Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4, 0.25 16 and 1 64 AC, 50/60 Hz or DC 600V AC maximum 300V DC maximum Relays with fixed time delay Sealed contacts Harsh environments Hazardous locations Class I, Div. 2, Groups A, B, C and D Standards Compliance ISA 12.12 CSA C22.2, No. 213 Certifications culus Listed (File No. E10314, Guide NOIV/NOIV7) Product Selection Bulletin 700 RTC Relay Relays with Provision for Instantaneous Contacts Relays listed below have slots for two timed contacts and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges.
Number of Contact Cartridges Open Type Without Enclosure Total Instantaneous Timed N.O. N.C. N.O. N.C. 0 0 0 0 0 700-RTC00000Ä 1 0 0 1 0 700-RTC00100Ä 0 0 0 1 700-RTC00010Ä 2 0 0 2 0 700-RTC00200Ä 1 0 1 0 700-RTC10100Ä 0 1 1 0 700-RTC01100Ä 0 0 1 1 700-RTC00110Ä 1 0 0 1 700-RTC10010Ä 0 1 0 1 700-RTC01010Ä 0 0 0 2 700-RTC00020Ä 3 1 0 2 0 700-RTC10200Ä 2 0 1 0 700-RTC20100Ä 0 1 2 0 700-RTC01200Ä 1 1 1 0 700-RTC11100Ä 1 0 1 1 700-RTC10110Ä 2 0 0 1 700-RTC20010Ä 0 2 1 0 700-RTC02100Ä 0 1 1 1 700-RTC01110Ä 1 1 0 1 700-RTC11010Ä 1 0 0 2 700-RTC10020Ä 0 2 0 1 700-RTC02010Ä 0 1 0 2 700-RTC01020Ä 4 2 0 2 0 700-RTC20200Ä 1 1 2 0 700-RTC11200Ä 2 0 1 1 700-RTC20110Ä 0 2 2 0 700-RTC02200Ä 1 1 1 1 700-RTC11110Ä 2 0 0 2 700-RTC20020Ä 1 1 0 2 700-RTC11020Ä 0 2 1 1 700-RTC02110Ä 0 2 0 2 700-RTC02020Ä Ä Coil Voltage Code The as listed is not complete. Select a voltage code from the table below to complete the Example: 700-RTC00100Ä becomes 700- RTC00100U24. For other voltages consult your local Rockwell Automation sales office or Allen-Bradley distributor. [V] 24V DC, 24V AC 120V DC, 110/120V AC 50/60 Hz U24 U1 Bulletin 700 RTC Relays with Fixed Time Delay Relays with Provision for Instantaneous Contacts Relays listed below have slots for two timed and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges.
Number of Contact Cartridges Open Type Without Enclosure Total Timed Instantaneous N.O. N.C. N.O. N.C. 0 0 0 0 0 700-RTC00#0Ä 1 1 0 0 0 700-RTC10#0Ä 0 1 0 0 700-RTC20#0Ä 2 2 0 0 0 700-RTC40#0Ä 1 0 1 0 700-RTC11#0Ä 1 0 0 1 700-RTC12#0Ä 1 1 0 0 700-RTC30#0Ä 0 1 1 0 700-RTC21#0Ä 0 1 0 1 700-RTC22#0Ä 0 2 0 0 700-RTC50#0Ä 3 2 0 1 0 700-RTC41#0Ä 1 0 2 0 700-RTC14#0Ä 2 0 0 1 700-RTC42#0Ä 1 0 1 1 700-RTC13#0Ä 1 1 1 0 700-RTC31#0Ä 0 1 2 0 700-RTC24#0Ä 1 0 0 2 700-RTC15#0Ä 1 1 0 1 700-RTC32#0Ä 0 1 1 1 700-RTC23#0Ä 0 2 1 0 700-RTC51#0Ä 0 1 0 2 700-RTC25#0Ä 0 2 0 1 700-RTC52#0Ä 4 2 0 2 0 700-RTC44#0Ä 2 0 1 1 700-RTC43#0Ä 1 1 2 0 700-RTC34#0Ä 2 0 0 2 700-RTC45#0Ä 1 1 1 1 700-RTC33#0Ä 0 2 2 0 700-RTC54#0Ä 1 1 0 2 700-RTC35#0Ä 0 2 1 1 700-RTC53#0Ä 0 2 0 2 700-RTC55#0Ä Operating Mode Replace the # in the cat. no. with the appropriate letter and numbers to indicate the operating mode and the fixed time delay value. Refer to operating mode table below. Digit Operating Mode Fixed Time Delay S On Delay s Seconds Two digits indicating the fixed time delay in seconds. Three digits indicating the fixed time delay (first digit indicates seconds, next Z Off Delay s two digits indicate 1/100 seconds). Y On Delay Min. Minutes Two digits indicating the fixed time delay in minutes. Three digits indicating the fixed time delay (first digit indicates minutes, next I Off Delay Min. two digits indicate 1/100 minutes). Examples: 700-RTC00Y200U1 is for a relay without contact cartridges. Y20 indicates an On-Delay timer with a 20 minute fixed time delay. This is a standard relay. Order the contact cartridges separately. 700-RTC42S020U1 is for a relay with 2 N.O. cartridges in the timed position and 1 N.C. cartridge in the instantaneous position. S02 indicates an On-Delay timer with a 2 second fixed time delay. Ä Coil Voltage Code The cat. no. as listed is not complete. To complete the cat. no., add a coil code selected from the table below. [V] 24V DC, 24V AC 120V DC, 110/120V AC 50/60 Hz U24 U1
Description Cartridge Type Color Cat. No. Contact Cartridges These cartridges are used to add contacts to timing relays having unused slots. The N.O., N.C., and Dummy cartridges are interchangeable and can be used in timed or instantaneous contact slots. Dummy cartridges should be placed in unused cartridge slots to guard against entrance of foreign material. N.O. Grey 700-CRT5 N.C. Orange 700-CRT6 700-CRT5 700-CRT6 700-CR9 Dummy Cartridge Black 700-CR9 Type 1 Enclosure Use for all Bulletin 700 P relays except 10 and 12 pole DC relays or 6 pole DC Bulletin 700 PH relays. 700-N31 Relay Rail Simplifies panel layout. These indexed strips are easily cut to the required length and bolted, riveted, or spot-welded in place. Relays are installed adjacent to one another on the mounting strip with the captive mounting screws provided. Rows of relays on Relay Rail form their own wiring trough. Can be used with the following relays: 700P, 700DC-P, 700S-P, 700N, 700-R, 700-RTC Relays per Strip 4 5 Pkg. Quantity 700-MP4 8 5 700-MP8 12 5 700-MP12 16 5 700-MP16 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 199-DR1 DIN Rail Adapter Can be used with the following relays: Bulletin 700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC 1 700-DRA Voltage and Power Requirements AC Voltage +10% 15% 50/60 Hz Total Power Required Initiate Terminal Power Maximum Allowable Leakage Current Coil Code 24V AC 8 VA 4 VA 10 ma U24 110/120V AC 9 VA 4 VA 2.4 ma U1 DC Voltage +10% 20% Total Power Required Initiate Terminal Power Maximum Allowable Leakage Current Coil Code 24V DC 10 W 5 W 10 ma U24 120V DC 11 W 5 W 2.4 ma U1
Type Contact Rating (See pub. 700-SG003*) Contact Arrangement Contact Material Operating Mode Timing Range Reset Time Repeat Accuracy Mounting Surge Suppression Haz. Loc. Ratings 700-RTC NEMA B600 600V AC, 5 A NEMA P300 300V DC, 5 A 1 4 poles. Max. of 2 timed and 2 instantaneous. Available in any combination of N.O. and N.C. contacts W (tungsten in a controlled gas atmosphere) Convertible to ON-Delay or OFF-Delay 0.015 64 minutes; 0.05...120 seconds 25 ms ±1% (or ±50 ms) at constant voltage and temperature Panel or strip mount Not required. Timers have internal suppression Class I, Division 2, Groups A, B, C, and D Maximum Allowable Leakage Current 24V AC/DC 10 ma 110/120V AC, 120V DC 2.4 ma Ambient Temperature Operating: Storage: 20 +60 C ( 4 +140 F) 20 +60 C ( 4 +140 F) Continuous duty units placed close to each other (3 in a row) have a temperature range of 20 +45 C ( 4 +113 F) or should have air circulated around the units. Approximate space of 3/4 in (mm) on all sides is needed. Typical Wiring Diagram Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes. Approximate Shipping Weight 0.92 kg (2.1 lb.) NEMA Type 1 Enclosure for RTC RelaysApproximate Shipping Weight 1.26 kg (2.8 lb.) Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.