RMS216. 2x16 Rackmount GNSS Splitter Order online today at TECHNICAL PRODUCT DATA SHEET

Similar documents
GPS Splitter 2 in 16 Rack Mount Splitter

S18. GPS 1 x 8 Splitter TECHNICAL PRODUCT DATA. Features. Amplified to Preserve Link Margins. Passes GPS, Galileo & GLONASS L1/L2

GPS Splitter 1 in Rack Mount

S14 Splitter. Technical Product Data

S18 Splitter. Technical Product Data

A11 Amplifier. Technical Product Data

A11M Amplifier. Technical Product Data

AT11V ATTENUATOR TECHNICAL PRODUCT DATA. Features. Excellent Flat Response. Pass DC or DC Block. Passes GPS, Galileo & GLONASS L1/L2

S12 Splitter. Technical Product Data

L1L2 Low Noise Amplifier

L1 Low Noise Amplifier

MS14. Military Qualified 1x4 GPS Splitter. Description TECHNICAL PRODUCT DATA. Features. Designed & Manufactured to Military Specifications

RMALDCBS 1 X 8 Rack Mount Amplified 1X8 GPS Splitter Technical Product Data

ALDCBS 1 X 8. Technical Product Data

S14WI Splitter for Wireless Infrastructure

Prevent antenna alarm faults from connected devices

Military Amplified GPS Technical Product Data

ALDCBS 1 X 4. GPS Amplified 1X4 Splitter Technical Product Data

High Isolated Amplified GPS Technical Product Data

GNSS-3P. GNSS Passive Antenna TECHNICAL PRODUCT DATA SHEET DESCRIPTION FEATURES OPTIONS

Passive 1X2 GPS Splitter Technical Product Data

GPS Networking Inc. ALDCBS 1 X 2

PNRRKIT. Portable Networked Re-Radiating Kit Technical Product Data. Features. Description. Utilizes Existing Roof Antenna

CPDC2X1. 2X1 GPS Combiner Technical Product Data

AT11DV Digital Variable Attenuator

L1/L2GPNRRKIT. L1/L2 GNSS Portable Networked Re-Radiating Kit Technical Product Data. Features. Description. Uses Existing L1/L2 GNSS Roof Antenna

HNRRKIT. Hangar Networked Re-Radiating Kit Technical Product Data

GPS-ITS. GPS Indoor Testing Solution Technical Product Data. Features. Description. Amplified Roof Antenna Gain 35dB

L1L2-2GAD DAGR GPS Active Antenna

Features. = +25 C, +Vdc = +6V, -Vdc = -5V

L1/L2GHNRRKIT. L1/L2 GNSS Hangar Networked Re-Radiating Kit Technical Product Data. Features. Description. Amplified L1/L2 GNSS Roof Antenna Gain 33dB

X-Band Redundant LNA Systems

GPSS216 Quick Start Guide

C-Band Redundant LNA Systems

Stability as AXIOM9000 plus low noise high isolation frequency distribution amplifier with 4 to 16 outputs

Main Features: ERZ-LNA Typical applications: Performance

433 & 443 Series INTELLIGENT RELAY SP3T & SP4T IN-LINE Multithrow Switches

FMSW6097 DATA SHEET. SPDT Failsafe Electro-Mechanical Relay Switch From DC to 26.5 GHz, 20 Watts with TTL, Diodes, Indicators, SMA.

328 Innovation Blvd. 2&3 The Matchyns, London Road, Rivenhall End

FMAM4032 DATA SHEET. 10 MHz to 6 GHz, Medium Power Broadband Amplifier with 900 mw, 24 db Gain and SMA. Features: Applications:

FMAM1035 DATA SHEET. 6 db NF Low Phase Noise Amplifier Operating From 3 GHz to 8 GHz with 11 db Gain, 14 dbm P1dB and SMA. Features: Applications:

Features. = +25 C, +Vdc = +6V, -Vdc = -5V

RF Instrument Amplifier

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Thin-Film Cascadable Amplifier 5 to 1000 MHz. Technical Data. UTO/UTC 1005 Series

Features. = +25 C, Vdc = +7V

FMSW6129 DATA SHEET. SP4T Normally Open Electro-Mechanical Relay Switch From DC to 22 GHz, 20 Watts with Indicators, TTL, Diodes, SMA.

Amplifier Systems. Ultra Low Noise LNAs. Back to. C-band LNAs X-band LNAs Ku-band LNAs

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

High Power Amplifier, Solid State, Broadband MHz, 51dB Gain, SMA Female Connectors, 1dB GCP. RAMP M-51d-Sf-80W-e7

Solid State General Communication Power Amplifier

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

SDA SMA DATA SHEET

Multi-Couplers And Distribution Amplifiers 0.5 MHz to 18 GHz

SP4T RF Switch 50 Ω Absorptive RF switch 1 to 6000 MHz Internal driver, Single Supply Voltage 2.3V to 3.6V

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

4 Channel Active Antenna Combiner for Broadcast and Navigation Signals

Features. The HMC-C072 is ideal for: Microwave Radio Military & Space Test Instrumentation VSAT. = +25 C, Vdc = +7V

Pre-Filtered GPS LNA (Low Noise Amplifier)

Series CCS-19 Multi-Throw DC-2 GHz Latching Coaxial Switch

RF Subsytems & Components.

Becker Nachrichtentechnik GmbH Kapellenweg Asbach - Germany

About JFW Industries, Inc.

Microwave. Accessories for Microwave Scalar and System Analyzers

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

CUSTOM INTEGRATED ASSEMBLIES

RF Instrument Amplifier

Surface Mount RF PIN Diodes. Technical Data. HSMP-383x Series. Features. Package Lead Code Identification (Top View)

Data Sheet. ACMD-6003 UMTS Band 3 Duplexer. Features. Description. Specifications. Applications. Functional Block Diagram

FMSW6124 DATA SHEET. Transfer Latching Electro-Mechanical Relay Switch From DC to 40 GHz, 5 Watts with Indicators, TTL, Self Cut Off, Diodes, 2.

Features. Gain Variation Over Temperature db/ C

Series CCT-38S Multi-Throw DC 12 GHz, SP7T & SP8T Normally Open Coaxial Switch

FMAM5032 DATA SHEET. 48 db Gain High Power High Gain Amplifier at 50 Watt Psat Operating From 500 MHz to 3 GHz with 52 dbm IP3 and SMA.

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

Features. = +25 C, IF= 100 MHz, LO= +15 dbm* Parameter Min. Typ. Max. Min. Typ. Max. Units

SERIES YL-N DIVIDERS/COMBINER, POWER IN-PHASE 2-WAY SMA & TYPE N GHz ELECTRICAL PERFORMANCE MECHANICAL OUTLINES GENERAL SPECIFICATIONS

Data Sheet. ACMD-6103 Band 3 Duplexer. Description. Features. Specifications. Applications. Functional Block Diagram

SEMS-4079-SP8T-SMA DATA SHEET

Characterization of SPDT RF Switch (Mini-circuits MSP2TA )

Data Sheet. ACMD-6307 LTE Band 7 Duplexer. Description. Features. Specifications. Applications. Functional Block Diagram

HILNA LS Low Noise Amplifier

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Features. DC - 18 GHz. Switching Transients DC - 18 GHz 12 mvpp

Becker Nachrichtentechnik GmbH Kapellenweg Asbach - Germany

Features. Parameter Frequency Min. Typ. Max. Units. Return Loss Off State DC - 20 GHz 13 db

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Miniature Front End Radar Warning Receiver

Features. = +25 C, With 0/-5V Control, 50 Ohm System. Parameter Frequency Min. Typ. Max. Units

Data Sheet. ACPF-8040 Bandpass Filter for 3GPP Band 40. Features. Description. Functional Block Diagram. Specifications (Typ, 25 C) Applications

900 MHz Antenna Sharing Combiner ASC900VG11A

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Model 6942 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

GAUSS High Power UHF Radio

Series CCP-32N Low PIM DC 3 GHz Latching SPDT Coaxial Switch

Series CCR-58S/CR-58S Multi-Throw DC 26.5 GHz Normally Open Coaxial Switch

Features. = +25 C, Vdd= 5V. Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz

Redundant LNA Systems

SBB-3089Z Pb MHz InGaP HBT Active Bias Gain Block

Features. = +25 C, Vdc = +5V

Transcription:

TECHNICAL PRODUCT DATA SHEET RMS216 2x16 Rackmount GNSS Splitter DESCRIPTION The RMS216 amplifies and splits the GPS/GNSS signal. It includes dual input ports and 16 output ports. The dual input ports connect two GPS receive antennas. The output ports grant up to 16 GPS/GNSS receivers signal access at one time. Typically the RMS216 is configured with an 110VAC input (-48V telecom power input also available) and a regulated DC output voltage that is passed to the antenna input ports in order to power an active GPS antenna on that port. In this scenario, the RF outputs (OUT1 OUT16) would feature a 200 Ohm DC load to simulate an antenna DC current draw for any receiver connected to those ports. Redundancy is acquired through the use of a primary antenna and a backup antenna. The ability of the RMS216 to switch antennas allows all connected GPS devices to remain fully functional in the event of an antenna failure. Faults are indicated on the front panel LED and status via a DB9 interface. Within the RMS216 is an antenna health sensor and an embedded antenna switch. The sensor monitors the health of the primary antenna connected to the splitter. Based on the information provided by the sensor, the splitter will switch to the secondary antenna in the event of a failure with the primary antenna. If the failure in the primary antenna is resolved, the splitter will automatically switch back to the primary. The embedded switch has been designed so it can be controlled externally via an external rocker switch that can override the internal automatic switch mechanism. As with all splitters available from GPS Source, custom gain for output and custom connectors can be configured for the device. FEATURES - 16 GPS/GNSS Output Ports - -48VDC Power Supply Option - Embedded Antenna Health Sensor - Automatic Internal Antenna Port Switch - External Antenna Port Switching Capability - Passes GPS L1/L2, GLONASS L1/L2, Galileo, Compass - Antenna Fault Indicator Panel OPTIONS The RMS216 splitter comes with many available options to meet specific needs. Please contact GPS Source via phone, fax, email, or visit the website for further information on product options and specifications. AS9100C:2009 and ISO 9001:2008 Compliant Company

1. RMS216 Specifications 1.1 Electrical Specifications Table 1-1. Operating Temperature -40 C to 85 C Parameter Conditions Min Typ Max Units Frequency Range Ant: Any Port; Unused Ports: 50 1.2 1.7 GHz Gain Amplified (Normal) Ant: Any Port; Unused Ports: 50 7 8 9 db Amplified (Custom) (1) As Specified (xdb, 0 to 14dB) X - 2 X X + 2 db In/Out Imped. Ant, OUT1-OUT16 50 Input SWR All Ports 50 2:1 Output SWR All Ports 50 2:1 Noise Figure Ant: Any Port; Unused Ports: 50, Gain = 8dB 5 db Gain Flatness [L1 L2] Ant: Any Port; Unused Ports: 50 3 db Amp. Balance [J1 J2] Ant: Any Port: Unused Ports: 50 0.5 db Phase Balance Phase (J1 J2) Ant: Any Port; Unused Ports: 50 1 Degree Group Delay Flatness L1 - L2, Ant - Any Port, Unused Ports - 50 1 ns Isolation Amp (Hi Iso.) (Gain = 0dB) Output I P3 (Amplified) Opposite Ports: Ant 50 Adjacent Ports: Ant 50 Ant: Any Port; Unused Ports 50, Gain = 8dB, Tone Spacing = 1MHz Max RF Input Amplified Max RF Input Without Damage 0 dbm Notes: 1. Custom gain options available 2. Supports -48VDC power supply 38 24 db -7 dbm Output P 1dB (Amplified) Ant: Any Port; Unused Ports 50, Gain = 8dB -16 dbm AC IN DC IN 110 Wall Mount Transformer 110 VAC 220/240 Wall Mount Transformer (Various international plug types available) 230 VAC DC Blk Any DC Blocked Port with a 200 Load 12 VDC Powered Powered, Mil. Conn. (2) ±20 ±75 VDC Current (I internal ) Current Consumption of device (excludes Ant. Cur.) 150 ma Ant/Thru Current Powered Input Port 100 ma Page 2 of 7

1.2 Antenna Control Specifications Antenna control can be automatic with manual override. Automatic Control (Default Option) The automatic control will automatically select the primary or alternate antenna based on the fault status of the two antennas. The fault status is determined by the current draw of the antennas. A current draw below 12.5mA and above 120mA will signal a fault for the respective input port. The fault condition will cause the device to automatically switch to the other input port. The fault status is displayed on the front panel.the antenna status is indicated via the DB9. 1.2.1 Antenna Status The antenna status is available to an external application via a set of signals in the DB9 connector. The signals enable the external application to identify the antenna selected. The status is output via a SPDT relay. The relay is energized when the primary antenna is selected. The relay will be deenergized when the secondary antenna is selected or when power is off. An available factory option, reverses the energized position. The relay can switch up to 100mA at up to 60VDC or 60VAC. The normally open contact, the normally closed contact, and the common are brought out in the rear panel DB9 connector. DB9(F) Pinout 1.2.2 Antenna Control The secondary antenna is manually selected by activating an illuminted rocker switch on the front panel. Page 3 of 7

2. Product Options Table 2-1. RMS216 Available Options Power Supply Voltage Input Type 110 VAC Wall Mount Transformer Source Voltage Options 220 VAC Wall Mount Transformer 240 VAC (U.K.) Wall Mount Transformer ±20V to ±75V Military Style Connector Output Voltage DC Voltage Out 5.0 Connector Type Limitations Connector N (Female/Male) N/A SMA (Female/Male) N/A TNC (Female/Male) N/A Housing Housings Housing Type Limitations 19 x 8 x 1.75 in Rack Mount None Port Options DC Blocked OUT1 thru OUT16 are DC Blocked and 200 Loaded, DC is passed to J1 (ANT 1) & J2 (ANT2) Table 2-2. Mil Power Connector Option Pin Description A Positive B Ground Page 4 of 7

3. Product Code Decoder R M S 2 1 6 - AXX - P 110 / 5 - N F Rack Mount Splitter 216 = 2 Ant Input x 16 Output Gain Option A = Amplifi ed AS = Amplifi ed Custom Gain by Port AXX = Custom Gain (XXdB) Connector Option NF = N...Female SF = SMA...Female TF = TNC...Female Antenna Output Voltage 5 = 5.0V Source Voltage P110 P220 P240 PM = Transformer = Transformer = Transformer = Military Connector (includes PM mate - ±20V to ±75V) Note: To have product/part codes customized to meet exact needs, contact GPS Source at techsales@gpssource.com or visit the website at. Page 5 of 7

4. Mechanical Drawing RMS216 FSA-AJQ-AAX-KBZ 09/01/15 Rev 1 GPS Source Part No. RMS216 Finish Black Size D Mass 7.5lb Tolerances Linear Angular Description RACKMOUNT 2X16 SPLTR, ANT 2 In 16 Out Material N/A 3 rd Angle Projection.X = ±0.100.XX = ±0.010.XXX = ±0.005 ±1 RADII See Linear All materials and finishes shall comply with European Union RoHS and are lead free. Dimensions are in inches unless otherwise specified. Page 6 of 7