Nikon E800 Operating Instructions.

Similar documents
Nikon E800 Operating Instructions.

Nikon E800 Microscope. Operating Instructions

EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY

Using the Nikon TE2000 Inverted Microscope

Characterization Microscope Nikon LV150

Zeiss Axio Imager.A1 manual

Zeiss Axioskop II. The AIF's "routine" light microscope. (Installed 8/24/04)AxioCam installed July 11th 2005

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

Motorized Axio Observer Start-up instructions

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

Zeiss AxioImager.Z2 Brightfield Protocol

Guide to Confocal 5. Starting session

DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

Nikon TE300 Eclipse Wide-Field Microscope

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Zeiss LSM 880 Protocol

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

Brightfield Microscopy and Image Acquisition on Spotcam1. by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer

Imaging Introduction. September 24, 2010

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

INSTRUCTIONS FOR COURSE WORK 4 (AxioVert) Instructor: Anne Vaahtokari (MIU) 1. Purpose of the work

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

Olympus IX71 Microscope and DP71 Camera Instructions

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

Instructions for Making On-Line Reservations for Microscopes in NB11-204

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Widefield 1. Switching on

Leica SP8 TCS Users Manual

Olympus Time-lapse Microscope Basic operation

Olympus xcellence Software - basic user guide

b. Turn the power switch and key to on position for blue laser.

Indian Institute of technology Madras Presents NPTEL NATIONAL PROGRAMME ON TECHNOLOGY ENHANCED LEARNING

Things to check before start-up.

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

personal DELTAVISION (pdv)

Very short introduction to light microscopy and digital imaging

AxioVision 4.5 Brightfield Image Capture Procedure

Microscope ECLIPSE 80i Instructions <Reference>

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.


OMM300. Inverted Metallurgical Microscope

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Reichert Univar Manual

MICROSCOPY FOR THE DEVELOPMENTAL BIOLOGY STUDENT...

User manual for Nikon Elements software

Zeiss LSM 780 Protocol

Brief manual how to start and close the Leica sp2 Confocal. (TCS SP2 AOBS system mounted on a DM IRE2)

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Quick Start Guide. Leica SP5 X

MetaMorph Imaging Handbook Update 6/4/13

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Fluorescence Imaging with Olympus IX81 Microscope Last updated December 1 st, 2017

Operating Instructions for Zeiss LSM 510

Zeiss AxioObserver with ApoTome

STEINDORFF METALLURGICAL MICROSCOPE. NYMCS-620 Instruction Manual

LSM 510 META in Chang Gung University

Marine Invertebrate Zoology Microscope Introduction

Leica SP8 TCS Users Manual

2/4/15. Brightfield Microscopy! It s all about Magnification..! or is it?!

Zeiss Deconvolution Microscope: A Quick Guide

INTRODUCTION TO OPTICAL MICROSCOPY

ZEISS LSM510META confocal manual

BRIGHTFIELD Olympus TH4-200 Olympus TH4-200 Please keep objectives off touching to avoid their loosening or damage.

Simplified Instructions: Zeiss Brightfield Microscope S1000

Leica DB LB Research microscope and Studo Lite Imaging software

SWIFT SERIES M2252DGL MICROSCOPE

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Components of the Microscope

Microscope Confocal LSM510 META

Practical Light Microscopy

Leica SPEII confocal microscope. Short Manual

Nasmyth Ultraview Vox User Protocol

Biological Microscope Manual

Manual for BMS E1 eplan series, compound microscope

CMI STANDARD OPERATING PROCEDURE. Fluoview 300 laser scanning confocal microscope

Nikon SIM-E & A1-R System

BASICS IN BIOIMAGING AND OPTICS PLATFORM EPFL SV PTBIOP LIGHT MICROSCOPY

Zoom Stereo Microscope NYMCS-360 Instruction Manual

Industrial Microscope ECLIPSE LV100DA Instructions

Last updated: May 2014 Y.DeGraaf

The following units are required for an ApoTome imaging workstation:

Leica TCS SL Confocal Training. Neuroscience Imaging Core Staff. Core Director. Facility Manager

TE2000 T-FL Epi-Fl Attachment T-FL-E Motorized Epi-Fl Attachment Instructions

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

QUICKSTART GUIDE: WIDEFIELD WF3 Zeiss Cell Observer Live Cell Imaging System (SAF, ROOM 409) Imperial College London

Everest System / Slidebook Operating Procedures

Leica DMI 4000 tutorial

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

TRAINING MANUAL. Olympus FV1000

Leica Confocal - 2. Instructions for Leica SP2 Confocal Equipped with Visible Laser Lines

Transcription:

Nikon E800 Operating Instructions. You can request electronic copies of this manual by contacting lshats@jhsph.edu Copies are also available on the JHU MMI Department web site. Please send your comments and/or suggestions to lshats@jhsph.edu

. Prepared by JHU MMI Dep. 10/15/2009

Table of contents: 1. The Nikon E800 Microscope 3 2a. Turning ON the system 5 2b. Turning OFF the system 5 3. Selecting the light path 6 4. Operating in transmitted light mode 7 5. Adjusting the Microscope for Koehler illumination 10 6. Setting the microscope for DIC 12 7. Setting the microscope for fluorescence 14 8. Starting imaging software (Metamorph) 16 9. Turning OFF the system 17 о

Nikon E800 Operating Instructions. 1. The Nikon E800 Microscope. The Nikon E800 is a fixed-stage upright microscope configured to image in transmitted light, DIC, and epi-fluorescence modes. The Nikon is equipped with the following objectives: Mode 10X0.45 20X0.75 40X0.95 60X1.4 100X1.3 Epi-fluorescence * * * * * Differential Interference Contrast-. * * * Phase Contrast * * Brightfield * * * * * Oil Immersion: The 60xs and l00x objectives are the only oil immersion lenseson this-microscope. The very short focal lengths of these lenses create a real possibility of breaking the specimen slide while close focusing. The lenses do have a retractable front end which should protect the slide from light contact with the lens, but slides are broken. Pieces of broken slide glass, with their biological contents, should be placed in the "sharps" container on the bench. They should not be left on the bench where they might not be seen, especially if the pieces are unlabeled. The inverted microscope does not put the specimen under stress if there is contact between the specimen and the objective while focusing, so there is no sharps receptacle with that microscope. The condenser is: C-CU with 0.9 N.A. dry lenses (swing-out) and contains the following inserts: A (bright field) /DIC L/ DIC M/ DIC H/0/0/0. DIC lens prisms are inserted above each individual objective lens. The Nikon also has a 5-position filter cube slider with (generally) the following filter cubes (see attached spectra in the appendix): 1. empty (VIS) 2. UV2E/C DAPI 340-380/400/435-485 3. FITC, HYQ 460-500/505/510-560 4. TRITC, HTQ 530-560/575/590-650 5. Triple BP (UV/D/F/TR) In addition, we have the two following cubes: Cy5, HYQ TexRed, HQ 590-650/660/660-740 530-590/595/610-690 These cubes can be interchanged on slider position #5 (ask the staff) 3

Camera 4

2.1 Power ON Mercury (Hg) arc lamp (if using fluorescence). 2.2 Power ON microscope. 2.3 Power ON HQ high-resolution monochrome camera (if necessary) 2b. Turn the system OFF. IMPORTANT: IF YOU ARE THE LAST USER, ESPECIALLY AFTER HOURS OR DURING WEEK-ENDS, ALWAYS REMEMBER TO POWER SYSTEM OFF WHEN DONE: 1. POWER OFF ALL SWITCHES (EXCEPT COMPUTER) 2. CLEAN UP IMMERSION OIL FROM OBJECTIVES USING LENS TISSUE (FOLD ONE OR TWO SHEETS OF TISSUE IN TWO ALONG THEIR LENGTH, HOLD BY THE EDGES, AND GENTLY WIPE OBJECTIVE; REPEAT WITH NEW TISSUE IF NECESSARY). 3. MAKE SURE ALL LAMPS AND CAMERAS ARE OFF BEFORE YOU COVER MICROSCOPE. 5

3. Selecting the light path. Two sliders on the right side of the eyepiece select the light path. Lower Slider (2) IN: Coolsnap HQ High Resolution Monochrome CCD Camera Lower Slider (2) OUT: Coolsnap cf Color CCD Camera/Binocular viewing (eyepiece) Upper Slider (1) IN: Eyepiece Upper Slider (1) OUT: Coolsnap cf color CCD Slider 3: Infra-Red protection for CCD camera (leave in the engaged (IN) position). 6

4. Operating in transmitted light mode. 3.1 Use switch on the front base of microscope to select transmitted light (DIA). 3.2 If Hg lamp is ON, engage Hg lamp block (pull slider OUT) to block Hg lamp illumination 3.3 Select blank filter cube (DIA-ILL) 7

3.4. Choose objective. Apply a SMALL drop of immersion oil to sample if using immersion lens. Inspect objective markings and chart on the wall to make sure you do not apply immersion oil to a dry lens. 3.5. Focus on sample. 3.6. Adjust illumination intensity with power dial on left side of microscope 3.7. Engage filters for transmitted illumination if required (e.g. neutral density to attenuate light). Push lever down to engage filter. 8

3.8 Remove polarizer and analyzer from the light path. (swing polarizer (1) out; pull analyzer (2) out). 3.9. Set Condenser turret to position A (for normal transmitted light) 9

5. Adjusting the microscope for Koehler illumination. Typically, the microscope will be properly adjusted. The only adjustments you need to do is to open the field diaphragm to just enclose the field of view for your objective, and adjust the condenser aperture. The full procedure is described below. 5.1 Stop down (close) field diaphragm by rotating dial on right side of microscope base 5.2 Focus field diaphragm by moving condenser UP or DOWN (1) 5.3 Center field diaphragm using condenser centering screws (2) 5.4. Open field diaphragm barely wider than the field of view (see Fig 4.1) 10

5.5 Open condenser aperture diaphragm to about 75% of the objective back aperture. You can examine the objective back aperture by removing one eyepiece and looking down the tube. As an approximation, the condenser aperture should be set to minimum for 10x objective and to max for 100x objective: 10x: setting ~2 20x ~5 <open-close> 40x ~7 O o 60x ~9 10 0 100x ~9 11

6. Adjusting the microscope for DIC. Typically, the microscope will be properly adjusted. Normally, you only need to select the condenser prism matching your objective, and engage the polarizer and analyzer. The whole procedure is described below. 6.1 Engage Polarizer (swing over light path; left) and Analyzer (slide IN; right) 6.2 Select position A on condenser turret (no DIC prism engaged) 12

6.3 Disengage objective prism by pulling prism slider OUT (without removing completely; the DIC objective prisms are the little sliders located just above each objective). Note: make sure to disengage the prism directly above the objective in use (in the image below, the prism shown belongs to an objective that is NOT in use). 6.4 Verify that field is dark. Rotate polarizer for minimum transmission (normally when set to -o-) 6.5 engage objective prism (push IN) 6.6 select matching condenser prism (H, L or M; read DIC label on objective or use Table in section 1) 6.7 for fine adjustments, rotate analyzer dial (make sure to unlock by rotating screw on top) 13

7. Setting the Microscope for Fluorescence. 7.1 Disengage Analyzer (1; pull OUT) Note: the polarizer is not in the epi-illumination light path, and therefore does not affect its quality. 7.2 Pull epi-illumination shutter OUT to block light (2). 7.3 select EPI setting on front base dial (will work on OFF too) 7.4 select fluorescence filter cube by moving slider 14

Filter positions (from left to right). [Note: Positions 1-4 are generally fixed. Position 5 may be occupied by a different filter (e.g. Texas Red or Cy5)]: Position 1: blank (transmitted light) Position 2: DAPI Position 3: FITC Position 4: TRITC (Rhodamine) Position 5: Triple DAPI/FITC/TexasRed 7.5. Open fluorescence illumination shutter by pushing IN 7.6. Select the smallest convenient illumination field aperture using the epifluorescence field diaphragm (1). Center if necessary using the two centering screws (2). 7.7 Always pull shutter OUT when not imaging or viewing to minimize photo bleaching of your sample. 15

8. Starting Imaging Software (Metamorph). 8.1 Verify that the desired camera is ON (typically, HQ for fluorescence, cf for transmitted light); See section 2. 8.2 Double-click on the camera icon on desktop. This will launch Metamorph acquisition software. 8.3 If one camera is not ON, will give error message: "camera not found, do you want to try again?" Answer NO 8.4 Adjust light path for the appropriate camera: Lower Slider (1) IN: Coolsnap HQ High Resolution Monochrome CCD Camera Lower Slider (1) OUT: Coolsnap cf Color CCD Camera/Binocular viewing (eyepiece) Upper Slider (2) IN: Eyepiece Upper Slider (2) OUT: Coolsnap cf color CCD 8.5 Click on "Acquire Image". Will open "acquire" dialog window. On "acquire" window: use "show live" to show live image for centering and focusing your sample use acquire to acquire single exposure. Adjust exposure and collect Image. 16

Use "Save as" to save the image to your local folder. Move later to your fred account. Use control buttons on left of window to display image histogram, select display colors, and select magnification. Notes: To collect multiple color planes (e.g. in fluorescence) with Metamorph, you need to acquire a grayscale image for each channel, by manually selecting th appropriate fluorescence filters. Once you have the desired images, you can combine them into an RGB color image with Metamorph, or other imaging software. Metamorph can collect time-lapse images into a multi-layered image file (stack). The stack can be saved as an AVI or QT movie. Metamorph does not record the type of objective used. For distance measurements on your image, you need to record that information (e.g. by adding it as a file info ). Metamorph can measure distances if you have the proper calibration file for the objective you used. 9. Turning OFF the system. IMPORTANT: IF YOU ARE THE LAST USER, ESPECIALLY AFTER HOURS OR DURING WEEK-ENDS, ALWAYS REMEMBER TO POWER SYSTEM OFF WHEN DONE: 9.1. POWER OFF ALL SWITCHES (EXCEPT COMPUTER) 9.2. CLEAN UP IMMERSION OIL FROM OBJECTIVES USING LENS TISSUE (FOLD ONE OR TWO SHEETS OF TISSUE IN TWO ALONG THEIR LENGTH, HOLD BY THE EDGES, AND GENTLY WIPE OBJECTIVE; REPEAT WITH NEW TISSUE IF NECESSARY). 9.3. MAKE SURE ALL LAMPS AND CAMERAS ARE OFF BEFORE YOU COVER MICROSCOPE. 17