SECTION MECHANICAL IDENTIFICATION

Similar documents
SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

Industrial Pipe Marking

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION MECHANICAL IDENTIFICATION

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

Piping & Equipment Identification

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

1. ASME A Scheme for the Identification of Piping Systems.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

SECTION COMMON WORK RESULTS FOR HVAC

A. Product Data: For each electrical identification product indicated.

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

SECTION IDENTIFICATION DEVICES

SECTION ELECTRICAL IDENTIFICATION

1. State that all workmanship must conform to all pertinent laws, ordinances and regulations of all bodies having jurisdiction.

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

SECTION ELECTRICAL IDENTIFICATION

IDENTIFICATION DEPOT, INC. 206 East Second Street Washington, NC PHONE FAX

Page PRODUCT DESCRIPTION

Basic Principles and Operation of Transformer

A/E REVIEW CHECKLIST HVAC

Facility Services Subgroup Preface for Divisions 21` through 28

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

U of I Facilities Standards Updates for 2017

Electrical IP Red Seal Practice Exam

Page PRODUCT DESCRIPTION

QUALITY ASSURANCE SPECIFICATION

TELEPHONE: (215) Addendum No Cooling Plant Replacement SDP Contracts No. B-080C, B-081C and B-082 of 2017/18

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Technical Development Program

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Page PRODUCT DESCRIPTION

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

MRI Safety. Stickers. MRI Safe - Do Not Remove From MRI Area - Warning Stickers. Available in Red or Green

SUPPLEMENTARY INSTALLATION INSTRUCTIONS Ventilating Fan (Contractor Pack)

INSTALLATION MANUAL STORAGE

Design Deliverables. Summary. A. Expectations for Design Deliverables:

ADDENDUM NO. 4 November 15, Page 1

Facility Pipe Marking

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

APPLICATION FOR COMMERCIAL CONSTRUCTION FIRE AND LIFE SAFETY PLAN REVIEW PROJECT INFORMATION: Project phone: Project Address: City: State: Zip:

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

MECHANICAL GENERAL REQUIREMENTS SECTION B. The requirements of this SECTION apply to all work of this DIVISION.

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

SECTION SIGNAGE

B32157 UNDERCARRIAGE KIT. Jeep Cherokee Jeep Wagoneer Jeep Comanche Parts List and Installation Instructions CAUTION

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Rabbit Series Laser Engraving Machine HX3040. User s Manual. 1 Jinan King Rabbit Technology Development Co. Ltd.

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

A. Section includes surface preparation and the application of paint systems on exterior substrates.

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio

SECTION LOW PRESSURE DUCTWORK

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Comparison that shows the differences between a PFD and P&ID :

SECTION EQUIPMENT WIRING

EASQ ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) MARKING SCHEDULE. SECTION 1 Marks Reference Marking notes Qu 1 A 10 MΩ (2 marks)

Risk Management Department. Control of Hazardous Energy

IMPORTANT! READ BEFORE PROCEEDING! SV Weather Caps

City of Thousand Oaks

SECTION INTERIOR SIGNAGE

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

Electrical Identification

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

BUILDING PLAN REVIEW REQUIREMENTS

Heat Exchanger Construction Checklist

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel and iron.

FLUX CORE 90 WELDER ASSEMBLY & OPERATING INSTRUCTIONS

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Tools required by installer: Materials required by installer:

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Addendum No. 1 page 1

NORTHWEST FLORIDA STATE COLLEGE MONUMENT SIGNS WITH LED DISPLAYS

SECTION LABORATORY CASEWORK AND EQUIPMENT

HAND AND POWER TOOLS

Transcription:

SECTION 15190 MECHANICAL IDENTIFICATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Identification of mechanical products installed under Division 15. B. Related Sections: 1.02 REFERENCES 1. Section 09900 - Painting. A. American National Standards Institute (ANSI). 1. ANSI A13.1 "Scheme for the Identification of Piping Systems". 2. ANSI Z53.1 "Safety Color Code for Marking Physical Hazards". B. American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE). 1.03 DESIGN REQUIREMENTS A. Assignment of unit identification numbers to operating units of equipment within a class or subclass will be made during the design phase of new buildings, additions, or remodeling of existing structures. 1. A class, subclass list will be provided to the designer by the Facilities Management Preventive Maintenance coordinator, indicating codes to use for the assignment of unit identification numbers. B. In new structures, the numbering system will start in the basement with O1, within a class or subclass, and continue on in ascending order up to and including the equipment that may, be located on a roof. C. When new operating equipment is to be added to an existing structure, the numbering of any new units of equipment will be fit in with the existing numbering scheme. The designer should contact the UCB Preventive Maintenance Office for information and/or instructions and details. AUGUST 2011 UCB STANDARDS 15190-1

D. Specify that all equipment, including motors, shall be stenciled with the proper class-subclass code and correct unit identification as indicated in the contract documents, using a contrasting color. E. Specify labels to identify location of valves, terminal units and Fire and F/S dampers above ceilings, as noted below in this section. F. Drawings shall indicate unique numbers for all terminal units (e.g. VAV boxes). Specify that Contractor shall label the units accordingly, including the space being served. G. Install engraved plates on split systems; indicating the other unit(s) a device serves, for example condensing-unit and fan-coil unit, chiller and cooling tower, etc 1.04 DEFINITIONS (Excerpts from ANSI A13.1-1981) A. Materials Inherently Hazardous: 1. Flammable or Explosive: a. Materials which are easily ignited, including materials known as fire producers or those creating an explosive atmosphere. 2. Chemically Active or Toxic: a. Materials which are corrosive, or are in themselves toxic or productive of poisonous gases. 3. At Temperatures or Pressures: a. Materials which, when released from the piping, would have a potential for inflicting injury, or property damage by burns, impingement, or flashing to vapor state. 4. Radioactive: a. Materials which emit ionizing radiation. B. Materials of Inherently Low Hazard: 1. All materials which are not hazardous by nature, and are near enough to ambient pressure and temperature that people working on systems carrying these materials run little risk through their release. C. Fire Quenching Materials: 1. This classification includes sprinkler systems, and other piped fire fighting or fire protection equipment. This includes water, chemical foam, CO 2, Halon, etc. PART 2 - PRODUCTS AUGUST 2011 UCB STANDARDS 15190-2

2.01 IDENTIFICATION MATERIALS FOR PIPING AND EQUIPMENT A. Metal Tags: 1. Round brass discs, minimum 1-1/2" diameter with edges ground smooth. 2. Each tag punched and provided with brass chain for installation. B. Engraved Nameplates: 1. Laminated three-layer plastic with engraved black letters on light contrasting background color. C. Paint Stencils: 1. Of size and color per ANSI/ASME A13.1 using clean cut letters and oil base semi-gloss enamel paint. 2. Paint material shall comply with Section 09900-Painting. 3. Size of Legend and Letters for Stencils: Insulation or Length of Size of Pipe Diameter Color Field Letters 3/4" to 1-1/4" 8" 1/2" 1-1/2" to 2" 8" 3/4" 2-1/2" to 6" 12" 1-1/4" 8" to 10" 24" 2-1/2" over 10" 32" 3-1/2" Ductwork and Equipment N/A 2-1/2" D. Pressure Sensitive Markers: Brady Type 350 flexible vinyl film identification markers and tape, with legend, size and color coding per ANSI A13.1. E. Semi-rigid Plastic Identification Pipe Markers: Seton Setmark with legend, size and color coding per ANSI A13.1 Direction of flow arrows are to be included on each marker, unless otherwise specified. 1. Setmark Type SNA markers to be used on diameters 3/4" thru 5". 2. Setmark Type STR markers to be used on diameters 6" or larger. PART 3 - EXECUTION AUGUST 2011 UCB STANDARDS 15190-3

3.01 IDENTIFICATION OF PIPING AND EQUIPMENT A. General: 1. Provide pipe identification, stencils, or engraved name plates to clearly identify the mechanical equipment, piping and controls of the various mechanical systems and direction of flow in piping. Valve tags are not required. See requirement for floorplans with valve locations, elsewhere. B. Methods for identification as follows: 1. Metal Tags: a. Stamp tags with letter prefixes to indicate service, followed by a number for location in system. 2. Engraved Nameplates: a. Attach nameplates with brass screws. b. Pressure-sensitive embossed labels are not acceptable. c. Nameplates shall bear the same identifying legend used on the Contract Documents. 3. Painted Stencils: a. Pipes and equipment to be stenciled shall first be wiped clean of dirt, dust, rust, grease and moisture b. Prepare surfaces in accordance with Section 09900-Painting for stencils. c. Pipes and equipment shall be painted with required color code to a smooth hard surface in the area the stencil is to be applied. d. Stenciled markings shall be neatly performed with no overspray, drips, or other imperfections. e. Legend Letters and Color Field size as specified for Paint Stencils in Part 2 of this Section. f. Paint application shall comply with Section 09900-Painting. 4. Pressure Sensitive Markers: Apply pressure sensitive markers in accordance with manufacturer's recommendations with complete wrap around. Marker adhesion will be tested for permanence. Any markers showing dog ears, bubbles, or other failings shall be replaced. 5. Semi-Rigid Plastic Identification Markers: Seton Setmark pre-molded (not pressure sensitive) identification markers may be used at Contractor's option on service piping which is accessible for maintenance operations (but not on piping in finished spaces). This type marker shall not be installed on bare pipe when surface temperature exceeds 180 deg. F unless a 1" thick insulation band is first provided under marker for protection from the hot pipe. C. Classification of Hazards of Materials, Designation of Colors and Legend: AUGUST 2011 UCB STANDARDS 15190-4

D. Piping: 1. Provide per ANSI Standard 13.1 and ANSI Z53.1 1. Identify all piping accessible for maintenance in crawl spaces, tunnels, above ceilings, and access spaces as well as exposed to view utilizing stenciled markings according to the following procedures: E. Controls: a. Use an arrow marker for each pipe-content legend. The arrow shall always point away from the pipe legend and in the direction of flow: color and height of arrow to be same as content legend lettering. b. If flow can be in both directions, use a double-headed arrow indication. c. Apply pipe legend and arrow indication at every point of pipe entry or exit where line goes through wall or ceiling cut. d. Apply pipe legend and arrow indication within 3" of each valve to show proper identification of pipe contents and direction of flow. e. The legend shall be applied to the pipe so that lettering is in the most legible position. For overhead piping, apply legend on the lower half of the pipe where view is unobstructed, so that legend can be read at a glance from floor level. f. For pipes under 3/4" O.D., fasten brass tags securely at specified legend locations. g. Legend on steam piping, condensate return, compressed air, gas, and vacuum systems shall include working pressure or vacuum. h. Markers shall be spaced every 20 feet and at least once in every room. 1. Magnetic starters and relays, shall have nameplates or be stenciled to identify connecting or controlled equipment. 2. Manual operating switches, fused disconnect switches and thermal overload switches which have not been specified as furnished with indexed faceplates shall also have nameplates or be stenciled as to "connected" or "controlled" equipment. 3. Automatic controls, control panels, zone valves, pressure electric, electric pressure switches, relays, and starters shall be clearly identified. 4. Identify locations of control transformers in the as-built control drawings, and install labels on the ceiling grid with the designation CTRL XFMR. Add tag at transformer indicating the devices it serves. F. Pumps: AUGUST 2011 UCB STANDARDS 15190-5

1. Pumps shall be identified as to service and zones served. 2. Base mounted pumps shall be stenciled or have system served nameplates. 3. Brass tags secured by tie wires may be used on small in-line pumps. G. Storage Tanks, Water Treatment Equipment and Heaters: H. Fans: 1. Tanks and heaters shall be stenciled as to service. 2. The connecting pipes to each shall be identified and the service temperature entering and leaving the tank or heater shall be indicated. 1. Supply and exhaust fans and air handling units and connecting ductwork supplying one or more areas from an equipment room or isolated crawl or furred space shall have nameplate or be stenciled as to plan code number, service and areas of zones served. I. Air Conditioning Equipment: 1. Equipment such as chillers, pumps, condensers, or roof-top equipment shall be identified by stencils, or system nameplates. Labels of remote equipment shall also indicate the space(s) being served and the location of their electrical breaker (Panel ID, Room No. and Circuit). 2. Refrigeration equipment shall be labeled with the type and approximate quantity of refrigerant. J. Lift-Out Ceilings & Access Doors: 1. Provide Kroy type adhesive labels on ceiling tee or access door to identify concealed valves, air terminal units, fire/smoke and fire dampers, or similar concealed mechanical equipment which is directly above nameplate in ceiling space. a. Use the following colors for specified labels: i. Fire-protection devices, including dampers: a) 3/8" red letters on white background. ii. iii. iv. Air-handling terminal devices: a) 3/8" black letters on white background. Isolation, balancing and control valves: a) 3/8" black letters on white background Isolation valves for plumbing: AUGUST 2011 UCB STANDARDS 15190-6

a) 3/8 blue letters on white background. 2. Label shall be installed oriented to read towards the ceiling tile that needs to be removed for access. K. Terminal Units 1. Identify all units with unique numbers corresponding to the drawings. L. Shut-off Valve Schematics 1. Provide one schematic per floor indicating the location of shut-off valves for plumbing-water supplies and hot-water recirculation piping, and for hydronic systems. 2. The schematics shall be computer generated on vinyl with adhesive backing and applied to 0.08-inch thick aluminum sheets. 3. They shall be installed on the wall or a stand near the water-entry station for plumbing-water supply and near the pumping stations for hydronics. END OF SECTION 15190 AUGUST 2011 UCB STANDARDS 15190-7