MCR Scanning Electron Microscopy Laboratory Portfolio

Similar documents
Scanning Electron Microscopy Laboratory Portfolio

Scanning Electron Microscopy Laboratory Portfolio

Scanning Electron Microscopy Laboratory Portfolio

Scanning Electron Microscopy Student Image Portfolio

Scanning Electron Microscopy Project Portfolio

JSM 6060 LV SCANNING ELECTRON MICROSCOPE STANDARD OPERATING PROCEDURES

Scanning electron microscope

Scanning electron microscope

Choosing the Right Accelerating Voltage for SEM (An Introduction for Beginners)

Introduction of New Products

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Low Voltage Electron Microscope

S200 Course LECTURE 1 TEM

Secondary Electron Detector

2017 MICROSCOPE REVIEW by Karen L. Lancour RELATIVE SIZE OF MICROBES

Fabrication of Probes for High Resolution Optical Microscopy

MODULE I SCANNING ELECTRON MICROSCOPE (SEM)

2018 MICROSCOPE REVIEW by Karen L. Lancour RELATIVE SIZE OF MICROBES

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

The microscope is useful in making observations and collecting data in scientific experiments. Microscopy involves three basic concepts:

Low Voltage Electron Microscope

Marine Invertebrate Zoology Microscope Introduction

LVEM 25. Low Voltage Electron Mictoscope. fast compact powerful

ELECTRON MICROSCOPY AN OVERVIEW

Introduction to Scanning Electron Microscopy

The light microscope

Module 4B7: VLSI Design, Technology, and CAD. Scanning Electron Microscopical Examination of CMOS Integrated Circuit

Dickinson College Department of Geology

Using the Hitachi 3400-N VP-SEM

Burton's Microbiology for the Health Sciences

(Refer Slide Time: 00:10)

General information. If you see the instrument turned off, notify MIC personnel. MIC personnel will help you insert your samples into the instrument.

Chapter 1. Basic Electron Optics (Lecture 2)

JEOL 6500 User Manual

Title: Thinking with the Eyes Author(s): Elizabeth Haggerty Hutton Date Created: 8/5/2011 Subject: Biology Grade Level: 9 th Grade Honors Standards:

Functions of the SEM subsystems

SECONDARY ELECTRON DETECTION

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

Low Voltage Electron Microscope. Nanoscale from your benchtop LVEM5. Delong America

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

1.When an object is sharply focused and the slide is moved towards you, in which direction does the

Standard Operating Procedure

JEOL 6700 User Manual 05/18/2009

MSE 595T Transmission Electron Microscopy. Laboratory III TEM Imaging - I

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

Chapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation

Yuta Sato, Kazu Suenaga, Shingo Okubo, Toshiya Okazaki, and Sumio Iijima

SEM Training Notebook

STRUCTURE OF THE MICROSCOPE

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Introduction to Electron Microscopy

JEOL JEM-1400 Transmission Electron Microscope Operating Instructions

SCANNING ELECTRON MICROSCOPY By W. C. NIXON (Engineering Laboratory, Cambridge University)

Magnesium and Magnesium-Silicide coated Silicon Nanowire composite Anodes for. Lithium-ion Batteries

MICROSCOPY MICROSCOPE TERMINOLOGY

Operating Checklist for using the Scanning Electron. Microscope, JEOL JSM 6400.

Development of JEM-2800 High Throughput Electron Microscope

Operation Guide. Hitachi S-3400N. Variable Pressure Scanning Electron Microscope. with. Deben Peltier Coolstage

I. The First Microscopes. Microscope Basics. II. The Bright Field Microscope. Confocal Laser Scanning Microscopy. A. The Compound Microscope

Lecture 20: Optical Tools for MEMS Imaging

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

Scale. A Microscope s job in life. The Light Microscope. The Compound Microscope 9/24/12. Compound Microscope Anatomy

Basics of Light Microscopy and Metallography

Chapter 2 Alignment C. Robert Bagnell, Jr., Ph.D., 2012

Scanning Electron Microscopy SEM. Warren Straszheim, PhD MARL, 23 Town Engineering

Microscope Notes. units of life.

Microscopy Techniques that make it easy to see things this small.

CALIBRATION OF MICROSCOPE EYEPIECE GRATICULE

Scanning Electron Microscopy. EMSE-515 F. Ernst

Operating Checklist for using the Scanning Electron Microscope, JEOL JSM 6400.

Education in Microscopy and Digital Imaging

TB80: Scanning Electron Microscopy of Insects: Techniques for the Novice

Topics 3b,c Electron Microscopy

3 Analytical report of glass beads from Hoa Diem site, Khanh Hoa, Viet Nam.

Microscopy: Fundamental Principles and Practical Approaches

Katarina Logg, Kristofer Bodvard, Mikael Käll. Dept. of Applied Physics. 12 September Optical Microscopy. Supervisor s signature:...

Supporting Information

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

SOP for Hitachi S-2150 Scanning Electron Microscope For review purposes only

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS

Observing Microorganisms through a Microscope

Scanning Electron Microscope in Our Facility

Low-energy Electron Diffractive Imaging for Three dimensional Light-element Materials

The Care and Use of the Microscope. Lab Exercise #4

NeoScope. Simple Operation to 40,000. Table Top SEM. Serving Advanced Technology

Light Microscopy. Upon completion of this lecture, the student should be able to:

Atomic-Level Control of the Thermoelectric Properties in Polytypoid Nanowires

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

Observation of the Inner Structures of Sea-Urchin Eggs by Projection X-Ray Microscopy

Ex 1: Introduction to the microscope


Microscopy. ( greek mikros = small; skopein = to observe)

Using Microscopes. Life Science: Molecular

How to choose a Scanning Electron Microscope (SEM)

Microscope. Dr. Leena Barhate Department of Microbiology M.J.College, Jalgaon

Tissue Preparation ORGANISM IMAGE TISSUE PREPARATION. 1) Fixation: halts cell metabolism, preserves cell/tissue structure

SEM OPERATION IN LOW VACUUM MODE

Microscopic Structures

Microbiology: Observing Bacteria Laboratory -1. Name Date

ELECTRON MICROSCOPY. 13:10 16:00, Oct. 6, 2008 Institute of Physics, Academia Sinica. Tung Hsu

Transcription:

SUNY College of Environmental Science and Forestry Digital Commons @ ESF N.C. Brown Center for Ultrastructure Studies Fall 2016 MCR 484 - Scanning Electron Microscopy Laboratory Portfolio Timothy Gervascio SUNY - College of Environmental Science and Forestry Follow this and additional works at: http://digitalcommons.esf.edu/ultrastructure Part of the Nanoscience and Nanotechnology Commons, Structural Biology Commons, and the Structural Materials Commons Recommended Citation Gervascio, Timothy, "MCR 484 - Scanning Electron Microscopy Laboratory Portfolio" (2016). N.C. Brown Center for Ultrastructure Studies. 13. http://digitalcommons.esf.edu/ultrastructure/13 This Presentation is brought to you for free and open access by Digital Commons @ ESF. It has been accepted for inclusion in N.C. Brown Center for Ultrastructure Studies by an authorized administrator of Digital Commons @ ESF. For more information, please contact digitalcommons@esf.edu.

Scanning Electron Microscopy Laboratory Portfolio Timothy Gervascio Fall 2016 Submitted for MCR 484/783 Scanning Electron Microscopy Fall 2016 N.C. Brown Center for Ultrastructure Studies

These images were prepared as part of the class MCR 484 Scanning Electron Microscopy at SUNY College of Environmental Science and Forestry, Fall 2016, All images were acquired on the JEOL JSM 5800 LV Scanning Electron Microscope in the N. C. Brown Center for Ultrastructure Studies 2

Tim Gervascio Major: Conservation Biology Career Goals: Biological research. The images found in this collection are examples of the knowledge and skills I have developed through the MCR 484 Scanning Electron Microscopy course taken in the fall 0f 2016. I took this course because I have always had an interest in microscopes, and this was a good opportunity to learn about and use a new type of microscope. 3

Table of Contents I images I am presenting in this collection were chosen because they exemplify the knowledge and skills I have developed along with the care, quality, and concern for the work I produce. Description 1.My Best Work 2.The Hardest 3.My Favorite 4.Images from lab exercises 4

Figure 1: My Best Image I chose this as my best image because it shows fine surface detail and macro-scale structures at the same time. I was also able to capture a large depth of field while working within the limitations of an uncoated biological sample and a low accelerating voltage. 5

Figure 1. My Best Image: An uncoated arthropod antennae imaged at 1kV produced a clear image with enough signal and very little edge effect even on the thin hair-like projections. Spot size 12, Working Distance 9mm, Objective aperture 2. 6

Figure 2: The Hardest Image to Capture This was the hardest image to capture because of the 100,000x magnification. Getting the best image required careful adjustment of the spot size and plane of focus. 7

Figure 2. Hardest Image to Capture: Scanning electron micrograph of structural detail on a sputter coated gastropod shell. 25kV accelerating voltage, 9mm working distance, objective aperture 1, spot size 10. 8

Figure 3: My Favorite Image This is my favorite image because of its artistic value, and the surprisingly high quality of the image given the sample preparation. All of the foreground is in clear focus and the charging is surprisingly limited at 15kV considering the sample is uncoated and biological. Artistically, I like the piece of lichen in the background hanging out off the edge in contrast to the dark background. 9

Figure 3. Favorite Image: Secondary electron image of uncoated lichen. 15kV accelerating voltage, 19mm working distance, spot size 6, 1600x magnification. 10

Additional Examples of My Work The following images are additional examples of my work I have included because it is another one of my favorite images. It shows a lot of topographical information and has artistic value. 11

Figure 4. Scanning electron micrograph of the top surface of a leaf. Sample was critical point dried and sputter coated. Critical point drying preserves the cellular structure and the distinctiveness of each cell. Spot Size 10, Working Distance 19mm, 15kV accelerating voltage, micron bar is 10 micrometers. 12

Images from Labs 1-10 A portfolio of micrographs from lab sessions demonstrating the following techniques: 1.Secondary Electron Image and Probe diameter (spot size) a. Spot size 8 b. Spot size 20 c. Spot size 11 2.Specimen Preparation - Sputter Coating 3.Specimen Preparation - Critical Point Drying 4.Image Quality II -Depth of Field a. short WD, large aperture b. long WD, small aperture 5.Image Quality I -Accelerating Voltage a. 20 kv b. low kv 6.Backscattered Electron Imaging a. SEI image b. BEI image 7.Low voltage (< 2kV) of uncoated biological sample 8.High Magnification 9.Digital Imaging with Photoshop 10.Stereo Pair 13

Figure 1a. Secondary electron image of debris on sputter coated gastropod shell. Spot Size 8 (small), 19mm working distance, 15kV accelerating voltage, 1900x magnification. 14

Figure 1b. Secondary electron image of debris on sputter coated gastropod shell. Spot Size 20 (large), 19mm working distance, 15kV accelerating voltage, 1900x magnification. 15

Figure 1c. Secondary electron image of debris on sputter coated mollusk shell. Spot Size 11 (medium), 19mm working distance, 15kV accelerating voltage, 1900x magnification.

Figure 2. SEM micrograph of sputter coated lichen. Spot Size 8, Working Distance 19mm, 15kV accelerating voltage, 6000x magnification. 17

Figure 3. Scanning electron micrograph of the top surface of a leaf. Sample was critical point dried and sputter coated. Critical point drying preserves the cellular structure and the distinctiveness of each cell. Spot Size 10, Working Distance 19mm, 15kV accelerating voltage, micron bar is 10 micrometers. 18

Figure 4a. SEM micrograph of an angled TEM grid to demonstrate depth of field. A larger objective aperture and a short working distance yields the worst depth of field. The center of the image is in focus, but the edges are far out of focus. Working distance 12mm, Objective Aperture 2, Spot Size 16, 10kV accelerating voltage. 19

Figure 4b. SEM micrograph of an angled TEM grid to demonstrate depth of field. Objective aperture was set to the smallest size and working distance was set to a longer distance. This setup gives the best depth of field, both the center of the image and the edges are in focus, but some signal is sacrificed. Working distance 28mm, Objective Aperture 1, Spot Size 16, 10kV accelerating voltage. 20

A B Figure 5. Scanning electron micrographs of conductive watch movement components to illustrate the effects of accelerating voltage on image quality. A) Accelerating voltage of 25kV allowed for the magnification to be increased greatly and demonstrates the resolving power of electron microscopy. Spot size 10, 21mm working distance, objective aperture 1. B) Lower accelerating voltage of 10kV shows the surface detail of a scar on the metal surface without the image being too hot and reducing edge effects. 21mm working distance, objective aperture 1, spot size 10. A long working distance and small aperture give good depth of field in both images. 21

A B Figure 6. Three TEM grids, one gold and two copper, overlapped to show atomic number contrast in a backscatter electron image (BEI). A) Secondary electron image of the three grids showing the immediate surface details of the sample. B) Backscatter electron image of the same TEM grids showing atomic number contrast and revealing information from deeper in the sample's surface. 20kV accelerating voltage, Objective aperture 2, spot size 16, working distance 14mm. 22

A B Figure 7. Scanning electron micrographs of uncoated biological samples to illustrate the impact of accelerating voltage on image quality. A) An accelerating voltage of 0.7kV was enough to cause some mild charging effects on this tiger whisker, and some graininess was apparent due to the reduced signal relative to the noise in the chamber. Spot size 12, Working Distance 11mm, Objective Aperture 2. B) An uncoated arthropod antennae imaged at 1kV produced a clear image with enough signal and very little edge effect even on the thin hair-like projections. Spot size 12, Working Distance 9mm, Objective aperture 2. 23

Figure 8. Scanning electron micrograph of structural detail on a sputter coated gastropod shell. 25kV accelerating voltage, 9mm working distance, objective aperture 1, spot size 10. 24

A B Figure 9. Scanning electron micrographs of structural detail on a sputter coated gastropod shell a) before image processing and b)after image processing. The brightness and contrast was edited to make full use of the range of greyscale values according to the histogram. Additionally, the Unsharp Mask filter was applied to image b. Scale bar = 100nm. 25kV accelerating voltage, 9mm working distance, objective aperture 1, spot size 10. 25

Figure 10. Red/green stereo from a scanning electron micrograph of an uncoated geode. Images were processed in photoshop and merged to produce the stereo pair. Both micrographs produced at 15kV accelerating voltage, objective aperture 1, spot size 11, working distance 36mm, 1300x magnification, scale bar represents 10 microns. 26