General information. Supply voltage

Similar documents
Product type designation. General information. Supply voltage

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

CPU 314C-2 PTP. Function

2A (recommended) Power loss

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet CPU 313SC (313-5BF13)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Data sheet CPU 013C (013-CCF0R00)

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

General information. CiR - Configuration in RUN

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current

General information. CiR - Configuration in RUN

FM 355 CONTROLLER MODULE

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

General specifications and features

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

FM HIGH-SPEED BOOLEAN PROCESSOR

EXM INPUT/OUTPUT EXPANSION

FM COUNTER MODULE

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

SIMATIC S7-300 Function modules

Analog Input Module. AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0)

FM COUNTER MODULE

Order number 031-1BB BB BB BD30 Figure. SM 031, AI 2x12Bit I. Note - - Coming soon - Features. 2 inputs, Current 0(4)...

PLC-K506 Series FEATURES DESCRIPTION FEATURES

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

SIMATIC. ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB52-0AB0) Preface. Properties 1. Parameters 2.

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

SIMATIC. ET 200SP HA Analog input module AI 16xTC/ 8xRTD 2-/3-/4-wire HA (6DL1134-6JH00-0PH1) Security information 1. Product overview 2.

Zentralbaugruppen CPU 222

SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) Preface. Guide to documentation. Product overview.

FM POSITIONING MODULE

Analog input module. AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1) SIMATIC. ET 200SP Analog input module AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1)

SIMATIC. S7-1500/ET 200MP Analog input module AI 8xU/I/RTD/TC ST (6ES7531-7KF00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200SP Analog Input Module AI 4xU/I 2-wire ST (6ES7134-6HD01-0BA1) Preface. Documentation guide. Product overview.

SM 1223 DIGITAL INPUT/OUTPUT MODULE

SM 1222 DIGITAL OUTPUT MODULE

SIMATIC. ET 200SP Analog Input Module AI 4xI 2-/4-wire ST (6ES7134-6GD01-0BA1) Preface. Documentation guide. Product overview.

Product Information. Release 3 4 SIMATIC ET 200S. 4DI UC V High Feature Digital Electronic Module

FM COUNTER MODULE

SIMATIC. S7-1500/ET 200MP Analog input module AI 8xU/I/RTD/TC ST (6ES7531-7KF00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Q.raxx A101-8 slimline RS / EC

Q.raxx A slimline RS / EC Universal Measurement System

XIOC technology and networking modules

8V General information. 2 Order data 8V

SIMATIC. ET 200S distributed I/O Analog electronic module 4AI TC ST (6ES7134-4JD00-0AB0) Preface. Properties 1. Parameters 2.

Q.raxx A slimline RS / EC

Analog electronic module SIMATIC. ET 200S distributed I/O Analog electronic module 2AI TC ST (6ES7134-4JB01-0AB0) Preface. Properties.

SIMATIC. S7-1500/ET 200MP Analog Input/Output Module AI 4xU/I/RTD/TC/ AQ 2xU/I ST (6ES7534-7QE00-0AB0) Preface. Guide to documentation

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

S7-200 SMART Programmable controller Answers for industry.

Manual. VIPA System 100V EM - Expansion modules 134-4Ex. Order No.: VIPA HB100E_EM Reference: RE_134-4Ex Rev. 08/23

Analog Inputs and Outputs

8V General information. 2 Order data 8V

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

GE Fanuc IC695ALG600. Rx3i PacSystem

VersaPoint I/O Module

EM 6000 EM 6000 DANTE True bit diversity receiver

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DEA 115, Digital Input/Output Modules

MULTIFUNCTION GRAPHICAL UNIT MGU 800

VersaPoint I/O Module

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K

CompactLogix 5370 L3 Control System

S11 Adjustable Speed Drive Engineering Specification

CP-T range Product group picture

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Industrial Modbus I/O Modules


Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

DAB+ Voice Break-In Solution

VIPA FM355 / R355 4/8-Channel Controller Module for Siemens S7-300, VIPA System 300V/S* and Decentral Peripheries

Outputs U8 I1. Protection class IP64 (IP67) WB25

Outputs U8 I1. Protection class IP64 (IP67) WB25KT

em4 em4 alert em4 alert 2G

CP-T range Benefits and advantages

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Temperature Measurement

KNX Powerline PL 110. KNX Association

Pulse Scaler for DIN Rail Attachment

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Data Acquisition Modules/ Distributed IO Modules

SE-330/SE-330AU/SE-330HV PROFIBUS-DP INTERFACE

em4 local - Robust Specific characteristics Part number

Temperature Measurement

Transcription:

Data sheet SIMATIC S7-300, CPU 314C-2 DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 192 KBYTE WORKING MEMORY, FRONT CONNECTOR (2 X 40PIN) AND MICRO MEMORY CARD REQUIRED General information Hardware product version 01 Firmware version V3.3 Engineering with Programming package STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 Supply voltage Rated value (DC) 24 V DC permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V external protection for power supply lines Miniature circuit breaker, type C; min. 2 A; miniature circuit (recommendation) breaker type B, min. 4 A Mains buffering Mains/voltage failure stored energy time 5 ms Repeat rate, min. 1 s Digital inputs Load voltage L+ Rated value (DC) 24 V Page 1/16 22.12.2015 Copyright Siemens AG

Reverse polarity protection Digital outputs Load voltage L+ Rated value (DC) 24 V Reverse polarity protection Input current Current consumption (rated value) Current consumption (in no-load operation), typ. Inrush current, typ. I²t Digital inputs from load voltage L+ (without load), max. Digital outputs from load voltage L+, max. Power loss Power loss, typ. Memory Work memory integrated expandable Size of retentive memory for retentive data blocks Load memory Plug-in (MMC) Plug-in (MMC), max. Data management on MMC (after last programming), min. Backup present without battery 880 ma 150 ma 5 A 0.7 A² s 80 ma 50 ma 13 W 192 kbyte 64 kbyte 8 Mbyte 10 y ; Guaranteed by MMC (maintenance-free) ; Program and data CPU processing times for bit operations, typ. 0.06 µs for word operations, typ. 0.12 µs for fixed point arithmetic, typ. 0.16 µs for floating point arithmetic, typ. 0.59 µs CPU-blocks Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. DB Number, max. 1 024; Number range: 1 to 16000 Size, max. 64 kbyte Page 2/16 22.12.2015 Copyright Siemens AG

FB Number, max. 1 024; Number range: 0 to 7999 Size, max. 64 kbyte FC Number, max. 1 024; Number range: 0 to 7999 Size, max. 64 kbyte OB Description see instruction list Size, max. 64 kbyte Number of free cycle OBs 1; OB 1 Number of time alarm OBs 1; OB 10 Number of delay alarm OBs 2; OB 20, 21 Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35 Number of process alarm OBs 1; OB 40 Number of DPV1 alarm OBs 3; OB 55, 56, 57 Number of startup OBs 1; OB 100 Number of asynchronous error OBs 5; OB 80, 82, 85, 86, 87 Number of synchronous error OBs 2; OB 121, 122 Nesting depth per priority class 16 additional within an error OB 4 Counters, timers and their retentivity S7 counter Number 256 Retentivity adjustable lower limit 0 upper limit 255 preset Z 0 to Z 7 Counting range lower limit 0 upper limit 999 IEC counter present Type SFB Number Unlimited (limited only by RAM capacity) S7 times Number 256 Retentivity adjustable lower limit 0 Page 3/16 22.12.2015 Copyright Siemens AG

upper limit 255 preset retentivity Time range lower limit 10 ms upper limit 9 990 s IEC timer present Type SFB Number Unlimited (limited only by RAM capacity) Data areas and their retentivity retentive data area in total All, max. 64 KB Flag Number, max. 256 byte Retentivity available ; MB 0 to MB 255 Retentivity preset MB 0 to MB 15 Number of clock memories 8; 1 memory byte Data blocks Number, max. 1 024; Number range: 1 to 16000 Size, max. 64 kbyte Retentivity adjustable ; via non-retain property on DB Retentivity preset Local data per priority class, max. 32 kbyte; Max. 2048 bytes per block Address area I/O address area Inputs 2 048 byte Outputs 2 048 byte of which distributed Inputs 2 003 byte Outputs 2 010 byte Process image Inputs 2 048 byte Outputs 2 048 byte Inputs, adjustable 2 048 byte Outputs, adjustable 2 048 byte Inputs, default 128 byte Outputs, default 128 byte Default addresses of the integrated channels Digital inputs 124.0 to 126.7 Digital outputs 124.0 to 125.7 Analog inputs 752 to 761 Page 4/16 22.12.2015 Copyright Siemens AG

Analog outputs 752 to 755 Digital channels Inputs 16 048 of which central 1 016 Outputs 16 096 of which central 1 008 Analog channels Inputs 1 006 of which central 253 Outputs 1 007 of which central 250 Hardware configuration Number of expansion units, max. 3 Number of DP masters integrated 1 via CP 4 Number of operable FMs and CPs (recommended) FM 8 CP, point-to-point 8 CP, LAN 10 Rack Racks, max. 4 Modules per rack, max. 8; In rack 3 max. 7 Time of day Clock Hardware clock (real-time clock) retentive and synchronizable Backup time 6 wk; At 40 C ambient temperature Deviation per day, max. 10 s; Typ.: 2 s Behavior of the clock following POWER-ON Clock continues running after POWER OFF Behavior of the clock following expiry of backup Clock continues to run with the time at which the power failure period occurred Operating hours counter Number 1 Number/Number range 0 Range of values 0 to 2^31 hours (when using SFC 101) Granularity 1 hour retentive ; Must be restarted at each restart Clock synchronization supported to MPI, master Page 5/16 22.12.2015 Copyright Siemens AG

to MPI, slave to DP, master to DP, slave in AS, master in AS, slave ; With DP slave only slave clock Digital inputs Number of digital inputs 24 of which inputs usable for technological functions integrated channels (DI) 24 Input characteristic curve in accordance with IEC 61131, type 1 Number of simultaneously controllable inputs horizontal installation up to 40 C, max. 24 up to 60 C, max. 12 vertical installation Input voltage up to 40 C, max. 12 Rated value (DC) 16 24 V for signal "0" -3 to +5V for signal "1" +15 to +30V Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs 8 ma parameterizable ; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that Rated value 3 ms for counter/technological functions Cable length under certain circumstances your newly set filter time may not be effective until the next filter cycle.) at "0" to "1", max. 8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency shielded, max. unshielded, max. for technological functions Digital outputs 1 000 m; 50 m for technological functions 600 m; For technological functions: shielded, max. 50 m; at maximum count frequency unshielded, max. not allowed Number of digital outputs 16 Page 6/16 22.12.2015 Copyright Siemens AG

of which high-speed outputs 4; tice: You cannot connect the fast outputs of your CPU in parallel integrated channels (DO) 16 Short-circuit protection ; Clocked electronically Response threshold, typ. 1 A Limitation of inductive shutdown voltage to L+ (-48 V) Controlling a digital input Switching capacity of the outputs on lamp load, max. 5 W Load resistance range lower limit 48 Ω upper limit 4 kω Output voltage for signal "1", min. L+ (-0.8 V) Output current for signal "1" rated value 500 ma for signal "1" permissible range, min. 5 ma for signal "1" permissible range, max. 0.6 A for signal "1" minimum load current 5 ma for signal "0" residual current, max. 0.5 ma Parallel switching of two outputs for uprating for redundant control of a load Switching frequency with resistive load, max. 100 Hz with inductive load, max. 0.5 Hz on lamp load, max. 100 Hz of the pulse outputs, with resistive load, max. 2.5 khz Total current of the outputs (per group) horizontal installation up to 40 C, max. 3 A up to 60 C, max. 2 A vertical installation up to 40 C, max. 2 A Cable length shielded, max. 1 000 m unshielded, max. 600 m Analog inputs Number of analog inputs 5 For voltage/current measurement 4 For resistance/resistance thermometer 1 measurement Page 7/16 22.12.2015 Copyright Siemens AG

integrated channels (AI) permissible input voltage for current input (destruction limit), max. permissible input voltage for voltage input (destruction limit), max. permissible input current for voltage input (destruction limit), max. permissible input current for current input (destruction limit), max. Technical unit for temperature measurement adjustable Input ranges Voltage 5; 4 x current/voltage, 1 x resistance 5 V; Permanent 30 V; Permanent 0.5 ma; Permanent 50 ma; Permanent ; Degrees Celsius / degrees Fahrenheit / Kelvin ; ±10 V / 100 kω; 0 V to 10 V / 100 kω Current ; ±20 ma / 100 Ω; 0 ma to 20 ma / 100 Ω; 4 ma to 20 ma / 100 Ω Resistance thermometer Resistance Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) Input ranges (rated values), currents 0 to 20 ma Input resistance (0 to 20 ma) -20 ma to +20 ma Input resistance (-20 ma to +20 ma) 4 ma to 20 ma Input resistance (4 ma to 20 ma) Input ranges (rated values), resistance thermometer Pt 100 Input resistance (Pt 100) Input ranges (rated values), resistors -load voltage, typ. Measuring current, typ. 0 to 600 ohms Input resistance (0 to 600 ohms) Thermocouple (TC) Temperature compensation ; Pt 100 / 10 MΩ ; 0 Ω to 600 Ω / 10 MΩ 100 kω 100 Ω 100 Ω 100 Ω 10 MΩ 3.3 V 1,25 ma parameterizable Characteristic linearization parameterizable Cable length 10 MΩ for resistance thermometer Pt 100 shielded, max. ; by software 100 m Page 8/16 22.12.2015 Copyright Siemens AG

Analog outputs Number of analog outputs 2 integrated channels (AO) 2 Voltage output, short-circuit protection Voltage output, short-circuit current, max. 55 ma Current output, no-load voltage, max. 14 V Output ranges, voltage 0 to 10 V -10 V to +10 V Output ranges, current 0 to 20 ma -20 ma to +20 ma 4 ma to 20 ma Connection of actuators for voltage output two-wire connection ; Without compensation of the line resistances for voltage output four-wire connection for current output two-wire connection Load impedance (in rated range of output) with voltage outputs, min. 1 kω with voltage outputs, capacitive load, max. 0.1 µf with current outputs, max. 300 Ω with current outputs, inductive load, max. 0.1 mh Destruction limits against externally applied voltages and currents Voltages at the outputs towards MANA 16 V; Permanent Current, max. 50 ma; Permanent Cable length shielded, max. 200 m Analog value generation Measurement principle Integration and conversion time/resolution per channel Resolution with overrange (bit including sign), max. Integration time, parameterizable permissible input frequency, max. Interference voltage suppression for interference frequency f1 in Hz Conversion time (per channel) Time constant of the input filter Basic execution time of the module (all channels released) Settling time for resistive load Actual value encryption (successive approximation) 12 bit ; 16.6 / 20 ms 400 Hz 50 / 60 Hz 1 ms 0.38 ms 1 ms 0.6 ms Page 9/16 22.12.2015 Copyright Siemens AG

for capacitive load for inductive load Encoder Connection of signal encoders for voltage measurement for current measurement as 2-wire transducer for current measurement as 4-wire transducer for resistance measurement with two-wire connection for resistance measurement with three-wire connection for resistance measurement with four-wire connection Connectable encoders 2-wire sensor permissible quiescent current (2-wire sensor), max. 1 ms 0.5 ms ; with external supply ; Without compensation of the line resistances 1.5 ma Errors/accuracies Temperature error (relative to input range), (+/-) 0.006 %/K Crosstalk between the inputs, min. 60 db Repeat accuracy in steady state at 25 C (relative to 0.06 % input area), (+/-) Output ripple (based on output area, bandwidth 0 to 0.1 % 50 khz), (+/-) Linearity error (relative to output range), (+/-) 0.15 % Temperature error (relative to output range), (+/-) 0.01 %/K Crosstalk between the outputs, min. 60 db Repeat accuracy in steady state at 25 C (relative to 0.06 % output area), (+/-) Operational error limit in overall temperature range Voltage, relative to input area, (+/-) 1 % Current, relative to input area, (+/-) 1 % Resistance, relative to input area, (+/-) 1 % Voltage, relative to output area, (+/-) 1 % Current, relative to output area, (+/-) 1 % Basic error limit (operational limit at 25 C) Voltage, relative to input area, (+/-) 0.8 %; Linearity error +/- 0.06 % Current, relative to input area, (+/-) 0.8 %; Linearity error +/- 0.06 % Resistance, relative to input area, (+/-) 0.8 %; Linearity error +/- 0.2% Resistance thermometer, relative to input area, 0.8 % (+/-) Voltage, relative to output area, (+/-) 0.8 % Page 10/16 22.12.2015 Copyright Siemens AG

Current, relative to output area, (+/-) 0.8 % Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency Series mode interference (peak value of 30 db interference < rated value of input range), min. Common mode interference, min. 40 db Interfaces Number of industrial Ethernet interfaces 0 Number of RS 485 interfaces 2; MPI and PROFIBUS DP Number of RS 422 interfaces 0 1. Interface Interface type Integrated RS 485 interface Physics RS 485 Isolated Power supply to interface (15 to 30 V DC), max. 200 ma Functionality MPI DP master DP slave Point-to-point connection MPI Transmission rate, max. 187.5 kbit/s Services PG/OP communication Routing Global data communication S7 basic communication S7 communication ; Only server, configured on one side S7 communication, as client ; but via CP and loadable FB S7 communication, as server 2. Interface Interface type Integrated RS 485 interface Physics RS 485 Isolated Power supply to interface (15 to 30 V DC), max. 200 ma Functionality MPI DP master DP slave PROFINET IO Controller PROFINET IO Device PROFINET CBA Page 11/16 22.12.2015 Copyright Siemens AG

Point-to-point connection DP master Transmission rate, max. 12 Mbit/s Number of DP slaves, max. 124 Services PG/OP communication Routing Global data communication S7 basic communication ; I blocks only S7 communication ; Only server, configured on one side S7 communication, as client S7 communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE Activation/deactivation of DP slaves Number of DP slaves that can be 8 simultaneously activated/deactivated, max. Direct data exchange (slave-to-slave ; As subscriber communication) DPV1 Address area Inputs, max. 2 kbyte Outputs, max. 2 kbyte User data per DP slave Inputs, max. 244 byte Outputs, max. 244 byte DP slave GSD file The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd) Transmission rate, max. 12 Mbit/s automatic baud rate search ; only with passive interface Address area, max. 32 User data per address area, max. 32 byte Services PG/OP communication Routing ; Only with active interface Global data communication S7 basic communication S7 communication ; Only server, configured on one side S7 communication, as client S7 communication, as server Page 12/16 22.12.2015 Copyright Siemens AG

Direct data exchange (slave-to-slave communication) DPV1 Transfer memory Inputs 244 byte Outputs 244 byte Communication functions PG/OP communication Data record routing Global data communication supported Number of GD loops, max. 8 Number of GD packets, max. 8 Number of GD packets, transmitter, max. 8 Number of GD packets, receiver, max. 8 Size of GD packets, max. 22 byte Size of GD packet (of which consistent), max. 22 byte S7 basic communication supported User data per job, max. 76 byte User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) S7 communication supported as server as client ; Via CP and loadable FB User data per job, max. 180 kbyte; With PUT/GET User data per job (of which consistent), max. 240 byte; as server S5 compatible communication supported ; via CP and loadable FC Number of connections overall 12 usable for PG communication 11 reserved for PG communication 1 adjustable for PG communication, min. 1 adjustable for PG communication, max. 11 usable for OP communication 11 reserved for OP communication 1 adjustable for OP communication, min. 1 adjustable for OP communication, max. 11 usable for S7 basic communication 8 Page 13/16 22.12.2015 Copyright Siemens AG

reserved for S7 basic communication 0 adjustable for S7 basic communication, 0 min. adjustable for S7 basic communication, 8 max. usable for routing 4; max. S7 message functions Number of login stations for message functions, max. 12; Depending on the configured connections for PG/OP and S7 basic communication Process diagnostic messages simultaneously active Alarm-S blocks, max. 300 Test commissioning functions Status block ; Up to 2 simultaneously Single step Number of breakpoints 4 Status/control Status/control variable Variables Inputs, outputs, memory bits, DB, times, counters Number of variables, max. 30 of which status variables, max. 30 of which control variables, max. 14 Forcing Forcing Forcing, variables Inputs, outputs Number of variables, max. 10 Diagnostic buffer present Number of entries, max. 500 can be set of which powerfail-proof 100; Only the last 100 entries are retained Number of entries readable in RUN, max. 499 can be set ; From 10 to 499 preset 10 Service data can be read out Interrupts/diagnostics/status information Diagnostics indication LED Status indicator digital output (green) Status indicator digital input (green) Integrated Functions Number of counters 4; See "Technological Functions" manual Page 14/16 22.12.2015 Copyright Siemens AG

Counting frequency (counter) max. Frequency measurement Number of frequency meters controlled positioning integrated function blocks (closed-loop control) PID controller Number of pulse outputs Limit frequency (pulse) 60 khz 4; up to 60 khz (see "Technological Functions" manual) ; PID controller (see "Technological Functions" manual) 4; Pulse width modulation up to 2.5 khz (see "Technological Functions" Manual) 2.5 khz Potential separation Potential separation digital inputs Potential separation digital inputs between the channels between the channels and backplane bus Potential separation digital outputs Potential separation digital outputs between the channels between the channels, in groups of 8 between the channels and backplane bus Potential separation analog inputs Potential separation analog inputs ; common for analog I/O between the channels between the channels and backplane bus Potential separation analog outputs Potential separation analog outputs ; common for analog I/O between the channels between the channels and backplane bus Permissible potential difference between different circuits Between the inputs and MANA (UCM) between MANA and M internally (UISO) Isolation Isolation tested with 75V DC/60V AC 8 V DC 75V DC/60V AC 600 V DC Ambient conditions Ambient temperature during operation min. 0 C max. 60 C Configuration Configuration software STEP 7 ; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 Page 15/16 22.12.2015 Copyright Siemens AG

STEP 7 Lite Programming Command set see instruction list Nesting levels 8 System functions (SFC) see instruction list System function blocks (SFB) see instruction list Programming language LAD FBD STL SCL CFC GRAPH HiGraph Know-how protection User program protection/password protection Block encryption ; With S7 block Privacy Dimensions Width Height Depth Weights Weight, approx. 120 mm 125 mm 130 mm 680 g last modified: 18.12.2015 Page 16/16 22.12.2015 Copyright Siemens AG