconstruction plot to a staff member.

2.3 Mystery Phantom Remove phantom #3 and insert a mystery phantom. The mystery phantom will include some unknown number and arrangement of capillary tubes. Record mystery phantom code Make whatever measurement you think needed to figure out the geometry of the mystery phantom. At home, figure out what the mystery arrangement of tubes is. At home problem: When you upload your checkoff sheet, also include a drawing of the estimated tube arrangement and justification of how this was determined. 3. Projection Reconstruction (at home - extra credit) Design a reconstruction method using MATLAB that allows you to form a 2D image with the recorded signals from 2.2 and 2.3. Upload your code, data, and 2D image to stellar

Checkoff Name: points Staff Member Initials Prelab 2 Checkoff 1 2 Checkoff 2 2 Checkoff 3 2 At home problem 2 Scan and upload this sheet to the Stellar website prior to the due-date and time.