Compliance with CE Marking, UL Standard and CSA Standard

Similar documents
EMC Installation Guidelines

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

50W Constant Current (700mA) Dimming LED Driver

75W Constant Current (700mA) LED Driver

CHAPTER 3 WIRING DANGER

Subject to changes 11/2003 Page 1/7

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Appendix A: Specifications

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

KOLLMORGEN. Motion Technologies Group. EMC Installation and Application Guidelines for BDS4/5 Goldline Series MB4000H Issue 3

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

EMI Installation Guidelines

VF-nC1 Adjustable Speed Drive Engineering Specification

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Electromagnetic Compatibility

Three-phase monitoring relay CM-PFS

Zelio Control Measurement Relays

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relay

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

MINI MCR-SL-UI-I-LP-NC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Single Phase Soft Starters

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

BIODEX MULTI- JOINT SYSTEM

High precision measurement system for current and voltage IHC-A/B-RM01/03

Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

Max. Output Power. Efficiency (1) 110Vac 220Vac

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Liquid level monitoring relay CM-ENS.2x

Max. Output Power. Efficiency (1) 110Vac 220Vac

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

z47524 PXI Quad SPDT RF Changeover Switch Module

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Efficiency (1) 110Vac 220Vac. 350 ma 90 ~ 305 Vac 274 Vdc 96 W 92.0% EUC-096S035ST(7) EUC-096S035DT(7)

Powered Traction Unit OPERATION MANUAL

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Typical Efficiency (1) 2080 ma 90 ~ 305 Vac 4~12 Vdc 25 W 80% EUC-025S208DS(PS)(6)

02/11/2015

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

ESwitch. User Guide. Power Contactor

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Typical Efficiency (2)

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

Solid-state Timer H3DS

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST)(4)

Industrial, 2-Pole ZS Type RA2A

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Electronic timer CT-SDS.22

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

NI PXI-2520 Specifications 80-Channel SPST Relay Module

Solid-State Soft Starters

HEC-45LTN-45PFAS Rev A

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

CP-T range Product group picture

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

English

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 60~120Vdc 42 W 90.0% EUC-042S035DS(PS)(4)

Power Factor (1) Efficiency (1)

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Electronic fan speed regulators

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

AC Motor Drives EMC Standard Installation Guide EMC Compliance Practice

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 38~75 Vdc 26 W 86% EUC-026S035DS(PS)(4)(8)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

CP-E range Benefits and advantages

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Transcription:

INVERTER INSTRUCTION MANUAL Compliance with CE Marking, UL Standard and CSA Standard VF-nC1 Single-phase 100V VF-nC1 Single-phase 200V VF-nC1 Three-phase 200V NOTICE 1. Make sure that this Instruction Manual is delivered to the end user of the inverter unit. 2. Keep this manual before installing or operating the inverter unit, and store it in a safe place for reference. Toshiba Schneider Inverter Corporation 2003 All Rights Reserved.

INDEX 1. Compliance with CE Marking...2 1.1. Abstract...2 1.2. EMC directive...3 1.3. Compliance with EMC directive...4 1.4. Low voltage directive...9 1.5. Compliance with Low voltage directive...10 2. Compliance with UL Standard and CSA Standard... 11 2.1. Compliance with Installation... 11 2.2. Compliance with Connection... 11 2.3. Compliance with Peripheral devices... 11 2.4. Motor thermal protection... 11-1 -

1. Compliance with CE Marking 1.1. Abstract In Europe, EMC directive is enforced starting 1 st Jan. of 1996, and Low Voltage Directive starting 1 st Jan. of 1997. The display of CE mark that demonstrates that products imported to European Union conform to these directives is required. Inverter itself cannot function alone, but is de-signed as a component in order to control machines or equipment which includes that inverter installed in a cubicle. Therefore the conformance to EMC directive is not required on inverter it-self. But since the object of the Low Voltage directive is equipment that is designed to be used with rated voltage of 50 to 1,000 VAC or 75 to 1,500 VDC, CE should be marked on inverter as to the Low Voltage directive. But CE has to be marked on the final product installing inverters, that conforms to the EMC directive and the Low Voltage directive. And the product also may conform to Machine directive. The user that makes the final products have to take the responsibility for Marking of CE. For that reason, we recommend installation for Low Voltage directive and measurement for EMC directive, so that the products including our inverter should conform to the EMC and Low Voltage directive. TOSHIBA carried out Approval testing and confirmation testing on representative models under the circumstances based on installation and measurement so that our products should conform to each directive. But we cannot confirm the conformance of the user s products to the EMC directive. Since EMC environment changes according to the construction of the cubicle and the relation of other installed electric equipment and the condition of wiring and installation, please confirm the conformance to the EMC directive for the final products on your side. - 2 -

1.2. EMC directive An inverter itself is not an object of CE marking. A machine which consists of an inverter and a motor is an object of CE marking. The EMC directive includes the emission section and the immunity section. VF-nC1 can conform to EMC directive by means of installing the recommended EMI noise filter to the input side, and wiring properly. -> Emission: Emission of electromagnetic wave and electromagnetic interference -> Immunity: Resistance to electromagnetic interference [EMC directive] 89/336/EEC Table 1 Relative standard Noise type Test item Standard Applicable standards Emission Conducted Emission EN55011 Group 1 class A Radiated Emission EN55011 Group 1 class A Electrostatic Discharge IEC61000-4-2 EN61800-3 Radiated Electromagnetic field IEC61000-4-3 Immunity Electrical Fast Transient/Burst IEC61000-4-4 Surge Immunity IEC61000-4-5 Conducted Disturbances IEC61000-4-6 Voltage dips, short interruptions IEC61000-4-11 and voltage variations - 3 -

1.3. Compliance with EMC directive 1.3.1 The model, noise filter inside (1) Single-phase 200V class : VFNC1S-2002PL to 2022PL The above mentioned models install EMI noise filter inside. So the conducted and radiated noise can be reduced, optional EMI noise filters are not needed. (The additional noise filter should be installed, when more effective reduction is required.) (2) The main cables such as input to the EMI filter and output of the inverter and the signal cables should be shielded, then cable length should be wired as short as possible. The main input cable should be separated from the main output cable, and cables for control signal also should be separated from main cables, not wiring parallel and not bundling, cross the wires where necessary. (3) Install EMI filter and inverter on the same metal back plate in an inverter panel. The metal back plate or the cubicle must be grounded absolutely, by using short thick wires, separated from the main cables. (4) Shielded cables should be grounded on the metal back plate in order to reduce the radiated noise from the other cables. It is an effective measure that shielded cables are grounded close to the inverter or/and operation panel or/and EMI filter(less than 10cm). (5) Installation of the zero-phase and/or the ferrite core can also effectively reduce the radiated noise further.(input or/and output of inverter) - 4 -

[Ex. Countermeasure - main circuit wiring] Connect to the power source Inverter panel (Metal) Shielded cables Connect to the control Grounding plate Separate input and output cables. Do not run input cables along-side output cables. Do not bundle input and output cables. IM Fig. 1 Shielded cable Strip the cable and fix it to the metal plate by means of a metal saddle for electrical work or equivalent. - 5 -

1.3.2 The models without EMI filters (1) Shingle-phase 100V class : VFNC1-1001P to 1007P Three-phase 200V class : VFNC1-2001P to 2022P Shingle-phase 200V class : VFNC1S-2002P to 2022P This subsection explains what measures must be taken to satisfy the EMC directive. Insert a recommended EMI filter (Table 2) on the input side of the inverter to reduce radiation and transmission noises. In the combinations listed in Table 2, inverters were checked for conformity with the EMC directive. For inverters used in Japan, it is recommended to use the NF series of noise filters. Table 2 lists noise filters recommended for the inverters. Table 2. Recommended EMI filter selection Voltage class Inverter Filter for class A Compliance Motor cable length 20m or less Filter for class B Compliance Motor cable length 5m or less Three-phase VFNC1-2001P EMFA2006Z - 200V class VFNC1-2002P EMFA2006Z - VFNC1-2004P EMFA2006Z - VFNC1-2007P EMFA2006Z - VFNC1-2015P EMFA2015Z - VFNC1-2022P EMFA2015Z - Single-phase VFNC1S-2002P EMFAS2011Z - 200V class VFNC1S-2004P EMFAS2011Z - VFNC1S-2007P EMFAS2011Z - VFNC1S-2015P EMFAS2025Z - VFNC1S-2022P EMFAS2025Z - Single-phase VFNC1S-1001P EMFAS2011Z - 100V class VFNC1S-1002P EMFAS2011Z - VFNC1S-1004P EMFAS2011Z - VFNC1S-1007P EMFAS2025Z - Single-phase VFNC1S-2002PL With a built-in filter With a built-in filter 200V class VFNC1S-2004PL With a built-in filter With a built-in filter (Built-in filter type) VFNC1S-2007PL With a built-in filter With a built-in filter VFNC1S-2015PL With a built-in filter With a built-in filter VFNC1S-2022PL With a built-in filter With a built-in filter (2) The main cables such as input to the EMI filter and output of the inverter and the signal cables should be shielded, then cable length should be wired as short as possible. The main input cable should be separated from the main output cable, and cables for control signal also should be separated from main cables, not wiring parallel and not bundling, cross the wires where necessary. (3) Install EMI filter and inverter on the same metal back plate in an inverter panel. The metal back plate or the cubicle must be grounded absolutely, by using short thick wires, separated from the main cables. (4) Please separate input cable to EMI filter from output cable as much as possible. - 6 -

(5) Shielded cables should be grounded on the metal back plate in order to reduce the radiated noise from the other cables. It is an effective measure that shielded cables are grounded close to the inverter or/and operation panel or/and EMI filter(less than 10cm). (6) Installation of the zero-phase and/or the ferrite core can also effectively reduce the radiated noise further. (Input or/and output of inverter) [Ex. Countermeasure - main circuit wiring] EMI filter Inverter panel (Metal) Shielded cables Connect to the control Grounding plate Separate input and output cables. Do not run input cables along-side output cables. Do not bundle input and output cables. Connect to the power source IM Fig. 2-7 -

Note 1) Process as shown below. Shielded cable Strip the coating of the cable and fix the shielded part to the metal plate using a metal fitting. Fig. 3 [Operating with external signals] To operate with external signals, process as following figures. Ferrite core 1 Control circuit terminal P5 VI/S3 CC F R NOTE1) Shielded cable Potentiometer Forward Reverse [Accessories for countermeasure] Fig. 4 - Shielded cable : Showa electric Wire & Cable Co. LTD. Type form/ CV-S, 600V or less - Shielded cable : SUMITOMO 3M Co. Ltd. Electro-magnetic guard shielded sleeve Type form/ DS-5,7,10,14 - EMI filter : Toshiba Schneider Inverter Corporation Type form/ For further details, see Table2 - Ferrite core 1 : TDK Co. Ltd. Type form/ ZCAT3035-1330 [Apply if needed] - Grounding plate : Toshiba Schneider Inverter Corporation Type form/ EMP001Z - Ferrite core : NEC TOKIN Corporation Type form/ ESD-R-47D-1 - Zero-phase reactor : Soshin denki Co. Ltd. Type form/ RC5078 or RC9129 - Radio noise filter : Soshin denki Co. Ltd. Type form/ NF series - 8 -

1.4. Low voltage directive Inverter itself is an object of the CE marking. The Low Voltage Directive defines the safety of the electric equipment. VF-A7 series conform to the Low Voltage directive based on EN50178. Normative standard : EN50178/Electronic equipment for use in power installation Pollution degree :2(5.2.15.2) Over-voltage category : 3 200V class 3.0 mm (5.2.16.1) EN50178 provides that for electronic equipment used in power installations. The main intention is to stipulate minimum requirements for the design and manufacture of electronic equipment, for protection against electric shock, for testing and for the integration into systems for power installations. - 9 -

1.5. Compliance with Low voltage directive E6581154 Please carry out the below mentioned countermeasures for the Low Voltage Directive in case of using VF-NC1 as components of your products. (1) Inverter should be installed in a panel. Pay attention to wiring openings, so that it should prevent someone from touching live parts through the opening in case of maintenance. 2) No more than 1 cable should be connected to one earth terminal of the main terminal board. In this case, other cables for ground should be grounded on the metal back plate and/or in the cubicle. The cross-sectional area of grounding cable shall be, in any case, not less than; Voltage class Single-phase 100V class Single-phase 200V class Three-phase 200V class Capacity of applicable motor (kw) Table 3. Grounding cable Inverter model Wire size Grounding cable (mm 2 ) 0.1 VFNC1S-1001P 3.5 0.2 VFNC1S-1002P 3.5 0.4 VFNC1S-1004P 3.5 0.75 VFNC1S-1007P 3.5 0.2 VFNC1S-2002P(L) 3.5 0.4 VFNC1S-2004P(L) 3.5 0.75 VFNC1S-2007P(L) 3.5 1.5 VFNC1S-2015P(L) 3.5 2.2 VFNC1S-2022P(L) 5.5 0.1 VFNC1-2001P 3.5 0.2 VFNC1-2002P 3.5 0.4 VFNC1-2004P 3.5 0.75 VFNC1-2007P 3.5 1.5 VFNC1-2015P 3.5 2.2 VFNC1-2022P 3.5 (3) MCCB or fuse should be connected to the input side of the EMI filter. - 10 -

2. Compliance with UL Standard and CSA Standard E6581154 The VF-NC1 models, that conform to the UL Standard and CSA Standard have the UL/CSA mark on the nameplate. 2.1. Compliance with Installation The VF-NC1 inverter must be installed in a panel, and used within the ambient temperature specification. They can be used at ambient temperature of up to 50 degrees by peeling off the label on the top of the inverter. 2.2. Compliance with Connection Use the UL conformed cables (Rating 75degrees or more) with the ring terminal at wiring to the inverter input/ output terminals (R/L1, S/L2, T/L3, U/T1, V/T2, W/T3). 2.3. Compliance with Peripheral devices Use the UL listed fuses at connecting to power supply. Refer to the instruction manual about selecting the rating of them. Short circuit test is performed under the condition of the power supply short-circuit currents in below. These currents and fuse currents depend on the applicable motor capacities. Table 4. AIC and fuse Voltage class Singlephase 100V class Singlephase 200V class Threephase 200V class Capacity of applicable motor (kw) Inverter model AIC (Interrupting capacity) Fuse class and currents (A) 0.1 VFNC1S-1001P AIC 1000A CC/J 6 max 0.2 VFNC1S-1002P AIC 1000A CC/J 8 max 0.4 VFNC1S-1004P AIC 1000A CC/J 12 max 0.75 VFNC1S-1007P AIC 1000A CC/J 22 max 0.2 VFNC1S-2002P(L) AIC 1000A CC/J 4 max 0.4 VFNC1S-2004P(L) AIC 1000A CC/J 8 max 0.75 VFNC1S-2007P(L) AIC 1000A CC/J 12 max 1.5 VFNC1S-2015P(L) AIC 5000A CC/J 22 max 2.2 VFNC1S-2022P(L) AIC 5000A CC/J 30 max 0.1 VFNC1-2001P AIC 1000A CC/J 3 max 0.2 VFNC1-2002P AIC 1000A CC/J 3 max 0.4 VFNC1-2004P AIC 1000A CC/J 5 max 0.75 VFNC1-2007P AIC 1000A CC/J 8 max 1.5 VFNC1-2015P AIC 5000A CC/J 15 max 2.2 VFNC1-2022P AIC 5000A CC/J 20 max 2.4. Motor thermal protection Selects the electronic thermal protection characteristics that fit with the ratings and characteristics of the motor. In case of multi motor operation with one inverter, thermal relay should be connected to each motor. - 11 -