Suitable firmware can be found on Anritsu's web site under the instrument library listings.

Similar documents
Cable and Antenna Analyzer

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

DSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

R&S FSH4/8/13/20 Spectrum Analyzer Operating Manual

Handheld Vector Network Analyzer + Spectrum Analyzer

Signal Generators for Anritsu RF and Microwave Handheld Instruments

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Please use a USB Memory Stick for firmware updates. Suitable firmware can be found on Anritsu's web site under the instrument library tab.

World s Most Trusted Family of Handheld RF and Microwave Analyzers

Cable and Antenna Analyzer for Anritsu s RF and Microwave Handheld Instruments

JD746A/JD786A CellAdvisor RF Analyzer

EXPERIMENT EM3 INTRODUCTION TO THE NETWORK ANALYZER

PLANAR R54. Vector Reflectometer KEY FEATURES

WE-525T Antenna Analyzer Manual and Specification

WE-2705P Antenna Analyzer

Agilent FieldFox RF Analyzer N9912A

Reflectometer Series:

Spectrum Master MS2711D

Instrument Messages and Functional Tests

On site RF troubleshooting for installation and maintenance

Site Master S331D MS2712

GC723A / GC724B Cable and Antenna Analyzer

Agilent CSA Spectrum Analyzer

AirScope Spectrum Analyzer User s Manual

Firmware Release 4.76

MS2760A a new approach for mm-wave and 5G spectrum measurements

Frequency and Time Domain Representation of Sinusoidal Signals

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

Model 7000 Series Phase Noise Test System

Keysight Technologies N9051B Pulse Measurement Software X-Series Signal Analyzers. Technical Overview

Services & Support General Caution Please use a USB Memory Stick for firmware updates.

AV3672 Series Vector Network Analyzer

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

VIAVI Solutions 3550 Series Software Release Notes

APPH6040B / APPH20G-B Specification V2.0

Impedance 50 (75 connectors via adapters)

Site Master Cable and Antenna Analyzer with Spectrum Analyzer

COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS. JD747A RF Analyzer

3GPP2 Signal Analyzer

S240. Real Time Spectrum Analysis Software Application. Product Brochure

PXIe Contents CALIBRATION PROCEDURE

Vector Network Analyzer for Anritsu RF and Microwave Handheld Instruments

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

Abstract: Stringent system specifications impose tough performance requirements on the RF and microwave cables used in aerospace and defense

LA Techniques Ltd

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Keysight Technologies FieldFox Handheld Analyzers

Keysight Technologies FieldFox Handheld Analyzers

A Walk Through the MSA Software Vector Network Analyzer Reflection Mode 12/12/09

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version

HP 33120A Function Generator / Arbitrary Waveform Generator

Vector Network Analysis

Keysight Technologies FieldFox Handheld Analyzers

LB680A Pulse Profiling USB PowerSensor+ Data Sheet

Confidence. on the Cutting Edge. Vector Network Analyzer Portfolio Brochure. In the Lab On the Manufacturing Floor In the Field. Anritsu Since 1895

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

Spectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar

PXA Configuration. Frequency range

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version 0.9.2

MS2711B Hand-Held Spectrum Analyzer

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Optoelectronic Components Testing with a VNA(Vector Network Analyzer) VNA Roadshow Budapest 17/05/2016

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version 0.10.x

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version 0.9.2

Site Master S331P. User Guide

FieldFox Handheld Analyzers

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

EE354 Spring 2016 Lab 1: Introduction to Lab Equipment

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.

LLS - Introduction to Equipment

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

A Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09

Quick Site Testing with the 8800SX

External Source Control

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

WIDEBAND MICROWAVE SIGNAL GENERATOR. SG24000H Compact, Low Phase-Noise, Wideband. Signal Generator Control

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

ECE 2111 Signals and Systems Spring 2009, UMD Experiment 3: The Spectrum Analyzer

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

Keysight MOI for MIPI D-PHY Conformance Tests Revision Oct, 2014

Vector Network Analyzers (VERY) Basics. Tom Powers USPAS SRF Testing Course 19 Jan. 2014

PN9000 PULSED CARRIER MEASUREMENTS

Project Description and Guidelines

Basic Transceiver tests with the 8800S

Advanced Test Equipment Rentals ATEC (2832)

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version 0.10.x

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

Green ADVANTAGES. Spectrum Analyzer Two models available: 24 GHz and 8 GHz SPECTRUM ANALYZER. Antenna Panel Inputs. Auxiliary Antenna Inputs OSCOR

Keysight Technologies FieldFox Handheld Analyzers

Keysight FieldFox Handheld Analyzers

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

Handheld Spectrum Analyzer. SpecMini. Transcom Instruments.

Spectrum Analyzer TEN MINUTE TUTORIAL

RF Tools. Supports most 8920A, 8920B, 8921A, 8924C units

ME1000 RF Circuit Design. Lab 4. Filter Characterization using Vector Network Analyzer (VNA)

Using Handheld Spectrum Analyzers to Find Hidden Signals

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

Transcription:

General Caution Please use a USB Memory Stick for firmware updates. Suitable firmware can be found on Anritsu's web site under the instrument library listings. If your existing firmware is older than v1.19, please use Master Software Tools and the Ethernet interface for firmware updates. If there is a firmware update question, please contact Anritsu service support at www.anritsu.com, and then click on "Technical Support" for further information. --- What will the Customer See in this release? MS2036A Application Package V1.21 2-10-2011 Vector Network Analyzer Application --- - Users can now input a specific marker frequency that does not snap to the nearest tested frequency. Spectrum Analyzer - - Fixed an issue with the display of antenna coefficient in field strength measurement. General Caution It is recommended that Ethernet be used to perform any firmware updates. If this failure should occur, Recovery is possible using the Emergency Repair feature with Ethernet connection.

What will the Customer See in this release? MS2036A Application Package V1.20 3-30-2010 - No customer changes. General Caution It is recommended that Ethernet be used to perform any firmware updates. If this failure should occur, Recovery is possible using the Emergency Repair feature with Ethernet connection. What will the Customer See in this release? MS2036A Application Package V1.19 2-25-2010 Master Software Tools compatibility --- - This version of firmware requires that v2.15 or newer of MST be used for USB connectivity. General Features - Antenna factors for several Japanese antennas corrected in default file - Added new USB firmware - Users will now be able to update the instrument firmware via a USB memory stick after this firmware update - Added new arrow style to application buttons with sub-menus - Will be solid and shown all the time - Added LTE channel information to the Signal Standards list Vector Network Analyzer Application ---

- Increased the number of cables in Table View to 12 in Vector Volt Meter. - User now can set the unit to turn off RF power when sweep is in hold. - Fixed a problem where the sweep stops when changing power from high to low while smoothing is on. Spectrum Analyzer - - Fixed a bug in recall setup that could cause a power measurement error. - Improved spur performance over previous version of firmware - New integrated code which includes the Spectrum Analyzer, Interference Analyzer, Channel Scanner, CW Signal Generator and Power Meter. This greatly speeds up mode switching between these four measurement modes General Spectrum Analyzer Bug Fixes - Fixed W and V issue in Field Strength measurement - Fixed Zero Span and Counter Marker incompatibility issue - Fixed Trace A-B -> C issue - Fixed Trace B & C Max & Min hold issues - Fixed 75O measurement issue Interference Analyzer Enhancements -- - New integrated code which includes the Spectrum Analyzer, Interference Analyzer, Channel Scanner and Power Meter This greatly speeds up mode switching between these four measurement modes Channel Scanner --------------- - New integrated code which includes the Spectrum Analyzer, Interference Analyzer, Channel Scanner and Power Meter This greatly speeds up mode switching between these four measurement modes

- Enabled numeric keypad for frequency and bandwidth entry in the customer setup menu. Power Meter Mode - New integrated code which includes the Spectrum Analyzer, Interference Analyzer, Channel Scanner and Power Meter This greatly speeds up mode switching between these four measurement modes High Accuracy Power Meter Application ----- - Support for new High Accuracy power sensors o o MA24108A Microwave USB power sensor 10 MHz to 8 GHz MA24118A Microwave USB power sensor 10 MHz to 18 GHz General Caution You must use Ethernet connection to perform any firmware updates. Updating via USB may result in a failure to finish loading the OS and the unit will not reboot. All is not lost. Recovery is possible using the Emergency Repair feature with Ethernet connection. What will the Customer See in this release? MS2036A Application Package V1.14 6-12-2009 General Features

No customer related changes in this package Vector Network Analyzer Application --- - Fixed a problem where the sweep would stop when changing power from high to low while smoothing is on. General Caution You must use Ethernet connection to perform any firmware updates. Updating via USB may result in a failure to finish loading the OS and the unit will not reboot. All is not lost. Recovery is possible using the Emergency Repair feature with Ethernet connection. What will the Customer See in this release? MS2036A Application Package V1.13 12-15-2008 General Features - Updated Signal Standards and Antenna files to fix errors - Minor improvement in power on booting time - Support for handling Compact Flash/USB drives > 4GB - Allow instrument to turn on even if there is a problem communicating with smart battery Channel Scanner Application -----------

- Added support for running scripts that will enable scanning of many more channels than standard offering. High Accuracy Power Meter Application ----- - Added support for MA24104A Inline High power sensor 600 MHz to 4 GHz Interference Analyzer Application - - Minor Signal ID algorithm enhancements Spectrum Analyzer Application ------------- - Fixed several bugs related to Markers and Limit lines - Users can now enter a specific marker frequency value without the instrument 'snapping' to the closest valid freq point - Added Support for Option 90 - Gated Sweep - Added a new Emission Mask measurement - Fixed bug where Saved Measurement files contain Trace B and Trace C data even though they are not being used. They are now saved only when the traces are ON when saving Vector Network Analyzer Application --- - Added support to allow peak search between markers 5, 6 - Fixed a bug where DTF setups wouldn't recall properly at certain frequencies Power Meter Mode -No Changes

What will the Customer See in this release? MS2036A Application Package V1.12 3-04-2008 General Features - No changes Operating System ------ - No changes VNA Mode -------- - Added dual overlay feature that shows live traces of S21 Log Magnitude and S11 Log Magnitude on the same graph. - Implemented new SCPI commands for Reference Plane Extension, Smoothing, Dual Overlay, and Smith Chart Reference Impedance. - Bigger fonts used for Vector Voltmeter CW table. - Big red "Not Calibrated" message will appear in the graph area when device is not calibrated. - Fixed a problem where Bias Tee is active even though the option is not selected. Spectrum Analyzer Mode ------ - Added Linear Units - Added vertical limit lines - Added limit mirror

- New SCPI commands for the above newly added features. - Fixed SCPI command :TRACe:DATA? so that it will always return data or #0 when data is invalid. - Traces not active when saved will not be recalled - Added capability to skip average count on the screen when it s sweeping faster than we can update the count on the screen - Fixed problem with trace values not adjusting to the Reference Level Offset changed. Interference Analyzer Application - - The reference level is now saved during mode changes. - Fixed a problem where changing Min/Max amplitude settings or using Autoscale improperly changes the displayed amplitude value of the input signal. - Fixed a bug where RSSI would stop taking measurements prematurely. - Error messages are now cleared from the screen correctly when switching between measurements. - The problem where markers are drawn a few pixels off from the actual location has been fixed. - RSSI measurements that do not fill the screen will no longer trigger incorrect warning messages. - Signal strength measurement will now be updated correctly when input is removed. Channel Scanner Application ----------- - Fixed a problem where changing Min/Max amplitude settings or using Autoscale improperly changes the displayed amplitude value of the input signal. High Accuracy Power Meter Mode -------------- -No Changes

Power Meter Mode -No Changes V1.11>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> What will the Customer See in this release? MS2036A Application Package V1.11 12-12-2007 General Features - In previous versions of firmware, SCPI command results for ":TRACe:DATA?" query would occasionally return incorrect values. All values are now properly calculated and formatted in the query response string. - In some situations the instrument may have failed to boot up completely using the previous version of firmware. This issue is now fixed. - Fixed a bug where the 'GPS High Accuracy' state for the internal frequency reference was lost when switching between certain modes. Operating System ------ - No changes VNA Mode -------- - Bias Tee Voltage user entry with 0.1 volt resolution. - Smith Chart Scaling (Amplitude) Menu for Reference Impedance (50 ohm or 75 ohm). - Smoothing of S11 and S21 Frequency Domain measurements with Smoothing % user entry. - Faster Vector Voltmeter (CW sweep) calibration steps.

- Faster sweep speeds by as much as 2 times. - Reference Plane Extension for port 1 (S11 and S21). Includes automatic reference plane extension using current measurement. - Improved spur avoidance down to 1 MHz. - Cal Mode (Standard or FlexCal ) for combinations of Cal Type (1-Port or 2-Port) and Cal Power (Low or High). - FlexCal remains valid when switching between Vector Network Analyzer and Vector Voltmeter Modes. >>> Note: Upgrading VNA module from older firmware version will do an internal cal (about 15 to 30 seconds) <<< System displays "** OPTIMIZING IF GAINS - PLEASE STAND BY **" message at bottom of bootup screen or application change to VNA. Remote Users: Remote interface was not updated to include new VNA features of Smith Chart scaling, trace Smoothing, Reference Plane Extension, or FlexCal. It is possible, however, that front panel use has placed the VNA Master in FlexCal mode without the knowledge of the remote controller. It is our recommendation that a :SYSTem:PRESet be performed prior to remote calibration to remove this potential cause for error. Spectrum Analyzer Mode ------ - Sweep improvements in graphic update of the screen - Front panel response speed up - Added Zero-span markers and limits - Added save/recall functionality for Trace B and Trace C - Added relative reference and scale for trace math - Added the message "*Settings changed, sweep data invalid*" when a sweep has not been completed with the new setting - Min/Max hold on Trace B

- Fixed a signal standard problem where changing span would invalidate the signal standard but not removing it from the screen - General speedup in SCPI and save/recall - Added resizable marker table - Added sweep rabbit - More robust limits - Fixed a problem where turning on Counter Marker in a narrow span would crash the system - New SCPI commands for Markers, limits, signal standards, save/recall, traces, occupied bandwidth, external frequency, and frequency steps - More stable sweep time - More robust GPS behavior - If averaging is on, manual trigger is now changed to trigger a sweep base on the number of averaging set. - No full screen support >>> NOTE: Only dbm unit supported. It will come in the next release. Interference Analyzer Application - - Failure of storage location (int CF, USB, ext CF) full is now displayed correctly. - There were previous problems with the autosave feature for RSSI and spectrogram measurements. In some cases, duplicate files were saved when the autosave was triggered. Also, some longer-duration measurements would terminate after only 3 hours. Both of these issues have been fixed. - Better reporting for spectrogram measurements trying to set very large save times in very large memory devices. Previously, this may have resulted in an error that said the device did not have capacity. - User is no longer allowed to modify the Min Sweep Time parameter when in RSSI mode. A message appears on the screen requesting that the user modify the Time Interval and Span parameters instead. - Previously, when doing a Preset from RSSI mode, the trace appeared to be squished on the left side of the graph when measurement is resumed under the preset conditions. Settings are now properly cleared during the preset operation.

- Display of parameters was improved in RSSI mode. Previously, when updating a parameter value, the red text in the upper-left of the plot on the display would get garbled as the parameter value (or parameter text) changed. The text would become clear again when the next point of data was received and displayed. This was most noticeable when the Time Interval parameter was large (i.e. 5 seconds). - Unit will not hang up in fast sweep conditions (large RBW, narrow span). - Error message display was improved so that critical error messages would not be missed. - Previously, the min/max parameters of the Signal Strength measurement could be set backwards (i.e. min > max). This is no longer allowed. - Improved autoscale feature of the Signal Strength measurement. Channel Scanner Application ----------- - Previously, recalling setups with custom channel scanning resulted in invalid, dashed-out channel numbers on the display. This has been fixed so that the correct channel numbers will be displayed. High Accuracy Power Meter Mode -------------- - Added support for MA24106A USB power sensors Power Meter Mode ------ - No change. V1.09>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> What will the Customer See in this release? MS2034A/MS2036A Application Package V1.09 8-2-2007 General Features - Antenna list handling improved so spaces in the file name are handled correctly.

- Power save increases battery time by decreasing default screen brightness. - Remote command functionality will now handle multiple events. - Critical data loss from EEPROM happened occasionally. Fixed by adding a checksum and created a copy of the data so that it could be restored if it is lost somehow. - Status window was not big enough to show all the results, now it is scrollable. - When saving files (setup, measurement, jpg) the first save displayed how many bytes were available. Now instead of displaying bytes (large number), we display GB, MB, or KB as appropriate. Operating System -- - Improved OS codeload process (mainly fixed OS codeload failures by verifying that Flash writes/erases are correct following each write). Vector Network Analyzer Mode ------------- -Frequency extended to 610 KHz. -Fixed a problem where marker can be a huge negative or positive number when using the twiddle to scroll marker to the far left or right. -Fixed integration failure retracing through 1.25 GHz bandswitch. -Fix for filters with VERY sharp filter skirts, with sweep speed improvements. -Update Dmax and Fault Resolution values after Preset. -Fault Resolution converts to Feet now as needed. -Fixed a problem to update the Dmax and Fault Resolution correctly when changing stop frequency. -Fixed a problem with recalling Stop Distance greater than the default Dmax. -Fixed Signal Standard parser problem with 0 up/down link frequencies. Spectrum Analyzer Mode ------

- Marker frequency resolution was lost on saved measurements. Now recalled measurements show the correct resolution. - Marker peak search on slow sweeps did not work correctly on the first sweep. Now the correct data is searched. - Extensive limit upgrades. Save/recall limit, limit envelope, limit absolute/relative, move limit (by frequency). - Application self-test displays overall status better now. - Some warning/error messaging has improved details. - Certain types of lock failures have been prevented. Also, one LO's failure should no longer cause another LO to fail. - Lock failure bug fixed to prevent occasional lock failures on some units. - Twiddle marker on full span would display as arrow off screen. Now marker stays on screen as expected. - Frequency step did not handle up/down arrows properly, now it does. High Accuracy Power Meter Mode -------------- - With max-hold on, when relative power is turned on the data would be lost. This bug has been fixed. Channel Scanner Mode ------ - No change. Interface Analyzer Mode ------ - No change. Power Meter Mode ------ - No change.