Things to check before start-up.

Similar documents
Leica SP8 TCS Users Manual

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Leica SPEII confocal microscope. Short Manual

LSM 710 Confocal Microscope Standard Operation Protocol

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Guide to Confocal 5. Starting session

Leica SP8 TCS Users Manual

Quick Start Guide. Leica SP5 X

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Cell Biology and Bioimaging Core

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Operating Instructions for Zeiss LSM 510

Leica Sp5 II Confocal User Guide

Leica TCS SL Confocal Training. Neuroscience Imaging Core Staff. Core Director. Facility Manager

TRAINING MANUAL. Olympus FV1000

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

LSM 780 Confocal Microscope Standard Operation Protocol

Zeiss 880 Training Notes Zen 2.3

Brief manual how to start and close the Leica sp2 Confocal. (TCS SP2 AOBS system mounted on a DM IRE2)

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Title: Leica SP5 Confocal User Manual

Zeiss LSM 880 Protocol

Leica TCS SP8 Quick Start Guide

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

OPERATING INSTRUCTIONS

Leica Confocal - 2. Instructions for Leica SP2 Confocal Equipped with Visible Laser Lines

Zeiss LSM 780 Protocol

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

ZEISS LSM510META confocal manual

Leica TCS SP8 Quick Start Guide

Microscopy from Carl Zeiss

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Leica SP8 Resonant Confocal. Quick-Start Guide

Microscope Confocal Sp2 Upright.

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

b. Turn the power switch and key to on position for blue laser.

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

LSM 510 Training Notes

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

LSM 510 Meta Training Notes

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

Using the Nikon TE2000 Inverted Microscope

LSM 800 Confocal Microscope Standard Operation Protocol

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.

Leica TCS SP2 User Manual 1.1. Markus Friedrich and James Lee. Department of Biological Sciences Wayne State University

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Instructions for the Leica SP5 II laser scanning confocal microscope

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

Zeiss 780 Training Notes

Internal Medicine Imaging Core Emory University Department of Medicine

CONFOCAL MICROSCOPE (Zeiss LSM 510 META v4.2)

Practical work no. 3: Confocal Live Cell Microscopy

Contents. Introduction

Microscope Confocal LSM510 META

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

Microscopy Suite. The Multi-Photon Confocal Microscope. Instructions for Leica SP2 Microscope #1 By Jon Ekman & Karl Garsha. Start-up.

Zeiss Axio Imager.A1 manual

The Leica Confocal Microscope System B46 Weill Hall (revised 4/01/10)

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

Zeiss LSM880 Operating Instructions. UTMB Optical Microscopy Core Jan. 16, 2018

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

Nikon A1R. Multi-Photon & Laser Scanning Confocal Microscope. Kyle Marchuk Adam Fries Jordan Briscoe Kaitlin Corbin. April 2017.

ZEISS LSM 710 NLO Multiphoton microscope Manual/Quick guide

Nikon SIM-E & A1-R System

User Guide to the IBIF Leica TCS SP8 MP Confocal Microscope

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

The Zeiss AiryScan System, Confocal Four.

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

RENISHAW INVIA RAMAN SPECTROMETER

Instructions for Making On-Line Reservations for Microscopes in NB11-204

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Zeiss Deconvolution Microscope: A Quick Guide

Title: Nikon A1R Confocal User Manual

Usermanual for Leica SP8 confocal

Diskovery Spinning Disk Guide

Zeiss LSM 510 Multiphoton Confocal Microscope

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

Nikon A1Rsi Confocal Start-Up Sequence

1 Co Localization and Working flow with the lsm700

Zeiss LSM 510 Multiphoton Confocal Microscope

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

1 Set up the confocal light path for imaging a green dye (Alexa488-EGFP). For example, the

Last updated: May 2014 Y.DeGraaf

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

Widefield 1. Switching on

SlideBook 5. FRAP Imaging Module

Zeiss AxioObserver with ApoTome

Zeiss AxioImager.Z2 Brightfield Protocol

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

Olympus Confocal Microscope User Guide Last updated

Supplemental Method Information Zeiss LSM710

Nikon TE300 Eclipse Wide-Field Microscope

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Transcription:

Byeong Cha Page 1 11/24/2009 Manual for Leica SP2 Confocal Microscope Enter you name, the date, the time, and the account number in the user log book. Things to check before start-up. Make sure that your sample slides are clean and sealed. Use Windex and cotton balls or Kimwipes to clean coverslips. Fixed samples need to be sealed with nail polish. Check the objectives. The 10x and 20x objectives are DRY objectives, and should NEVER have oil on them! There are 40x and 63x OIL immersion objectives, and a 63x WATER immersion objective also on this microscope. If oil immersion objectives have oil on them, wipe the lens gently only with lens paper. With the microscope controller ON, you see the information of the objective in position on the reading panel at the front of the microscope. The order of the objective lenses in the lens turret is:10x, 20X, 40X Oil, 63X Oil, and 63X Water. The 63X objective has aperture collar adjustment rings that control the size of aperture opening. It should be wide open for most imaging condition. If your sample looks dim or the whole view field is not illuminated evenly when you look through the eyepieces, turn the collar to open the aperture. The field diaphragm and aperture diaphragm in the excitation path of the mercury lamp are controlled by round, black dials on the left side toward the back of the microscope, and control the fluorescence illumination from the mercury lamp. For all imaging with the mercury light source, these should be set wide open by turning all the way counter-clockwise. Setting up for bright-field and fluorescence viewing. Basic Operation of Leica DM IRE2 Microsocpe. Turn on the microscope controller. Turn on the mercury arc lamp. Bright-field viewing: Place your sample slide with coverslip (preferably #1.5 thickness) facing down to the objective on the stage. For bright-field viewing, turn on the microscope light by turning the wheel toward you and turn the VIS-SCAN switch to VIS position (Note: switch back to Scan position for confocal scanning, see below) Start with low magnification objectives (10X or 20X) first to find and focus onto your specimen. The information of the selected objective and their z-

Byeong Cha Page 2 11/24/2009 position can be read on the readout panel at the front of the scope. You can place the desired objective in position by turning the lens turret by hand or by pressing the objective change button on the left side of the microscope. Pressing upper objective change button once rotates in next higher objective into place and pressing lower change button rotates in next lower objective into place. However, pressing these buttons does not change between dry and oil objectives. To do this, first press buttons simultaneously, and when the readout panel reads change objective I (or D by pressing again), then push the objective change button. 1 To focus, use coarse movement button (upper one for bring lens up to a safety distance, 0 position and lower one for lowering lens down) and fine focus knob (9) for focusing. The coarseness of focusing movement ( S0 (fine) to S3 (coarse)) can be set by pressing STEP button. For using oil or water immersion lens, lower the objective turret slightly, expose the lens by turning the turret half way, and place a drop of oil or water on the objective (be careful not to touch the lens directly with application tools!). Place the slide over the objective and raise the objective until the oil just spreads out as it contacts the slide. Use find focus knob to gradually bring your sample into focus. Check your slide occasionally to make sure that you are not pushing up the slide with the objective. This can damage the objective lens and your sample! Please DO NOT press LEARN and CHANGE buttons. Fluorescent viewing: You can check your sample to see if your fluorescence labeling works by using the mercury lamp illumination and the appropriate filter set. The microscope has filter sets for viewing DAPI (A), Green fluorescence (I3) and red fluorescence (N2.1). Press the arrow horizontal button on the front of the scope to choose the filter set. Scan position has no filter set in place and is used for laser confocal scanning. The fluorescent light can be blocked (closed) or emitted by pressing Shutter button. The closed light should be off for fluorescent viewing. Turn the VIS-SCAN switch to Scan position to block the transmitted bright-field light, if necessary.

Byeong Cha Page 3 11/24/2009 Setting up for Confocal Imaging. Turn on the Scanner/Laser He/Ne switch (the scanner should be on for about 1 min before starting the LCS program). Turn on the PC/Stand switch and turn on the computer. Log onto using your User ID and password or TCS User. Start the LCS program by doubleclicking the LCS icon. On the main menu, select the Personal that contains your setting for acquisition parameters you have created or Company for a default setting. To start the laser(s); (1) Turn on only the lasers you will use. They do not need more than a minute or so to warm up and stabilize, so it is not necessary to turn them on until you know you need them. (2) Argon (for 458, 476, 488, and 514 nm laser): Turn on the red Laser Ar/ArKr switch and turn the Level Ar/ArKr knob to MIN. Then, turn the left Ar/ArKr key to ON, then push to START and release. Adjust the laser power with LEVEL knob (usually 9 o clock position is sufficient). (3) Melles Griot yellow DPSS (561 nm) laser: push the green button. (4) He/Ne (633 nm) laser: turn on the right He/Ne 633 key. (5) Diode UV laser 405 nm: Turn on the red power button and turn the key to I position.

Byeong Cha Page 4 11/24/2009 LCS Imaging program setting Upon LCS program start, the basic image acquisition menu will appear. The Acquire button should appear pressed. Laser power level Dichroic beamsplitter setting Detector bandwidth and range Detector selector & pseudo-color selector Click Beam button and select the appropriate detector setup for the fluorescent labels you used on your sample from the drop-down list. This will set up the emission detector band-width, activate the proper detector (PMTs), dichroic beamsplitter, and excitation laser wavelength and power. You can adjust the range and position of detector bandwidth and the laser power level as necessary. You also can change the color scheme of individual images into any color or grey scale by clicking the pseudo-color selector associated with PMTs on the window screen (Note: the color information will be saved with image files when saved). Press Mode button to select Scan Mode (default is XYZ). Press Format, Speed, and Bit buttons to select these parameters (defaults are 512x512 format, 400Hz scan speed, and 8 bit image).

Byeong Cha Page 5 11/24/2009 Press Z-scan button and select z-wide in order to use Z POS knob to move the objective for focusing (Default is z-galvo, which is used with Galvo stage adaptor). Click MicCtrl button to switch to Visual mode, in which you can examine your sample visually at the microscope. Switch MicCtrl to Scan mode for laser scanning (it will automatically shut off visual output through the eyepieces). Press Continuous button to start scanning. An image or images, depending on the number of active detectors, will appear on the right monitor. Control Panel Optimize the images by adjusting parameters including; The z-position (focusing) within the specimen (Z-POS knob). Zoom factor (ZOOM knob ): Default is 1. Increasing zoom will magnify the image but also will bleach the sample faster! PMT and Smart Offset knobs : Turn PMT knobs to increase the signal intensity of each fluorescent and transmission image channel. To decrease background signal, click the mouse over the image channel to select it and turn Offset knob counterclockwise. By activating Q LUT button, a full dynamic range of the PMT can be obtained. In this mode, pixels saturating the PMT will appear blue and pixels which are black (0 value) appear green. Set the PMT gain so that the brightest pixels are just under the saturation and set the PMT offset such that the darkest pixels are just above the zero value. Laser power: adjust with dragging the laser power bar on the menu window if necessary. Click the Continuous button again to stop scanning. You can save the current parameter setting with Save button for later use.

Byeong Cha Page 6 11/24/2009 Working with Images. Single button puts up full screen of one fluorescent channel. Ch1, 2, 3, 4 buttons activate the channel on the screen. Tiled button views up to 3 channels simultaneously. Ovl button overlays (merge) multiple channels into one. Lut button- open color look up table. Acquiring Single Optical Section Image. Make sure to switch MicCtrl to Scan mode. Press Single Scan button to acquire an image by a single laser scanning at a scanning speed (normally 400Hz). The resulting image may display background noise. Image averaging is a process to decrease this noise and improve the signal-to-noise ratio. To use averaging, click either Aver (frame averaging) or Li.A. (line averaging) button and select the number of frames (or lines) to be averaged. Then, click Single Scan button. Sequential Scanning Mode This confocal microscopy can detect up to four fluorophores simultaneously as long as all the excitation and emission spectra of fluorophores are well separated. Imaging of samples stained with different dyes thus simply requires manipulation of laser power and adjustment of the detector bandwidth. However, often excitation of one fluorophore may cause emission into the range of another (bleed-through) or can be induced by neighboring laser lines (cross-talk), which produce false signals. To avoid these, the sample can be scanned sequentially by collecting one fluorophore signal at any given time.

Byeong Cha Page 7 11/24/2009 To scan sequentially: Choose the beam setting parameter for your fluorophores (i.e. GFP and DsRED) by selecting laser lines, dichroic mirror, and PMTs. Set up a condition for one fluorophore by only activating and adjusting laser level and PMTs. Save this parameter set up as your own setting (i.e. GFP-seq ). Repeat the same process for the other fluorophore and save the condition as another setting (i.e. DsREDseq ).

Byeong Cha Page 8 11/24/2009 Click the Seq button in the beam window. Add the fluorophore acquisition setting one at a time by selecting them in the beam window and then click Add button in the Sequential scan settings window. Keep the scan mode at between lines Do not close the settings window. You can save these sequential acquisition settings by Save button. Start the acquisition by clicking Single Scan or Series button depending on your imaging condition. Acquiring Z-series images. Z-series allows obtaining optical sections through the certain volume of your sample that can be used for making 3D images. To set the z range, press Continuous button (it will be highlighted with Stop ), turn Z-POS knob in a direction to focus to a specific z position of your sample and click Begin button (it will appear depressed). Turn Z-POS in opposite direction to reach a desired position and click End button. Click Stop button to stop scanning. Click Series button to check the thickness of the z-series and determine the number of optical sections.

Byeong Cha Page 9 11/24/2009 Click Sect button to select the predetermined number of optical section, or to select Others It brings up a z-configuration window to determine the number of sections and spacing (step size) between sections. Press OK. Choose the number of averaging using Aver button and click Series button to begin Z-series stack imaging. Acquiring Time Series images. Time series allows time-lapse imaging of live samples to study the changes and dynamics of your object of interest. The movie can be saved as multiple Tiff files and AVI files for playing in movie programs. To set obtain time-series images, select scan Mode as xyt (or other modes containing t ). It will activate Time button. Click Time button to open the time-lapse setting dialogue and set the parameters such as the time interval between frames and the number of frames. Hit Enter key on keyboard, which will calculate the complete time. Click Apply. Set time interval Set the number of frames (Option) Click on Aver or Li.A. button to set the number of averaging per frame. Note: If your object of interest changes or move faster than scanning speed, averaging will generate distorted or ghost images. To increase the signal, use slower scan speed. Click Series button to start the time series imaging.

Byeong Cha Page 10 11/24/2009 Saving Images. This is a very important for your effort and data. Computer crash or power outage will result in loss of unsaved data! SAVE FREQUENTLY!! To save the imaging data files, click Save button at the top of the window. Select D drive and users folder. Create your folder, rename the Experiment# and save. Since the storage memory in the computer will be filled up quickly and this lack of hard drive space prevents image acquisition, all user files will be deleted after two weeks. Be sure to copy your files to a flash memory or CD/DVD disks. Shut-down Procedure Please enter your time of use in the log book and note any problems and suggestions during your time. 1. Clean the oil from the objectives only with lens paper (not Kimwipe). Clean the microscope and stage. 2. Close the LCS program. 3. Copy your data files to a flash drive or CD. Users are responsible for their own files, as there is no automatic backup at present. 4. Log off the computer (not turning off the computer) and turn off the microscope control box. 5. If the next user won t be ready within 1 hour: Turn off the mercury lamp. 6. If you are the last user of the day: a. Turn off the mercury lamp. b. Minimize the power of the Ar for >3min before turning it off. c. For the Ar laser, turn the key to off and after 10 min turn off the red button switch. d. Turn the Melles Griot DPSS laser off by pushing the OFF button. e. For the He/Ne, turn the key to off position. f. Exit windows and shut down the power for PC stand, Scanner/Laser HeNe, and Laser Ar/Kr with the red buttons.