Technical Guarantees No. WP_85

Similar documents
Guardrail T40 4MS2 BP for Bridge Parapet

TABLE OF CONTENTS. Impregnated... 1 NORDIC FENCE Fynbo FSC Certified... 1

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

Pole Line Hardware. Heavy-Duty Spool Rack (200 A) No. of Wires. Anti-Vibration Kit for Spool Rack. Heavy-Duty Spool Rack (400 A) No.

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

IFRC SHELTER TOOL KIT

CAM SYSTEM. Eccentric self-locking clamping devices. Set. CAM SYSTEM t. CAM SYSTEM t. Set. CAM SYSTEM s pag CAM SYSTEM s pag.

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

NPS/001/010 Technical Specification for Fasteners and Fixings for Wood Pole Overhead Lines and General Construction Works

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

PEC-TA Cast-in Channels and Bolts. Certified German quality for high-end fixing solutions. Advantages of using PEC Cast-in Channels.

Hex Cap Screws Coarse & Fine Thread

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

MEFA mounting accessories

isd dunaferr Product catalogue

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION

Connection Solutions for Wood-frame Structures. Copyright Materials. Learning Objectives

Chemical composition. Type 2 as per F568: C ( ); P (max 0.048); S (max 0.058); Mn (min 0.74); B (min );

STRUCTURAL BRACKETS CATALOGUE

CONTENTS AND SERVICES

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

1.1. THREADED SLEEVES for different fixing purposes

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

STRUCTURAL BRACKETS CATALOGUE

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility

The Wood Products Council is a Registered Provider with. . Credit(s) earned on completion of this program will be

Midwest Roadside Safety Facility

Installation Instructions

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Midwest Roadside Safety Facility

015 : 1993 CEB STANDARD

Optimast Installation Method Statement. F108.

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt

Installation Instructions

Standard Specification for Carbon and Alloy Steel Nuts [Metric] 1

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

technical sheet facade stabilization anchors shoulder bolt type Description

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

Multi-Institutional Academic Health Science & Research Center Evansville, IN

How-To-build guide carport

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

User Manual and Installation Instructions

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

HSV EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

Art Thatch TM Umbrella Kit Installation Guide

Pole Mount Installation Manual

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

Nutec Bigsix Roofing Accessories

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

On-roof system Alpha + Product catalogue

Product design: Structural systems

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

HARDLOCK NUT RIM & HARDLOCK NUT BASIC

TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER

February 2004 RONDA. Circular Formwork Instructions for assembly and use

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

SecuAnch Roof Anchor System

Mast and Antennas for Field Day & Emergencies

Assembly Instructions for Model: MF110

DECK PERMIT APPLICATION PACKET

FRP GATES MM08 FRP GATES Rev. 3 COMPOSITE SOLUTION PAGE 1

Pole Line Hardware. Heavy duty spool rack SS401E 1 9 1/ SS802E / SS803E /

SDWH TIMBER-HEX Screw

A E D X E X C A C B A L B E L E T R T A R Y

ODOT ITB Group 4 Item 33 Qty. 1

The Influence of Nails and Plasterboard on the Racking Resistance of Stud Walls

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

Football Goals 7,32x2,44 m

INSTALLATION PROCEDURE FOR TENSION CONTROL BOLTS

UP139 CRUISE-A-LONG (STANDARD) NATURAL COATED DECK COATED RAMP DESCRIPTION SQUIRREL PANEL BACK WALL CLEAR BUBBLE CRUISE RAIL SQUARE SPIRAL WHEEL 90 AN

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

DYNABOLT PLUS ANCHORS DYNABOLT PLUS. Anchor Details. Installation Ramset Regions. Site Map. Home Page. Performance. Next Page. Date of Issue: 9/98

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Building small wooden boats in Myanmar

BOLTS AND NUTS Square Bolts( Table 1 ) Hex Nuts ( Table 7 ) Heavy Hex Nuts (Table 7) Heavy Hex Structural Bolts ( Table 2 )

Fitting Guide for ADSS Cables

Letter of Transmittal/Submittal

Load Tables, Technical Data and Installation Instructions

VERSA-LAM. An Introduction to VERSA-LAM Products

CERTIFICATE OF APPROVAL No CF 718 PILKINGTON GROUP LIMITED

UP133 CRAWL & TODDLE (STANDARD) NATURAL COATED DECK COATED RAMP FRONT WALL BACK WALL DESCRIPTION COATED STEPS 90 ANGLE BRACKET LEFT WALL RIGHT WALL CL

Datasheet: Douglas Fir Swing Frame suspension height 2,50 m (Art.-No ) incl. post shoes

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Tex-452-A, Rotational Capacity Testing of Fasteners Using a Tension Measuring Device

DIVISION 6 WOOD AND PLASTICS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Midwest Roadside Safety Facility

BRACE ASSEMBLIES FOR WIRE FENCES. What They Are - How They Work - How To Construct Them

Procedure for Wrench Calibration and Snug Tightening

Standard Specification for Carbons and Alloy Steel Nuts 1

MevaDec. Contents. Ref. No. Description / Application Product m² list kg

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

G.MG.A.2: Density. Regents Exam Questions G.MG.A.2: Density

Transcription:

Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. WP_85 Wooden Pole 8.5 m Long Top Diameter 150-180 mm Impregnated No Description Unit Requirements Offered Data 1 Name of Manufacturer 2 Country of Origin Notes, Remarks, Ref to Documentation Evaluation Committee Comments 3 Standard BS144, BS913, BS1990:Part1, BS4072 4 Height m 8.5 5 Upper diameter (Min.-Max.) mm 150-180 6 Min. Diameter at 1.5m from butt mm 215 7 Species of timber Pine 8 Full Botanical Name Pinus Sylvestris 9 Pole Shape Generally Round, Free from Short Crooks, Top of the Pole shall be cut at an angle not less than 30º 10 11 For Unstayed Poles : Ultimate Breaking Load at 0.6 m from top of pole Where Stay are Used : Average ultimate fibre stress Poles Impregnated with Creosote By Rueping Process KN 8.2 KN 77.8 Yes/No 12 If Yes : Creosote Detained in Wood kg/m3 115 (min) Preserved Life Cycle of Wood year Studies and Documentation Branch 1/2

Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. WP_85 Wooden Pole 8.5 m Long Top Diameter 150-180 mm Impregnated No Description Unit Requirements Offered Data Notes, Remarks, Ref to Documentation Evaluation Committee Comments Poles Impregnated with Mixed Preparatus Yes/No 13 If Yes : Chemical Formula of Preparatus Net Dry Salt Amount in Pole Perserved Life Cycle of Wood kg/m3 year Relevant Reports and References 14 Type of Testes Sample and Routine Tests 15 Marking Required 16 Marking Plate Material Aluminium 17 Wooden Poles Marking Drawing Drawing No. WP_85 Tenderer s Signature :.. Date: Studies and Documentation Branch 2/2

THE MARKING OF THE WOOD POLES The wood poles shall be marked firmly by aluminium labels, which will contain the following information: - Type of the tree - Length (m) - Top diameter (cm) - Impregnation material - Impregnation year - The Abbreviation of the Firm Such marked aluminium plackets shall be nailed at 4 meter high measured from the base of the Pole.

Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. WP_14 Wooden Pole 14 m Long Top Diameter 200-220 mm Impregnated No Description Unit Requirements Offered Data 1 Name of Manufacturer 2 Country of Origin Notes, Remarks, Ref to Documentation Evaluation Committee Comments 3 Standard BS144, BS913, BS1990:Part1, BS4072 4 Height m 14 5 Upper diameter (Min.-Max.) mm 200-220 6 Min. Diameter at 1.5m from butt mm 300 7 Species of timber Pine 8 Full Botanical Name Pinus Sylvestris 9 Pole Shape Generally Round, Free from Short Crooks, Top of the Pole shall be cut at an angle not less than 30º 10 11 For Unstayed Poles : Ultimate Breaking Load at 0.6 m from top of pole Where Stay are Used : Average ultimate fibre stress Poles Impregnated with Creosote By Rueping Process KN 11 KN 44.4 Yes/No 12 If Yes : Creosote Detained in Wood kg/m3 115 (min) Preserved Life Cycle of Wood year Studies and Documentation Branch 1/2

Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. WP_14 Wooden Pole 14 m Long Top Diameter 200-220 mm Impregnated No Description Unit Requirements Offered Data Notes, Remarks, Ref to Documentation Evaluation Committee Comments Poles Impregnated with Mixed Preparatus Yes/No 13 If Yes : Chemical Formula of Preparatus Net Dry Salt Amount in Pole Perserved Life Cycle of Wood kg/m3 year Relevant Reports and References 14 Type of Testes Sample and Routine Tests 15 Marking Required 16 Marking Plate Material Aluminium 17 Wooden Poles Marking Drawing Drawing No. WP_14 Tenderer s Signature :.. Date: Studies and Documentation Branch 2/2

THE MARKING OF THE WOOD POLES The wood poles shall be marked firmly by aluminium labels, which will contain the following information: - Type of the tree - Length (m) - Top diameter (cm) - Impregnation material - Impregnation year - The Abbreviation of the Firm Such marked aluminium plackets shall be nailed at 4 meter high measured from the base of the Pole.

Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. TH_W20 ABC Tension & Suspension Twisted Hook For Wooden Pole through Bolt Pigtail Type M20X240 With Nut 3/4" No Description Unit Requirements Offered Data Notes, Remarks, Ref to Documentation Evaluation Committee Comments 1 Name of Manufacturer 2 Country of Origin 3 Reference Manufacturing Standards 4 Material 5 Construction Hot Galvanized Steel Nut and Washer and Fixed Washer 6 Total Length mm 345 7 Hook Diameter inch 3/4" (20mm) 8 Nut Failing Load KN 24 9 Dimensions As Drawing 10 Attached Drawing Drawing No TH_W20 Tenderer s Signature :.. Date: Studies and Documentation Branch 1/1

Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. TH_S20 ABC Tension & Suspension Hot Galvanized Steel Pole Thread Hook M20 Twisted ( 3/4") No Description Unit Requirements Offered Data Notes, Remarks, Ref to Documentation Evaluation Committee Comments 1 Name of Manufacturer 2 Country of Origin 3 Reference Manufacturing Standards 4 Material 5 Construction Hot Galvanized Steel Nut and Washer and Fixed Washer 6 Total Length mm 155 7 Hook Diameter inch 3/4" (20mm) 8 Nut Failing Load KN 24 9 Dimensions As Drawing 10 Attached Drawing Drawing No TH_S20 Tenderer s Signature :.. Date: Studies and Documentation Branch 1/1

Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. SCG_200 Hot Galvanized Steel Cable Guard No Description Unit Requirements Offered Data Notes, Remarks, Ref to Documentation Evaluation Committee Comments 1 Name of Manufacturer 2 Country of Origin 3 Description Cable Guard 4 Material Hot Dip Galvanized 5 Steel Guard with Steel Cover Required 6 Steel Guard and Steel Cover Length mm 2000 7 Steel Guard Wedth mm 200 8 Steel Cover Width mm 203 9 Steel Guard Edge Hight mm 105 10 Cover Edge Hight mm 26 11 Steel Guard and Steel Cover Thickness mm 1.5 12 Attached Drawing Drawing No. SCG_200 Tenderer s Signature :.. Date: Studies and Documentation Branch 1/1