A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

Similar documents
Concept of Serial Communication

Cable and Port Specifications

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

Lecture #3 RS232 & 485 protocols

Universal RS232/CMOS to RS422/RS485 Converter

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

The I-2532 CAN to Fiber Converter

Integrity Instruments

Miniature Synchronous Multipoint Modems

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

ZCS485 User s Manual. Version ZYPEX, Inc.

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

MDR24x Wireless 2.4GHz Modem

CL4424. Industrial 2.4GHz ConnexLink. User s Manual Version 1.1

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Atrie WireSpan 600/610 MODEM User's Manual

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

Transceiver, Chassis Connectors, and Cable and Adapter Specifications

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

CONV232/422 SERIAL DATA CONVERTER

USER'S MANUAL. Model : K

Installation and Operation Manual HS-Q/N. 4-Channel High Speed Data Module MEGAPLEX-2100 MODULE

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

Interface converter G kbit/sec

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

Accutech BR20. DIN rail mounted base radio

CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice.

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

Myriad MD9612FP Flash Poll Rack-Mount Modem User s Guide MD9612FP USER S GUIDE XXX Page i REV. A

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

FOM-5A, 6A Asynchronous Fiber Optic Modems

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Z-5652 plus Series. 2D Image Hands-Free Scanner

1 What s in the shipping package?

M-Bus Master MultiPort 250L Installation and User Guide

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

CP485-4 User s Manual

RM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01

Programmable RS-232/RS-485 Transceiver

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

User Manual 455U-D Radio Modem

DTR-xxx-LC & DTR-xxx-LS. 3.3 Volt 2x5 LC connector OC-3 & OC-12 LED Transceivers. Parameter Symbol Minimum Maximum Units Storage Temperature T st

Wireless Communications Module Stand-Alone HE200WCM910 and SmartStack HE800WCM900 / HE-WCM900* * HE- denotes plastic case.

Fanuc Serial (RS232) Communications Information

Meter Bus Application ANALOG-BOARD Revision 5.1

M9606. FSK Modem. 5C Communications Inc.

2W UHF MHz Radio Transceiver

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

SP334 SP334. Programmable RS-232/RS-485 Transceiver. Description. Typical Applications Circuit

Modem E1. Modem-converter E1-L. Features. Contents

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

ECE 4510/5530 Microcontroller Applications Week 6 Lab 5

Fiber Optic Expansion Interface

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

Ready DIP28 PIC. with. socket

Appendix C RS-485 Network

1.0 Introduction. Related Products and Documentation

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

The i-7531 CAN Repeater

Logosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP

Hardware Guide. Control Made Simple. Model 401A Signal Generator

LCC-10 Product manual

I-2533CS series User Manual

Programmable RS-232/RS-485 Transceiver

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

GMS-xx GSR-IAxx User Manual Appendix Simple Interconnection Network

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

Stat-4 Stat-8 Stat-24

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA

Hardware Manual. PCD3.F240/PCD2.F2400 LON interface module for TP/FT-10 channel. Hardware Manual PCD3.F240/PCD2.F2400, LON interface module

+5V Multiprotocol, Software-Selectable Cable Terminator

Serial Communications RS232, RS485, RS422

User Manual. 905U-D Radio Modem. ELPRO Technologies Pty Ltd, 9/12 Billabong Street, Stafford Q 4053, Australia.

M7 Over-The-Air Protocol. Overview. Technical Brief AN187 Rev A1

DMP Electronics Inc Robotic Division

This section of the manual will document the Ad-Maestro s control ports, COMM Ports and their settings respectively.

TS4000 Radio Modem. User s Manual

CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003

Intermittent Vibration 0.075

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

Using the TB8100 Base Station as a Talk-Through, Community, or Linked Repeater

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis

Transcription:

A50/A51/A60 June 2008 (4th Edition) All Rights Reserved

Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter

Part II - A60 RS-232 Surge Protection A60 RS-232 Surge Protection Converter

A50/51/60 User s Manual The product described in this manual is furnished under a license agreement and may be used only in accordance with the terms of the agreements. Copyright Notice Copyright 2008 Moxa Inc. All rights reserved. Reproduction in any form without permission is prohibited. Trademarks MOXA is a registered trademark of Moxa Inc. All other trademarks or registered marks in this manual belong to their respective manufacturers. Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa. Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, the particular purpose. Moxa may make improvements and/or changes in this manual or in the product(s) and/or the program(s) described in this manual at any time. Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for its use, or for any infringements of rights of the fourth parties which may result from its use. This product could include technical or typographical errors. Changes are periodically made to the information herein; these changes may be incorporated in new editions of the publication.

MOXA Internet Services Customer s satisfaction is always our number one concern. To ensure that customers get the full benefit of our services, Moxa Internet Services have been built for technical support, product inquiry, new driver update, user s manual update, etc. The followings are the services we provide. E-mail for technical support address: support@moxa.com World Wide Web (WWW) Site for product info address: www.moxa.com

Table Of Contents Part I - A50/A51 RS-232 to RS-422/RS-485 Converter Chapter 1. Introduction. 1 1.1 Overview 1 1.2 Features and Specifications 2 1.3 Package Check List 5 Chapter 2. Installation.. 7 2.1 Installation Procedure 7 2.2 Switch Function Description 7 2.3 LED Indicators 8 2.4 RS-422/RS-485 Pinouts 9 Chapter 3. Operation 11 3.1 Point-to-point 12 3.2 Multidrop 14 3.3 Simplex/Transmit, Receive 17 3.4 Self Test 19 Appendix A RS-232 Pinouts and Cable Wiring.. 21 Appendix B Impedance Matching and Termination Resistors 25 Appendix C Troubleshooting. 27

Table Of Contents Part II - A60 RS-232 Surge Protection Chapter 1. Introduction 29 1.1 Overview 30 1.2 Features and Specifications 30 1.3 Package Check List 31 Chapter 2. Installation 33 2.1 Installation Procedure 33 2.2 LED Indicators 34 2.3 Self Test 36 Appendix A RS-232 Pinouts and Cable Wiring 37 Appendix B Troubleshooting.. 41

1 1 Introduction Overview The MOXA RS-232 to RS-422/RS-485 bidirectional converters, A50 and A51, are designed to convert unbalanced (single-ended) RS-232 signals to balanced (differential) RS-422/RS-485 signals, and vice versa. They are the best choices for those who want to control devices at longer distance and/or to communicate with several devices via merely one link, particularly in the industry area. Point-to-point, multidrop and simplex operations are available for most users' needs. RS-422/485 RJ-45 Connector Power Jack RS-232 RJ-45 Connector Outlook of A50 1 1-1

RS-422/485 RJ-45 Connector Power Jack RS-232 RJ-45 Connecto Features and Specifications Features Outlook of A51 Both A50 and A51 are RS-232 to RS-422/RS-485 bidirectional converters except that A51 has one more feature: isolation protection, which provides high voltage protection up to 2000V. All the switches, SW1 and SW2, of A50/A51 are designed to be inside of the converter to protect switch settings from unintended change and introducing communication error without any warning. Hence, it is necessary to take the two screws off and open the cover up if you need to change the operation mode via sliding the switches. The A50/A51 must be powered either from a DC +9V to +30V, 150mA power adapter or the pin 6 and pin 7 of the Terminal Block. LED indicators are provided to show the status of data transmitting/receiving, RTS signal and Power. To avoid over-current from the remote ground to converter's ground, an protect resistor has been added inside the A50/A51. Specifications Power Supply - DC +9V to +30V, 150mA Data Rate - Up to 921600 bps under 500 ft (0.15 Km) Distance - Up to 4000 ft (1.2 Km) under 115200 bps RS-232 RJ-45 Connector - Supports TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND RS-422/RS-485 RJ-45 Connector - 1-2

Introduction Supports TxDA, TxDB, RxDA, RxDB, GND RS-422/RS-485 Terminal Block Connector - Supports TxDA, TxDB, RxDA, RxDB, GND, PWR, PWR GND Switch - SW1 : for full/half-duplex mode SW2 : for Tx (driver) and Rx (receiver) state Isolation Protection - for A51 only, up to 2000V. Terminal Resistor - RT1 space reserved for RS-422/RS-485 receiver signal. Mounting Kit - Plastic Plates and screws for mounting A50/A51 on the wall or any surface. Mounting Screw RS-422/485 RS-232 Fixing Screw A50/A51 with Mounting Kit Package Check List Upon unpacking your A50 or A51 package, you should find the following items: A50 (or A51) RS-232 to RS-422/RS-485 bidirectional converter (with isolation protection if A51) One power adapter Mounting Kit A50/A51/A60 User's Manual 1-3

1-4

Introduction 1-5

2 2 Installation Installation Procedure As RS-232 or RS-422/RS-485 port are labeled clearly on the surface of the A50/A51 converter, please prepare the RS-232 cable (refer to Appendix A, RS-232 Cable Wiring) and decide the operation mode as well as 2/4-wire cable (refer to Chapter 3, Operation) in advance. Take off the two screws on top of the converter and open the cover up if you need to change the operation mode via sliding the switches. Switch Function Description JP AUTO 485 RTS 422 Inside look of A50/A51 1 2-1

Switch settings table of SW1 and SW2 is as follows: SW1 *Full-duplex mode Half-duplex mode Off On SW2 Pin1 Pin2 Pin3 Pin4 *TxD always enabled On Off X X TxD always disabled Off Off X X TxD enabled by RTS Off On X X *RxD always enabled X X On Off RxD enabled by /RTS X X Off On Note: * means default settings, X means don t care LED Indicators There are LED indicators for TxD, RxD, RTS, and PWR on top of A50/A51. The indicator is not lighted on when not connected with signal or power. On the contrary, it will be lighted on and be in one of the red, green or orange colors. TxD indicator stands for data transmitting from RS-232 to RS-422/RS-485. It shows green when connected and no data transmitting. It shows orange when connected and transmitting data. RxD indicator stands for data transmitting from RS-422/RS-485 to RS-232. It shows red when connected and no data received. It shows orange when connected and receiving data (In half-duplex mode, it shows red when line is not connected due to the characteristics of ICs for RS-485). RTS indicator is for RS-232 RTS signal. It shows red when connected and RTS signal turned on. It shows green when connected and RTS signal turned off. PWR indicator is red when power is on and not lighted when power is off or not connected. 2-2

Installation RS-422/RS-485 Pinouts RS-422/RS-485 interface with RJ-45 Jack connector or Terminal Block Connector is depicted as follows. RJ-45 Connector Terminal Block Connector 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 A50/A51 A50/A51 RJ-45 Jack Terminal Block Connector Pinouts Signals Connector Pinouts Signals 1 nc 1 TxD B 2 nc 2 TxD A 3 GND 3 RxD B 4 TxD B 4 RxD A 5 TxD A 5 GND 6 RxD A 6 Power GND 7 RxD B 7 Power Input 8 GND 9 nc 10 nc(not connected) Note : Pin 6 and Pin 7 of Terminal Block are for Power GND and Power Input, which is an alternate option for power adapter. Be careful that DO NOT confuse RS-422/RS-485 GND with Power GND. Note : Under half-duplex mode (SW1 in ON mode), the couples of (TxD B, RxD B) and (TxD A, RxD A) are shorted inside the converter for convenience. Users can save the trouble with shorting the wires. 2-3

2-4

3 3 Operation The A50 (or A51) supports 5 kinds of operations. They are: Point-to-point/4-wire Full Duplex Point-to-point/2-wire Half Duplex Multidrop/4-wire Full Duplex Multidrop/2-wire Half Duplex Simplex/Transmit, Receive Only All the operations are to be described below. And TA, TB, RA and RB represent TxD A, TxD B, RxD A and RxD B signal lines of the RJ-45 RS-422/RS-485 connector or the Terminal Block, respectively. Note : If possible, connect GND of both sides together to gain better signals. That is, you may need one more GND connection in addition to 4-wire or 2-wire connection. Note : For A51, connecting GND at the Terminal Block to the earth ground to provide a ground path to prevent electric shock caused by lightning, no matter RJ-45 or Terminal Block RS-422/RS-485 is used. A 3-1

Point-to-point Point-to-point configuration means two devices which locate at two different places can be linked together to communicate through a couple of A50 (or A51) converters. 4-wire Full Duplex A50/A51 A50/A51 TA RA DTE/ DCE RS-232 RS-422/ RS-485 TB RB RB RS-422/ RS-232 TB RS-485 DTE/ DCE RA TA GND GND In the graph, TA, TB, RA and RB could be either from RJ-45 or Terminal Block. The settings of the switches for each A50 (or A51) are as follows: SW1 SW2 Pin1 Pin2 Pin3 Pin4 Full-duplex mode Off TxD always enabled On Off X X RxD always enabled X X On Off 2-wire Half Duplex A50/A51 A50/A51 TA RA DTE/ DCE RS-232 TB RB RB TB RS-232 DTE/ DCE RS-485 RA GND TA GND RS-485 In the graph, TA, TB, RA and RB could be either from RJ-45 or Terminal Block. The settings of the switches for each A50 (or A51) are as follows: SW1 SW2 Pin1 Pin2 Pin3 Pin4 Half-duplex mode On TxD enabled by RTS Off On X X RxD enabled by / RTS X X Off On 3-2

Operation Multidrop Multidrop configuration means that more than two devices (Max. 10 for RS-422; Max. 32 for RS-485) can be linked all together to communicate one another through many A50 (or A51) devices. In this configuration, one of the A50 (or A51) will be connected to a master device and the rest of A50 (or A51) devices will be connected to any other slave devices. 4-wire Full Duplex A50/A51 A50/A51 Master DTE/ DCE RS-232 RS-485 TA TB RB RA RB RS-485 RS-232 TB Slave DTE/ DCE RA TA GND GND A50/A51 RA RB RS-485 RS-232 TB Slave DTE/ DCE TA GND In the graph, TA, TB, RA and RB could be either from RJ-45 or Terminal Blocks. The settings of the switches for each A50 (or A51) are as follows: SW1 Full-duplex mode Off SW2 for Master Pin1 Pin2 Pin3 Pin4 TxD always enabled On Off X X RxD always enabled X X On Off SW2 for Slaves Pin1 Pin2 Pin3 Pin4 TxD enabled by RTS Off On X X RxD always enabled X X On Off 3-3

2-wire Half Duplex A50/A51 A50/A51 Master DTE/ DCE RS-232 RA TB RB RA RB TB RS-232 Slave DTE/ DCE TA TA RS-485 GND GND RS-485 A50/A51 RA RB TB TA GND RS-485 RS-232 Slave DTE/ DCE In the graph, TA, TB, RA and RB could be either from RJ-45 or Terminal Block. The settings of the switches for each A50 (or A51) are as follows: SW1 SW2 Pin1 Pin2 Pin3 Pin4 Half-duplex mode On TxD enabled by RTS Off On X X RxD enabled by / RTS X X Off On 3-4

Operation Simplex/Transmit, Receive Simplex configuration means that more than two devices (Max. 10 for RS-422; Max. 32 for RS-485) can be linked all together to communicate through many A50/A51 devices. Its configuration is like the Multidrop's, but the master device can talk only and the slave devices can listen only. A50/A51 A50/A51 TA RA DTE/ DCE RS-232 RS-422/ RS-485 TB RB RB RS-422/ RS-232 TB RS-485 DTE/ DCE RA TA GND GND A50/A51 RA RB RS-422/ RS-232 TB RS-485 DTE/ DCE TA GND In the graph, TA, TB, RA and RB could be either from RJ-45 or Terminal Block. The settings of the switches for each A50 (or A51) are as follows: SW1 SW2 Pin1 Pin2 Pin3 Pin4 Full-duplex mode Off TxD always enabled On Off X X RxD always enabled X X On Off 3-5

Self Test This configuration is for A50/A51 self test. Run terminal emulation program to see if what you received is what you typed. A50/A51 DTE/ DCE RS-232 RS-422/485 TA TB RB RA GND In the graph, TA, TB, RA and RB could be either from RJ-45 or Terminal Block. The settings of the switches for each A50 (or A51) are as follows: SW1 SW2 Pin1 Pin2 Pin3 Pin4 Half-duplex mode On TxD always enabled On Off X X RxD always enabled X X On Off 3-6

A Appendix A RS-232 Pinouts & Cable Wiring RS-232 interface with RJ-45 connector is depicted as follows. RJ-45 Connector 1 2 3 4 5 6 7 8 9 10 A50/A51 RJ-45 Connector Pinouts RS-232 Signals 1 DCD Always On 2 DSR 3 RTS 4 GND 5 TxD 6 RxD 7 GND 8 CTS 9 DTR 10 - Note : Each group of (RTS, CTS) and (DTR, DSR) pins have been shorted on A50/A51, which release the users from the hardware flow control cable wiring problem. Thus, there are two types of RS-232 cable wiring which are listed below. Type 1: To connect RS-232 side of A50/A51 to a DTE (e.g. PC COM1/2) or DCE. (Please check the precise DTE/DCE pinouts, the following DTE/DCE pinouts is just an example) A A-1

A50/A51 DTE A50/A51 DTE RJ-45 Connector DB-25 Male RJ-45 Connector DB-9 Male 1 DCD 8 DCD 1 DCD 1 DCD 2 DSR 20 DTR 2 DSR 4 DTR 3 RTS 5 CTS 3 RTS 8 CTS 5 TxD 3 RxD 5 TxD 2 RxD 6 RxD 2 TxD 6 RxD 3 TxD 7 GND 7 GND 7 GND 5 GND 8 CTS 4 RTS 8 CTS 7 RTS 9 DTR 6 DSR 9 DTR 6 DSR A50/A51 RJ-45 Connector DCE DB-25 Female 1 DCD 8 DCD 2 DSR 6 DTR 3 RTS 4 CTS 5 TxD 2 RxD 6 RxD 3 TxD 7 GND 7 GND 8 CTS 5 RTS 9 DTR 20 DSR Type 2: To connect RS-232 side of A50/A51 to a DTE, e.g. terminal or PC COM1/2, with 3-pin wiring if don't care Hardware flow control. A50/A51 DTE A50/A51 DTE RJ-45 Connector DB-25 Male RJ-45 Connector DB-9 Male 5 TxD 3 RxD 5 TxD 2 RxD 6 RxD 2 TxD 6 RxD 3 TxD 7 GND 7 GND 7 GND 5 GND 3 RTS 5 CTS 3 RTS 8 CTS 8 CTS 4 RTS 8 CTS 7 RTS 2 DSR 20 DTR 2 DSR 4 DTR 9 DTR 6 DSR 9 DTR 6 DSR 1 DCD 8 DCD 1 DCD 1 DCD A-2

RS-232 Pinouts and Cable Wiring A50/A51 RJ-45 Connector DCE DB-25 Female 5 TxD 2 RxD 6 RxD 3 TxD 7 GND 7 GND 3 RTS 4 CTS 8 CTS 5 RTS 2 DSR 6 DTR 9 DTR 20 DSR 1 DCD 8 DCD A-3

A-4

B Appendix B Impedance Matching and Termination Resistors When an electrical signal travels through two different resistance junctions in a transmission line, the mismatch will sometimes cause signal reflection. Signal reflection causes signal distortion, which in turn will contribute communication errors. The solution to this problem is to establish the same impedance at the line ends as in the line itself by terminating them with resistors. It is normally sufficient when the value of the termination resistor equals the characteristic impedance of the transmission line. The resistors should be added near the receiving side. For example, A50/A51 TxDA TxDB RxDA RxDB Remote site RxDA RxDB TxDA TxDB Note: 1. stands for termination resistor near the receiving side. RT1 is the space reserved inside A50/A51 for this purpose. 2. The suggested termination resistor for AWG #26 cable is 100 ohm. 3. The suggested termination resistor for phone cable is 600 ohm. A B-1

B-2

C Appendix C Troubleshooting Q1. Failure of data transmission. Solutions: 1. Check that the right power adapter is applied. 2. Check that the RS-232 link is proper. 3. Check that the RS-422/RS-485 link is proper. 4. Check that the SW1 and SW2 are set properly. Q2. Data loss or error. Solution: Check that the data rate, data format are the same for both devices. Q3. How do I do self-test on A50/A51? Solution: Refer to Chapter 3.4 Self Test. B C-1

C-2

1 4 Introduction Overview The MOXA RS-232 Surge Protection converter, A60, is designed to protect the RS-232 communication line from TOV (Transient Over Voltages) which comes from lightning, electrostatic discharge and other forms. TOV is always the major factor which damages components and makes ports unreliable. To improve this problem, we add Transient Voltage Suppressor to our I/O ports to clamp surge voltage to protect ports from TOV. Due to the impulse signal generated by inductive devices in factory, the surge protection is best suited for the factory automation applications. RS-232 RJ-45 Connector Protection A60 RS-2 3 2 Su r g e Remote T R D D R C D X X T S T T C D D R R S S D Local Power Jack ( Not used ) RS-232 RJ-45 Connector Outlook of A60 Features and Specifications Features A60's main feature is surge protection up to 25KV. No switch is needed. No power

is needed. LED indicators are provided to show the status of data transmitting/receiving, modem control signals and DCD. Specifications RS-232 RJ-45 Connectors : supports TxD, RxD, DTR, DSR, RTS, CTS, GND, DCD RS-232 Terminal Block : supports TxD, RxD, DTR, DSR, RTS, CTS, GND LED Indicators : for TxD, RxD, DTR, DSR, RTS, CTS, DCD Surge Protection : up to 25KV, preventing surge from remote site. Mounting Kit : plastic plates and screws for mounting A60 on the wall or any surface. Protection A60 RS-2 3 2 Su r g e Mounting Screw Remote T R D D R C D X X T S T T C D D R R S S D T X D R X D R T S P W R Local A60 with Mounting Kit Fixing Screw Package Check List Upon unpacking your A60 package, you should find the following items: A60 RS-232 surge protection converter Mounting Kit A50/A51/A60 User's Manual ~4-2~

2 5 Installation Installation Procedure Even though the local and remote ports of A60's are labeled on the surface of the A60 converter, please take care when connecting the cables to the A60 and the hosts. Note that the surge from both the local and the remote site is blocked by the A60. However, the LED indicators and the local host are under surge protection if and only if the surge comes in from the remote port of A60. Hence, it is recommended to keep A60 as close as possible to the local host. Otherwise, you may risk damaging the A60 itself as well as the local host if surge occurs between the A60's local port and the host. In addition, you may need a couple of A60s, if both local and remote hosts are to be protected from surge. Note that remote port and Terminal Block are actually the same except that DCD signal is not available in Terminal Block. It is recommended to connect GND at the Terminal Block to the earth ground to provide a ground path to prevent electric shock caused by lightning, no matter RJ-45 or Terminal Block is used. 2000 25KV V Surge A60 Protection A60 RS-2 3 2 Sur g e To Remote Host Remote T R D D R C D X X T S T T C D D R R S S D Local Earth Ground To Local Host Please prepare the RS-232 cables, referring to Appendix A, RS-232 Cable Wiring.

LED Indicators There are LED indicators for TxD, RxD, DTR, DSR, RTS, CTS, and DCD on top of A60. The indicators are not lighted on when not connected with signals. On the contrary, they will be lighted on and be one of the red, green or orange colors. TxD indicator (signal from local port) Green : when connected correctly and no data transmitting. Orange : when transmitting data from local to remote site. RxD indicator (signal from remote port ) Green : when connected correctly and no data receiving. Orange : when receiving data from remote to local site. DTR/RTS indicators (signal from local port) Red : when connected and DTR (or RTS) signal turned on. Green : when connected and DTR (or RTS) signal turned off. DSR/CTS/DCD indicators (signal from remote port) Red : when connected and DSR (or CTS/DCD) signal turned on Green : when connected and DSR (or CTS/DCD) signal turned off. ~4~

Installation Self Test This configuration is for A60 self-test. Run terminal emulation program to see if what you received is what you typed. Protection A60 RS-2 3 2 Su r g e T X D R X D D T R D S R R T S C T S D C D Remote 1 2 3 4 5 6 7 Local In the above graph, all the signal lines could be either from remote site RJ-45 or Terminal Block and shorted as shown. ~5~

6 Appendix RS-232 Pinouts and Cable Wiring Below is RS-232 pinouts for RJ-45 connector or Terminal Block. RJ-45 Connector Terminal Block Connector 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 A60 RJ-45 A60 Terminal Block Connector Pinouts Signals Connector Pinouts Signals 1 DCD 1 TxD 2 DSR 2 RxD 3 RTS 3 DTR 4 GND 4 DSR 5 TxD 5 RTS 6 RxD 6 CTS 7 GND 7 GND 8 CTS 9 DTR 10 - There are two types of RS-232 cable wiring which are listed below. Note: 1. Terminal Block supports no DCD signal. 2. DTE: Data Terminal Equipment like terminal or PC COM1/2; DCE: Data Communication Equipment like modem. Please check the precise DTE/DCE pinouts, the following DTE/DCE pinouts is just an example.

Type 1: To connect RS-232 local/remote port of A60 to a DTE or DCE. DTE DTE A60 DB-25 Male A60 DB-9 Male DCD 8 DCD DCD 1 DCD DSR 20 DTR DSR 4 DTR RTS 5 CTS RTS 8 CTS TxD 3 RxD TxD 2 RxD RxD 2 TxD RxD 3 TxD GND 7 GND GND 5 GND CTS 4 RTS CTS 7 RTS DTR 6 DSR DTR 6 DSR A60 DCE DB-25 Female DCD 8 DCD DSR 6 DTR RTS 4 CTS TxD 2 RxD RxD 3 TxD GND 7 GND CTS 5 RTS DTR 20 DSR Type 2: To connect RS-232 local/remote port of A60 to a DTE with 3-pin wiring if don't care hardware flow control. DTE DTE A60 DB-25 Male A60 DB-9 Male TxD 3 RxD TxD 2 RxD RxD 2 TxD RxD 3 TxD GN 7 GND GND 5 GND RTS 5 CTS RTS 8 CTS CTS 4 RTS CTS 7 RTS DSR 20 DTR DSR 4 DTR DTR 6 DSR DTR 6 DSR DCD 8 DCD DCD 1 DCD ~7~

RS-232 Pinouts and Cable Wiring A60 DCE DB-25 Female TxD 2 RxD RxD 3 TxD GND 7 GND RTS 4 CTS CTS 5 RTS DSR 6 DTR DTR 20 DSR DCD 8 DCD ~8~

A 7 Appendix B Troubleshooting Q1. Failure of data transmission. Solutions: Check that the RS-232 link is proper. Q2. Data loss or error. Solution: 1. Check that the data rate, data format are the same for both devices. 2. Surge occurs during the data transferring. Error detection and recovery should be taken in applications. Q3. How do I do self-test on A50? Solution: Refer to Chapter 2.3, Self Test.