Optional connector of indoor P.C.Board

Similar documents
Energy Conservational. External Contact Interface Module. Example

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

13. Before making a service call Trip information and remedies

Guidelines to Using a Three Phase Voltage Monitor

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual

CAUTION All safety information must be followed as provided in Service Manual

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER

CAUTION All safety information must be followed as provided in Service Manual

INSTALLATION & OPERATION MANUAL

SPECIFICATIONS Digital Indicator 1. General

CAUTION All safety information must be followed as provided in Service Manual

Blue Point Engineering

ERCD. Features ERCD. Main functions P Supports 4 operating methods including pulse train, programming, point trace, online instructions

AEROCONNECT 1B NA C Control manual

Integrations GW Programming manual

Smartzone LCD TOUCHPAD USER GUIDE.

WHEN A PLC IS TOO MUCH, AND SPACE FOR

Blue Point Engineering

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

GSM Repeater Systems & Accessories

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A

DESIGN & TECHNICAL MANUAL

SmartZone-2 & SmartZone-4

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Product Data Sheet RER225-63/18/2TDO- 406

BULLETIN # B

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

Product Data Sheet RER190-39/14/2TDMO

CONTROL MANUAL. Dry-Pic 09PE - 09VE

Fan Coil Actuator FCA 2

CROSS Chassis from 160 A to 450 A

COMPACT CASSETTE TYPE AIR CONDITIONER

Product Data Sheet RER220-43/18/2TDMO

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

Instruction. Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900. ICAD 1200 Fig. 2. Fig. 4

vacon 100 flow ac drives application manual

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

RS232 CONTROLLER/MONITOR

ET-3888 True RMS Clamp Meter. User Manual

Device connection and commissioning can only be carried out by qualified professionals. Always make the connections while the power is switched off.

DIDO controller. Mitsubishi Electric Air Conditioner Network System PAC-YG66DCA. Table of Contents. Installation/Instruction Manual

n FRONT PANEL CONFIGURATIONS

VT8300 Series Installation Guide 24 Vac Low Voltage

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

HUMIDITY/TEMP. CONTROLLER/MONITOR

LC-RF, LC-IR, LC-PC PRODUCT OFFERING. Type. Project LED RGB CONTROLLER SOLUTION GUIDE LC SERIES. Catalog No.

Electric Motor Actuator with a built in Microcomputer

TLC3-BCR-U Series Thermostat

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

RT-21 Az-El Controller Manual addendum to RT-21 - August 5, 2014

RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

Flowmetering System Controller KMA4000 / PLU4000 Operating instructions

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

Product Data Sheet 3252J/2H3PU

SHC-721A. Another Eye Guarding the World. Low Light, WDR, Day & Night Color Camera. SSNR

LONG RANGE REMOTE RECEIVER WITH TRANSMITTER FOR BUNGALOWS AND BANKS MODEL KE - 2 L R

R PROFLAME Instruction Book Collection

Radio Control Installation and Operating Instructions System 4

JPQ2 PULSE ACCUMULATOR

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

Static Eliminator Blowers

AM

For Air Conditioning Systems

Obstruction Lighting Troubleshooting Manual

Data Acquisition Modules/ Distributed IO Modules

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Owner s Manual BL

Power Regenerative Converter, THYFREC CV240S

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Electric Motor Actuator with a built in Microcomputer

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

E-BUS Digital Room Sensor Technical Guide

Installation & User Manual Radio Remote RCS-10E

STRATUS CONTROLLER MANUAL September 14, 2015

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Product Data Sheet 3254 J/2H3P

NX Series Inverters. HVAC Pocket Programming Guide

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

Driver specifications Motor Specifications P.57

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5

Printing Humidity/Temperature Meter

USB-TC Instructions. Description

The importance of control

Digital Room Sensor Technical Guide

Contactor-less Magnetic Brake Controller

Product Data Sheet 8214 J/2H4P

Transcription:

01Aug06 Optional connector of indoor P.C.Board DI, SDI VRF 1

Outline Function Connector Pin No. Outline Model name Fan output Option output HA terminal Option error input Demand input Outside error input CN32 CN60 CN61 CN70 CN73 1,2 1,2,3,4,5,6 Ventilation control from RC Operation status signal output (cooling, heating, fan, defrost, thermo-on) TCB-KBCN32VEE TCB-KBCN60OPE 1,2,3,4,5,6 TCB-KBCN61HAE 1,2 1,2 CN80 1,2,3 External ON/OFF, operation output, alarm output Alarm display Forced thermo-off control Alarm input (L30) & forced OFF TCB-KBCN70OAE TCB-KBCN73DEE TCB-KBCN80EXE 2

VRF DI SDI Applicable indoor units Connector TCB-KB CN32VEE CN60OPE CN61HAE CN70OAE CN73DEE CN80EXE 4-way MMU-AP***1H OK OK OK OK OK OK 60 x 60 MMU-AP***1MH OK OK OK OK OK OK 2-way MMU-AP***1WH OK OK OK OK OK OK MMU-AP***1YH OK OK OK OK OK OK 1-way MMU-AP***1SH OK OK OK OK OK OK MMD-AP***2SH OK OK OK OK OK OK Duct MMD-AP***1BH OK OK OK OK OK OK Hi static MMD-AP***1H OK OK OK OK OK OK Slim duct MMD-AP***1SPH OK OK OK OK OK OK Ceiling MMC-AP***1H OK OK OK OK OK OK Hi wall MMK-AP***1H OK OK OK OK OK OK MMK-AP***2H OK OK OK - OK OK MML-AP***1H OK OK OK OK OK OK Floor stand MML-AP***1BH OK OK OK OK OK OK MMF-AP***1H OK OK OK OK OK OK 4-way RAV-SM***UT-E OK OK OK OK OK OK RAV-SP***UT-E OK OK OK OK OK OK 60 x 60 RAV-SM***MUT-E OK OK OK OK OK OK Duct RAV-SM***BT-E OK OK OK OK OK OK Ceiling RAV-SM***CT-E OK OK OK OK OK OK Flexi RAV-SM***XT-E - - - - - - Hi wall RAV-SM***0KRT-E - - - - - - RAV-SM***1/2KRT-E OK OK OK - OK OK 3

Specification of relay Indoor unit Specification of Relay DC motor type MMU-AP***1H MMU-AP***1MH MMU-AP***2SH MMD-AP***1BH MMD-AP***1SPH MMK-AP***2H MMC-AP***1H RAV-SM/SP***UT-E RAV-SM***MUT-E RAV-SM***CT-E RAV-SM***1BT-E RAV-SM**1/2KRT-E Corresponds up to a relay in which rated current of the operation coil is approx, 75mA 4

Indoor unit Specification of relay Specification of Relay AC motor type MMU-AP***1WH MMU-AP***1YH MMU-AP***1SH MMD-AP***1H MML-AP***1H MML-AP***1BH MMF-AP***1H MMK-AP***1H RAV-SM***0BT-E Flexi type (XT type) is not available for application Corresponds up to a relay in which rated current of the operation coil is approx, 16mA. (Does not correspond to a terminal block type relay on the market.) 5

1 DC12V (Common) 2 Fan output (Open collector) CN32 (TCB-KBCN32VEE) -Shipment setup (DN31 =0000) ON with indoor unit ON & OFF with indoor unit OFF are linked -Ventilation control (DN31 =0001) Individual ON/OFF control from ventilation button of remote controller RC ON Ventilation ON (If already ON, ON remains) RC OFF Ventilation OFF (If already OFF, OFF remains) 1 2 White Red Blue 6

CN32 (Ventilation control) Indoor P.C. Board COM (DC12V) Fan Output CN32 1 1 2 2 Max. 2m Relay (DC12V) Ventilation control from remote controller DN31 = 0000 CN32 output links with indoor unit ON/OFF No ventilation sign on LCD DN31 = 0001 CN32 output links with indoor unit ON/OFF Individual ON/OFF by VENT button Ventilation sign on LCD 7

1 DC12V 2 (COM) Defrost output CN60 (TCB-KBCN60OPE) Common for Pin.2 to 6 ON signal when outdoor unit is in defrosting 3 4 5 6 (Open collector) Thermo ON output (Open collector) Cooling output (Open collector) Heating output (Open collector) Fan output (Open collector) (when receiving defrost signal from outdoor unit) ON signal when indoor unit is thermo-on ON when operation mode is cooling (Cooling, Dry, Cooling in Auto mode) ON when operation mode is heating (Heating, Heating in Auto mode) ON when indoor fan is ON (ex. Interlock cabling) 8

CN60 (TCB-KBCN60OPE) White 1 2 3 4 5 6 Red Blue Orange Yellow Brown Black 9

CN60 (Defrost output) Indoor P.C. Board Max. 2m CN60 COM (DC12V) 1 1 Defrost output 2 2 3 3 4 4 5 5 6 6 Relay (DC12V) ON signal output when outdoor unit is in defrosting (when receiving defrost signal from outdoor unit) 10

CN60 (Thermo-ON output) Indoor P.C. Board Max. 2m CN60 COM (DC12V) 1 1 2 2 3 3 4 4 5 5 6 6 Thermo-ON output Relay (DC12V) ON signal when Thermo-ON 11

CN60 (Cooling output) Indoor P.C. Board CN60 Max. 2m COM (DC12V) 1 1 2 2 3 3 Cooling output 4 4 5 5 6 6 Signal ON when cooling mode Relay (DC12V) (Cooling, Dry, cooling in Auto) RC=ON & Mode = Cooling -Signal is still ON during thermo-off - Signal is OFF during alarm status 12

CN60 (Heating output) Indoor P.C. Board Max. 2m CN60 COM (DC12V) 1 1 2 2 3 3 4 4 Heating output 5 5 6 6 13 Relay (DC12V) Signal ON when heating mode (Heating, Heating in Auto) RC=ON & Mode = Heating - Signal is still ON during thermo-off, - Signal is OFF during alarm status

CN60 (Fan output) Indoor P.C. Board Max. 2m CN60 COM (DC12V) 1 1 2 2 3 3 4 4 5 5 Fan output 6 6 Relay (DC12V) Signal ON when indoor fan is running ex. Interlock cabling (for booster fan, etc) 14

CN60 (Fan output) Signal ON when indoor fan is running - Interlock cabling (with booster fan for fresh air intake, etc) 15

CN61 (TCB-KBCN61HAE) 1 ON/OFF input External ON/OFF control 2 3 4 5 6 0V (Common for Pin,1,3) ON/OFF prohibition input Operation output (Open collector) DC 12V (Common for Pin 4,6) Alarm output (Open collector) (DN code 2E, J01) Remote controller ON/OFF prohibition is permitted / prohibited by input signal ON signal during remote controller ON & No alarm ON signal during alarm output 16

CN61 (TCB-KBCN61HAE) Yellow 1 2 3 4 5 6 Blue White Orange Yellow Red Brown 17

CN61 (External ON/OFF) Indoor P.C. Board ON/OFF input COM (0V) CN61 1 1 2 2 3 3 4 4 5 5 6 6 Max. 2m Power supply 18

CN61 (External ON/OFF)--- ---Logic DN 2E J01 Action 0000 (At shipment) Connect Cut Pulse input Static input ON Pulse width 200 to 300ms Pulse interval 200ms or more ON OFF OFF Connect Leaving ON prevention control Prohibition reset OFF & Prohibition 0001 Cut No action Heating = Highest set point Cool/Dry = Lowest set point Auto/fan = Neglect 19

CN61 (Prohibition input) Indoor P.C. Board Max. 2m CN61 COM (0V) Prohibition input 1 1 2 2 3 3 4 4 5 5 6 6 When signal ON, Power supply Relay Remote controller ON/OFF is prohibited Central controller become Central 1 mode. 20

Reference CN61 (Prohibition input) Central controller prohibition mode CN61 Prohibition Central ON/OFF Mode Set point 1 X 2 X X X 3 X X 4 X This prohibition can be released from central remote controller 21

CN61 (Operation output) Indoor P.C. Board Max. 2m CN61 Operation output COM (DC12V) 1 1 2 2 3 3 4 4 5 5 6 6 Signal ON during operation Relay (DC12V) (Operation = Remote controller ON & No alarm) (Note)Individual signal output in group control is available. 22 If follower indoor unit generates alarm, signal become OFF in this indoor unit only.

CN61 (Alarm output) Indoor P.C. Board Max. 2m COM (DC12V) Alarm output CN61 1 1 2 2 3 3 4 4 5 5 6 6 Relay (DC12V) Alarm : both Indoor / Outdoor alarm 23

Caution CN70 (TCB-KBCN70OAE) No CN70 connector in RAV-SM**KRT/ MMK-AP**2H 1 Error input Default : DN2A =0002 (at shipment) 2 OV (COM) DN2A=0001 (External error input) When signal is input, error symbol is displayed. (Indoor unit does not stop) White 1 Blue 2 White 24

CN70 (Option error input) Indoor P.C. Board Max. 2m Error input COM (0V) CN70 1 1 2 2 Relay Relay coil signal DN 2A = 0001 (at shipment 0002) When signal is input, remote controller displays the symbol 25 (This symbol is displayed even when RC is off.) Air conditioner does not stop.

CN73 (TCB-KBCN73DEE) 1 Demand input Indoor unit forced thermo-off 2 OV (COM) Red 1 Blue 2 White 26

CN73 (Demand input) Indoor P.C. Board Max. 2m Demand input COM (0V) CN73 1 1 2 2 Relay Relay coil signal When signal is input, indoor unit is in Thermo-off status forcibly 27

CN80 (TCB-KBCN80EXE) 1 DC12V Common for Pin.3 2 3 - (COM) Outside error input After signal is input continuously, 3 sec. Forced thermo-off 1 min. Error code L30 (Interlock from outside) and stop the operation (this unit only) 1 2 3 Green Red Blue 28

CN80 (Outside error input) Indoor P.C. Board Max. 2m COM (DC12V) Outside error input CN80 1 1 2 2 3 3 Relay (DC12V) After signal is input continuously, 3 sec. later -- > Forced thermo-off 1 min. later -- > Error code L30 (Indoor unit is locked) 29 (Interlock from outside)

30 End