MAGTROL. LMU 112 and LMU 117 Load Monitoring Units. LMU 112 / LMU 117 Data Sheet LMU 112 FEATURES LMU 117 FEATURES DESCRIPTION SYSTEM CONFIGURATION

Similar documents
MAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION

MAGTROL. LMU Series Load Monitoring Units. LMU Data Sheet. Description. Features

Load Monitoring Units. LMU 212 and LMU 217. User s manual

Load Monitoring Unit LMU 216. User s manual

LOAD MONITORING UNIT LMU 116 VERSIONS 02X AND 02XC

LOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS

TSC 401 Torque/Speed Conditioner

MAGTROL. KLB Wedge socket. KLB/KLE/KLU Data Sheet SYSTEM CONFIGURATION

SIGNAL CONVERTER I/V AND I/I CST 113

LB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS.

MAGTROL. DI Series Displacement Transducers. DI Data Sheet. Features

LS 120 and ILS 730. Air-gap measuring system LS 120 transducer and ILS 730 signal conditioner

IPC 704. Signal Conditioner Type IPC 704. U / I output DATA SHEET FEATURES

WS12EX Position Sensor with Analog output Dust explosion-proof

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SE 120. Piezoresistive accelerometer

Economical Digital Indicators For Process and Electrical Measurement

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

DMS Insert Module MSR 282

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Adjustable Digital Process Instrument MDK480

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

DP2000 ORDERING GUIDE To Order MODEL NO.

MODEL AT-10 ANALOG TRANSMITTER

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

IPC 704. Signal conditioner FEATURES. For CA piezoelectric accelerometers and CP dynamic pressure transducers

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Electromagnetic flowmeters and switches DWM 1000/2000

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

FC Series Signal Conditioners

MAGTROL. KLB Wedge socket. KLB/KLE/KLU Data Sheet SYSTEM CONFIGURATION

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

CAN-IO Custom IO remote module

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

20 General technical data XI/ON

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Differential Charge Amplifier

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Type CP-S, CP-C & CP-A Switch mode

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

CE620. Piezoelectric accelerometer with integrated electronics. IECEx

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

CMC 256plus - protection relay test set and universal calibrator

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

P1-04ADL-2 Analog Input

Switching power supplies CP range, Linear power supplies CP-L range. Content

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

ISOMETER IRDH575. Approvals

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

SINEAX B 811 Power Pack with additional Functions

Power Supplies 3. SDN-C Compact DIN Rail Series

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

TQ 402 & TQ 412 / EA 402 / Proximity System. 三協インタナショナル株式会社東京 :Tel: 大阪 :Tel: 名古屋 :Tel: FEATURES

Signal Conditioning Amplifier

08/07/2015

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

DRG-SC Series Signal Conditioners

Tel: (949) Fax: (949) IAA100 Product Manual

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Holiday Detector mod. 184/45KV

Analog signal converters CC range

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

CONTA-ELECTRONICS. Converter Units

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Model 140 Inline Amplifier

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Strain gauge amplifier

SY038 UNIVERSAL LOAD CELL AMPLIFIER

Pressure transmitter AKS 32 and AKS 33

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Zelio Control Measurement Relays

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Transcription:

Data Sheet LMU 112 and LMU 117 Load Monitoring Units LMU 112 FEATURES For Use with Full-bridge Strain Gauge Transducers (Sensitivity 0.5 to 2 mv/v) Voltage Input for Different Charge Summation 2 Level Detectors with Relay Output Contacts 0 to 20 ma DC Current Output ±10 V Voltage Output Provides Continuous Detection of Signal Line Failure and Short Circuits Compatible to CE Standards IP 65 Aluminium Housing LMU 117 FEATURES Composed of Two LMU 112 Units Same Features as the LMU 112 LMU 117 LMU 112 DESCRIPTION The Magtrol LMU Load Monitoring Unit is specially designed for strain gauge transducer applications. It is flexible and fully configurable due to DIP-switches and jumpers which allow the unit to be easily installed no solder connections are required. The LMU 112 contains 1 full-bridge strain gauge transducer input, 1 voltage input, 2 level detectors (output contacts), 1 current output, 1 voltage output and 2 OK self-test signals for monitoring the correct operation while running several LMU units simultaneously. The level detectors and the outputs can be dedicated either to the full-bridge input, to the voltage input or to the sum of both The LMU 112/LMU 117 is used with Magtrol Load Measuring Pins which measure load and force and provide overload protection. Magtrol also offers a wide range of Load- Force-Weight Transducers in various executions and accuracy classes and our Digital Process Monitors/Signal Conditioners measure and display load, force and weight from signals generated by strain gauge transducers. (see Application Selection at bottom of page 2). A built-in self-test system detects any short circuits or signal line failures, thus allowing the system to be used in applications where safety is important. If a problem is detected, both relays are deactivated and the output voltage (respective current) changes to >10 VDC (>20 ma). The LMU is fully compatible with European Community (CE) standards. Its IP 65 aluminium housing allows the system to be used in harsh environments. Using SMD (surface mounted device) technology, the LMU allows the maximum performance/price ratio for strain gauge transducer monitoring. SYSTEM CONFIGURATION Strain Gauge Transducer Voltage Input ±10 V "OK" Input (OK I/P) Power Supply 115 / 230 VAC (50 to 60 Hz) 20 to 32 VDC LMU 112/ LMU 117 Output Contacts of Relay RE1 Output Contacts of Relay RE2 "OK" Output (OK O/P) Current Output 0 to 20 ma Voltage Output ±10 V 1 www.magtrol.com

Specifications * Refer to NOTE on following page. 2 INPUT CHARACTERISTICS Power Supply Voltage Maximum Current Bridge Signal Supply Voltage Max. Possible Current Sensitivity Max. Dynamic Component of Bridge Signal Max. Common Mode Voltage on Input 115 VAC/230 VAC (50 60 Hz) or 20 to 32 VDC, jumper selectable Current Fuse Rating 70 ma for 230 VAC 80 mat 150 ma for 115 VAC 160 mat 250 ma for 20 VDC 400 mat 10 VDC 150 ma DC 0.5 to 2 mv/v ±30 mv DC ±10 V Voltage Input for Summation of Another Load Input Impedance Max. Input Signal (dynamic) 200 kω ±10 V Input for Self-Test Feature (OK I/P) Type OUTPUT CHARACTERISTICS Relay Outputs Active if short circuited Number 2 (RE 1; RE 2) Normal State Max. Current per Contact Max. Voltage per Contact Max. Break Power Insulation Voltage Lifetime Contact Resistance Current Output Output Type Nominal Current Range Max. Current Range Max. Load Output Impedance Voltage Output Max. Value Max. Load Output Impedance Normally energized 5 A continuous / break 20 A on startup AC: 250 V rms DC: 350 VDC 100 W or 1000 VA Contact-Contact: 750 V rms Contact-Coil: 1.5 kv rms > 2 10 8 switchings < 20 mω Current generator 0 to 20 ma DC 0 to 25 ma DC < 500 Ω for I max = 20 ma > 50 kω ±10 V FSD 10 kω(ε 1%)[ 2 kω(ε 5%)]* 100 Ω (in series) Output for Self-Test Feature (OK O/P) Type Open collector (short circuit-proof) TRANSFER CHARACTERISTICS Voltage Transfer Ranges ( U I/P / U O/P ) Range 1 2 3 Bridge Sensitivity [mv/v] 0.42 to 0.78 (0.6) 0.7 to 1.3 (1) 1.2 to 2.2 (1.7) Voltage Transfer (gain) 2380 to 1280 (1670) 1428 to 769 (1000) 833 to 455 (588) Adjustment Range ±30% ±30% ±30% Range Selection Zero Adjustment for Measuring Chain Using DIP-switches Coarse adjustment using multiturn potentiometer: equivalent to ± 10 V/output for Range 3 Fine adjustment using multiturn potentiometer: 5% of the coarse adjustment Temperature Drift of Transfer Function 200 ppm/ C Temperature Drift of 0 200 ppm of FSD/ C for range 0.5 mv/v 1 µv/ C Current Transfer Range Sensitivity Range with Multi-turn Potentiometer ± 20% of FSD on U O/P Nominal Current Range 0 to 20 ma DC Max. Current Range 0 to 25 ma DC Zero Adjustment Range ± 5 ma DC for I O/P 5 ma DC Selectable Low-Pass Filter Filter Type Butterworth Filter Order 2nd -3dB Cut-off Frequency Selectable using DIP-switches to 0.3 Hz; 1 Hz; 3 Hz; 10 Hz Transfer Function Between Summing Input/ 1 Voltage Output Level Detectors Number of Detectors 2 (REL1; REL2) -10 to +10 VDC using multi-turn Level Adjustment Range potentiometer (measured on voltage output) Hysteresis 0 or 5% (selectable using DIP- switches) Detection Indication < or > (selectable using DIP-switches) Switching Delay Number of Circuits 2 Delay Adjustment Range 0 to 5 seconds using multi-turn potentiometer Application Selection Selection Det. REL1 Det. REL2 U O/P, I O/P 1 A A A 2 A + B A A + B 3 A A + B A 4 A + B A + B A + B 5 B B B 6 A + B B A + B A = Bridge signal; B = Voltage input

Specifications MECHANICAL CHARACTERISTICS Housing Material Weight Aluminum 2 kg; 4.41 lb Stuffing Glands Number and Type 3 PG 11 Material Nickel-plated brass Terminal Strip MK8 (screw at 45 and Type connection at 45 ) Max. Area of Connecting Wire AWG 20 to 16 Cross-section: 0.5 to 1.5 mm² ( 0.00077 to 0.0023 in²) ENVIRONMENTAL CHARACTERISTICS Operating Temperature -40 C to +80 C Storage Temperature -45 C to +85 C Protection Class IP 65 Vibration and Shock According to IEC 68.2 According to EN-58081-2 EMC (Generic Emission Standard) and EN-58082-2 (Generic Immunity Standard) * NOTE: In order to guarantee a precise calibration, the customer is asked to indicate the impedances of the connected unit together with the order. If this value is unknown, an impedance of 1 MΩ will be used for calibration. The resulting deviation will be in the order of 5% with an impedance of 2 kω or 1% with 10 kω. LMU 112 DIMENSIONS C E D G A B OVERHEAD VIEW P Mounting Screw M6 30 Sealed Diecast Aluminum Box - Protection Class IP 65 Stuffing Glands Ø cable: 5 to 12 mm ( 0.20" to 0.47") J M L Type: P/N: S/N: LMU 112 224-112-000- LOAD MONITORING UNIT K Fribourg Swizterland N SIDE VIEW NOTE: Original dimensions are in Metric units. Dimensions converted to English units have been rounded up to 2 decimal places. mm in A 120 4.72 B 82 3.23 C 220 8.66 D 204 8.03 E 16 0.63 G 20.75 0.82 J 13.4 0.53 K 90 3.54 L 1.5 0.06 M 28 1.10 N 47 1.85 P 40 1.57 LMU 112 ORDERING INFORMATION PART NUMBER DESCRIPTION 224-112-000-021 LMU 112 Load Monitoring Unit standard model with no setup and no calibration 224-112-000-021C LMU 112 Load Monitoring Unit setup and calibration according to the configuration and calibration report PY 7606 (to be filled according to the application) 3

Specifications LMU 117 DESCRIPTION The LMU 117 Load Monitoring Unit is a dual-channel electronic device composed of two LMU 112s assembled in an aluminium housing (the connection between power supplies is factory-made). LMU 117 When using several load monitoring units, the OK feature allows the operation of all units to be monitored using a single OK input or output THE INPUT, OUTPUT, TRANSFER, ENVIRONMENTAL AND MECHANICAL CHARACTERISTICS OF THE LMU 117 ARE IDENTICAL TO THOSE OF THE LMU 112. LMU 117 DIMENSIONS Stuffing Glands (PG 11 max.) Ø cable: 5 to 12 mm ( 0.20" to 0.47") K M UUU UUU H J N N P P P N N FRONT VIEW Mounting Screw M6 30 SIDE VIEW F C E D B A OVERHEAD VIEW Sealed Diecast Aluminum Box - Protection Class IP 65 NOTE: Original dimensions are in Metric units. Dimensions converted to English units have been rounded up to 2 decimal places. mm in A 287 11.30 B 272 10.71 C 190 7.48 D 175 6.89 E 16 0.63 F 218 8.58 H 12 0.47 J 10 0.39 K 90 3.54 M 27 1.06 N 30 1.18 P 35 1.38 LMU112DS-US www 03/03 LMU 117 ORDERING INFORMATION PART NUMBER DESCRIPTION 224-117-000-011 LMU 117 Load Monitoring Unit standard module with no setup and no calibration 224-117-000-011C LMU 117 Load Monitoring Unit setup and calibration according to the configuration and calibration report PY 7606 (to be filed according to the application) Due to the continual development of our products, we reserve the right to modify specifications without forewarning. 4

Configuration and Calibration Report CONFIGURATION AND CALIBRATION REPORT FOR LMU 112 VERS. 02X LMU 112 P/N : 224-112-000-02X S/N : DWG. Nr. : SWITZERLAND PY 7606 5

C E R TIFIC A TI O N www.magtrol.com INC 70 Gardenville Parkway Buffalo, New York 14224 USA Phone: +1 716 668 5555 Fax: +1 716 668 8705 E-mail: magtrol@magtrol.com SA Route de Moncor 4B 1701 Fribourg, Switzerland Phone: +41 (0)26 407 3000 Fax: +41 (0)26 407 3001 E-mail: magtrol@magtrol.ch Subsidiaries in: Germany France Great Britain Worldwide Network of Sales Agents Magtrol SA ISO 9001:2000 certified ISO 9001 SWISS