3 series Series with linear image sensor and electronic shutter provides accurate measurement. Laser displacement sensor features easy setup and operation. High accuracy of.1µm resolution and ±.1% F.S. linearity. Specular Type Specular type L-25 optics that are ideal for glass sensing. 279
SENSORHEAD VARIATI For general use Regular type Short distance Tire inspection -3 IEC Class 2 FDA CLASS Type -3-3R High power Class 3R Type Measurement range : 3 ±5mm Resolution : 1 m Linearity : ±.1% F.S. 3 Regular type Middle distance -85 IEC Class 2 FDA CLASS Type -85-3R High power Class 3R Type Checking clear package of IC mounted on PCB Measurement range : 85 ±2mm Resolution : 3 m Linearity : ±.1% F.S. Regular type Long distance Monitoring the die cast -35 IEC Class 2 FDA CLASS Type -35-3R High power Class 3R Type Measurement range : 35 ±1mm Resolution : 4 m Linearity : ±.1% F.S. For glass material Specular type Specular type L-25 IEC Class 1 FDA CLASS Type Monitoring warping sagging of glass plate Measurement range : 25 ±1mm Resolution :.1 m Linearity : ±.1% F.S. 28
SENSOR HEADS Series laser displacement sensor with linear image sensor and electronic shutter provides accurate measurement. 3 Measuring range General use -3 Short range : 3 ±5mm -3-3R 3mm 25mm 35mm Glass material L-25 Specular type : 25 ±1mm The optical path is designed to project the correct angle for the detection of specular reflections from transparent objects. 24mm 25mm 26mm 1mm 2mm -85-85-3R Middle range : 85 ±2mm 85mm 65mm 15mm 4mm -35-35-3R Long range : 35 ±1mm 25mm 35mm 45mm 2mm 281
Class 2 IEC/JIS CLASS II FDA laser product -3-85 -35 High power type (models with -3R ) has class 3 laser Class 3R - High power types -3-3R -85-3R -35-3R High speed sampling rate The Displacement sensor has a 1 sec. sampling rate and high density linear image detector. Conventional displacement sensor with slow response. Series sensors, high speed sampling rate improves overall accuracy. 3 For matte black objects or any application that requires a higher power laser, there are models of the series available which use a Class 3R light source. Class 1 IEC/JIS CLASS II FDA laser product L-25 IP67 Environmental rating The sensing heads of the series have an IP67 rating for use in applications where they may be exposed to water. L-25 is registered to CDRH. (Center of devices and radiological health) 282
CTROLLERS The controller is easy to operate with simple pushbutton setup and an LCD display to verify / change the settings. 3 LCD Display The A-N(or P) controller has a built-in color display that indicates multiple data values on the same screen. Distance values from both heads, calculated value, output status, bank number, etc. are displayed on the normal run screen. Light intensity monitor For L-25 only For stable measurement and improved accuracy the light intensity needs to be adjusted to the optimum setting. With the built-in monitor the status of the level can be verified. Red line on measuring point Threshold of receiving light intensity Further from head Closer to head Blue wave means reflection from the object. Convenient to find the peak reflection. Ten formulas of calculation A B A+B A-B -A-B K-A-B K+A+B K+A-B K+A K+B Sensor head A Sensor head B Adding of A and B Gap between A and B Reverse of A+B K = distance between sensors. Good for measuring thickness. K = Offset value K = Offset value Offset the sensor A. K = Offset value Offset the sensor B. K = Offset value Electronic shutter The microcomputer in the controller will automatically control the shutter speed depending upon the reflectance of the target. This will select the best light intensity level for accurate measurement and will help to minimize the error (AUTO Sensitivity Mode). Saturation level 8 Banks selections Bank No. Bank 2 input Bank 1 input Bank input 1 2 3 4 5 6 7 Sensing element Highly reflective materials will result in excessive reflected light that may cause an error in finding the peak position. Sensing element Sensing element Low reflective materials such as black rubber will have a very low amount of reflected light. This can cause unstable measurement. Automatic control of light intensity will find the peak correctly. Saturation level 283
3 RS-232C Communications By connecting the controller to a PC, the following operations can be performed from the PC via RS232. Writing and reading out the setting value Reading out the measurement value Reading out the control output status Operating the control input Data buffer function Communication method Transmission type Baud rate Transmission code Data length Stop bit length Parity check Data classification RS-232C Asynchronous 96/192/384/1152 bps ASCII 7/8 bit 1 bit Nil/Ever number/odd number STX ETX The underlined values are the factory default settings. Adjust the communication settings of the PC and the using the values in the above table. The settings of the controller can be accessed in screen number 14 (RS232C). Low / High pass filters High / Low pass filters are built into the controller. A low pass filter will help to reduce any sudden changes in the measurement while the high pass filter will eliminate slow gradual changes. Easy disconnection of QD type. 5 Independent outputs are available This is convenient for sorting items according to size. Each of the 5 comparator outputs can be set independently, all outputs have a high and low threshold limit. Output 5 E Two sensing heads can be controlled Therefore it computes for the purpose of measuring thickness, width, etc. Independent measurement from each head is possible as well. Any combination of measurement heads (3, 85, 35) can be used together. Output 4 D Output 3 C Output 2 B Output 1 A 284
Dimensions series sensor head Model No. : -3/-3-3R/-85/-85-3R Model No. : -35/-35-3R 3 34.3 (Beam receiving axis -35) 42.3 (Beam receiving axis -85) 19.1 (Beam emitting axis -35/-85) 75 1.5 25.6 75 1.5 27 66.6 4.2 3.9 66.6 4.2 3.9 69.6 78 5.8 6.5 5 (Beam receiving axis) 19.1 (Beam emitting axis) 69.6 78 5.8 6.5 2-M4 2-M4 4.2 4.2 Cable 5.5m with 1pin connector Cable 5.5m with 1pin connector L-25 Sensor head 75 1.5 25.6 66.6 4.2 3.9 Cable Model No. : CN-S-ROBOT : Extension 2m cable to connect the sensor head Model No. : CN-5S-ROBOT : Extension 5m cable to connect the sensor head receiver 17.5 6.5 center Controller 27.4 65.4 22 4.5 13 6.2 47 78 Slot for DIN rail 19.1 27.4 2 35.8 emitter 35 69.6 78 5.8 2-M4 4.2 Cable 5.5m with 1pin connector 14.7 7.7 mm 285
Specifications series Model IEC Class 1 FDA CLASS II Type High power Class 3R Type Measurement range -3-3-3R 3 ±5mm Regular type Class 2 IEC / JIS CLASS FDA Red laser diode, 65nm, max 1m W Light source High power type Class 3R IEC / JIS CLASS a FDA Red laser diode, 65nm, max 5mW Spot size *1 Linearity *2 Resolution *3 Supply voltage Temp drift Laser emission indicator Measurement indicator Protection category Ambient temp / humidity Storage temp / humidity Environmental illuminance Vibration resistance Shock resistance Cable Cable extension Material 3 1 m ±.1% F.S. 1 m Supplied by A-N / P controller ±.1% F.S. / Green = Laser emission Red = In range, closer than center 5% of measurement range to 45% Orange = Within ±5% of the center of the measuring range Green = In range, farther than center 5% of measurement range 55 to 1% Red / Green alternating = Out of measuring range IP67 1 to +45 14 to 113, 35 to 85% RH 2 to +6 4 to 14, 35 to 85% RH Incandescent lamp = Max 3, lux 1 to 55 Hz double amplitude 1.5mm for XYZ 5G 5m/s 2 5cm 19.7 inch cable CN-S-ROBOT 2m, 78 inch, CN-5S-ROBOT 5m, 197 inch Aluminum diecast -85-85-3R 85 ±2mm 7 29 m 3 m -35-35-3R 35 ±1mm 3 7 m 4 m 3 *1 Defined with center strength 1/e 2 13.5%. There may be leak light other than the spot size. The sensor may be affected when there is a highly reflective object close to the detection area. *2 256 times in average using the special amplifier, object: White ceramic. The value is subject to objects. *3 The typical value in the conditions of 256 times in average using the special amplifier, object: White ceramic, distance range: Middle. The value is subject to objects. L-25 Model Measurement range Light source Spot size *1 Linearity *2 Resolution *3 Supply voltage Temp drift Laser emission indicator Measurement indicator Protection category Ambient temp / humidity Storage temp / humidity Environmental illuminance Vibration resistance Shock resistance Cable Cable extension Material L-25 25 ±1mm Class 1 IEC / JIS CLASS FDA Laser, 65nm, max 39 W 25 35 m ±.1% F.S..1 m Supplied by A-LN/LP controller ±.1% F.S. / Green = Laser emission Red = In range, closer than center 5% of measurement range to 45% Orange = Within ±5% of the center of the measuring range Green = In range, farther than center 5% of measurement range 55 to 1% Red / Green alternating = Out of measuring range IP67 1 to +45 14 to 113, 35 to 85% RH 2 to +6, 35 to 85% RH Incandescent lamp = Max 3, lux 1 to 55 Hz double amplitude 1.5mm for XYZ 5G 5m/S 2 5cm 19.7 inch cable CN-S-ROBOT 2m, 78 inch, CN-5S-ROBOT 5m, 197 inch Aluminum diecast *1 Defined with center strength 1/e 2 13.5%. There may be leak light other than the spot size. The sensor may be affected when there is a highly reflective object close to the detection area. *2 256 times in average using the special amplifier, object: evaporated aluminum mirror. The value is subject to objects. *3 The typical value in the conditions of 256 times in average using the special amplifier, object: White ceramic, distance range: Middle. The value is subject to objects. 286
3 Controller Model A-N / -LN NPN output type A-P / -LP PNP output type Number of heads Sampling period Supply voltage Max.2 pcs 1 s 12 24VDC ±1% Power consumption Temp drift 27mA / 24VDC When connected with 2 sensor heads. Including analog current output ±.1% F.S. / Analog output ANG (V) [A] [B] ANG (ma) [A] [B] Voltage output ±5V / F.S. Current output 4 to 2mA / F.S. A Alarm output ALM A,ALM B NPN open collector PNP open collector Max. 1mA / 24VDC residual voltage Max. 1.8V Turns when the sensor head fails in measurement. Control output JDGE 1 to 5 NPN open collector Max. 1mA / 24VDC residual voltage Max. 1.8V PNP open collector HI / LO setting and Hysteresis setting are available for each output. Bank input Hold input BANK to 2 HOLD A, HOLD B, when connected to GND 8 banks selectable when connected to GND when connected to 12 24VDC when connected to 12 24VDC HOLD RST Laser off or measurement value holding selectable in the menu Zero reset input ZERO A, ZERO B when connected to GND when connected to 12 24VDC Zero reset of head A measurement value / Head B measurement value / Calculation value is available. Optional features Cut-off frequency Output control Hysteresis Display type Protection category Ambient temp / humidity Storange temp / humidity Vibration resistance Shock resistance Material Weight LCD display IP2 1 to 45 Non-condensing / 35 to 85% RH 2 to 6 / 35 to 85% RH 2G 196m/s 2 24g including connection terminals 287
Linearity Typical example data series : by material Model No. : -3 / -3-3R.3.2.1 -.1 -.2 -.3 25 26 27 28 29 3 31 32 33 34 35 Model No. : -85 / -85-3R.3.2.1 -.1 -.2 -.3 65 7 75 8 85 9 95 1 15 3 Model No. : -35 / -35-3R.3.2.1 -.1 -.2 -.3 25 27 29 31 33 35 37 39 41 43 45 White ceramic Aluminum Gray ceramic Black rubber L-25 : by angle.4.3.2.1 -.1 -.2 -.3 ± (Typical) +.2 (Typical).4.3 -.4 -.4 24 24.2 24.4 24.6 24.8 25 25.2 25.4 25.6 25.8 26 24 24.2 24.4 24.6 24.8 25 25.2 25.4 25.6 25.8 26.2.1 -.1 -.2 -.3.4.3.2.1 -.1 -.2 -.3 ±.2 (Typical) -.4 24 24.2 24.4 24.6 24.8 25 25.2 25.4 25.6 25.8 26.4.3.2.1 -.1 -.2 -.3 -.2 (Typical) -.4 24 24.2 24.4 24.6 24.8 25 25.2 25.4 25.6 25.8 26 Mirror(SENS=MIN) Glass(SENS=8) 288
Spot size series Model No. : -3 / -3-3R 27 1 27 33 ( m) Model No. : -85 / -85-3R 5 29 5 1 ( m) 3 6 3 6 6 12 7 12 3 25 3 35 1 65 85 15 1 Model No. : -35 / -35-3R 1.2.7 1.2 4.5 (mm) L-25 12 35 1 ( m).65.3.65 3 85 25 7 25 35 45 1 24 25 26 Interference area series Model No. : -3/-3-3R Model No. : -85/-85-3R 1 9 3 3.5 2 1 7 2 ±1 15 6 2 24 36 62 18 Model No. : -35/-35-3R L-25 17.5 3 32 4 25 6 2 35 45 6 mm 289
Input / Output diagrams NPN model bank input Hold input Zero reset input 12-24VDC NPN model control output Alarm output NPN output 3 Internal circuit NPN input Internal circuit GND GND PNP model bank input Hold input Zero reset input NPN model control output Alarm output 12-24VDC PNP input Internal circuit Internal circuit 12-24VDC PNP output Analog output (A/B) 12-24VDC Internal circuit Current output Voltage output GND 29