Vallabh Vidyanagar, Anand, INDIA

Similar documents
Chapter 7 Conclusion 7.1 General

INTERPRETATION METHODOLOGY TO IDENTIFY FAULT LOCATION IN A POWER TRANSFORMER

Matz Ohlen Director Transformer Test Systems. Megger Sweden

Field Experience with Sweep Frequency Response Analysis for Power Transformer Diagnosis

Investigating Mechanical Integrity in Power Transformer Using Sweep Frequency Response Analysis (SFRA)

Variation in SFRA plot due to design and external parameter

Performing reliable and reproducible frequency response measurements on power transformers

TesTIng of Power. Transformers are the largest, most. feature. By brandon dupuis

Effective maintenance test techniques for power transformers

Effective Maintenance Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

Research Article Transformer Winding Deformation Profile using Modified Electrical Equivalent Circuit

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Transformer condition assessment with an integrated test van

Transformers handling and transport

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

Benefits of SFRA - Case Studies

Importance of Transformer Demagnetization

Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 04, 2014 ISSN (online):

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser - OMICRON

Diagnostic testing of cast resin transformers

FAULT IDENTIFICATION IN TRANSFORMER WINDING

FRAX Series Sweep Frequency Response Analyzers

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

ISSN: [IDSTM-18] Impact Factor: 5.164

Fault Detection in Transformer Using Frequency (Sweep) Response Analysis

Demagnetization of Power Transformers Following a DC Resistance Testing

FRAX Series Sweep Frequency Response Analyzers

How to overcome undesirable effects ABSTRACT KEYWORDS. 1. Introduction

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

TECHNIQUES AND STANDARD

New Method for Transformer Winding Fault Detection

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

Presenting New Idea for Circumstance Monitoring of Transformers in Power Lines

Circuit design for reproducible on-site measurements of transfer function on large power transformers using the SFRA method

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Mitigating Murphy s Law While Test. Frédéric Dollinger

Automatic Transformer Winding Analyser

Shunt Capacitance Influences on Single-Phase Transformer FRA Spectrum

148 Electric Machines

ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER TRANSFORMER

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

Research Article Diagnosing Integrity of Transformer Windings by Applying Statistical Tools to Frequency Response Analysis Data Obtained at Site

Rarely used, problems with unbalanced loads.

ON-SITE TESTING OF SPECIAL TRANSFORMERS

Analysis of Frequency Response measurement results with end-to-end/interwinding test setup correlation

Test description for dry-type transformers chapter for special tests

Dielectric analysis of high-voltage power transformers DIAGNOSIS ABSTRACT KEYWORDS. 1. Introduction

ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER

C4-301 EXPERIMENTAL EVALUATION OF TRANSFERRED SURGES IN MV TRANSFORMERS FROM HV/LV

Using DFR to determine dissipation factor temperature dependence

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

Transient Recovery Voltage at Transformer Limited Fault Clearing

Specialists in HV and MV test and diagnostics. Testing in Substations

Problems connected with Commissioning of Power Transformers

EFFECT OF RADIAL AND AXIAL MOVEMENT OF WINDING ON COHERENCE FUNCTION IN A 220/132 KV, 100 MVA, AUTO TRANSFORMER

Ground Fault Detection using Zigzag Grounding Transformer in Ungrounded System

IVE(TY) Department of Engineering. Electrical Machines 1. Electrical Machines 1. Hour 13. slide 1

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

EXPERIENCE WITH DETECTION AND IDENTIFICATION OF WINDING BUCKLING IN POWER TRANSFORMERS. Victor V. Sokolov and Boris V. Vanin ZTZ-Service Company

Transformer Factory Testing

Testing and Diagnostic of Power Transformers & Distribution Transformers

IDAX 300 Insulation Diagnostic Analyzer. Dielectric Frequency Response Also known as: Frequency Domain Spectroscopy

The importance of partial discharge testing throughout the development and operation of power transformers

متلب سایت MatlabSite.com

Fuzzy Logic Based Identification of Deviations in Frequency Response of Transformer Windings

Test Report CESI A6/ Approved Page 1. MF Trasformatori s.r.l. - Calcinato (BS) Italy

FRAX Series Sweep Frequency Response Analyzers

New Intellectual Networks (Smart Grid) for Detecting Electrical Equipment Faults, Defects and Weaknesses

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

SAMPLE. Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs.

EFFECETIVE TRANSFORMER CONDITION ASSESSMENT

High Frequency Modeling of Two Limb Series Loop Winding for Partial Discharge Localization

Transformer Winding Deformation Analysis using SFRA Technique

The measurement and normalisation of dielectric dissipation factor for diagnostics of transformer insulation

Power Transformer Condition Assessment Based on Standard Diagnosis

Optimization of power transformers based on operative service conditions for improved performance

Advanced Test Equipment Rentals ATEC (2832)

Electrical Description

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

FRAX 101 Sweep Frequency Response Analyzer

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers

Onsite Mobile AC High Voltage Test System

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

ABB Power Products Service

CASE STUDY- FAULT IN POWER TRANSFORMER AT LOKTAK POWER STATION. - S K Mishra & S K Das NHPC Ltd O&M Division

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

GREEN TRAFO PRODUCTS SHR - THREE-PHASE SHUNT REACTOR

Be on guard for effective testing: Introduction

Introduction. AC or DC? Insulation Current Flow (AC) 1. TECHNICAL BULLETIN 012a Principles of Insulation Testing. Page 1 of 10 January 9, 2002

FIELD ELECTRICAL TESTING SPX TRANSFORMER SOLUTIONS, INC.

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland

Transcription:

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 9, Issue 1 Ver. V (Feb. 2014), PP 01-06 Interpretation of Sweep Frequency Response Analysis (SFRA) Traces for the Multiple Winding Faults which are Practically Simulated on the 10 KVA Power Transformer Akshay A. Pandya 1, Dr. B. R. Parekh 2 1 Research Scholar at SICART and Associate Professor, Department of Electrical Engineering, Birla Vishvakarma Mahavidyalaya Engineering College, Vallabh Vidyanagar, Anand, INDIA 2 Prof. & Head, Department of Electrical Engineering, Birla Vishvakarma Mahavidyalaya Engineering College, Vallabh Vidyanagar, Anand, INDIA Abstract : This paper presents how multiple winding faults can be detected by Sweep Frequency Response Analysis (SFRA). The test methods used by the authors for presenting the results are described. The Short Circuited Turns Fault on HV V phase winding and Earth Fault on LV V phase winding have been practically simulated simultaneously on the 10 KVA, 11000 V / 440 V, 3-phase, 50 Hz, Dyn11 Power Transformer which is specially designed and developed in-house. The result of these simulated faults are presented and discussed. The SFRA data analysis is performed on three phase comparison basis and a conclusion has been drawn from it. Keywords: Earth fault, Multiple winding fault, Power transformer, Short circuited turns fault, Sweep frequency response analysis. I. INTRODUCTION The SFRA is a powerful method for the detection and diagnosis of the defects in the active part of power transformers. It can deliver valuable information about the mechanical as well as electrical condition of core, windings, internal connections and contacts. No other single test method for the condition assessment of power transformers can deliver such a diversity of information. Therefore the SFRA is an increasingly popular test. The value of fingerprint data is more and more recognized by users all over the world. Comparing the time and frequency domain FRA test methods is seems to be obvious the SFRA, measuring directly in frequency domain, prevailed. Reproducibility is the key for a successful application of SFRA. [4] Comparison with other diagnostic techniques show that the key advantages of FRA are its proven sensitivity to a variety of winding faults and a lesser dependency on previous reference measurements, but there is a need for an objective and systematic interpretation methodology.[1] SFRA has been a key tool in the decision to scrap or reenergize a transformer. To get value from an SFRA test it is necessary to make sure that the measurements are credible, which requires good test technique and simple procedures; proper training is thus essential to control the measurement process. Subsequent interpretation of results is carried out with due respect to other tests and the context of the assessment are we making SFRA measurements as part of a routine assessment, or as part of a post-fault investigation? Finally we should make conclusions which are supported by evidence and relate to individual components of the transformer phases, windings, tap changers etc. [5] II. DESCRIPTION OF THE TRANSFORMER The Power Transformer of 10 KVA which is specially designed and developed in-house as shown in Fig. 1 for studying and analyzing SFRA Traces by doing practical simulation of various transformer damages on it. Some design details of the transformer may be found in Table 1 Fig. 1 10 KVA, 11000 V/440 V, 3-phase, 50 Hz, Dyn11 Power Transformer 1 Page

TABLE 1 BASIC DESIGN DETAIL FOR THE TEST TRANSFORMER Rated Power 10 KVA No. of Phases 3 Rated Frequency 50 Hz Winding Configuration Dyn11 Voltage Rating HV 11000 V LV 440 V Taping HV 10 nos. of taping provided uniformly LV No Taping No. of Turns HV 8100 No. LV 176 No. The HV delta connected winding has 10 nos. of uniform tapings where as LV star connected winding has no tapings. Voltage & No. of turns of HV Winding at each Tap is given in the Table 2. TABLE 2 Voltage & No. of turns of HV Winding at each Tap Tap No. Volts No. of Turns Tapping Range 1 11688 8100 + 6.25 % 2 11550 8004 + 5 % 3 11413 7909 + 3.75 % 4 11276 7814 + 2.5 % 5 11139 7719 + 1.25 % 6 11000 7623 0 % 7 10863 7528-1.25 % 8 10724 7432-2.5 % 9 10587 7337-3.75 % 10 10450 7242-5 % 11 10312 7146-6.25 % Note : Tap 1 Extreme Tap Tap 6 Normal Tap Tap 11 Lowest Tap III. TEST METHOD The main FRA test types are given below. 3.1 End-to-end or End-to-end open In the end-to-end open test, the signal is applied to one end of each winding in turn, and the transmitted signal is measured at the other end. The magnetizing impedance of the transformer is the main parameter characterizing the low frequency response below first resonance using this configuration. This test is the more commonly used because of its simplicity and the possibility to examine each winding separately. The end-to-end open tests can be made with the source applied on the phase terminal or on the neutral terminal. In principle, both should give similar results but the FRA user should specify the test set-up used and keep that information along with test data since it will influence the results. 3.2 End-to-end short-circuit This test is similar to the end-to-end measurement above, but with a winding on the same being shortcircuited. Such measurements allow the influence of the core to be removed below about 10-20 KHz because the low-frequency response is characterized by the leakage inductance instead of magnetizing inductance. The resonance at higher frequencies is similar to the one obtained using end-to-end measurement. The short-circuited winding can be floating or grounded. For three-phase transformers, there are two levels of variations, either per-phase or three-phase short-circuit. Furthermore, the end-to-end short-circuit tests can be made with the source applied on the phase terminal or on the neutral terminal. This test can be made if there is an interest in obtaining information related to the leakage impedance at low frequency, or removing uncertainties related to analysis of the core influence when residual magnetism is present. 3.3 Capacitive inter-winding The signal is applied to one end of a winding and the response is measured at one end of another winding on the same phase (not connected to the first one). By definition, this test is not possible between the series and common windings of auto transformers. The response using this configuration is dominated at low frequencies by the inter-winding capacitance. 2 Page

3.4 Inductive inter-winding The signal is applied to a terminal on the HV side, and the response is measured on the corresponding terminal on the LV side, with the other end of both windings being grounded. The low frequency range of this test is determined by the winding turns ratio. The choice of the list of the tests to perform should be adjusted depending on the purpose of the measurement. To obtain benchmark test values for future comparison or for general condition assessment, the four main FRA test types presented above should be performed. If the test involves a winding with regulation (tap winding) the measurements should be performed at maximum tap. If there are limitations on the time available to perform all the tests, it is recommended to perform only the end-to-end tests on all windings. [1] IV. PRACTICAL SIMULATION OF MULTIPLE WINDING FAULTS Authors have discussed here about the multiple winding faults, i.e. the short circuited turns fault on HV V phase winding and earth fault on LV V phase winding have been practically simulated simultaneously on the 10 KVA Power Transformer. Before doing practical simulation of transformer damages, first SFRA Testing has been carried out on healthy condition of the transformer. The SFRA Traces of this testing would be utilized as base line or previous data. The SFRA traces for the healthy condition of the transformer are shown in Fig. 2 to Fig. 4 Authors have performed total 9 test, End-to-end (6 tests) and End-to-end short-circuit (3 tests) on the power transformer at Tap 1 (Extreme Tap) for the healthy condition of the transformer. Note : 1. For HV Delta connected winding, Red color indicates frequency response of U phase (1U 1V), Yellow color for V phase (1V 1W) and Blue color for W phase (1W 1U) in Figures 2, 3, 5, and 6. 2. For LV Star connected winding, Red color indicates frequency response of U phase (2U 2N), Yellow color for V phase (2V 2N) and Blue color for W phase (2W 2N) in Figures 4 and 7. Fig. 2 HV LV Open Healthy Condition at Tap 1 Fig. 3 HV LV Short Healthy Condition at Tap 1 3 Page

Fig. 4 LV HV Open Healthy Condition at Tap 1 Authors have also performed total 9 test, End-to-end (6 tests) and End-to-end short-circuit (3 tests) on the power transformer at TAP 1 for the practically simulated multiple winding faults. The short circuited turns fault on HV V phase winding (1V Ph Tap Short) and earth fault on LV V phase winding (2V EF) have been practically simulated simultaneously on the 10 KVA Power Transformer. The short circuited turns fault on HV V phase winding was applied practically as per the details given in Table 2, whereas the earth fault was applied practically at the terminal of LV V Phase winding of the power transformer. TABLE 2 DETAILS OF PRACTICALLY SIMULATED SHORT CIRCUITED TURNS FAULT Total No. of Turns in HV Winding 8100 Due to HV Tapping Short 95 No. of Turns in HV V Phase (Tap 4 & 5 shorted) in V Phase winding are getting shorted % of No. of Turns shorted in V 1.172 % phase winding The Combination of SFRA responses of all 9 tests are shown in Fig. 5 to 7. Fig. 5 Tap No. 1 HV LV Open 2V EF-1V Ph Tap Short Fig. 6 Tap No. 1 HV LV Short 2V EF-1V Ph Tap Short 4 Page

Fig. 7 Tap No. 1 LV HV Open 2V EF-1V Ph Tap Short SFRA Data Analysis Data analysis is performed on three phase comparison basis and following points are analyzed. HV LV Open: Measured open circuit frequency responses of three phase of HV winding (11 KV, Delta) at Tap 1 are shown in Fig. 5 It is clear from the Fig. 5 that the response of V phase (1V 1W) (Middle Phase) is different than the outer phases and outer phases appear to be normal. In case of V phase winding the first resonance around 3.5 khz is absent. It can happen if the SFRA signal is getting internal short circuited path. HV LV Short Circuit: Measured short circuit frequency responses of three phase of HV winding at Tap 1 are shown in Fig. 6 It is clear from the Fig. 6 that the short circuit responses of all the three phases of HV winding are similar and have general shape. LV HV Open: Measured open circuit frequency responses of three phase of LV winding (440 V, Star) at Tap 1 are shown in Fig. 7 It is clear from the Fig. 7 that the response of V phase (2V 2N) (Middle Phase) is different than the outer phases and outer phases appear to be normal. The starting db value of phase V is -2 db whereas starting db value of other phases (U & W) is -7 db and the first resonance around 1.5 khz is absent in V phase response. The impedance value of phase V is lower in low frequency range (up to 1.5 khz) and high in medium & high frequency range as compared to the other phases (U & W). It can happen if the SFRA signal is getting earth fault path. V. Conclusion 1. HV Winding: Based on the above SFRA data analysis it is concluded that the transformer has developed short circuited turns fault in V (1V 1W) phase (i.e. V phase Tap short fault). It can be found from other conventional method like, No Load Excitation Current, Turns Ratio and Magnetic Balance test also. 2. When the first resonance in the low frequency range is absent in the open circuit frequency response of any phase of HV or LV winding and then it merges with the other open circuit frequency responses of two phases in the medium and high frequency range, than it indicates that the short circuited turns fault has been developed in that phase of that winding. 3. LV Winding: Based on the above SFRA data analysis it is concluded that the transformer has developed earth fault in V (2V 2N) phase. It is possible to identify Earth Fault by other conventional method like, Tan Delta, Exciting Currents, Insulation Resistance, and TTR also. 4. When the open circuit frequency response of any phase of star connected winding shows that the impedance value of it is lower in low frequency range and high in medium & high frequency range as compared to the other healthy phases than it indicates that the earth fault has been developed in that phase of star connected winding. 5. Based on the above SFRA data analysis it is concluded that the transformer has developed multiple winding fault, i.e. short circuited turns fault (i.e. Tap short fault) in V phase of HV winding and earth fault in V phase of LV winding. SFRA is able to identify both the faults very clearly which is not possible to achieve by only single test by any other method. It is the experience and interpretation of SFRA results plays a major role in identifying such multiple faults in transformer. 5 Page

Acknowledgements The authors gratefully acknowledge the contributions of Mr. Tushar G. Patel and Mr. Snehal G. Mehta to the SMS Sabarmati, GETCO, Gujarat, INDIA REFERENCES [1] CIGRE Working Group A2.26, Mechanical Condition Assessment of Transformer Windings Using Frequency Response Analysis (FRA), Brochure 342, Paris, April 2008. [2] Aradhana Ray, Application of Signal Processing Techniques for Condition Monitoring of Electrical Equipment," Ph.D. thesis, Dept. of Electrical Engineering, Univ. M.S., College Faculty of Technology & Engineering, September 2009. [3] IEC 60076 18 Ed.1: Power Transformer Part 18, Measurement of Frequency Response, United Kingdom, July 2012. [4] A. Kraetge, M. Kruger, J. L. Velasquez, H. Viljoen, A. Dierks, Aspects of the Practical Application of Sweep Frequency Response Analysis (SFRA) on Power Transformer, 6 th Southern Africa Regional Conference CIGRE 2009. [5] G. Matthew Kennedy, Charles Sweetser and Tony McGrail, Field Experiences with Sweep Frequency Response Analysis, Doble Engineering Company 73 rd Annual International Doble Conference, 2006 [6] IEEE PC 57.149 Guide for the Application and Interpretation of Frequency Response Analysis for Oil Immersed Transformer, March 2013 6 Page