Connection and Operation (Built-In Controller Package)

Similar documents
Connection and Operation

DISCRETE INPUT MODULE, 16 points

Connection and Operation

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

Characteristics and functioning

HD 48V01T... HD 4977T...

Integrated servo motor

Characteristics and functioning

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Servo Motors B-9. Overview. Tuning-Free NX. Tuning-Free NX Series. Servo Motors. Accessories. Page. NX Series B-10 B-9

Thank you for purchasing S100 Profibus-DP Communication Module SAFETY PRECAUTIONS

Logosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP

DS2 series servo drive

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

WARNING Improper operation may result in serious personal injury CAUTION

FD423-EA-000 EtherCAT Servo Drive

Indexer unit JUSP-NS600. System configuration. Smart and simple positioning solution.

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

This operation manual is intended for users with basic knowledge of electricity and electric devices.

Driver. 3 Extension Cables ( Page E-155)

2-Phase Stepping Motor Driver with Built-in Indexer UI2120G

Data Acquisition Modules/ Distributed IO Modules

General Specifications

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

For more information on these functions and others please refer to the PRONET-E User s Manual.

DQM601 / DQM SEP 2003 Page Digital Outputs HE550DQM601 / HE559DQM601 24VDC Out, Negative Logic HE559DQM606 24VDC Out, Positive Logic

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 JUSP-NS500 NS500 SERVOPACK. 200V Ver.

Technical Document. for the. CB 016N6 Driver Card

Installation Guide Multi Position Servo Controller E1100-MP and E1100-MP-HC

WIRELESS MODBUS GATEWAY WGW410

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 NS500 JUSP-NS500 SERVOPACK. 200V Ver.

GS1 Parameter Summary Detailed Parameter Listings...4 9

KNC-SRV-FD423 Series Servo Driver

IP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS

SAFETY INSTRUCTIONS WARNING

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Position Table Function. Closed Loop System. Network Based Motion Control. No Gain Tuning

Rev NGM EVO USER GUIDE

DS2 series 220V servo driver

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

Analog Module D1-15P User Manual

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

Power connections, minimum and maximum wiring capabilities, tightening torque

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

maxon document number:

CHAPTER 3 WIRING DANGER

SV200 DC Servo System

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Compact Actuator DRL Series

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Engineering Data AC Servo Drive HA-680

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

N3 INVERTER SERIES. Operating Manual. 230V 1Ø 0.5-3HP kW. 230V 3Ø HP kW. 460V 3Ø 1-75HP kW. Revision: 2.03.

HA-520 Series Technical Manual

AC SERVO DRIVES SERIES. Servopacks. Certified for ISO9001 and ISO14001

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

10 Error Code List. Motion Control SW. NTI AG / LinMot User Manual Motion Control SW/ Page 87/94

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

7.2 DV1311.L08 and DV1311.L12

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

TOSVERT TM VF-nC3 Parameter List

Troubleshooting Alarm Displays Warning Displays

UMK M A A. RoHS-Compliant. 2-Phase Stepping Motor and Driver Package. Features. Product Number Code. Product Line

Technical guide. EC300 motor V8

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Product Manual QD1010-USB. Description. Contents. Material List. Setup. General Use. USB Cable Use. USB to RS485 Communications Converter

Answering frequently asked Questions (Firmware V.107)

8V General information. 2 Order data 8V

RoHS Directive-Compliant Compact Linear Actuators DRL Series. Features

DSM Dynamic Shunt

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

Connection and Operation

RoHS-Compliant 2-Phase Stepping Motor and Driver Package RBK Series. Features. The RBK Series is a motor and driver package

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

1 Introduction. 1.1 General installation information

EDC Quick Start Guide

RoHS-Compliant 2-Phase Stepping Motor and Driver Package RBK Series. Features

8V General information. 2 Order data 8V

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

30-80V, 8.2A Peak, No Tuning, Nulls loss of Synchronization

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Enhanced SmartDrive40 MDS40B

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Industrial Modbus I/O Modules

Featuring a 100 μs sampling period and ±0.1% linearity

DeviceNet Gateway Unit RCM-GW-DV Operation Manual, Second Edition

Transcription:

(Built-In Controller Package) Names and Functions of Parts Power Supply Input Terminal (CN1) Regeneration Unit Thermal Input Terminal (CN1) Electromagnetic Brake Terminal (CN1) Motor Connector (CN2) CHARGE Regeneration Unit Connection Terminal (CN3) Main Power Supply Input Terminal (CN3) Protective Earth Terminal Signal Monitor Displays Address Number Setting Switch (ID) Termination Resister Setting Switches (TERM.) RS-485 Communication Connector (CN6) RS-485 Communication Connector (CN7) Output Signal Connector () Input Signal Connector () Sensor Signal Connector (CN5) Control Module Connector (CN4) Bottom of the Baud Rate Setting Switch (SW2) Function Setting Switches (SW4) Not used (CN10) Signal Monitor Displays LED Indicators Indication Color Function When Activated PWR Green Power Supply Indication Lights when power is on. ALM Red Alarm Indication Blinks when protective functions are activated. C-DAT Green Communication Indication Blinks or illuminate when communication data is received or sent. C-ERR Red Communication Error Indication Illuminates when there is an error with communication data. Address Number Setting Switch (ID) Indication Switch Name Function ID Address Number Setting Switch Set the address number for RS-485 communication (Factory Setting: 0). Baud Rate Setting Switch (SW2) Indication Switch Name Function SW2 Baud Rate Setting Switch Set the baud rate for RS-485 communications (Factory Setting: 7). Setting the Baud Rate for RS-484 Communications No. 0 9600 1 19200 2 38400 3 57600 4 115200 5 6 Not used 7 Factory setting 8 F Not used Baud Rate (bps) 40

Termination Resister Setting Switches (TERM.) Indication No. Function 1 Set the termination resister (120 Ω) for RS-485 communication (Factory setting: OFF). TERM. 2 OFF: No termination resister ON: Set the termination resister Please use the same settings for both No. 1 and No. 2. Function Setting Switches (SW4) Indication No. Function 1 This sets the address number in combination with the address number setting switch (ID) (Factory setting: OFF). SW4 2 This sets the protocol for RS-485 communication (Factory setting: OFF). RS-485 Communication Protocol Setting No. Destination Modbus RTU Mode 2 OFF ON Input Signal Connector () 1 IN0 HOME This performs the return-to-home operation. 2 IN1 START This performs the positioning operation. 3 IN2 M0 4 IN3 M1 The operating data number is selected using 3 bits. 5 IN4 M2 6 IN5 FREE Stop motor excitation and release the electromagnetic brake. 7 IN6 STOP This stops the motor. 8 IN7 ALM-RST This resets the current alarm. Assigned functions are set by means of the parameter settings. The above is the initial value. For details, refer to the User s Manual. The following input signals can be assigned to input terminals IN0 7. Input Signal 0: Not used 5: SSTART 10: MS2 17: C-ON 27: HMI 36: R4 41: R9 46: R14 51: M3 1: FWD 6: +JOG 11: MS3 18: STOP 32: 37: R5 42: R10 47: R15 52: M4 2: RVS 7: JOG 12: MS4 24: ALM-RST 33: R1 38: R6 43: R11 48: M0 53: M5 3: HOME 8: MS0 13: MS5 25: P-PRESET 34: R2 39: R7 44: R12 49: M1 4: START 9: MS1 16: FREE 26: P-CLR 35: R3 40: R8 45: R13 50: M2 Output Signal Connector () 1 OUT0 HOME-P Output when the motor is home. 2 OUT1 END Output when the positioning operation has finished. 3 OUT2 AREA1 Output when the motor is in area 1. 4 OUT3 READY Output when driver operation preparations have finished. 5 OUT4 WNG The driver's warning status is output. 6 OUT5 ALM The driver's alarm status is output (normally closed). Assigned functions are set by means of the parameter settings. The above is the initial value. For details, refer to the User s Manual. The following output signals can be assigned to output terminals OUT0 5. Output Signal 0: Not used 7: JOG_R 16: FREE_R 36: R4 43: R11 50: M2_R 63: SLIT_R 71: TLC 1: FWD_R 8: MS0_R 17: C-ON_R 37: R5 44: R12 51: M3_R 65: ALM 72: TIM 2: RVS_R 9: MS1_R 18: STOP_R 38: R6 45: R13 52: M4_R 66: WNG 73: AREA1 3: HOME_R 10: MS2_R 32: 39: R7 46: R14 53: M5_R 67: READY 74: AREA2 4: START_R 11: MS3_R 33: R1 40: R8 47: R15 60: +LS_R 68: MOVE 75: AREA3 5: SSTART_R 12: MS4_R 34: R2 41: R9 48: M0_R 61: LS_R 69: END 80: S-BSY 6: +JOG_R 13: MS5_R 35: R3 42: R10 49: M1_R 62: HOMES_R 70: HOME-P 82: MPS Sensor Signal Connector (CN5) 1 +LS +Side Limit Sensor Input 2 LS Side Limit Sensor Input CN5 3 HOMES Mechanical Home Sensor Input 4 SLIT Slit Sensor Input 5 IN-COM2 Common for Sensor Input/Regeneration Unit Thermal Input/Electromagnetic Brake Connction Terminal (CN1) Indication I/O Terminal Name Content 24V+ Power Input Terminal+ This is the power supply for the driver's control circuit terminal. Always connect when using. 24V Power Input Terminal Input TH1 Regeneration Unit Thermal Input Terminal Connects the accessory regeneration unit RGB100 (sold separately). TH2 Regeneration Unit Thermal Input Terminal Short circuit between the terminals when no regeneration unit is connected. MB1 Electromagnetic Brake Connection Terminal Output This connects the electromagnetic brake line of an electromagnetic brake type motor. MB2 Electromagnetic Brake Connection Terminal+ 41

Connection Diagram Connection to Peripheral Equipment Motor Regeneration Unit (RGB100) Motor Cable (Included) 1 Thermostat Output [AWG22 (0.3 mm 2 )] 2 Leads Regeneration Unit [AWG18 (0.75 mm 2 )] 2 Leads Connect to CN1. GND Output Signal: Connect to. Input Signal: Connect to. Included in the product. Available as accessories (sold separately). Controller 2 Sensor Signal: Connect to CN5. Control Module (OPX-2A) Power Supply 2 Always connect when using. or Data Setting Software (MEXE02) Power Supply Voltage Single-Phase 200-24AC 50/60 Hz Circuit Breaker or Ground Fault Interrupt Circuit 2 Noise Filter 2 1 Each model comes with a motor cable 1, 2 or 3 m long. If you need a cable of a different length or a flexible cable, select an appropriate cable from among the accessories (sold separately). Keep the wiring distance between the motor and driver to 30 m max. 2 Not supplied. Connecting a Main Power Supply Use the following cable for the power supply line; 3-core cable of AWG16 to 14 (1.25 to 2.0 mm 2 ) Single-Phase 200-24AC 50/60 Hz CN3 Connector Connect to CN3 of the driver. Connecting the Control Power Supply Provide a power supply. Power Supply ±5% 0.5 A min. Motor Cable CN1 Connector Cable for Motor (Included) AWG28 16 0.08 1.25 mm 2 + 24 V+ 24 V Connecting the Electromagnetic Brake Power Supply ±5% 0.75 A min. Electromagnetic Brake Cable Motor Cable CN1 Connector Connect to CN1. Cable for Electromagnetic Brake (Included) Cable for Motor (Included) AWG28 16 (0.08 1.25 mm 2 ) + Black White 24 V+ 24 V MB1 MB2 If the distance between the motor and driver is extended to 20 m or longer, use a power supply of ±4%. 42

Connecting to a Host Controller Connecting to a Current Source Output Circuit Controller 12 to 10 ma max. OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT-COM IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN-COM1 Output Saturation Voltage 3 VDC max. PNP Sensor +LS LS HOMES SLIT IN-COM2 CN5 Note Use input signals at. Use output signals at or less. If the current exceeds 10 ma, connect an external resistor. The saturation voltage of the output signal is 3 VDC max. Provide a minimum distance of 200 mm between the signal lines and power lines (AC lines, motor lines). Do not run the signal lines in the same duct as power lines nor bundle them with power lines. If noise generated by the motor cable or power supply cable causes a problem with the specific wiring or layout, shield the cable or use ferrite cores. 43

Connecting to a Host Controller Connecting to a Current Sink Output Circuit Controller 12 to NPN Sensor 10 ma max. OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT-COM IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN-COM1 +LS LS HOMES SLIT IN-COM2 CN5 Output Saturation Voltage 3 VDC max. Note Use input signals at. Use output signals at or less. If the current exceeds 10 ma, connect an external resistor. The saturation voltage of the output signal is 3 VDC max. Provide a minimum distance of 200 mm between the signal lines and power lines (AC lines, motor lines). Do not run the signal lines in the same duct as power lines nor bundle them with power lines. If noise generated by the motor cable or power supply cable causes a problem with the specific wiring or layout, shield the cable or use ferrite cores. 44