UNISONIC TECHNOLOGIES CO., LTD UTT52N15H POWER MOSFET 52A, 150V N-CHANNEL ENHANCEMENT MODE TRENCH POWER MOSFET DESCRIPTION The UTC UTT52N15H is a N-channel, it uses UTC s advanced technology to provide the customers with high switching speed and low gate charge, etc. The UTC UTT52N15H applies to primary side switch, synchronous rectifier, Motor Drives, etc. FEATURES * R DS(ON) < 32mΩ @ =10V, I D =36A * High Cell Density Trench Technology * High Power and Current Handling Capability SYMBOL 1 TO-220 ORDERING INFORMATION Ordering Number Pin Assignment Package Packing Lead Free Halogen Free 1 2 3 UTT52N15HL-TA3-T UTT52N15HG-TA3-T TO-220 G D S Tube Note: Pin Assignment: G: Gate D: Drain S: Source MARKING 1 of 5 Copyright 2017 Unisonic Technologies Co., Ltd
ABSOLUTE MAXIMUM RATING (T C =25 С, unless otherwise specified) PARAMETER SYMBOL RATINGS UNIT Drain-Source Voltage S 150 V Gate-Source Voltage S ±30 V Drain Current Continuous I D 52 A Pulsed (Note 2) I DM 208 A Avalanche Current (Note 2) I AR 51 A Avalanche Energy (Note 3) Single Pulsed (Note 3) E AS 298 mj Peak Diode Recovery dv/dt (Note 4) dv/dt 8 V/ns Power Dissipation P D 230 W Junction Temperature T J +150 C Storage Temperature Range T STG -55 ~ +150 C Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. 2. Repetitive Rating: Pulse width limited by maximum junction temperature. 3. L = 0.22mH, I AS = 52A, = 50V, R G = 25Ω, Starting T J = 25 C. 4. I SD 30A, di/dt 200A/μs, V (BR)DSS, T J = 25 C. THERMAL RESISTANCES CHARACTERISTICS PARAMETER SYMBOL RATINGS UNIT Junction to Ambient θ JA 62.5 C/W Junction to Case θ JC 0.54 C/W ELECTRICAL CHARACTERISTICS (T A =25 С, unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT OFF CHARACTERISTICS Drain-Source Breakdown Voltage BS I D =250µA, =0V 150 V Drain-Source Leakage Current I DSS =150V, =0V 10 µa Gate-Source Leakage Current Forward =+30V, =0V +100 na I GSS Reverse =-30V, =0V -100 na ON CHARACTERISTICS Gate Threshold Voltage (TH) =, I D =250µA 2.0 4.0 V Static Drain-Source On-State Resistance R DS(ON) =10V, I D =36 A 32 mω DYNAMIC PARAMETERS Input Capacitance C ISS 6200 pf Output Capacitance C OSS =0V, =25V, f=1.0mhz 395 pf Reverse Transfer Capacitance C RSS 160 pf SWITCHING PARAMETERS Total Gate Charge (Note 1) Q G 95 nc =120V, =10V, I D =52A, Gate to Source Charge Q GS 28 nc I G =100µA Gate to Drain Charge Q GD 32 nc Turn-on Delay Time (Note 1) t D(ON) 52 ns Rise Time t R =75V, =10V, I D =26A, 58 ns Turn-off Delay Time t D(OFF) R G =25Ω 160 ns Fall-Time t F 143 ns SOURCE- DRAIN DIODE RATINGS AND CHARACTERISTICS Maximum Body-Diode Continuous Current I S 52 A Maximum Body-Diode Pulsed Current I SM 208 A Drain-Source Diode Forward Voltage (Note 1) V SD I S =36A, =0V 1.2 V Reverse Recovery Time (Note 1) t rr I S =30A, =0V, 82 ns Reverse Recovery Charge Q rr di/dt=100a/μs 255 nc Notes: 1. Pulse Test: Pulse width 300μs, Duty cycle 2%. 2. Essentially independent of operating temperature. UNISONIC TECHNOLOGIES CO., LTD 2 of 5
TEST CIRCUITS AND WAVEFORMS DUT + R G - L I SD Driver Same Type as DUT dv/dt controlled by R G I SD controlled by pulse period Peak Diode Recovery dv/dt Test Circuit (Driver) Gate Pulse Width D= Gate Pulse Period 10V I FM, Body Diode Forward Current I SD (DUT) di/dt I RM Body Diode Reverse Current (DUT) Body Diode Recovery dv/dt V SD Body Diode Forward Voltage Drop Peak Diode Recovery dv/dt Test Circuit and Waveforms Peak Diode Recovery dv/dt Waveforms UNISONIC TECHNOLOGIES CO., LTD 3 of 5
TEST CIRCUITS AND WAVEFORMS 90% 10% t D(ON) t R t D(OFF) t F Switching Test Circuit Switching Waveforms Gate Charge Test Circuit Gate Charge Waveform BS I AS I D(t) (t) t p Time Unclamped Inductive Switching Test Circuit Unclamped Inductive Switching Waveforms UNISONIC TECHNOLOGIES CO., LTD 4 of 5
TYPICAL CHARACTERISTICS Gate to Source Voltage, VGS (V) Capacitance, C (pf) UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UNISONIC TECHNOLOGIES CO., LTD 5 of 5