National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Element Materials Technology Elbridge 4939 Jordan Road Elbridge, NY 13060 Mrs. Vicki Albertson Phone: 503-844-4066 Email: vicki.albertson@element.com http://www.nwemc.com ELECTROMAGNETIC COMPATIBILITY & TELECOMMUNICATIONS Emissions Designation IEC 61000-6-4 (2006-07) IEC 61000-6-3 (2006-06) IEC 61000-6-3 (2006) + A1 (2010) IEC 61000-6-4 (2006) +A1 (2010) EN 61000-6-4 (2007) + A1 (2011) EN 61000-6-3 (2007) + A1 (2011) EN 61000-6-3 (2007) EN 61326-2-1 (2013) Description Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard Electromagnetic compatibility (EMC). Generic standards. Emission standard for residential, commercial and light-industrial environments Electromagnetic compatibility (EMC) - Part 6-3: Generic standard - Emission standard for residential, commericial and light industrial environments and performance criteria for EMC unprotected applications For the National Voluntary Laboratory Accreditation Program Page 1 of 6
BS EN 61326-2-2 (2006-06) and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems EN 61326-2-1 (2006-05) and performance criteria for EMC unprotected applications EN 61326-2-3 (2013) Electrical equipment for measurement, control and laboratory use. EMC requirements - Part 2-3: Particular requirements -Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning EN 61326-2-2 (2013) AS/NZS CISPR 11 (2011) IEC/CISPR 11, Ed. 4.1 (2004-06) + A2 (2006) EN 55011 (2007) + A2 (2007) EN 55011 (2009) + A1 (2010) IEC/CISPR 11 Ed. 5 (2009-05) IEC/CISPR 11 Ed. 6.0 (2015) IEC/CISPR 11 Ed 5 (2009-05) + A1 (2010) EN 55022 (2006) + A1 (2007) EN 55022 (1998) + A1(2000) + A2(2003) and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Page 2 of 6
IEC/CISPR 22, Edition 5 (2005) + A1(2005) + A2 (2006) Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement IEC/CISPR 22, Edition 5 (2005-04) and EN 55022 (2006) EN 55022 (2010) IEC/CISPR 22 Ed. 6.0 (2008-09) IEC 61000-3-2, Ed. 3.0 (2005-11) IEC 61000-3-2, Ed. 3.0 (2005) +A1 (2008) +A2 (2009) EN 61000-3-2 (2006) + A1 (2009) + A2 (2009) EN 61000-3-2 (2014) IEC 61000-3-2, Ed. 4.0 (2014-05) EN 61000-3-3 (2013) IEC 61000-3-3 Ed. 3.0 (2013-05) ICES-001 ICES-003 Issue 5 (2012) ICES-003 Issue 6 (2016) Immunity Designation IEC 61000-6-1, 2nd edition (2005-03) Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment Electromagnetic compatability (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase) Electromagnetic compatability (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase) Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase) Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current = 16 A per phase) Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current = 16 A per phase) EMC- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low- voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current 16 A per phase and not subject to conditional connection Industrial, Scientific and Medical (ISM) Radio Frequency Generators Information Technology Equipment (ITE) - Limits and methods of measurement Information Technology Equipment (ITE) - Limits and methods of measurement Description Electromagnetic compatibility (EMC) - Part 6: Generic standards - Section 1: Immunity Page 3 of 6
IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard IEC 61000-6-2, Edition 2.0 (2005-01) IEC 61000-6-2 (2016) EN 61000-6-1 (2007) EN 61326-1(2006) Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments Electrical equipment for measurement, control and laboratory use - EMC requirements EN 61326-1 (2013) Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements EN 55024 (2010) Information technology equipment. Immunity characteristics. Limits and methods of measurement IEC 61000-4-2, Ed. 2.0 (2008-12) Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EN 61000-4-3 (2006) +A1 (2008) + A2 (2010) Electromagnetic compatibility (EMC). Testing and measurement techniques. Radiated, radio- Frequency, electromagnetic field immunity test IEC 61000-4-3, Ed. 3.1 (2008-04) Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test IEC 61000-4-3 Ed. 3.2 (2010) Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test IEC 61000-4-4 (2012-04) Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test IEC 61000-4-5, Ed 1.1 (2005-11) EMC - Part 4-5: Testing and measurement techniques - Surge immunity test EN 61000-4-5 (2014) Electromagnetic Compatibility (Emc) - Part 4-5: Testing And Measurement Techniques - Surge Immunity Test IEC 61000-4-6 Ed. 4.0 (2013) Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields IEC 61000-4-8 (2009) Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test IEC 61000-4-11, Ed. 2 (2004-03) & EN 61000-4-11 Product Safety Designation Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests Description Page 4 of 6
IEC 60601-1-2, Ed 2.1 (2004-11) & EN 60601-1-2 (2002) Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests IEC 60601-1-2, Ed. 3.0 (2007) IEC 60601-1-2, Ed. 4, (2014-02) IEC 60601-1-1 (2000-12), 2nd edition EN 60601-1-2 (2001) EN 60601-1-2 (2007) IEC 60601-2-4 ed3.0 (2010), Clause 202 EN 60601-2-4 (2003), IEC 60601-2-25 ed 2.0, (2011-10), IEC 60601-2-27:2005 EN 60601-2-27:2006 IEC 60601-2-27 ed3.0 (2011), IEC 60601-2-30 (1999), EN 60601-2-30 (2000) EN 60601-2-31 (2008) + A1 (2011) IEC 60601-2-47 (2006), EN 60601-2-47(2001) IEC 60601-2-47 Ed. 2.0 (2012-02), IEC 60601-2-49 ed2.0 (2011), EN 60601-2-24 (1998) Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests Medical electrical equipment-part 1-2: General requirements for basic safety and essential performance-collateral Standard: Electromagnetic disturbances-requirements and tests Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems Medical electrical equipment - Part 1 and Part 1-2: General requirements for safety: Collateral standard: EMC - Requirements and tests Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: EMC - Requirements and tests Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators Medical electrical equipment. Particular requirements for safety. Particular requirements for the safety of cardiac defibrillators Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs Particular requirments for the safety, including essential performance, of automatic cycling non-invasive blood pressure monitoring equipment Medical electrical equipment - Part 2-27: Particular requirements for the safety, including essential performance, of electrocardiographic monitoring equipment Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment Particular requirements for the safety including essential performance, of automatic cycling non-invasive blood pressure monitoring equipment Medical electrical equipment - Part 2-31: Particular requirements for the basic safety and essential performance of external cardiac pacemakers with internal power source Particular requirements for the safety, including essential performance, of ambulatory electrocardiographic systems Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment Medical electronic equipment Part 2-24: Particular requirements for the safety of infusion pumps and controllers Page 5 of 6
EN 60601-2-37 (2008) Medical electrical equipment - Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment ISO 80601-2-61 (2011), ISO 80601-2-56 (2009), ISO 80601-2-55 (2011-12) Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment EMC testing only Medical electrical equipment -- Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement EMC testing only Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors EMC testing only Page 6 of 6