DESCRIPTION The Paradise Datacom family of VSAT products can be configured in a variety of custom systems to meet any redundant system application. VSAT redundant systems can be configured to meet any output power level from 2W to 100W in Ku band or 5W to 170W in C Band. Creative application of the versatile system controller enables redundant system designs that provide the highest levels of system reliability while remaining cost effective. FEATURES Single Box Ku Band s to 10W Single Box C Band s to 20W C Band Booster Amplifiers to 170W Ku Band Booster Amplifiers to 100W Single or Dual Redundant Configurations OEM integration Remote M&C via the Controller OPTIONS External Power Supplies Redundancy Ethernet M&C Internal 10 MHz reference Transmit Only Systems Receive Only Systems Paradise Datacom LLC Phone: (814) 238-3450 328 Innovation Blvd. Fax: (814) 238-3829 State College, PA 16803 web: www.paradisedata.com
INDOOR EQUIPMENT OUTDOOR EQUIPMENT PLATE ASSY 950-1450 MHz, 10 MHz Ref,24VDC 4W, 8W Ku Band 5W C Band 950-1450 MHz, 10 MHz Ref,24VDC 4W, 8W Ku Band 5W C Band Summary Alarms J8 Controller Ext Alarms Switch Drive, Switch Drive, Ext Alarm ODU Control Cable PS1 Switch Cable PS2 950-1450 MHz, +15 VDC 950-1450 MHz, +15 VDC System w/o plate Configuration #1: Dual Redundant (Transmit & Receive) System in Chain Redundancy Advantages of Chain Redundancy s can be powered by Modem 10 MHz reference supplied by Modem Modem FSK control signal for M&C of reported by Modem Redundancy in IFL cabling s powered by Most Economical Redundant System Solution
INDOOR EQUIPMENT OUTDOOR EQUIPMENT 300W, 48VDC Power Supply +48VDC Power 300W, 48VDC Power Supply PLATE ASSY Controller +48VDC +48VDC 20W C Band Redundant 10 MHz Reference Wideband Combiner 950-1450 MHz, 10 MHz Ref PS1 20W C Band PS2 L Band In J8 Ext Alarms Switch Drive, Switch Drive, Ext Alarm ODU Control Cable Configuration #2: Transmit only () Redundant System Controller configured with redundant 10 MHz reference oscillators 10 MHz reference then diplexed onto IFL by the Redundant 48 VDC power supplies for 20W C Band s Single L Band IFL for Transmit and Receive
OUTDOOR EQUIPMENT 180-265 VAC to Booster 180-265 VAC to Booster / Booster PLATE ASSY 950-1525 MHz, 10 MHz 48 VDC 125W C-Band Booster -A A 5W C-Band 48 VDC Controller 125W C-Band Booster Switch Drive / Alarms / DC power -B -B +15 VDC 950-1525 MHz, 10 MHz 950-1525 MHz Bias Tee +15 VDC 950-1525 MHz Bias Tee Configuration #3: Dual Redundant (Transmit & Receive) System in Chain Redundancy Single Modem input with dual redundant RF converters configured with L band splitter for output and IF switch for input bias supplied by via the Switch / Control cable s are back-powered by AC/DC power supply in high power booster amplifier, eliminating the need for separate indoor power supplies. s configured with internal 10 MHz reference
INDOOR EQUIPMENT OUTDOOR EQUIPMENT 600W, 48VDC Power Supply +48VDC Power 600W, 48VDC Power Supply PLATE ASSY 5W C Band 60W Booster Amp Data Input Alarm Mute 1:1 Link Alarm Mute 950-1450 MHz, 10 MHz Ref,48VDC 950-1450 MHz, 10 MHz Ref,48VDC 5W C Band 60W Booster Amp J8 Parallel IO Ext Alarms Switch Drive, Switch Drive, Ext Alarm ODU Control Cable PS1 Switch Cable PS2 950-1450 MHz, +15 VDC 950-1450 MHz, +15 VDC Controller Configuration #4: Dual Redundant System with Chain Redundancy and Booster Amplifiers Controller along with Modem 1:1 internal controller handles chain redundancy with single data input. ODU configured with / 60W C Band Booster Amplifiers Redundant Power Supplies for Booster Amplifiers s powered by Modems s powered by Controller
C Band Outdoor RF Converter Configurations 5W 10W, 20W FAN 48 VDC for Booster from ODU power supply 40W, 60W /Booster PARADISE DATACOM 125W, 170W /Booster 180-265 VAC input power
Ku Band Outdoor RF Converter Configurations 2W,4W 8W, 10W FAN 48 VDC for Booster from ODU power supply Output Power 16 W 25 W 30 W 40 W PARADISE DATACOM 80W, 100W /Booster 180-265 VAC input power
General Transmitter Specifications PARAMETER C-Band KU-BAND Output Frequency Standard Band 5.85-6.425 GHz 14.0-14.5 GHz Waveguide Feed WR-137 WR-75 Waveguide Flange CPRG Grooved Output Power 5W - 170W 2W - 100W Gain Flatness + 2 db + 2 db Intermodulation (P1dB-3dB) -26 dbc -26 dbc Spurious in band -50 dbc -50 dbc Phase Noise IESS 308,309 compliant IESS 308,309 compliant General Specifications PARAMETER C-Band KU-BAND Standard Band with Internal Reference (+3 * 10-6 ) Option 1 External Reference (IDU Ref stability) Option 2 with Internal Reference (+3 * 10-6 ) Option 3 with Internal Reference (+3 * 10-6 ) Option 4 with Internal Reference (+3 * 10-6 ) 3.625-4.200 GHz 5.15 GHz 3.625-4.200 GHz 5.15 GHz 11.70-12.20 GHz 10.75 GHz 11.70-12.20 GHz 10.75 GHz 10.95-11.45 GHz 10.0 GHz 11.2-11.7 GHz 10.25 GHz 12.25-12.75 GHz 11.30 GHz IF Output Frequency 950-1525 MHz 950-1450 MHz Input Waveguide/Flange WR-229 Grooved WR-75 Grooved Noise Figure (typical) 25 K 65 K Conversion Gain 55-60 db 55-60 db Gain Flatness (any 40 MHz band) + 0.5 db + 0.5 db Output Power, P1dB 3 dbm 0 dbm Input / Output VSWR 2.2:1 2.2:1 Output Third Order Intercept +13 dbm +10 dbm Spurious -50 dbc -50 dbc Typical Phase Noise 100 Hz -60 dbc /Hz -57 dbc /Hz 1 KHz -70 dbc/hz -67 dbc/hz 10 KHz -80 dbc/hz -80 dbc/hz 100 KHz -90 dbc/hz -90 dbc/hz Input Power, +12 to +15 VDC 500 ma max 500 ma max
INPUT UNIT 1 UNIT 2 OUTPUT VSAT Redundant System Dual Redundant Controller Front Panel PARADISE DATACOM DUAL 1:1 REDUNDANT SYSTEM CONTROLLER FAULTS SUMMARY UNIT 1 UNIT 2 POWER SUPPLY PS1: XXXXX PS2: XXXXX SYSTEM: XXXXX AUX: N/A SW1: XXXXX SW2: XXXXX MAIN MENU LOCAL REMOTE AUTO MANUAL ENTER 3.47 [88.1] 19.00 [482.6] Rear Panel OUT B OUT A IN OUT IN A IN B J1 PS1 I O F U S E PLATE ASSY J4 SERIAL MAIN J5 SERIAL LOCAL J6 PROGRAM I O F U S E J2 PS2 J7 PARALLEL I/O J8 EXT ALARM J9 ETHERNET Features: Menu Driven LCD Display for user friendly monitor and control Front Panel Display of Signal Path for intuitive operation Parallel I/O; Form C Contact Closure Outputs & Opto-Isolated Inputs 2 Rack Unit height to maximize cabinet space RS-232/485 Serial Interface for Remote M&C Optional Ethernet Interface Audible alarms Redundant Power Supplies Field programmable firmware Windows TM based remote M&C Software +15VDC output for bias current monitoring for fault detection