Combined analytical and FEM method for prediction of synchronous generator no-load voltage waveform

Similar documents
Synchronous Generator Subtransient Reactance Prediction Using Transient Circuit Coupled Electromagnetic Analyses & Odd Periodic Symmetry

Contents. About the Authors. Abbreviations and Symbols

SYNCHRONOUS MACHINES

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

Generalized Theory Of Electrical Machines

The synchronous machine as a component in the electric power system

Code No: R Set No. 1

1249. Development of large salient-pole synchronous machines by using fractional-slot concentrated windings

Electromagnetic and thermal model for Brushless PM motors

Placement Paper For Electrical

Investigation of Magnetic Field and Radial Force Harmonics in a Hydrogenerator Connected to a Three-Level NPC Converter

Overview of IAL Software Programs for the Calculation of Electrical Drive Systems

3.1.Introduction. Synchronous Machines

Effects of Harmonic Distortion I

Bahram Amin. Induction Motors. Analysis and Torque Control. With 41 Figures and 50 diagrams (simulation plots) Springer

Motor-CAD Brushless PM motor Combined electromagnetic and thermal model (February 2015)

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

Winding Function Analysis Technique as an Efficient Method for Electromagnetic Inductance Calculation

Analysis of Indirect Temperature-Rise Tests of Induction Machines Using Time Stepping Finite Element Method

The power transformer

Generator Advanced Concepts

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

Code No: R Set No. 1

Finite Element Analysis of Cogging Torque in Low Speed Permanent Magnets Wind Generators

Progress In Electromagnetics Research B, Vol. 53, , 2013

Rotor Structure Selections of Nonsine Five-Phase Synchronous Reluctance Machines for Improved Torque Capability

ESO 210 Introduction to Electrical Engineering

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 4143/5195 Electrical Machinery Fall 2009

Effects of the Short-Circuit Faults in the Stator Winding of Induction Motors and Fault Detection through the Magnetic Field Harmonics

Electromagnetic Field Analysis and Motor Testing for the Development of Application Technology of Electrical Steel Sheets

Fuminori Ishibashi Shibaura Institute of

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

Conventional Paper-II-2013

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -100 Department of Electronics & Communication Engineering

Module 7. Electrical Machine Drives. Version 2 EE IIT, Kharagpur 1

Windings and Axes 1.0 Introduction In these notes, we will describe the different windings on a synchronous machine. We will confine our analysis to

Motor-CAD winding temperature model verification using Finite Element Analysis

Type of loads Active load torque: - Passive load torque :-

Synchronous Reluctance Machine: Combined Star-Delta Winding and Rotor Eccentricity

Module 1. Introduction. Version 2 EE IIT, Kharagpur

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

Modelling of a universal motor with speed control. Henrik Grop

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

PHYSICAL PHENOMENA EXISTING IN THE TURBOGENERATOR DURING FAULTY SYNCHRONIZATION WITH INVERSE PHASE SEQUENCE*

EE 350: Electric Machinery Fundamentals

OPTIMUM DESIGN ASPECTS OF A POWER AXIAL FLUX PMSM

Design and Performance of Brushless Doubly-fed Machine Based on Wound Rotor with Star-polygon Structure

EE 410/510: Electromechanical Systems Chapter 5

AC Machinery. Revised October 6, Fundamentals of AC Machinery 1

A Robust Fuzzy Speed Control Applied to a Three-Phase Inverter Feeding a Three-Phase Induction Motor.

Estimation of Core Losses in an Induction Motor under PWM Voltage Excitations Using Core Loss Curves Tested by Epstein Specimens

A Novel Harmonics-Free Fuzzy Logic based Controller Design for Switched Reluctance Motor Drive

PHYS 1441 Section 001 Lecture #22 Wednesday, Nov. 29, 2017

Power. Power is the rate of using energy in joules per second 1 joule per second Is 1 Watt

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

Jean LE BESNERAIS 26/09/ EOMYS ENGINEERING / /

ELECTRIC MACHINES MODELING, CONDITION MONITORING, SEUNGDEOG CHOI HOMAYOUN MESHGIN-KELK AND FAULT DIAGNOSIS HAMID A. TOLIYAT SUBHASIS NANDI

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Noise & vibrations due to magnetic forces in electrical machines

Analysis of Losses in High Speed Slotless PM Synchronous Motor Integrated the Added Leakage Inductance

PHYS 1444 Section 501 Lecture #20

IOCL Electrical Engineering Technical Paper

AGN 005 Fault Currents and Short Circuit Decrement Curves

A Simple Analytic Method to Model and Detect Non-Uniform Air-Gaps in Synchronous Generators

Modelling of Electrical Machines by Using a Circuit- Coupled Finite Element Method

Salient Pole Synchronous Generator Optimization by Combined Application of Slot Skew and Damper Winding Pitch Methods

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

LECTURE NOTES ON ELECTRICAL MACHINE-II. Subject Code-PCEL4302

SR Motor Design with Reduced Torque Ripple. George H. Holling

PAPER-II (Subjective)

CHAPTER 3 EQUIVALENT CIRCUIT AND TWO AXIS MODEL OF DOUBLE WINDING INDUCTION MOTOR

Proceedings of the International Conference on ENERGY and ENVIRONMENT TECHNOLOGIES and EQUIPMENT

Unequal Teeth Widths for Torque Ripple Reduction in Permanent Magnet Synchronous Machines With Fractional-Slot Non-Overlapping Windings

VALLIAMMAI ENGINEERING COLLEGE

Unit-4. Magnetic Circuits

Unbalance Detection in Flexible Rotor Using Bridge Configured Winding Based Induction Motor

Electric Circuits II Magnetically Coupled Circuits. Dr. Firas Obeidat

Multi-Objective Optimal Design of a NEMA Design D Three-phase Induction Machine Utilizing Gaussian-MOPSO Algorithm

Modeling and electromagnetic transients study of two 1800MVA phase shifting transformers in the Italian transmission network

Beskrivelse av simuleringsmodell ==> Description of simulation model


CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Key Factors for the Design of Synchronous Reluctance Machines with Concentrated Windings

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

About the Vibrations that Occur in the Synchronous Motor on the Asynchronous Starting

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Preface...x Chapter 1 Electrical Fundamentals

Sensorless Control of a Novel IPMSM Based on High-Frequency Injection

Optimal Design and Comparative Analysis of Different Configurations of Brushless Doubly Fed Reluctance Machine

Modelling for Interior Faults of Induction Motors and Its Simulation on EMTDC

Detection of Broken Damper Bars of a Turbo Generator by the Field Winding

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

1. Explain in detail the constructional details and working of DC motor.

MATHEMATICAL MODELING OF POWER TRANSFORMERS

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

Induction motor with pole-changing winding for variable supply frequency

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

Transcription:

Combined analytical and FEM method for prediction of synchronous generator no-load voltage waveform 1. INTRODUCTION It is very important for the designer of salient pole synchronous generators to be able to predict the no-load voltage waveform in a fast and reliable way. This is above all true in the case of a design where a low number of stator slots per pole and per phase have been chosen to reduce costs. Knowing in advance the harmonics content of the no-load voltage is important for satisfying standards requirements (Telephone Harmonic Factor, etc.). Also the prediction of the losses due to currents in the damper bars, induced by the slot pulsation field, is important for the design. In this document a combined analytical and finite element method for prediction of the damper bar currents and the voltage waveform under no-load conditions will be presented. The method takes into account saturation effects as well as all geometrical data of the machine. The results obtained were compared to the results obtained from transient finite element simulations and, in one case, to the measured no-load voltage. These comparisons were done on several synchronous generators, in the range from 10MVA to 30MVA, including integer and fractional slot stator windings, and damper windings centered or shifted on the pole shoes. The described method was implented in a tool, which is currently used by one of our major industrial partners. Summarized, the method consists in calculating, using magnetostatic 2D finite element simulations, the magnetic coupling of the machine electrical conductors (damper bars, field and stator windings) for a certain number of positions of the rotor, considering the machine rotational periodicity. In a second step the damper bar currents and the no-load voltage can be calculated by solving the differential equation system formed of the inductances calculated in the first step. 2. MAGNETIC COUPLING OF THE MACHINE CONDUCTORS The magnetic coupling of the machines windings is calculated using magnetostatic 2D finite element simulations. As the stator has, seen from the rotor, a rotational periodicity of one stator slot pitch, the magnetic coupling has to be determined only for some positions of the rotor within one stator slot pitch. As the MMF caused by the damper bar currents is significantly lower than the MMF caused by the current in the field windings, the flux created by the damper bar currents is supposed not to influence the level of saturation of the generator. The magnetic coupling is therefore expressed in the form of differential inductances for a chosen main flux. The differential inductances are obtained using magnetostatic 2D finite element simulations. Figure 1. Flux caused by field windings and one damper bar, meshed geometry

3. ELECTRICAL CIRCUIT OF THE DAMPER CAGE AND CALCULATION OF THE DAMPER CURRENTS As the current in the field windings is considered constant and the machine is considered under no-load conditions, the field windings and the stator windings do not have to be modeled. The electrical circuit of figure 2 is associated with the damper cage. Figure 2. Electrical circuit associated to the damper cage As can be seen, each damper bar is modeled as one branch composed of a resistance and a voltage source. The resistance models obviously the resistance of the damper bar and the voltage source models the voltage induced, which is the derivative of the flux seen by the damper bar. For each loop in the electrical circuit (figure 2) the following equation can be written: dϕ j dϕ j + 1 R barj i barj R barj i + 1 barj + = 0 + 1 (1) dt dt The flux seen by the damper bars can be expressed as the sum of the contributions of the field windings and of the damper bars. The contribution of one damper bar can be expressed as the multiplication of the corresponding mutual differential inductance and the current in the damper bar. These equations form a system of linear differential equations which can be solved using a numerical method (e.g. Runge-Kutta). Figure 3 shows the MMF caused by the damper bar currents under no-load conditions and nominal main flux in the case of the second generator described in paragraph 5. Figure 3. MMF caused by damper bar currents

4. CALCULATION OF THE NO-LOAD VOLTAGE Having calculated the currents in all damper bars, the no-load voltage in each phase can be obtained by summing the derivatives of the flux seen by each conductor of the phase. The flux seen by each conductor can again be expressed as the sum of the contributions of the field windings and the N damper bars. In the case of the conductors on the stator the differential inductances and the values of flux caused by the field windings, calculated for some rotor positions within one stator slot pitch, have to be reassigned to the conductors on the stator after a rotation of the rotor of one stator slot pitch, for taking into account the new initial position of each conductor. This technique allows to use the magnetic coupling, calculated only for some rotor positions within one stator slot pitch, for any position of the rotor. The following formula was used for the numerical derivation of the flux: d ϕj ( t dt k ) ϕ j ( t k ) ϕ j ( t k 1 ) ----------------------------------------- t k t k 1 (2) 5. COMPARISON OF THE RESULTS The damper bar currents and the no-load voltage obtained with the described method were compared to the currents and the voltage obtained from transient finite element simulations and in one case also to the measured no-load voltage. Figure 4 compares the no-load voltage waveform of an existing generator (6.3kV, 11MVA, 750rpm, 50Hz) obtained with the described method to the no-load voltage obtained from transient finite element simulations. 8000 Line voltage Described method Transient FEM 9500 Line voltage Described method Transient FEM 9000 6000 4000 8500 2000 8000 Voltage [V] 0 Voltage [V] 7500-2000 -4000 7000-6000 6500-8000 6000 0.43 0.432 0.434 0.436 0.438 0.44 0.442 0.444 0.446 0.448 0.45 Time [s] 0.432 0.433 0.434 0.435 0.436 0.437 Time [s] Figure 4. Comparison of no-load voltage waveform

Figure 5 shows a comparison of the no-load voltage harmonics of the same generator, this time also comparing to the harmonics of the measured no-load voltage. A very good agreement of the results can be observed, not only comparing the described method to transient finite element simulations but also comparing to the harmonics of the measured no-load voltage. Figure 5. Comparison of the no-load voltage harmonics Figure 6 shows a comparison of the no-load voltage harmonics of another existing generator (10.6kV, 31.5MVA, 750rpm 50Hz) for τ s two cases: the real generator with damper cage shifted by ± --- on the pole shoe ( τ being the stator slot pitch) and a hypothetical 4 s case with damper cage centered on the pole shoe. Figure 6. Comparison of the no-load voltage harmonics Again very good agreement of the results can be observed. In all cases the agreement of the damper bar currents obtained with the described method with the currents obtained from transient finite element simulations was as good as the agreement of the no-load voltages. All calculations were performed on a desktop PC with Pentium 4 CPU (2.6GHz, HT) and 1GB of RAM, running Windows XP Professional. The calculations applying the described method (including the magnetostatic finite element calculations) were about 20 times faster than the transient finite element simulations performed for comparison.

6. CONCLUSION The modeling method presented in this article allows the prediction of the damper bar currents and of the no-load voltage of laminated salient pole synchronous generators with almost the same precision as transient finite element simulations do. At the same time simulation time was reduced by a factor of about 20. The magnetostatic finite element simulations, necessary for the determination of the magnetic coupling of the machines conductors, can be automatized and the calculation of the damper bar currents and the no-load voltage, based on the results of the finite element simulations has been implemented in a user-friendly, graphical tool, allowing comfortable application of the method. This tool is currently used by one of our major industrial partners. Figure 7. Tool implementing the described method In a next stage the method will be modified for analysis of the effects of various types of rotor eccentricity conditions and stator deformations in salient pole synchronous generators.