Multi-conductor Lighting Busbar System A

Similar documents
BUSBAR TRUNKING SYSTEMS 25A-63A AB-E SERIES. The smartest way of power distribution.

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range

MISTRAL SYSTEM IMPACT 2

GLS A GLS 15

Reduction - RD. Sample Order: 2000A / 1600A, Aluminium, Bolt-on, IP 55, 4 conductors KXA B - RD17. Right Side Feeder "T" Sample Order: B

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK YEARS+ Established. t. +44 (0) e.

50 YEARS+ A brand of the. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

SUPER COMPACT - SCP 6 SUPER COMPACT

SRS SEALED ROTARY SENSORS

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

SB 50 Connectors - up to 120 amps

Cable Management Solutions with DLP TM

E-LINEMV. Medium Voltage Busbar Systems.

Current clamps for AC current

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Safe and efficient power transmission in wind turbines

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

REMA FLAT BLADE CONTACT CONNECTORS SR50 SR175 SR350

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

LED Driver Linear / area fixed output

Product features and advantages

Busway Design The Easy Way. By: IIEE-ABU DHABI CHAPTER

Especially suitable for work in restricted working spaces.

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Crimping Instructions

SBS Connectors - up to 110 amps

Your passport to success TECHNICAL OVERVIEW

Marshall Tufflex. Cable Management. Steel Trunking Systems

Busbar Trunking Assembly

K Factor Power Transformers

LED Driver Compact fixed output

Current / residual current and voltage transformers. Current / residual current and voltage transformers

LED Driver Compact fixed output

Crimping Instructions

Resistance Thermometers Model Series TR7X0, Sheathed Design

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

LED Driver Compact fixed output

Datasheet - ZQ N

Powerpole Connectors - PP75: up to 120 Amps

Cablelink Plus Flush Technical

ATBTK-MF-4G. Product Classification. Mechanical Specifications. Dimensions. Regulatory Compliance/Certifications.

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Operating Manual Multi-Spot M22AL CD Stud Welding Machine

Powerpole Connectors - PP75: up to 120 Amps

HAWK5000 Operators Manual

LED Driver Linear / area fixed output

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Ford Water Meter Couplings & Accessories

Position switches FM series

LED Driver Compact fixed output. Udriver LC 15/20/25W 350/500/700/600mA fixc C SNC ESSENCE series

E-LINEMV. Medium Voltage Busbar Systems.

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

LED Driver Compact fixed output

Powerpole Connectors - PP75: up to 120 Amps

Phase and neutral overcurrent protection

LED Driver Compact fixed output

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

SBS Connectors - up to 110 amps

E-LINE INFO CABLE TRAY SYSTEMS. Technical Information Certificates General Product Specifications Weight Carriage Figures INFO.

Rotary Measurement Technology Incremental Encoders

Totally Integrated Power SIVACON 8PS LDM busbar trunking system siemens.com/ldm-system

GROUP MEGABARRE IMPACT. 800A 5000A Abu Dhabi Edition

LED control gear Linear / area fixed output

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

User s Manual. Portable Chamfering Machine

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

EPA152/252/502. User Manual.

Medium power busbar trunking

HARTING Han-Power T Solutions

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

General characteristics and technical data Series VarioPro Basic

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Automation and Network Solutions. Entertainment in Series Round Connectors by HIRSCHMANN.

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Pressure transmitter for general industrial applications Model A-10

HARTING Han GND. People Power Partnership

Miniature resistance thermometer Model TR33, thread-mounted

Automatic hardness testing devices

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set

Customer Premise. Solutions for. Solutions for Customer Premise include products ranging from wall distribution to system distribution boxes.

Article 250 Grounding & Bonding

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR


INSTRUCTION MANUAL (ATEX / IECEx)

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

1 INTRODUCTION ORDER CODE / INFORMATION

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

CONTENTS CABLE MANAGEMENT AND

The future of installation testing is here. The 1650 Series Multifunction Testers

C400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

C195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Transcription:

ISO 9001 101 ENVIRONMENTAL MANAGEMENT SYSTEMS QUALITY AND www.eae.com.tr Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 EsenyurtIstanbulTurkey Tel: +90 (212) 866 20 00 Faks: +90 (212) 886 24 20 IEC 604392 s T E ME 04 Multiconductor Lighting Busbar System A Catalogue 07Eng. / 02 1.000 pcs. 19/02/2011 ATA MATBAACILIK / A.C.E./ 612 66 EAE has full right to make any revisions or chances on this catalogue without any prior notice.

www.eae.com.tr

CONTENTS Introduction System Technical Characteristics Standard Components Special Straight Length Feeder Boxes TapOff Plugs TapOff Boxes Support Systems DL Joint Installation DL TapOff Plug Installation EC Certificate of Conformity Product Overview Project Design Form 23 4 5 67 8 910 1112 13 1415 16 17 18 19 20

General Characteristics ELine DL Busbar Trunking Systems are used in buildings with an energy requirement between AA. They are designed to feed lighting fittings due to the characteristics of the 10AA tapoff plugs. EAE Busbar Systems are manufactured using the latest production technologies available worldwide according to ISO 9001 standards with certified Quality Assurance systems. The products are designed and tested in accordance with IEC 604392. Full Isolation The busbar conductors are coated in flameproof insulation material. Total security regarding human safety is provided even when the body is severely damaged due to external heavy impacts that may occur. Tapoff Plugs Arrangement of ELine DL Busbar systems are designed with different contacts to prevent incorrect assembly. Colour Coded Covers Indicate The Phases The covers of the single phase, 10 Amp, wired tapoff plugs of the EAE DL Lighting busbar systems are designed with different colours to indicate which phase the light fittings are fed. Safety Earth contacts of the tapoff plugs make first during assembly, and the contact breaks last during disassembly. Fast, Easy and Secure Assembly Provided with single action by driving the mechanical and electrical joint silver coated springed contacts towards each other. You only need to tighten one bolt to fix the joint. Tin Coated Conductors Formation of Copper Oxide is prevented by coating the electrolytic copper conductors with full size tin. By this feature, the contact resistances are minimised. The contacts of the tapoff plugs compress the conductor within the busbar from two surfaces. 8 Plugin Points are provided on a Standard 3 m Length A total of 8 plugins on both sides of the busbar is provided as standard. 330 750 3000 750 750 420 Silver Coated Joint Contacts The contacts at the joining points of the busbar and the contacts of all tapoff units are silver coated. The silver coating minimises the contact impedances, thus preventing the overheating of the contacts in case of possible overloads. 420 750 750 750 330 2 3

System BUSBAR TYPE BUSBAR CURRENT RATING 1 CONDUCTOR CONFIGURATION BUSBAR CURRENT RATING 2 COMPONENT REFERENCES UNPAINTED / PAINTED COMPONENT DL 2 5 2 5 B S T D Busbar Type A 2 A 3 A 4 Busbar Current Rating 1 2 Conductors 2 3 Conductors 3 4 Conductors 4 5 Conductors 5 1st Conductor Configuration Standard Length STD Special Length X Feeder Box B1 End Feeder Box B2 Underfloor Feeder B1 Underfloor End Feeder B2 A 2 A 3 A 4 Busbar Current Rating 2 2 Conductors 2 3 Conductors 3 4 Conductors 4 5 Conductors 5 2nd Conductor Configuration UNPAINTED PAINTED B Paint 4

ELINEDL Technical Characteristics Rated Current Standards IEC 60439 12 DL 2424 DL 3434 DL 4444 In A Rated Insulation Voltage Rated Frequency Protection Degree Ui f IP 55 V Hz 50/60 1000 1000 1000 ShortCircuit (1 sec) Icw ka rms 2.50 3.00 4.00 ShortCircuit (Peak) Short Circuit(Peak)Tested 1 msec. Ip ka ka 4.00 21 5.00 21 6.50 21 Resistance Reactance Impedance Joule Losses At In L1, L2, L3, N (Cross Section) PE (Housing) PE (Conductor) Weight (4 Conductors) Weight (5 Conductors) R 20 X 1 Z I²R m / m m / m m / m W/m mm² mm² mm² kg/m kg/m 5.42 2.02 5.61 3.85 3.20 18.30 3.20 1. 1.50 4.46 1.62 4.47 5.24 4.00 18.30 4.00 1.43 1.55 2.90 1.27 3.17 5.65 6.00 18.30 6.00 1.60 1.72 The maximum permitted load for the support of light fittings of the system is 15 kg. concentrated or 20 kg. distributed for a recommended support span of every 2 meters without any deformation of the housing. Voltage Drop Calculation Voltage drop of a busbar system can be calculated with the following formula taking into account the load distribution constant. For single phase; U= I.2L (R.cos +X.sin ).10 For three phase ; U= 3.I.L (R.cos +X.sin ).10 3 3 V V U = Voltage Drop V I= Rated Current A L= Length of Line mt = Load Distribution Constant R = Resistance m m X = Reactance m m Load Distribution Constant Load concentrated at the end of line. Line fed from one end of the line. 1.00 Distributed load. Line fed from one end of the line. 0.50 Distributed load. Line fed from both ends of the line. 0. 5

Standard Elements 330 750 3000 750 750 420 420 750 750 750 330 CPE CPE 6

Standard Elements DL 2424 2x A Busbar 4+4 84165 DL 3434 2x A Busbar 4+4 84167 DL 4444 2x A Busbar 4+4 84169 DL 2422 2x A Busbar 4+2 84177 DL 34 2x A Busbar 4+2 84179 DL 4442 2x A Busbar 4+2 84181 DL 2222 2x A Busbar 2+2 84189 DL 2x A Busbar 2+2 84191 DL 4242 2x A Busbar 2+2 84193 DL 2x A Busbar 5+5 84201 DL 3535 2x A Busbar 5+5 84203 CPE conductor is separate. It is not connected the regular housing earth. DL 4545 2x A Busbar 5+5 84205 DL 23 2x A Busbar 5+3 84213 DL 3533 2x A Busbar 5+3 84215 CPE conductor is separate. It is not connected the regular housing earth. DL 4543 2x A Busbar 5+3 84217 DL 23 2x A Busbar 3+3 842 DL 3333 2x A Busbar 3+3 84227 CPE conductor is separate. It is not connected the regular housing earth. DL 4343 2x A Busbar 3+3 84229 The body is manufactured from 0,50 mm galvanised sheet metal as standard. For nonstandard product, please contact our technical office. 7

Special Straight Length Busbars DL 2424 2x A Special Length 4+4 84237 DL 3434 2x A Special Length 4+4 84239 DL 4444 2x A Special Length 4+4 84277 DL 2422 2x A Special Length 4+2 84249 DL 34 2x A Special Length 4+2 841 DL 4442 2x A Special Length 4+2 843 DL 2222 2x A Special Length 2+2 84261 DL 2x A Special Length 2+2 84263 DL 4242 2x A Special Length 2+2 84265 DL 2x A Special Length 5+5 84273 DL 3535 2x A Special Length 5+5 84275 CPE conductor is separate. It is not connected the regular housing earth. DL 4545 2x A Special Length 5+5 84277 DL 23 2x A Special Length 5+3 84285 DL 3533 2x A Special Length 5+3 84287 CPE conductor is separate. It is not connected the regular housing earth. DL 4543 2x A Special Length 5+3 84289 DL 23 2x A Special Length 3+3 84297 DL 3333 2x A Special Length 3+3 84299 CPE conductor is separate. It is not connected the regular housing earth. DL 4343 2x A Special Length 3+3 84301 8 The body is manufactured from 0,50 mm galvanised sheet metal as standard. For nonstandard product, please contact our technical office.

Standard Elements Feeder Box Busbars DL B1 Feeder Box DL DL 23 DL 23DL 2424 DL 2422DL 2222 84345 CPE conductor is separate. It is not connected the regular housing earth. DL 3535 B1 Feeder Box DL 3535DL 3533 DL 3333DL 3434 DL 34DL 84347 DL 4545 B1 Feeder Box DL 4545DL 4543 DL 4343DL 4444 DL 4442DL 4242 84349 158 38 Feeder Box 164 75 * With PE Conductor and M Gland as standard. End Closer is supplied together with the feeder unit. End Feeder Box Busbars DL B2 End Feeder Box DL DL 23 DL 23DL 2424 DL 2422DL 2222 84417 CPE conductor is separate. It is not connected the regular housing earth. DL 3535 B2 End Feeder Box DL 3535DL 3533 DL 3333DL 3434 DL 34DL 84419 DL 4545 B2 End Feeder Box DL 4545DL 4543 DL 4343DL 4444 DL 4442DL 4242 84421 158 38 164 * With PE Conductor and M Gland as standard. End Feeder Box Flexible Elbow Busbars DL FD Flexible Elbow DL DL 23 DL 23DL 2424 DL 2422DL 2222 84853 DL 3535 FD Flexible Elbow DL 3535DL 3533 DL 3333DL 3434 DL 34DL 84877 DL 4545 FD Flexible Elbow DL 4545DL 4543 DL 4343DL 4444 DL 4442DL 4242 84887 Flexible Elbow Max diameter of feeder cable is Ø 11 mm. The body is manufactured from 0,50 mm galvanised sheet metal as standard. For nonstandard product, please contact our technical office. 9

Standard Elements Underfloor Feeder Box (Movable Neck) Busbars 71 DL B1 Underfloor Feeder Unit DL DL 23 DL 23 DL 2424 DL 2422 DL 2222 65000 158 71 164 75 DL 3535 B1 Underfloor Feeder Unit DL 3535 DL 3533 DL 3333 DL 3434 DL 34 DL 65004 Feeder Box CPE conductor is separate. It is not connected the regular housing earth. DL 4545 B1 Underfloor Feeder Unit * With PE Conductor and M Gland as standard. End Closer is supplied together with the feeder unit. DL 4545 DL 4543 DL 4343 DL 4444 DL 4442 DL 4242 65008 Underfloor End Feeder Box (Movable Neck) Busbars 71 DL B2 Underfloor End Feeder Unit DL DL 23 DL 23 DL 2424 DL 2422 DL 2222 65009 158 71 164 DL 3535 B2 Underfloor End Feeder Unit DL 3535 DL 3533 DL 3333 DL 3434 DL 34 DL 65013 End Feeder Box CPE conductor is separate. It is not connected the regular housing earth. DL 4545 B2 Underfloor End Feeder Unit * With PE Conductor and M Gland as standard. DL 4545 DL 4543 DL 4343 DL 4444 DL 4442 DL 4242 65017 10 Max diameter of feeder cable is Ø 11 mm. The body is manufactured from 0,50 mm galvanised sheet metal as standard. For nonstandard product, please contact our technical office.

Tap Off Plugs Cable Length Phase Properties DL 10 B Ta p O f f P l u g L1* 1m.TTRCable L1,N,PE With Black Cover 84453 10 DL 10 B Ta p O f f P l u g L2* 1m.TTRCable L2,N,PE With Yellow Cover 84455 DL 10 B Ta p O f f P l u g L3* 1m.TTRCable L3,N,PE With Blue Cover 84457 * Plugs with different length cable available upon request. 105 66,5 69,5 DL 10 B Cable Length Phase Properties 16 DL 16 FS DL 16 FS DL 16 FS DL 16 FS Ta p O f f P l u g L1 Ta p O f f P l u g L2 Ta p O f f P l u g L3 Ta p O f f P l u g L123 L1,N,PE L2,N,PE L3,N,PE L1,L2,L3,N,PE With 5 x 20 fuse holders. Max diameter of feeder cable is Ø 11 mm. 84465 84467 84469 84479 16 DL 16 K DL 16 K DL 16 K DL 16 K Ta p O f f P l u g L1 Ta p O f f P l u g L2 Ta p O f f P l u g L3 Ta p O f f P l u g L123 L1,N,PE L2,N,PE L3,N,PE L1,L2,L3,N,PE Without Fuses. Max diameter of feeder cable is Ø 11 mm. 75013 75011 75003 75001 105 66,5 69,5 DL 16 FS DL 16 K 11

Tap off Plugs (Clean Earth) Tap off Plugs (CPE) Cable Length Phase Properties 10 DL 10 B CPE Ta p O f f P l u g L1* DL 10 B CPE Ta p O f f P l u g L2* DL 10 B CPE Ta p O f f P l u g L3* 1m.TTRCable 1m.TTRCable 1m.TTRCable L1,N,CPE L2,N,CPE L3,N,CPE With Black Cover With Yellow Cover With Blue Cover 80002 80010 80024 * Plugs with different length cable available upon request. 105 66,5 69,5 DL 10 B CPE Plug with Fuse Holder / Plug with Clips (CPE) Cable Length Phase Properties 16 DL16FSCPE Ta p O f f P l u g L1 DL16FSCPE Ta p O f f P l u g L2 DL16FSCPE Ta p O f f P l u g L3 DL 16 FS CPE Ta p O f f P l u g L123 L1,N,CPE L2, N, CPE L3, N, CPE L1, L2, L3, N, CPE With 5 x 20 fuse holders. Max diameter of feeder cable is Ø 11 mm. 84493 83459 83457 83447 16 DL 16 K CPE DL 16 K CPE DL 16 K CPE DL 16 K CPE Ta p O f f P l u g L1 Ta p O f f P l u g L2 Ta p O f f P l u g L3 Ta p O f f P l u g L123 L1,N,CPE L2,N,CPE L3,N,CPE L1,L2,L3,N,CPE Without Fuses. Max diameter of feeder cable is Ø 11 mm. 67352 67351 67350 67349 DL 16 FS CPE DL 16 K CPE 105 69,5 66,5 12

Top Off Boxes Tap Off Box Phase Properties DL S Empty Tap Off Box (CPE)* DL S Empty Tap Off Box (PE) DL S Empty Tap Off Box (2N) L1,L2,L3,N,CPE L1,L2,L3,N,PE L1, L2, L3, 2N 5 x 38 fuse holders. Max diameter of feeder cable is Ø 20 mm. 60026 60027 60028 * Tap off box can be fitted with MCB s of different ratings and brands. 228 1 90 113 DL S 13

Fixing KA TPU Fixing unit U type 98699 ø 7,5 55 20 DL Fixing Unit 735 92 DLTP 56 19 14

Fixing KA TP Lighting fixture fixing unit 98698 ø 9 95 ø 12 35 KATPL Fixing unit L type 985 80 ø 7,5 37 30 15

Busbar Joint Installation 1 2 1a Detach the protective plastic from both ends of the channel. (1a) Remove the plastic protective covers from the system as shown in the figure. 3 4 CLICK 3a Connect the male side of the channel with the female side of the other channel. Make sure that you hear the locking sound for correct connection. (3a) Complete the joint assembly by tightening the joint bolt. (4a) 16

DL Tap Off Plug Fixing 1 Turn the locking button on the busbar to OPEN ( ) position (Figure 1). 2 2a Turn the locking knob to OPEN ( )position. Clips are open now. Insert the plug while aligning contacts correctly to the busbar (Figure 2 & 3). 3 4 After fixing the plug to the busbar properly, turn the locking knob to LOCK ( ) position as shown on (Figure 4). 4a 4b 17

Directive EC DECLARATION OF CONFORMITY According to EC Directive 2006/95/EEC Low Voltage Directive Product Group ELine DL Busbar Energy Distribution System Manufacturer EAE Elektrik Asansor End. Insaat San. ve Tic. A.S. Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 EsenyurtIstanbul This is to attest, under our sole responsibility, that the aforementioned products conforms with the regulations and guidelines of the following standards. Standar d : IEC 604391 IEC 604392 Type Tests 1 Temperature Rise 7 Protection Class 2 Dielectric Characteristics 3 Short Circuit Resistance 4 Continuity of the Protective Circuit 5 Creepage Distances 6 Mechanical Operation 8 Electrical Characteristics 9 Structural Strength E L E K10 Crush T Strength R İ K 11 Insulation Material Thermal Strength Date EAE Elektrik A.S. 09 January 2008 18 EAE Elektrik Asansor End. Insaat San. ve Tic. A.S. Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 EsenyurtIstanbulTurkey Tel: +90 (212) 866 20 00 Fax: +90 (212) 886 24 20 http://www.eae.com.tr

Product Overview A PLUGIN BUSBAR SYSTEMS PRODUCT SPECIFICATION (ELine DL) 1 2 3 4 5 The manufacturer of the busbar systems shall have ISO 9001 and ISO 101 certification and busbar systems shall be type tested and certified according to IEC 604392 by international laboratories. The rated insulation voltage of the system shall be 1000V. The busbar sytem shall have rated current levels between A and A and shall have tin plated copper conductors The conductors in the housing shall be continuously insulated and only peeled off at the plugin points to create contact area. The busbar system shall conform to the following phase configuration. a) 2 Conductors : L1 / N / Housing (Earthing) b) 3 Conductors : L1 / N / CPE +Housing (PE conductor and housing are not connected) c) 4 Conductors : L1 / L2 / L3 / N / Housing (Earthing) d) 5 Conductors : L1 / L2 / L3 / N / CPE + Housing (PE conductor and housing are not connected) Housing shall be used as earth conductor. 6 7 8 A total of 8 plugin points on the standard 3 m length of the busbar system. It shall be possible to increase the number of windows on request. Protective covers shall be provided on plugin windows. There shall be insulator supports at the plugin points The conductors shall be of electrolytic copper and continuously tin plated 9 10 IP Protection degree of the busbars shall be 55 11 12 13 Joint of the busbar shall slide into each other; joint contacts shall be silver plated. To ensure a safe joint contact there shall be springs on both sides of joint contacts. The housing of the busbar shall be manufactured of 0,50 mm thick galvanised sheet metal. It shall be possible for the manufacturer to produce in Ral 7038 coloured electrostatic ovendried paint finish when requested. Contacts in the tap offs shall be of the jawed construction, which contact the conductors on both sides. The contacts shall also have steel springs. Standard support fittings and fixing components suitable for the external structure of the busbar system shall be provided and shall be produced by the manufacturer. 19

Project Design Form Please dublicate this page for your own use. Item Company : Project : Project No : Name : Date : Signature : Component List Component Quantity Prepared by 20