PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

Similar documents
SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION MECHANICAL IDENTIFICATION

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

Industrial Pipe Marking

Piping & Equipment Identification

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

SECTION MECHANICAL IDENTIFICATION

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION MECHANICAL IDENTIFICATION

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

SECTION MECHANICAL IDENTIFICATION

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

1. ASME A Scheme for the Identification of Piping Systems.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

SECTION IDENTIFICATION DEVICES

SECTION COMMON WORK RESULTS FOR HVAC

U of I Facilities Standards Updates for 2017

Page PRODUCT DESCRIPTION

A. Product Data: For each electrical identification product indicated.

IDENTIFICATION DEPOT, INC. 206 East Second Street Washington, NC PHONE FAX

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

A/E REVIEW CHECKLIST HVAC

Facility Pipe Marking

SECTION ELECTRICAL IDENTIFICATION

TELEPHONE: (215) Addendum No Cooling Plant Replacement SDP Contracts No. B-080C, B-081C and B-082 of 2017/18

Page PRODUCT DESCRIPTION

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Page PRODUCT DESCRIPTION

Basic Principles and Operation of Transformer

A/E REVIEW CHECKLIST PLUMBING/FIRE PROTECTION/SANITARY

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

Facility Services Subgroup Preface for Divisions 21` through 28

BUILDING PLAN REVIEW REQUIREMENTS

1. State that all workmanship must conform to all pertinent laws, ordinances and regulations of all bodies having jurisdiction.

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

SECTION ELECTRICAL IDENTIFICATION

SUPPLEMENTARY INSTALLATION INSTRUCTIONS Ventilating Fan (Contractor Pack)

Trade of Plumbing. Module 1: Thermal Process and Mild Steel Pipework Unit 5: Drawing Phase 2

Design Deliverables. Summary. A. Expectations for Design Deliverables:

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

NORTHWEST FLORIDA STATE COLLEGE MONUMENT SIGNS WITH LED DISPLAYS

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

APPLICATION FOR COMMERCIAL CONSTRUCTION FIRE AND LIFE SAFETY PLAN REVIEW PROJECT INFORMATION: Project phone: Project Address: City: State: Zip:

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

Electrical IP Red Seal Practice Exam

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

British Standard Pipe Markers (BS1710-BS4800)

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

Heat Exchanger Construction Checklist

MRI Safety. Stickers. MRI Safe - Do Not Remove From MRI Area - Warning Stickers. Available in Red or Green

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

Residential Construction Checklist Single and Two Family Construction

Tools required by installer: Materials required by installer:

Rabbit Series Laser Engraving Machine HX3040. User s Manual. 1 Jinan King Rabbit Technology Development Co. Ltd.

UTSA Facilities Condition Assessment. Out Brief August XX, 2009

Risk Management Department. Control of Hazardous Energy

Paul Cuffe Math-Science Technology Academy ES 8324 S Racine Ave Chicago, IL 60620

Installation Guidelines

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio

SF 6 Characteristics and Re-use Concept

ADDENDUM NO. TWO. To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS

ADDENDUM #2 September 12, 2018

B32157 UNDERCARRIAGE KIT. Jeep Cherokee Jeep Wagoneer Jeep Comanche Parts List and Installation Instructions CAUTION

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

ADDENDUM NO. 4 November 15, Page 1

STEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607

Bid No. B14-02 Building 100 HVAC Improvements

Charles N Holden Elementary School

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

Contemporary Collection

EPIC Academy High School

Andrew Carnegie Elementary School

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

City of Thousand Oaks

ADDENDUM NO. 2 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

TO WHOM IT MAY CONCERN:

INSTALLATION MANUAL STORAGE

Philip Rogers Elementary School

SECTION INTERIOR SIGNAGE

NEW SEVICE CENTER BOB HART CHEVROLET. 495 S. 7th St. E:\RE Smith New Logo.jpg VINITA, OK RE SMITH BOB HART CHEVROLET NEW SERVICE CENTER

Amos Alonzo Stagg Elementary School

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

Comparison that shows the differences between a PFD and P&ID :

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Technical Development Program

Transcription:

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Assign unit identification numbers to operating units of equipment within a class or subclass during the design phase of new buildings, additions, or remodeling of existing structures. 1. In new structures, start the numbering system with 001, within a class or subclass 2. Numbers shall include building identification, system, type, sub-type and number compliant with the DPS Facility Information System and DPS project numbering system. 3. When new operating equipment is to be added to an existing structure, the numbering of new units of equipment shall fit in with the existing numbering scheme. 4. Drawings shall indicate unique numbers for all terminal units (e.g., VAV boxes). Specify that Contractor shall label the units accordingly, including the space being served. 5. Equipment, including motors, shall be stenciled with the proper class-subclass code and correct unit identification, using a contrasting color. B. The location of fire dampers above accessible ceilings shall be identified by a red circular dot at least ¾ in diameter or embossed tape adhered to the nearest ceiling grid member. C. Locations of air-handling devices which have filters and are above accessible ceilings shall be identified by a blue circular dot at least ¾ in diameter or embossed tape adhered to the nearest the nearest ceiling grid member. D. Coordinate mechanical identification with painting standards. Refer to standard Section 09900. 0.02 DEFINITIONS (Excerpts from ANSI A13.1-1981) A. Materials inherently hazardous 1. Flammable or explosive: materials which are easily ignited, including materials known as fire producers or those creating an explosive atmosphere. 2. Chemically active or toxic: Materials which are corrosive, or are in themselves toxic or productive of poisonous gases. 3. At temperatures or pressures: Materials which, when released from the piping, would have a potential for inflicting injury, or property damage by burns, impingement, or flashing to vapor state. B. Materials of inherently low hazard: Materials which are not hazardous by nature, and are near enough to ambient pressure and temperature that people working on systems carrying these materials run little risk through their release. C. Fire quenching materials: This classification includes sprinkler systems and other piped fire fighting or fire protection equipment. Includes water, chemical foam, CO 2, Clean Agent, etc. PART 1 GENERAL 1.01 REFERENCES A. American National Standards Institute (ANSI) 1. ANSI A13.1: Scheme for the Identification of Piping Systems 2. ANSI Z53.1: Safety Color Code for Marking Physical Hazards. B. American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) PART 2 PRODUCTS 2.01 IDENTIFICATION MATERIALS FOR PIPING AND EQUIPMENT A. Metal tags 15190 Page 1 of 5

1. Round brass discs, minimum 1-½" diameter, with edges ground smooth 2. Each tag punched and provided with brass chain for installation. B. Engraved nameplates 1. Laminated three-layer plastic with engraved black letters on light contrasting background color C. Pressure sensitive markers: Brady Type 350 flexible vinyl film identification markers and tape, with legend, size and color-coding per ANSI A13.1. D. Semi-rigid plastic identification pipe markers: Seton Setmark with legend, size and color-coding per ANSI A13.1. Direction-of-flow arrows are to be included on each marker, unless otherwise specified. 1. Diameters ¾" through 5": Setmark Type SNA markers 2. Diameters 6" or larger: Setmark Type STR markers PART 3 EXECUTION 3.01 IDENTIFICATION OF PIPING AND EQUIPMENT A. General 1. Provide pipe identification, valve tags, stencils, or engraved nameplates to clearly identify the mechanical equipment, piping and controls of the various mechanical systems and direction of flow in piping B. Methods for identification 1. Metal tags a) Stamp tags with letter prefixes to indicate service, followed by a number for location in system. 2. Engraved nameplates a) Attach nameplates with brass screws. b) Pressure-sensitive embossed labels are not acceptable. c) Nameplates shall bear the same identifying legend used on the Contract Documents. 3. Pressure-sensitive markers a) Apply pressure-sensitive markers with complete wrap-around. b) Test marker adhesion for permanence. c) Markers showing dogears, bubbles, or other failings shall be replaced. d) Place markers at all branches and at a maximum of 25 on center. 4. Semi-rigid plastic identification markers a) Seton Setmark pre-molded (not pressure-sensitive) identification markers may be used at Contractor's option on service piping which is accessible for maintenance operations (but not on piping in finished spaces). b) This type of marker shall not be installed on bare pipe when surface temperature exceeds 180 F unless a 1" thick insulation band is first provided under marker for protection from the hot pipe 15190 Page 2 of 5

C. Classification of hazards of materials, designation of colors and legend Classification Color of Field District Letters Legend Flammable or Explosive: Natural Gas Yellow Black NG Chemically Active or Toxic Yellow Black Acid Waste Yellow Black AW Chlorine Yellow Black C Extreme Temperatures or Pressures: Domestic Hot Water Yellow Black HW Domestic Hot Water Circulating Yellow Black HWC 180 o F Domestic Hot Water Yellow Black 180 F HW 180 o F Domestic Hot Water Circulating Yellow Black 180 F HWC Heating Water Supply with Glycol Yellow Black HWS/G Heating Water Return with Glycol Yellow Black HWR/G Low-Pressure Steam Yellow Black LPS Low-Pressure Steam Condensate Yellow Black LPSC High-Pressure Steam Yellow Black HPS High-Pressure Steam Condensate Yellow Black HPSC Boiler Feed Water Yellow Black BFW High-Pressure Compressed Air (over 90 Yellow Black CA Refrigerant Yellow Black REF Liquid or Liquid Admixture: Domestic Cold Water Green White W Distilled Water Green White DW Sanitary Sewer Green White SAN Waste Vent Green White V Storm Sewer Green White SS Chilled Water Supply with Glycol Green White CWS/G Chilled Water Return with Glycol Green White CWR/G Tower Water Supply Green White TWS Tower Water Return Green White TWR Gas or Gaseous Admixture: Medium-Pressure Compressed Air (30 to 90 Blue White CA XXPSI Low-Pressure Compressed Air (less than 30 Blue White CA XXPSI Vacuum Blue White VAC Fire-Quenching Materials: Water, Foam, CO 2, Clean Agent Red White FL Fire Lines Red White FL D. Piping 1. Identify all piping accessible for maintenance in crawl spaces, tunnels, above ceilings, and access spaces, as well as exposed-to-view, utilizing stenciled markings according to the following procedures. 15190 Page 3 of 5

a) Use an arrow marker for each pipe-content legend. The arrow shall always point away from the pipe legend and in the direction of flow. Color and height of arrow shall be same as content legend lettering b) If flow can be in both directions, use a double-headed arrow indication. c) Apply pipe legend and arrow indication at every point of pipe entry or exit where line goes through wall or ceiling cut. d) Apply pipe legend and arrow indication within three feet of each valve to show proper identification of pipe contents and direction of flow. e) The legend shall be applied to the pipe so that lettering is in the most legible position. For overhead piping, apply legend on the lower half of the pipe where view is unobstructed, so that legend can be read at a glance from floor level. f) For pipes under ¾" O.D., fasten brass tags securely at specified legend locations. g) Legends on steam piping, condensate return, compressed air, gas, and vacuum systems shall include working pressure or vacuum. E. Valves 1. System service valves, including fire protection, gas, vacuum and special service valves located inside the building shall be tagged and identified as to type of service. 2. Valves or cocks controlling branch mains or risers to various portions of the building shall be tagged and identified as to service and location number. F. Controls 1. Magnetic starters and relays shall have engraved nameplates to identify connecting or controlled equipment. 2. Manual operating switches, fused disconnect switches and thermal overload switches which have not been specified as furnished with indexed faceplates shall also have nameplates or be stenciled as to "connected" or "controlled" equipment. 3. Automatic controls, control panels, zone valves, pressure electric, electric pressure switches, relays, and starters shall be clearly identified. G. Pumps 1. Pumps shall be identified as to service and zones served. 2. Base-mounted pumps shall be stenciled or have system served nameplates. 3. Brass tags secured by tie wires may be used on small inline pumps. H. Storage tanks, water treatment equipment and heaters 1. Tanks and heaters shall be stenciled as to service. 2. The connecting pipes to each shall be identified and the service temperature entering and leaving the tank or heater shall be indicated. I. Fans 1. Supply and exhaust fans, air handling units, and connecting ductwork supplying one or more areas from an equipment room or isolated crawl or furred space shall have nameplate or be stenciled as to plan code number, service and areas of zones served. J. Air conditioning equipment 1. Equipment such as chillers, pumps, condensers, and rooftop equipment shall be identified by system nameplates. 15190 Page 4 of 5

2. Labels of remote equipment shall also indicate the space(s) being served and the location of their electrical breaker (panel ID, room number and circuit). 3. Refrigeration equipment shall be labeled with the type and approximate quantity of refrigerant. K. Access doors 1. Provide engraved nameplates to identify concealed valves, controls, dampers or other similar concealed mechanical equipment. Use the following colors for specified nameplates or labels. a) Red for fire-protection devices, including dampers b) Blue for air-handling devices c) Green for plumbing devices and piping L. Lift-out ceilings 1. Provide adhesive labels on ceiling grid to identify concealed valves, filters, fire/smoke dampers or similar concealed mechanical equipment that is directly above nameplate in the ceiling space. Use the following colors for specified labels. a) Red for fire-protection devices, including dampers b) Blue for air-handling devices c) Green for plumbing devices and piping M. Terminal units 1. Identify units with unique numbers corresponding to the drawings, and indicate the space being served. N. Motors controlled by energy management system 1. The District may furnish the following self-adhering signs which the Contractor shall install as indicated: CAUTION THIS EQUIPMENT IS UNDER COMPUTER CONTROL AND MAY CYCLE AT ANY TIME. BEFORE WORKING ON IT, DISCONNECT THE ELECTRICAL POWER AND CONTACT THE DISTRICT SERVICE DESK AT 720-423-4020. END OF SECTION 15190 15190 Page 5 of 5