LED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300

Similar documents
Modbus communication module for TCX2: AEX-MOD

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

WIRELESS MODBUS GATEWAY WGW410

RADIOBAND V3 Programming & Installation Manual

2015 / 9C EN-00 OSRAM GmbH Marcel-Breuer-Str München Germany. Radio and Telecommunications Terminal Equipment

ZHUHAI PILOT TECHNOLOGY CO., LTD.

COD GB / 1.0 RBAND/UMS - RBAND/CSM

433MHz LRS Adjustable TX/RX Set 100mW-2000mW

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 6.2 June 12, 2013 USER MANUAL. metaphase-tech.com. pg. 1

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Wireless Room Thermostat Installation and Operation Y6630D1007

Data Acquisition Modules/ Distributed IO Modules

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Analogue temperature controllers

800W Single Output Power Supply

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

Industrial Modbus I/O Modules

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

RS Pro ENGLISH. Datasheet

The wireless alternative to expensive cabling...

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1

The technology allows for flexible current setpoint characteristics while maintaining compliance with the requirements for a NEC Class 2 output.

User Manual March 2008

PROCESS & TEMPERATURE CONTROLLERS

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

AT-SL-DDR & AT-SL-DDR-SA

Wireless multizone receiver RDE-MZ6

AT-SL-ADR & AT-SL-ADR/SA

LED converter Compact dimming. Uconverter LCAI 55 W 1400 ma O010 DALI ECO series Ø4,4. Ordering data

AL-DALI-010v 0-10v Dimmer 3-Way switch with DALI

satech SynchroStar GPS 200 Series

R-Log Radio data logger

dmx2pwm 9 channel dimmer setup manual

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

AT-SL-DDR & AT-SL-DDR-SA

ZITARES CC Constant current control gear, 2-channel, dimmable

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

P5201 Universal Programmable Transmitters with Galvanic Isolation

CAN-IO Custom IO remote module

Data Sheet. RISH Master Record %THD

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

focushand 2 Users Manual FocusHAND System description

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

contents W-DMX UglyBox MKII User Manual Issue date: Edition: 1

Plus III Basics. Remote Flash Triggering. Connecting. Powering On/Off. Channels & Zones. Plus III FAQ

Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Main Features. Highlights

RS Pro ENGLISH. Datasheet

Personalize your pool

OVEN INDUSTRIES, INC. Model 5C7-362

WIRELESS DIMMER FOR HEATING

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Simplified Operations for TM-3100 Series Digital Tachometer

Digital Multifunction Instrument - Rish Master 3440

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

SWT 3000 Teleprotection technical data siemens.com

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

Model Microphone Preamplifier Power Supply Manual

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

DPF-MAC Auto power factor controller

Quick Guide. FCC/IC: MHz CE: MHz

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

High power radio transmission module MR03 type

ET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

Enclosed Power Supplies

The wireless alternative to expensive cabling...

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

B850 Boiler House Energy Monitor

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

ZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

Local Control Network - building controls in perfection

DALI RM8 PWM DALI RM8 1-10V DALI RM V

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

FTU233. Ripple Control Receiver. Technical Data. Load Management Ripple Control

MD12-2 Metal Loop Detector

R&TTE Testing For EU Market

SINGLE PHASE STS PREPAID METER

Transcription:

LED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300 lighting 402-0036-160914 Multi-functional Controller for Spectravision Pool Lights and 2 auxiliary circuits

Table of contents Technical specifications General Specifications... PLP-REM-300 overview... Logic board... Installation Instructions Single PLP-REM-300 unit... Multiple PLP-REM-300 installation... Operation modes... DIP switch functionalities... Transmitter functions MODE 1: PLC CONTROL... MODE 2: ON/OFF CONTROL... Replacing transmitter keypad... Pairing the handheld transmitter... DMX 512 communication Single PLP-REM-300 unit... Multiple PLP-REM-300 installation... RS485 communication Single PLP-REM-300 unit... Multiple PLP-REM-300 installation... RS485 command set... RESET procedure... Troubleshooting... Transmitter battery... Page 4 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 10 Page 11 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 18 lighting page 3 of 20

Technical specifications General specifications Input Voltage: 230 VAC 50/60Hz Output Voltage: 12,5 VAC Transformer VA rating: 300VA Max output Power: 300 VA (12 VAC / 25A) Max rating relay contact A &B 16A / 250 VAC Max switching power A & B 4000VA RF band 868 MHz Ambient Air Temperature: 0 C to +40 C Humidity 10% to 90% RH - non condensing Ingress protection rate: IP54 IEC Protection Class: Class II PLP-REM-300 overview 12 VAC Transformer Integrated toroïdal Transformer 350VA Logic board For details: see next page Circuit breakers 12VAC connection terminals To connect the pool lights page 4 of 20

Logic board DMX Address dial To choose the DMX start address DIP switch To select controller functionalities Pairing button (1) (2) RESET BUTTON Ethernet port (9) SD card slot (3) (4) (5) (6) CAN bus If multiple PLP-REM-300 s are used, you can connect them (7) (8) RS485 connection To connect to home automation system (see page 14) 12VAC connection terminals To connect the pool lights A/B output For auxiliary circuits Acts as a SPST (single-pole, singlethrow) switch DMX input/outpout The PLP-REM can act as a DMX receiver with DMX passthrough Status LED s: (1) General status: Green = OK Red = error (2) RESET status (see page 17) (3) 12VAC to Pool lamps (Green = ON) (4) Switch A (Green = ON) (5) Switch B status (Green = ON) (6) CAN status (7) RS485 signal (8) DMX signal (9) Pairing status (see page 11) page 5 of 20

Installation Instructions Single PLP-REM-300 unit. Connect a power source to the terminals of the PLP-REM-300. Connect the pool lights to the 12VAC connection terminal block in the PLP-REM-300.. The PLP-REM-300 has a 300VA transformer built in. The total power load of pool lights can not exceed this. Connect the power source to the circuit breaker Connect the pool lights to the 12VAC terminals page 6 of 20

Multiple PLP-REM-300 installation For extended installations (total lamp power > 300VA), multiple PLP-REM-300 s can be linked together. This way, a perfect synchronisation of all pool lights is still guaranteed. The PLP-REM-300 s need to communicate to each other, to ensure all the lamps are in perfect sync. There are 2 options: 1) Connect Wirelessly This is done automatically. Each PLP-REM-300 has a built in wireless module that detects other PLP-REM-300 s nearby. 2) Connect Hardwired Preferred if multiple PLP-REM-300 s are at a very long distance from each-other. Connect the PLP-REM-300 s with each other in PARALLEL: Connect the CAN terminals of the first PLP-REM-300 with the CAN terminal of the second PLP-REM-300. If more than 2 PLP-REM-300 s are necessary, simply daisy chain each CAN terminal with the one from the next PLP-REM-300 (see below). Respect the polarity of the terminals! (CAN L & H) CAN BUS page 7 of 20

Operation Modes The PLP-REM-300 controller has 2 main operation modes: ON/OFF control mode & PLC control mode. Each mode has it s own functionalities: ON/OFF control PLC control Compatible lamps Switch lamps ON/OFF YES YES Change lamp color YES (1) YES (1) Operate Relay A & B YES YES Dimming lamps NO YES (1) DMX control NO YES RS485 control YES (2) YES Dip switch setting DIP 1 ON DIP 1 OFF Remote keypad type (3) 1) Only for RGB lamps 2) In ON/OFF control mode, only a few RS485 commands are available (see p 16) 3) Depending on which control mode is selected, the keypad of the transmitter needs to be changed page 8 of 20

DIP switch functionalities The DIP switch on the main circuit board of the PLP-REM-300 allows the user to customise the way the PLP-REM-300 operates. ON position OFF position DIP SWITCH function setting 1 2 3 4 5 6 Mode of operation Relay A Relay B ON/OFF CONTROL pulse duration DMX MASTER/SLAVE mode ON/OFF PLC PULSE mode TOGGLE mode PULSE mode TOGGLE mode SHORT LONG NO LOOP LOOP SLAVE MASTER ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF * ON/OFF color change To change colors, the lamps need to switch OFF and then back ON. In FAST ON/OFF mode, this switching transition is not noticeable and the lamps change color very smoothly page 9 of 20

Transmitter functions MODE 1: PLC CONTROL (default mode) Short push (< 1 sec): Toggle the lamp ON of OFF (1) Long push (> 2 sec (2) ): All lamps & 12VAC TO LAMPS relay are turned OFF (1) Short push: Go to next color program Long push: Toggle output A ON/OFF Short push: Go to the previous color program Long push: Toggle output B ON/OFF Short push: Select next dimming level: 100% -- 50% -- 25% ---> 100% --... Long push: Set lamps to Program 1 (blue) & full brightness MODE 2: ON/OFF CONTROL Short push (< 1 sec): Toggle the lamp ON of OFF (1) Long push (> 2 sec (2) ): All lamps & 12VAC TO LAMPS relay are turned OFF (1) page 10 of 20 Short push: Go to next color program Long push: Auto sync procedure (3) Short push: Toggle output A ON/OFF Long push: / Short push: Toggle output B ON/OFF Long push: / (1) Lamp ON or OFF status is memorized after power down (2) The green LED in the transmitter will light up as soon as you start pressing a button, and will stop after 2 seconds, so you know exactly when to release the button. (3) The lamps will be turned off for 30 seconds and then switched ON/OFF 3 times. This will set all lamps to program 1: blue

Replacing transmitter Keypad Depending on which control mode is selected, the keypad of the transmitter needs to be changed: Remove the philips head screw and open the transmitter Replace the Keypad in the top part of the transmitter housing Reassemble in reverse order Keypad for PLC mode Keypad for ON/OFF mode Pairing the handheld remote to the PLP-REM-300 All handheld transmitters are already paired in the factory and ready to use. In case a problem arises, the pairing process can be done as below: 1) Press the pairing button on the small circuit board, inside the PLP-REM-300 for at least 5 seconds ---> The GREEN LED will start to blink fast 2) Within 25 seconds, push any button on the handheld transmitter. ---> If the remote is paired correctly, the GREEN LED will flash slowly for 5 times ---> UNPAIRING: If no button is pushed within 25 seconds, the pairing memory of the PLP-REM will be cleared. All remotes will be unpaired from the PLP-REM (in this unpaired mode, the PLP-REM will communicate with ANY transmitter) Pairing button Pairing Indicator LED (green) page 11 of 20

DMX 512 communication Single PLP-REM-300 unit Address dial DMX PANEL Connect DMX panel to DMX IN (+/-) Address dial setup Setting the DMX address of the PLP-REM-300: Select the desired number on the address dial. The chosen number determines the DMX addresses of the PLP-REM-300 & lamps. Each lamp uses 3 bytes of DMX data (R-G-B), and all lamps receive the same DMX data from the PLP-REM-300. Address dial position 0 1 2... R G B R G B R G B... DMX address 1 2 3 4 5 6 7 8 9... The DMX start address can be overruled by using the RS-485 command: set DMX start address (see page 16) page 12 of 20

Multiple PLP-REM-300 installation 1) Connect the DMX panel to the DMX IN port of the first PLP-REM-300 2) Connect the PLP-REM-300 s with each other (open loop): DMX OUT --> DMX IN (polarized terminals + -) 3) Set the DMX address for each PLP-REM-300 via the address dial. - Option 1: All PLP-REM-300 s can be set to the same address: This implies that all lamps will receive the same DMX data, And will all operate identically - Option 2: PLP-REM-300 s can be set to different addresses: Each PLP-REM-300 will have it s own group of connected lamps that will operate identically. However, since each PLP-REM-300 has it s own unique address, the different lamp groups can be controlled separately DMX PANEL Address dial Address dial Address dial page 13 of 20

RS485 communication Single PLP-REM-300 unit 1) Connect the RS485 source to the 485 port on the PLP-REM-300 2) Communication settings: 9600, 8, 1, n 3) Command list: see page 16 RS485 Source page 14 of 20

Multiple PLP-REM-300 installation 1) Connect the RS485 panel to the RS-485 port of the first PLP-REM-300 2) Connect the PLP-REM-300s with each other in PARALLEL: Connect the CAN terminals of the first PLP-REM-300 with the CAN terminal of the second PLP-REM-300. If more than 2 PLP-REM-300s are necessary, simply daisy chain each CAN terminal with the one from the next PLP-REM-300. Respect the polarity of the terminals! (CAN H & L) CAN BUS RS485 Source page 15 of 20

RS485 Command set Command Command Remark Example available in ON/OFF mode available in PLC mode Lamps OFF PL0 All lamps OFF X X Lamps ON PL1 All lamps ON X X Program UP PsU Jump to next program X X Program Down PsD Return to previous program X Set Program PSxx xx is the decimal representation of the program number (01-14) PS06 = jump to program 6 X Auto sync procedure PsS executes the auto sync procedure (see page 10) X X White 1 PW1 Jump to White 1 (program 12) X White 2 PW2 Jump to White 2 (program 13) X White 3 PW3 Jump to White 3 (program 14) X Set RGB PCrrrgggbbb rrr, ggg and bbb are the decimal representation of the RGB value (with leading zero s) 1) PC255128064 = Full output level on Red color, half output level on Green color, 1/4 output level on Blue color 2) PC255255255 = All colors at full output level 3) PC000000000 = All colors OFF X Set Dim value PDxxx set the OUTPUT value of the lamp in % (000-100) PD075 = 75% output level (on all LED s) X set DMX startadress PAxxxyz y = e or E PA035E = set DMX start address to 35 [35(R), 36(G), 37(B)] X Set color in percentage Pprgbe variable size, rgb = ASCII 0-255, e = end character Pp25050100e = Red 25%, Green 50%, Blue 100% X Set color in hex Pcrgbe variable size, rgb = ASCII 0-255, e = end character Pc64128255e = Red 25%, Green 50%, Blue 100% X Relay A control PRAx x = 1 (ON), 0 (OFF), P (Pulse)!this overrules dipswitch PRA1 = Relay A ON PRA0 = Relay A OFF X X Relay B control PRBx x = 1 (ON), 0 (OFF), P (Pulse)!this overrules dipswitch PRB1 = Relay B ON PRB0 = Relay B OFF X X ON/OFF relay control PRMx x = 1 (ON), 0 (OFF) PRM1 = Relay ON/OFF control ON X X Color temperature PTxyz x = ten thousand ; y = thousand ; z = hundred PT035 = Set white color temperature to 3500K (in steps of 500K) X page 16 of 20

RESET procedure RESET procedure for the control board 1) Make sure the PLP-REM-300 is switched ON 2) Press and hold the RESET button on the logic board for minimum 5 seconds. (the blue LED will light up as soon as you press, and will stop after 5 secs, so you know exactly when to release the button) 3) Release the RESET button The control board has been RESET. Blue LED RESET button page 17 of 20

Troubleshooting PROBLEM The PLP-REM-300 doesn t react to transmitter commands SOLUTION Perform a RESET procedure Check the battery of the handheld transmitter (see below) The transmitter is not pairedcorrectly with the PLP-REM-300. Repeat the pairing process Reduce the distance between handheld transmitter and PLP- REM-300 and/or remove obstacles The pool lights don t work Perform a RESET procedure Check if all connections are made according to the electrical scheme. Transmitter battery Check battery status: Push and release any button on the remote. The green LED should still light up 1 second after you released. If the LED stops faster, then the battery needs to be replaced Replacing transmitter battery: Remove the philips head screw and open the transmitter Replace the battery, respecting the polarity Battery type: A23 12V + - page 18 of 20

Declaration of Conformity We, Propulsion Systems bvba, declare under our sole responsibility, that the equipment described below conforms with the essential requirements of the following directives and standards: DIRECTIVE 2011/65/EC (RoHs 2) EN 50581 DIRECTIVE 1999/5/EC Radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity EN 300 220 Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 Mhz to 1000 Mhz frequency range with power levels ranging up to 500 mw DIRECTIVE 2006/95/EC (LVD) Low Voltage Directive EN 61347-1 Control gear safety EN 61347-2-13 Control gear for LED modules DIRECTIVE 2004/108/EC Electromagnetic compatibility EN 300 683 Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for Short Range Devices (SRD) operating on frequencies between 9 khz and 25 GHz EN 301 489-3 Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services, Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 khz and 40 GHz EN 55015:2009 EMC radio disturbance EN 61000-3-2:2009 EMC harmonic current EN 61547:2009 EMC immunity requirements Equipment: handheld transmitter/receiver for remote control & base unit transmitter/ receiver 868MHz band DuraLink Trade Mark: SpectraVision Model Nr.: PLA-REM PLA-REM-300 PL-REM PL-REM-P PL-REM-200 PLP-REM PLP-REM-300 TX868-PLA TX868-PL Description: Communications & remote control box for Adagio+ RGB DuraLink 350VA PSU & comms box for Adagio+ RGB DuraLink Remote control for Moonlight, Adagio+, Adagio Pro DuraLink Remote control for Moonlight, Adagio+, Adagio Pro (Pulsed) DuraLink 200VA PSU & remote control for Moonlight, Adagio+, Adagio Pro DuraLink Communications & remote control box for Spectravision lamps Duralink 350VA PSU & comms box for Spectravision lamps DuraLink Transmitter; Duralink 868 MHz; for PLA-REM(-300) Transmitter; Duralink 868 MHz; for PL-REM(-60/200) Propulsion Systems bvba Dooren 72 B-1784 Belgium Date of signature: 12/01/2016 Signature: Name: Mr. Marc Lamberts Title: Managing Director page 19 of 20

Contact details Propulsion Systems bvba Dooren 72 1785 Merchtem, Belgium Tel +32 2 461 02 53 Fax +32 2 706 59 60 www.propulsionsystems.be info@propulsionsystems.be 402-0036-160914 lighting We reserve the rights to change all or part of the contents of this document without prior notice