First tests of prototype SCUBA-2 array

Similar documents
Detection Beyond 100µm Photon detectors no longer work ("shallow", i.e. low excitation energy, impurities only go out to equivalent of

Superconducting Transition Edge Sensor Bolometer Arrays for Submillimeter Astronomy

Based on lectures by Bernhard Brandl

FUTURE INSTRUMENTATION FOR JCMT II

The superconducting microcalorimeters array for the X IFU instrument on board of Athena Luciano Gottardi

Quantum Sensors Programme at Cambridge

The 350 Micrometer Wavelength Superconducting Bolometer Camera for APEX

The SPICA-SAFARI TES Bolometer Readout: Developments Towards a Flight System

Acknowledgements CEA-Saclay / SAp Boulade Olivier, Doumayrou Eric, Horeau Benoit, Lepennec Yannick, Martignac Jerome, Okumura Koryo, Révéret Vincent,

Measurement of SQUID noise levels for SuperCDMS SNOLAB detectors

Optics for the 90 GHz GBT array

Penn Array Receiver Penn Array Receiver CDR Document 6: Detector Design Documents Table of Contents

Background. Chapter Introduction to bolometers

Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters

Millikelvin measurement platform for SQUIDs and cryogenic sensors

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

Transition Edge Sensors for Long Duration Balloon experiments

Novel Multiplexing Technique for Detector and Mixer Arrays

AC Bias Characterization of Low Noise Bolometers for SAFARI Using an Open-Loop Frequency Domain SQUID-based Multiplexer Operating Between 1 and 5 MHz

High Resolution 640 x um Pitch InSb Detector

Performance of a 4 Kelvin pulse-tube cooled cryostat with dc SQUID amplifiers for bolometric detector testing

A 1: 128 multiplexing rate Time Domain SQUID Multiplexer

arxiv: v1 [physics.ins-det] 9 Apr 2016

saac ewton roup ed maging etector

arxiv: v1 [astro-ph.im] 9 Apr 2016

Going towards the read-out of a 160 pixel FDM system for SAFARI 76 pixels connected

Semiconductor Detector Systems

Submillimeter Instrumentation. Photo-detectors are no longer effective Submm astronomers use bolometers and heterodyne receivers.

ULTRA LOW CAPACITANCE SCHOTTKY DIODES FOR MIXER AND MULTIPLIER APPLICATIONS TO 400 GHZ

Advances in Far-Infrared Detector Technology. Jonas Zmuidzinas Caltech/JPL

Low Vibration, Low Thermal Fluctuation System for Pulse Tube and Gifford- McMahon Cryocoolers

Charged-Coupled Devices

Detectors that cover a dynamic range of more than 1 million in several dimensions

A Millimeter and Submillimeter Kinetic Inductance Detector Camera

Development of Lumped Element Kinetic Inductance Detectors for NIKA

PROJECT DELIVERY REPORT

Dynamic Range. Can I look at bright and faint things at the same time?

Packaging of Cryogenic Components

Production of HPDs for the LHCb RICH Detectors

Light gathering Power: Magnification with eyepiece:

Advanced ACTPol Multichroic Horn-Coupled Polarimeter Array Fabrication on 150 mm Wafers

ngvla Advanced Cryocoolers For ngvla NATIONAL RADIO ASTRONOMY OBSERVATORY Larry D Addario, Caltech ngvlaworkshop, Socorro, 2017 June 26

Antenna-coupled bolometer arrays for measurement of the Cosmic Microwave Background polarization

K band Focal Plane Array: Mechanical and Cryogenic Considerations Steve White,Bob Simon, Mike Stennes February 20, 2008 COLD ELECTRONICS

BMC s heritage deformable mirror technology that uses hysteresis free electrostatic

Silicon Light Machines Patents

32-channel Multi-Chip-Module The Cryogenic Readout System for Submillimeter/Terahertz Cameras

7 Telsa SQUID Magnetometer

Micro-manipulated Cryogenic & Vacuum Probe Systems

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

Ultralight Weight Optical Systems using Nano-Layered Synthesized Materials

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1

TEST RESULTS WITH 2KX2K MCT ARRAYS

Fabrication of Feedhorn-Coupled Transition Edge Sensor Arrays for Measurement of the Cosmic Microwave Background Polarization

Detector Systems. Graeme Carrad

Muon detection in security applications and monolithic active pixel sensors

How to Build an LED Projector

Direct Detectors for FIR/submm Light: Overview of Existing & Emerging Concepts

Ian JasperAgulo 1,LeonidKuzmin 1,MichaelFominsky 1,2 and Michael Tarasov 1,2

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Instruction manual and data sheet ipca h

A Low Noise GHz Amplifier

Application Notes: Discrete Amplification Photon Detector 5x5 Array Including Pre- Amplifiers Board

VII. IR Arrays & Readout VIII.CCDs & Readout. This lecture course follows the textbook Detection of

SUPERCONDUCTING NANOTECHNOLOGY

THE ARO 0.4mm ( GHz) SIS MIXER RECEIVER. Revision 1.0

Planar Transmission Line Technologies

High-Speed/Radiation-Hard Optical Links

Multibeam Heterodyne Receiver For ALMA

Development of Local Oscillators for CASIMIR

MICROFABRICATION TECHNOLOGY FOR LARGE LEKID ARRAYS: FROM NIKA2 TO FUTURE APPLICATIONS

Characterisation of SiPM Index :

Preparing for the Future: Upgrades of the CMS Pixel Detector

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

Integrated receivers for mid-band SKA. Suzy Jackson Engineer, Australia Telescope National Facility

Sub-Millimeter RF Receiver. Sub-Millimeter 19Receiver. balanced using Polarization Vectors. Intrel Service Company

of-the-art Terahertz astronomy detectors Dr. Ir. Gert de Lange

Redefining Measurement ID101 OEM Visible Photon Counter

A SUBMILLIMETER SIS RECEIVER COOLED BY A COMPACT STIRLING-YT REFRIGERATOR

3/5/17. Detector Basics. Quantum Efficiency (QE) and Spectral Response. Quantum Efficiency (QE) and Spectral Response

Simulation of High Resistivity (CMOS) Pixels

Terahertz Spectroscopy by Josephson Oscillator and Cold-Electron Bolometer

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Mercury Cadmium Telluride Detectors

arxiv: v1 [astro-ph.im] 23 Dec 2015

DT-670 Silicon Diodes

Charge-Coupled Device (CCD) Detectors pixel silicon chip electronics cryogenics

Extra slides. 10/05/2011 SAC meeting IRAM Grenoble 1

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Submillimeter (continued)

Influence of Temperature Variations on the Stability of a Submm Wave Receiver

Superconducting Detectors and Mixers for Millimeter and Submillimeter Astrophysics

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

Implementation of frequency domain multiplexing in imaging arrays of microcalorimeters

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

PRELIMINARY. Specifications are at array temperature of -30 C and package ambient temperature of 23 C All values are typical

Low Cost Earth Sensor based on Oxygen Airglow

The first uncooled (no thermal) MWIR FPA monolithically integrated with a Si-CMOS ROIC: a 80x80 VPD PbSe FPA

arxiv: v1 [astro-ph.im] 7 Oct 2011

Transcription:

First tests of prototype SCUBA-2 array Adam Woodcraft Astronomical Instrumentation Group School of Physics and Astronomy,Cardiff University http://woodcraft.lowtemp lowtemp.org/ Techniques and Instrumentation in Low Temperature Physics meeting RAL 17th May 2005

Sub-mm astronomy Wavelengths of a few hundred µm Use mix of optical (e.g. lenses) and radio (e.g. waveguides) techniques Atmosphere largely opaque at these wavelengths Need to observe from high and dry sites (e.g. Mauna Kea in Hawai i or South Pole) Field still very immature; few applications outside astronomy for sub-mm detectors (this is changing though)

SCUBA (1) Huge revolution over the past decade Largely down to one instrument - SCUBA on the JCMT in Hawaii Development lead by ROE, Edinburgh Citation rate rivals Hubble Only instrument better known than the telecsope it s on? Cryogenically challenging: mk operation at telescope, large wire counts

SCUBA on the JCMT Oxford Instruments Kelvinox dilution fridge (Highest in the world?)

Context JCMT-UKT14 350µm-2mm.3K CSO-SHARC 350 µm array JCMT-SCUBA 350/450 & 750/850µm 91.1K Also 19 pixel 2 mm array at 0.1 K IRAM- MPIfR 1.3mm array.3k.3k LMT-BOLOCAM 1.1mm 2001-144.3K 1986-1996 1 20 91 Number of pixels.3k 37 37.3K CSO-SHARC-II 350/450 Operating temperature (300 mk much easier than 100 mk - can use sorption fridge) 1998-1996- 1997-2004- 384

Multiplex Advantage OECD Working Group on Large Future Facilities in Astronomy: The far-ir/submm is one of the few areas where massive advantages can still be made by increasing the multiplex gain (pixel count) R. Genzel Instrument Telescope Year No. of pixels UKT14 UKIRT/JCMT 1986-1996 1 SHARC CSO 1996 24 SCUBA JCMT 1997 131 MAMBO IRAM 2000 117 SHARC-II CSO 2004 384 HAWC SOFIA 2005 384 Laboca APE 2005 295 SCUBA-2 JCMT 2006 10000 SPIRE Herschel 2007 280

SCUBA-2 Large step forward >5000 pixels at 450 and 850 µm. SCUBA-2 will bring CCD-style imaging to the sub-mm for the first time Need a change in technology - SCUBA uses semiconductor bolometers, each individually assembled. Need to multiplex to keep wire count reasonable. Not practical with semiconductors for SCUBA-2 Use TES detectors:

Voltage biased TES 0.06 0.04 I SQUID Amplifier Resistance () 0.02 0 95.8 96 96.2 Vbias R(T) TES Temperature (mk) Superconducting Transition-Edge Sensor (TES)

Self-biasing As the film cools, R decreases and Joule heating increases. V I SQUID Temperature self-regulation in stable equilibrium P joule V 2 R TES Thermometer Thermal conductance P sink Heat Sink

Mo/Cu bi-layer Bilayer of thin superconducting and normal metal films acts as single superconductor with tunable T c (proximity effect) Copper 0.06 Substrate Molybdenum Molybdenum/copper: Robust. Transition is: sharp (<~5 mk) stable reproducible Resistance () 0.04 0.02 0 95.8 96 96.2 Temperature (mk)

SCUBA 850µm array Arrays Possible to fabricate array with large number of TES pixels Completed 40 32 (1280) pixel prototype SCUBA-2 array

Array Production Bump bonding MU to detector 100 µm Deep etching to isolate detector pixels

Read-out So we have an array. But: Can t read each pixel individually - too many wires! Need to be able to multiplex This is another advantage of using TES detectors SQUID based multiplexing system has been developed at NIST Uses TDM (time division multiplexing)

Price of TDM with SQUIDs: must use smart digital feedback which remembers last feedback setting to zero flux Multiplexer Feedback Flux Column Flux Bias Column Output Addr. 1 Input Coil SQUID Output Voltage L IN L FB Addr. 2 L IN L FB SQUID Bias Current L IN L FB Addr. 3 Addr. N L IN L FB Addr. N+1

Multiplexer Must use series-array SQUID (invented at NIST) to couple to room-temperature amplifiers. Required for high bandwidth and high dynamic range for switching feedback operation. Voltage Bias L NYQ R TES L IN L NYQ R TES L IN L FB L FB R LOAD L SA Conventional SQUIDs: impedance is too low. L NYQ R TES L IN L FB

2-d multiplexer Column 1 Column 2 Row 1 L IN L FB R ADD L IN L FB R ADD Row 2 L IN L FB R ADD L IN L FB R ADD R ADD R ADD Row N L IN L FB R ADD L IN L FB R ADD R ADD R ADD

In-plane multiplexer Not practical to have separate multiplexer for SCUBA-2 Not enough space Wiring the multiplexer to the detectors would be a nightmare Solution: position multiplexer below focal plane (never been done before) Use indium bump bonds to carry electrical signals and to bond the two wafers together

In-plane multiplexer Input transformer Active SQUID Summing coil gradiometer ~1mm Dummy SQUID A full-sized (40 32 pixel) multiplexer wafer

The rest... Now we just need to get the arrays cold, bring light to them and operate them So we require Test programmes Cryogenics Optics Software Electronics Telescope modifications

It s large... 4-K box

complex thermally... 1 dry dilution fridge (Leiden Cryogenics) 3 pulse tube coolers (Cryomech) 1-K box support struts 450 µm array Sapphire support structure Radiation Optical load Radiation Optical load Radiation shield mk straps Hairbrush 1-K straps De m ountable joint Still 850 µm array Mixing cham ber mk strap supports Dem ountable joints Connector plate Series arrays 4-K heat sink Hairbrush support Epoxy joint Shutter driveshaft Shutter motor 1-K box Array wiring 4-K box Thermal link Array wiring Motor support Shutter

with a novel dilution fridge... Leiden Cryogenics has developed a dry dilution fridge cooled with a pulse tube cooler rather than a helium bath Specification: 500 µw at 120 mk Large reduction in operating costs at telescope Many other applications: turnkey cooling down to mk temperatures

and many solutions to find Example: making good thermal contact to silicon wafer without thermal contraction breaking it. Solution: hairbrush :

and many solutions to find Need to support arrays rigidly with low heat leak Solution: sapphire interface support : 2.5 µw heat leak from 1 K to 100 mk Cold side Thermal isolation Warm side

But it s all worth it. SCUBA Galactic Centre Survey Galactic Plane ~120 hrs over 2 years of excellent weather telescope time Full moon SCUBA-2 could map the ENTIRE AREA shown above in just a couple of hours to the same S/N...

And Many other applications possible for the technology developed: Future sub-mm astronomy instruments THz imaging (medical, security ) Turnkey mk cryogenic operation Construction of other large mk instruments (considerable research into design aspects such as thermal straps)

Prototype tests Electrical and optical tests of prototype array carried out late 2004/early 2005 at Cardiff First test of multiplexer integrated with detectors Testbed mimics electrical, mechanical and thermal interfaces of instrument Detector array unit can be mounted in testbed without modification.

Cooled using Leiden Cryogenics custom built (wet) dilution refrigerator Testbed layout

Sub-Array Module 60 mk 1 K ~45mm Detector array Ribbon cables: Niobium film on kapton Series array unit in niobium cans (need to be at 1-K 1 because of heat dissipation)

Installation Folded and ready for installation Dilution insert Installed in Cardiff test facility

Keeping it clean

Ready to go

Test results Scatter in T c < 10 mk Transition width ~ 2 mk Detector resistance (in arbitrary units) as a function of heat sink temperature

Test results In transition Normal state Superconducting Detector current as a function of bias ( load curve )

Test results Electrical power ~ constant Superconducting In transition Normal state Detector power as a function of bias

Test results Eight pixels responding to modulated sub-mm illumination

Noise Noise measured on several pixels Noise spectrum measured while modulating signal from sub-mm illuminator at 2 Hz. NEP ~ 2.5 x 10-17 Well within specifications Compare SCUBA: NEP ~ 1 x 10-16 (at 15 Hz, compared to ~ khz for SCUBA-2)

Conclusions Detectors and multiplexer work Behaviour is stable and repeatable Presence of detectors doesn t prevent multiplexer operation Pixels detect sub-mm radiation well Pixel uniformity is good (sufficient for operation) Noise properties are good and within specifications Successful tests on prototype have enabled us to start manufacture of science grade arrays Many other applications for the technology developed, inside and outside astronomy

THE END