6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

Similar documents
Product type designation. General information. Supply voltage

CPU 314C-2 PTP. Function

General information. Supply voltage

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

2A (recommended) Power loss

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet CPU 313SC (313-5BF13)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Data sheet CPU 013C (013-CCF0R00)

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

FM 355 CONTROLLER MODULE

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current

General information. CiR - Configuration in RUN

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

General information. CiR - Configuration in RUN

EXM INPUT/OUTPUT EXPANSION

General specifications and features

FM HIGH-SPEED BOOLEAN PROCESSOR

FM COUNTER MODULE

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

SIMATIC S7-300 Function modules

FM COUNTER MODULE

SM 1222 DIGITAL OUTPUT MODULE

FM COUNTER MODULE

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Zentralbaugruppen CPU 222

Analog Input Module. AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0)

SM 1223 DIGITAL INPUT/OUTPUT MODULE

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Order number 031-1BB BB BB BD30 Figure. SM 031, AI 2x12Bit I. Note - - Coming soon - Features. 2 inputs, Current 0(4)...

FM POSITIONING MODULE

SIMATIC. ET 200SP HA Analog input module AI 16xTC/ 8xRTD 2-/3-/4-wire HA (6DL1134-6JH00-0PH1) Security information 1. Product overview 2.

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

Product Information. Release 3 4 SIMATIC ET 200S. 4DI UC V High Feature Digital Electronic Module

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB52-0AB0) Preface. Properties 1. Parameters 2.

Q.raxx A slimline RS / EC Universal Measurement System

Q.raxx A101-8 slimline RS / EC

SIMATIC. ET 200S distributed I/O Analog electronic module 4AI TC ST (6ES7134-4JD00-0AB0) Preface. Properties 1. Parameters 2.

Q.raxx A slimline RS / EC

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

Analog electronic module SIMATIC. ET 200S distributed I/O Analog electronic module 2AI TC ST (6ES7134-4JB01-0AB0) Preface. Properties.

SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) Preface. Guide to documentation. Product overview.

VersaPoint I/O Module

This data sheet is only valid in association with the IL SYS INST UM E user manual.

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

SIMATIC. S7-1500/ET 200MP Analog input module AI 8xU/I/RTD/TC ST (6ES7531-7KF00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. S7-1500/ET 200MP Analog input module AI 8xU/I/RTD/TC ST (6ES7531-7KF00-0AB0) Preface. Documentation guide. Product overview.

XIOC technology and networking modules

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

VersaPoint I/O Module

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Industrial Modbus I/O Modules

GE Fanuc IC695ALG600. Rx3i PacSystem

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Analog input module. AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1) SIMATIC. ET 200SP Analog input module AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1)

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

8V General information. 2 Order data 8V

TxBlock-USB Transmitter

CompactLogix 5370 L3 Control System


SIMATIC. ET 200SP Analog Input Module AI 4xU/I 2-wire ST (6ES7134-6HD01-0BA1) Preface. Documentation guide. Product overview.

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

S7-200 SMART Programmable controller Answers for industry.

Pulse Scaler for DIN Rail Attachment

Analog Inputs and Outputs

em4 em4 alert em4 alert 2G

Temperature Input Module for Zone 1 Series 9482/32

em4 local - Robust Specific characteristics Part number

SIMATIC. S7-1500/ET 200MP Analog Input/Output Module AI 4xU/I/RTD/TC/ AQ 2xU/I ST (6ES7534-7QE00-0AB0) Preface. Guide to documentation

MULTIFUNCTION GRAPHICAL UNIT MGU 800

SIMATIC. ET 200SP Analog Input Module AI 4xI 2-/4-wire ST (6ES7134-6GD01-0BA1) Preface. Documentation guide. Product overview.

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

DEA 115, Digital Input/Output Modules

General Specifications

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Modbus communication module for TCX2: AEX-MOD

Digital Input Output Module for Zone 1 Series 9470/32

Totalizing Counters mini-i

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

Temperature Measurement

PACSystems* RX3i IC695ALG600

MODEL: DLS. Telemetering System

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

8V General information. 2 Order data 8V

Manual. VIPA System 100V EM - Expansion modules 134-4Ex. Order No.: VIPA HB100E_EM Reference: RE_134-4Ex Rev. 08/23

PACSystems* RX3i and Series 90-30

S200 I/O System Units

Arbitrary power supplies. 160 W to 5200 W

Transcription:

6ES7314-6BH04-0AB0 Page 1 Product data sheet 6ES7314-6BH04-0AB0 SIMATIC S7-300, CPU 314C-2 PTP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED INTERFACE RS485, INTEGRATED 24V DC POWER SUPPLY, 192 KBYTE WORKING MEMORY, FRONT CONNECTOR (2 X 40PIN) AND MICRO MEMORY CARD REQUIRED General information Hardware product version 01 Firmware version V3.3 Engineering with Programming package Supply voltage 24 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) External protection for supply cables (recommendation) Mains buffering Mains/voltage failure stored energy time Repeat rate, min. Digital inputs Load voltage L+ Rated value (DC) Reverse polarity protection Digital outputs Load voltage L+ Rated value (DC) STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204 19.2 V 28.8 V Miniature circuit breaker, type C; min 2 A; miniature circuit breaker type B, min. 4 A 5 ms 1 s 24 V 24 V

6ES7314-6BH04-0AB0 Page 2 Reverse polarity protection Input current Current consumption (rated value) Current consumption (in no-load operation), typ. Inrush current, typ. I²t Digital inputs from load voltage L+ (without load), max. Digital outputs from load voltage L+, max. Power losses Power loss, typ. Memory Work memory integrated expandable Size of retentive memory for retentive data blocks Load memory pluggable (MMC) pluggable (MMC), max. Data management on MMC (after last programming), min. Backup present without battery CPU processing times 660 ma 150 ma 5 A 0.7 A² s 80 ma 50 ma 13 W 192 kbyte 64 kbyte 8 Mbyte 10 a for bit operations, min. 0.06 µs for word operations, min. 0.12 µs for fixed point arithmetic, min. 0.16 µs for floating point arithmetic, min. 0.59 µs CPU-blocks Number of blocks (total) DB ; Guaranteed by MMC (maintenance-free) ; Program and data 1024 ; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

6ES7314-6BH04-0AB0 Page 3 Number, max. 1024 ; Number range: 1 to 16000 Size, max. 64 kbyte FB Number, max. 1024 ; Number range: 0 to 7999 Size, max. 64 kbyte FC Number, max. 1024 ; Number range: 0 to 7999 Size, max. 64 kbyte OB Description see instruction list Size, max. 64 kbyte Number of free cycle OBs 1 ; OB 1 Number of time alarm OBs 1 ; OB 10 Number of delay alarm OBs 2 ; OB 20, 21 Number of time interrupt OBs 4 ; OB 32, 33, 34, 35 Number of process alarm OBs 1 ; OB 40 Number of startup OBs 1 ; OB 100 Number of asynchronous error OBs 4 ; OB 80, 82, 85, 87 Number of synchronous error OBs 2 ; OB 121, 122 Nesting depth per priority class 16 additional within an error OB 4 Counters, timers and their retentivity S7 counter Number 256 Retentivity adjustable lower limit 0 upper limit 255 preset Z 0 to Z 7 Counting range lower limit 0 upper limit 999

6ES7314-6BH04-0AB0 Page 4 IEC counter present Type SFB Number Unlimited (limited only by RAM capacity) S7 times Number 256 Retentivity adjustable lower limit 0 upper limit 255 preset retentivity Time range lower limit 10 ms upper limit 9990 s IEC timer present Type SFB Number Unlimited (limited only by RAM capacity) Data areas and their retentivity retentive data area, total All, max. 64 KB Flag Number, max. 256 byte Retentivity available ; MB 0 to MB 255 Retentivity preset MB 0 to MB 15 Number of clock memories 8 ; 1 memory byte Data blocks Number, max. 1024 ; Number range: 1 to 16000 Size, max. 64 kbyte Retentivity adjustable ; via non-retain property on DB Retentivity preset Local data per priority class, max. 32 kbyte ; Max. 2048 bytes per block Address area

6ES7314-6BH04-0AB0 Page 5 I/O address area Inputs 1024 byte Outputs 1024 byte of which, distributed Inputs none Outputs none Process image Inputs 1024 byte Outputs 1024 byte Inputs, adjustable 1024 byte Outputs, adjustable 1024 byte Inputs, default 128 byte Outputs, default 128 byte Default addresses of the integrated channels Digital inputs 124.0 to 126.7 Digital outputs 124.0 to 125.7 Analog inputs 752 to 761 Analog outputs 752 to 755 Digital channels Inputs 1016 Outputs 1008 Inputs, of which central 1016 Outputs, of which central 1008 Analog channels Inputs 253 Outputs 250 Inputs, of which central 253 Outputs, of which central 250 Hardware configuration Racks, max. 4 Modules per rack, max. 8 ; In rack 3 max. 7 Expansion devices, max. 3 Number of DP masters

6ES7314-6BH04-0AB0 Page 6 integrated via CP 4 Number of operable FMs and CPs (recommended) FM 8 CP, point-to-point 8 CP, LAN 10 Time of day Clock Hardware clock (real-time clock) battery-backed and synchronizable Deviation per day, max. Backup time Behavior of the clock following POWER-ON Behavior of the clock following expiry of backup period Operating hours counter Number 1 Number/Number range 0 none 10 s ; Typ.: 2 s 6 wk ; At 40 C ambient temperature Clock continues running after POWER OFF Clock continues to run with the time at which the power failure occurred Range of values 0 to 2^31 hours (when using SFC 101) Granularity retentive Clock synchronization supported to MPI, master to MPI, slave in AS, master in AS, slave Digital inputs Number/binary inputs 24 of which, inputs usable for technological functions 16 integrated channels (DI) 24 Input characteristic curve acc. to IEC 61131, Type 1 Number of simultaneously controllable inputs horizontal installation 1 hour ; Must be restarted at each restart

6ES7314-6BH04-0AB0 Page 7 up to 40 C, max. 24 up to 60 C, max. 12 vertical installation up to 40 C, max. 12 Technological functions shielded, max. Unshielded, max. Standard DI shielded, max. Unshielded, max. Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs Parameterizable Rated value for counter/technological functions at "0" to "1", max. Cable length Cable length, shielded, max. Cable length unshielded, max. Digital outputs Number/binary outputs 16 of which high-speed outputs integrated channels (DO) 16 50 m ; at maximum count frequency not allowed 1000 m 600 m 24 V -3 to +5 V 15 to 30 V 8 ma ; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.) 3 ms 8 µs ; Minimum pulse width/minimum pause between pulses at maximum counting frequency 1000 m ; 50 m for technological functions 600 m ; For technological functions: 4 ; tice: You cannot connect the fast outputs of your CPU in parallel

6ES7314-6BH04-0AB0 Page 8 Functionality/short-circuit strength ; Clocked electronically Response threshold, typ. 1 A Limitation of inductive shutdown voltage to L+ (-48 V) Lamp load, max. 5 W Controlling a digital input Load resistance range lower limit 48 Ω upper limit 4 kω Output voltage for signal "1", min. L+ (-0.8 V) Output current for signal "1" rated value 500 ma for signal "1" permissible range, min. 5 ma for signal "1" permissible range, max. 0.6 A for signal "1" minimum load current 5 ma for signal "0" residual current, max. 0.5 ma Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. 100 Hz with inductive load, max. 0.5 Hz on lamp load, max. 100 Hz of the pulse outputs, with resistive load, max. 2.5 khz Aggregate current of outputs (per group) horizontal installation up to 40 C, max. 3 A up to 60 C, max. 2 A vertical installation up to 40 C, max. 2 A Cable length Cable length, shielded, max. 1000 m Cable length unshielded, max. 600 m

6ES7314-6BH04-0AB0 Page 9 Analog inputs Integrated channels (AI) Number of analog inputs for voltage/current measurement Number of analog inputs for resistance/resistance thermometer measurement permissible input frequency for current input (destruction limit), max. permissible input voltage for voltage input (destruction limit), max. permissible input current for voltage input (destruction limit), max. permissible input current for current input (destruction limit), max. Technical unit for temperature measurement adjustable Input ranges Voltage Current Resistance thermometer Resistance Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) Input ranges (rated values), currents 5 ; 4 x current/voltage, 1 x resistance 4 1 5 V ; Permanent 30 V ; Permanent 0.5 ma ; Permanent 50 ma ; Permanent ; Degrees Celsius / degrees Fahrenheit / Kelvin ; ±10 V / 100 kω; 0 V to 10 V / 100 kω ; ±20 ma / 100 Ω; 0 ma to 20 ma / 100 Ω; 4 ma to 20 ma / 100 Ω ; Pt 100 / 10 MΩ ; 0 Ω to 600 Ω / 10 MΩ 100 kω 0 to 20 ma Input resistance (0 to 20 ma) 100 Ω -20 to +20 ma Input resistance (-20 to +20 ma) 100 Ω 4 to 20 ma Input resistance (4 to 20 ma) Input ranges (rated values), resistance thermometers Pt 100 Input resistance (Pt 100) 100 Ω 10 MΩ

6ES7314-6BH04-0AB0 Page 10 Input ranges (rated values), resistors -Load voltage, typ. 3.3 V Measured current, typ. 1.25 ma 0 to 600 ohms Input resistance (0 to 600 ohms) 10 MΩ Thermocouple (TC) Temperature compensation Parameterizable Resistance thermometer (RTD) Characteristic linearization for resistance thermometer Pt 100 Characteristic linearization Parameterizable ; by software Cable length Cable length, shielded, max. 100 m Analog outputs Integrated channels (AO) 2 Number of analog outputs 2 Voltage output, short-circuit protection Voltage output, short-circuit current, max. 55 ma Current output, no-load voltage, max. 14 V Output ranges, voltage 0 to 10 V -10 to +10 V Output ranges, current 0 to 20 ma -20 to +20 ma 4 to 20 ma Connection of actuators for voltage output 2-conductor connection ; Without compensation of the line resistances for voltage output 4-conductor connection for current output 2-conductor connection Load impedance (in rated range of output)

6ES7314-6BH04-0AB0 Page 11 with voltage outputs, min. 1 kω with voltage outputs, capacitive load, max. 0.1 µf with current outputs, max. with current outputs, inductive load, max. 300 Ω 0.1 mh Destruction limits against externally applied voltages and currents Voltages at the outputs towards MANA Current, max. Cable length Cable length, shielded, max. Analog value creation Measurement principle Integrations and conversion time/ resolution per channel Resolution with overrange (bit including sign), max. Integration time, parameterizable permissible input frequency, max. Interference voltage suppression for interference frequency f1 in Hz Conversion time (per channel) Time constant of the input filter Basic execution time of the module (all channels released) Settling time Encoder for resistive load for capacitive load for inductive load Connection of signal encoders for voltage measurement for current measurement as 2-wire transducer for current measurement as 4-wire transducer for resistance measurement with 2-conductor connection for resistance measurement with 3-conductor connection 16 V ; Permanent 50 ma ; Permanent 200 m Actual value encryption (successive approximation) 12 bit ; 16.6 / 20 ms 400 Hz 60 / 50 Hz 1 ms 0.38 ms 1 ms 0.6 ms 1 ms 0.5 ms ; with external supply ; Without compensation of the line resistances

6ES7314-6BH04-0AB0 Page 12 for resistance measurement with 4-conductor connection Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Errors/accuracies Temperature error (relative to input area) Crosstalk between the inputs, min. Repeat accuracy in settled status at 25 C (relative to input area) Output ripple (based on output area, bandwidth 0 to 50 khz) 1.5 ma +/- 0,006 %/K 60 db +/- 0,06 % +/- 0,1 % Linearity error (relative to output area) +/- 0,15 % Temperature error (relative to output area) Crosstalk between the outputs, min. Repeat accuracy in settled status at 25 C (relative to output area) Operational limit in overall temperature range +/- 0,01 %/K 60 db +/- 0,06 % Voltage, relative to input area +/- 1 % Current, relative to input area +/- 1 % Impedance, relative to input area +/- 1 % Voltage, relative to output area +/- 1 % Current, relative to output area +/- 1 % Basic error limit (operational limit at 25 C) Voltage, relative to input area +/- 0,8 % ; Linearity error +/- 0.06 % Current, relative to input area +/- 0,8 % ; Linearity error +/- 0.06 % Impedance, relative to input area +/- 0,8 % ; Linearity error +/- 0.2% Resistance-type thermometer, relative to input area +/- 0,8 % Voltage, relative to output area +/- 0,8 % Current, relative to output area +/- 0,8 % Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency Series mode interference (peak value of interference < rated value of input range), min. 30 db

6ES7314-6BH04-0AB0 Page 13 Common mode interference, min. Interfaces Number of USB interfaces 0 Number of parallel interfaces 0 Number of 20 ma interfaces (TTY) 0 Number of RS 232 interfaces 0 Number of RS 422 interfaces Number of other hardware interfaces 0 Point-to-point Cable length, max. Integrated protocol driver 40 db 1 ; RS 422/485 combined 1200 m 3964 (R) ASCII RK512 Transmission speed, RS 422/485 1st interface with 3964 (R) protocol, max. with ASCII protocol, max. with RK 512 protocol, max. Type of interface Physics RS 485 Isolated Power supply to interface (15 to 30 V DC), max. Functionality MPI MPI DP master DP slave Point-to-point connection Services PG/OP communication 19.2 kbit/s ; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex 19.2 kbit/s ; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex 19.2 kbit/s ; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex Integrated RS 485 interface 200 ma

6ES7314-6BH04-0AB0 Page 14 Routing Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Transmission rate, max. 2nd interface Type of interface Physics Isolated Power supply to interface (15 to 30 V DC), max. Functionality MPI DP master DP slave PROFINET IO Controller PROFINET IO Device PROFINET CBA Local Operating Network Point-to-point connection Transmission rate, max. Cable length, max. interface from the user program controllable Interface can trigger alarm/interrupt in the user program ; Only server, configured on one side ; (but via CP and loadable FBs) 187.5 kbit/s Integrated RS 422/ 485 interface RS 422/RS 485 (X.27) 19.2 kbit/s ; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex 1200 m ; Message on break - identification Protocol driver 3964 (R); ASCII and RK 512 Communication functions PG/OP communication Data record routing Global data communication supported Number of GD loops, max. 8

6ES7314-6BH04-0AB0 Page 15 Number of GD packets, max. 8 Number of GD packets, transmitter, max. 8 Number of GD packets, receiver, max. 8 Size of GD packets, max. Size of GD packet (of which consistent), max. S7 basic communication supported User data per job, max. User data per job (of which consistent), max. S7 communication supported as server as client User data per job, max. User data per job (of which consistent), max. S5-compatible communication supported Number of connections overall 12 usable for PG communication 11 reserved for PG communication 1 Adjustable for PG communication, min. 1 Adjustable for PG communication, max. 11 usable for OP communication 11 reserved for OP communication 1 adjustable for OP communication, min. 1 adjustable for OP communication, max. 11 usable for S7 basic communication 8 Reserved for S7 basic communication 0 adjustable for S7 basic communication, min. 0 adjustable for S7 basic communication, max. 8 S7 message functions 22 byte 22 byte 76 byte 76 byte ; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) ; Via CP and loadable FB 180 kbyte ; With PUT/GET 240 byte ; as server ; via CP and loadable FC

6ES7314-6BH04-0AB0 Page 16 Number of login stations for message functions, max. Process diagnostic messages 12 ; Depending on the configured connections for PG/OP and S7 basic communication simultaneously active Alarm-S blocks, max. 300 Test commissioning functions Status/control Status/control variable Variables Number of variables, max. 30 of which status variables, max. 30 of which control variables, max. 14 Forcing Forcing Force, variables Number of variables, max. 10 Status block Single step Number of breakpoints 4 Diagnostic buffer present Inputs, outputs, memory bits, DB, times, counters Inputs, outputs ; Up to 2 simultaneously Number of entries, max. 500 adjustable Of which powerfail-proof Number of entries readable in RUN, max. 499 adjustable ; From 10 to 499 preset 10 Service data Can be read out Interrupts/diagnostics/status information Diagnostics indication LED Status indicator digital output (green) Status indicator digital input (green) Integrated Functions Number of counters 100 ; Only the last 100 entries are retained 4 ; See "Technological Functions" manual

6ES7314-6BH04-0AB0 Page 17 Counter frequency (counter) max. Frequency measurement Number of frequency meters controlled positioning Integrated function blocks (closed-loop control) PID controller Number of pulse outputs Limit frequency (pulse) Galvanic isolation Galvanic isolation digital inputs Galvanic isolation digital inputs between the channels between the channels and the backplane bus Galvanic isolation digital outputs Galvanic isolation digital outputs between the channels between the channels, in groups of 8 between the channels and the backplane bus Galvanic isolation analog inputs Galvanic isolation analog inputs between the channels between the channels and the backplane bus Galvanic isolation analog outputs Galvanic isolation analog outputs between the channels between the channels and the backplane bus Permissible potential difference between different circuits between inputs and MANA (UCM) between MANA and M internally (UISO) Isolation 60 khz 4 ; up to 60 khz (see "Technological Functions" manual) ; PID controller (see "Technological Functions" manual) 4 ; Pulse width modulation up to 2.5 khz (see "Technological Functions" Manual) 2.5 khz ; common for analog I/O ; common for analog I/O 75 VDC / 60 VAC 8.0 V DC 75 VDC / 60 VAC

6ES7314-6BH04-0AB0 Page 18 Isolation checked with 600 V DC Ambient conditions Operating temperature Min. 0 C max. 60 C Configuration Configuration software STEP 7 Lite programming Programming language LAD FBD STL SCL CFC GRAPH HiGraph Command set see instruction list Nesting levels 8 Software libraries System functions (SFC) see instruction list System function blocks (SFB) see instruction list Know-how protection User program protection/password protection Block encryption ; With S7 block Privacy Dimensions Width 120 mm Height 125 mm Depth 130 mm Weight Weight, approx. 680 g interntechdb Characteristics will be deleted after 2012-12-31

6ES7314-6BH04-0AB0 Page 19 Product version STEP 7 Status Feb 6, 2012 ; STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204