Wide-band Models from DC to 100 MHz

Similar documents
Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz

User s Manual Current Probe. IM E 2nd Edition IM E

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

World-Class Accuracy & Measurement Range (40 Conventional Models)

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

INSTRUCTION MANUAL CLAMP ON PROBE

AC/DC current clamps (1/2) E N series

User s Manual Current Probe IM E. 8th Edition

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

User s Manual Current Probe IM E. 6th Edition

TT-SI MHz Active Differential Probe

TT-SI 9001 / TT-SI MHz Active Differential Probes

Flexible AC current probes

E Series 9.00 (1/2) E series

FLEXIBLE CURRENT PROBES

DIGITAL HiTESTER 3237, 3238, 3239

99 Washington Street Melrose, MA Phone Toll Free Visit us at

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

AC/DC Current Oscilloscope Probe Model SL261

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

Accurately measure devices up to 1000 V/65 A AC/DC with direct input

3331, 3332 POWER HiTESTER

TT-SI MHz Active Differential Probe

High-accuracy measurement of standby to operating power

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

High-accuracy measurement of standby to operating power

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

AC/DC CLAMP METER CM4371, CM4373

The PW3336 (2-channel) and PW3337 (3-channel) can measure DC and a variety of power connections ranging from single-phase 2-wire to 3-phase 4-wire*.

TT-SI MHz DIFFERENTIAL PROBE


STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

AC/DC Current Probe TCP0150 Datasheet

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

High-precision portable RESISTANCE METER

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

10.00 (1/2) PAC series

RP1003C/RP1004C/RP1005C

Wide Spectrum Power Meter for Comprehensive Device Assessment

5MHz FUNCTION GENERATOR

Current clamps for AC current

Current clamps for AC current

Rugged, Professional and Ready for the Field. Capture high- to low-voltage signals in a single device. MEMORY HiCORDER MR8880

INSULATION TESTER SERIES Selection guide

An Evolution in Stable Measurements

Agilent 1146A AC/DC Oscilloscope Current Probe

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

99 Washington Street Melrose, MA Phone Toll Free Visit us at

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

Rugged, Professional and Ready for the Field. Capture high- to low-voltage signals in a single device. MEMORY HiCORDER MR8880

Fluke 3540 FC Three-Phase Power Monitor

NOTE: Fully read and understand this manual before using this Digital Multimeter.

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

1587/1577 Insulation Multimeters

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.

DS10000ULFS-10V/10kA

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

For easy-to-use loggers, look no further! WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515

AC/DC CLAMP METER CM4370 series

POWER HiTESTER 3331, 3332

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

Agilent 1147A 50 MHz Current Probe

CLAMP ON HiTESTER SERIES

High precision measurement system for current and voltage IHC-A/B-RM01/03

Agilent N2893A 100 MHz Current Probe

MD 200A High voltage differential probe

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

1. BP4620 SPECIFICATIONS

AC/DC CLAMP METER CM4370 series

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

Keysight 1147B 50 MHz Current Probe. User s Guide

Fluke 3540 FC Three-Phase Power Monitor

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

DECLARATION OF CONFORMITY

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

15. Specifications WF1947/WF

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DM-5 Power Quality Analyzer

User Manual Current Probe Instruction Manual

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

AC/DC CLAMP METER AC CLAMP METER CM4000 series

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER DSM-8104, DSM-8542

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Offering a new approach to energyrelated

Arbitrary/Function Generator AFG1000 Series Datasheet

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Transcription:

CLAMP ON PROBE 327 series AC/DC CURRENT SENSOR CT686 series 99 Washington Street Melrose, MA 2176 Phone 781-665-14 Toll Free 1-8-517-8431 Visit us at www.testequipmentdepot.com Wide-band Models from DC to MHz CLAMP ON PROBE 3276

2 CLAMP ON PROBE 3273-5 to 3276 Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due to breaks in the electrical path. The 3273-5 - 3276 CLAMP ON PROBEs only need to be connected directly into the BNC input on waveform observation equipment such as an oscilloscope or a recorder. Then simply clamp onto the conductor to be measured to easily observe current waveforms under a wide bandwidth and high sensitivity conditions. Important Characteristics 3273-5 Square wave response DC to 5 MHz Transient response 3273-5 Low-current measurement Input: 1 khz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) 1. Frequency response Amplitude [db, db=1v] Input: 1 MHz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) 3 25 2 15 1 5 1 Input: map-p (Oscilloscope bandwidth 4 MHz) 2. Continuous maximum input rating (Frequency derating) Maximum input current [Arms] 1k 1k k 1M 1M M Input: 1 khz sine wave 1 map-p 3. Input impedance Input impedance [Ω] 3276 DC to MHz 3276 Square wave response Transient response Low-current measurement Input: 1 khz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) Input: 1 MHz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) Input: map-p (Oscilloscope bandwidth 4 MHz) Input: 1 khz sine wave 1 map-p 1. Frequency response 2. Continuous maximum input rating (Frequency derating) 3. Input impedance Amplitude [db, db=1v] Maximum input current [Arms] 3 25 2 15 1 5 1 1k 1k k 1M 1M M Input impedance [Ω]

CLAMP ON PROBE 3273-5 to 3276 3 High S/N ratio: ideal for measuring milliampere waveforms (Model 3273-5) Capable of waveform monitoring from wide band and minute currents to large currents (Model 3274) Permits waveform observation of large current of up to 5 Arms (Model 3275) Wide-band waveform observations, from DC to MHz (Model 3276) Direct connection to BNC input of oscilloscope Highly accurate current detection Newly developed indium-antimony (InSb) thin-film Hall element Simple overload protector prevents damage due to overheating Easy measurement Features The 3273-5 includes a soft case, the 3274 / 3275 /3276 includes a hard carrying case Waveform Example Automobile Starter Current A/div 1 s/div Lighting Inverter 2 ma/div 2 μs/div Press Machine Load Current 5 A/div 1 ms/div 3274 DC to 1 MHz 3274 Square wave response Transient response Low-current measurement Input: Hz square wave 2 Ap-p (Oscilloscope bandwidth MHz) 1. Frequency response Input: khz square wave 4 map-p (Oscilloscope bandwidth MHz) Input: 1 Ap-p (Oscilloscope bandwidth MHz) 2. Continuous maximum input rating (Frequency Derating) Input: 1 khz sine wave 5 map-p (Oscilloscope bandwidth MHz) 3. Input impedance Amplitude [db, db=1v] 3275 Square wave response Transient response Low-current measurement Input: Hz square wave 3 Ap-p Input: 1 khz square wave 4 map-p Input: 1 Ap-p Input: 1 khz sine wave 5 map-p 1. Frequency response 2. Continuous maximum input rating (Frequency Derating) 3. Input impedance Amplitude [db, db=1v] Maximum input current [Arms] Input impedance [Ω] Maximum input current [Arms] Input impedance [Ω] 1 m 1m 1m DC to 2 MHz 3275

4 CLAMP ON PROBE 3273-5 to 3276 3273-5 / 3276 Specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months) 3273-5 Frequency bandwidth DC to 5 MHz (-3 db) * See Fig. 1 on page 1. Rise time Continuous maximum input range Maximum peak current value Output voltage rate 7 ns or less 3 Arms * Frequency derating see Fig. 2 on page 1. Non-continuous 5 Apeak.1 V/A Amplitude accuracy ±1.% rdg. ±1 mv ( to 3 Arms / DC, 45 to 66 Hz) ±2.% rdg. (3 Arms to 5 Apeak / DC, 45 to 66 Hz) Noise 2.5 marms or less (measured with 2 MHz bandwidth equipment) Input impedance * See Fig. 3 on page 1. Sensitivity temperature Maximum rated power Operating temperature and humidity Storage temperature and humidity Effect of external magnetic fields Within ±2% (At 5 Hz/3 Arms input, to 4 C [32 to 14 F]) 5.6 VA (Input within the maximum input range.) Power supply voltage ±12 V ±.5 V to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 2 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) Max. rated voltage to earth 3 V, CAT-I (insulated conductor) Measurement conductor Diameter max. 5 mm [.2"] Sensor: approx. 175(W) 18(H) 4(D) mm; 23 g Dimensions and mass [6.89"(W).71"(H) 1.57"(D), 8.1 oz.] Termination unit: approx. 27(W) 55(H) 18(D) mm [1.6"(W) 2.17"(H).71"(D)] Cable length Sensor cable: approx. 1.5 m [59.6"] (BNC connector) Power cable: approx. 1 m [39.37"] Supplied accessories Soft case 1 Applicable standards Safety standards EMC EN 611 Measurement category I (anticipated transient overvoltage 15 V), Pollution Degree 2 EN 61326 EN 6-3-2 EN 6-3-3 3273-5 3276 3276 DC to MHz (-3 db) * See Fig. 1 on page 1. 3.5 ns or less 3 Arms * Frequency derating see Fig. 2 on page 1. Non-continuous 5 Apeak.1 V/A ±1.% rdg. ±1 mv ( to 3 Arms / DC, 45 to 66 Hz) ±2.% rdg. (3 Arms to 5 Apeak / DC, 45 to 66 Hz) 2.5 marms or less (measured with 2 MHz bandwidth equipment) * See Fig. 3 on page 1. Within ±2% (from to 4 C [32 to 14 F] ) 5.3 VA (Input within the maximum input range.) ±12 V ±.5 V to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 5 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) 3 V, CAT-I (insulated conductor) Diameter max. 5 mm [.2"] Sensor: approx. 175(W) 18(H) 4(D) mm; 24 g [6.89"(W).71"(H) 1.57"(D), 8.5 oz.] Termination unit: approx. 27(W) 55(H) 18(D) mm [1.6"(W) 2.17"(H).71"(D)] Sensor cable: approx. 1.5 m [59.6"] (BNC connector) Power cable: approx. 1 m [39.38"] Hard case 1 EN 611 Measurement category I (anticipated transient overvoltage 15 V), Pollution Degree 2 EN 61326 EN 6-3-2 EN 6-3-3 Sensor head Composed of molded parts, ferrite and Hall elements. The thin-film of the Hall element especially improves detection sensitivity to realize wider bands and high sensitivity monitoring. 3273-5/3276 : approx. 175(W) 18(H) 4(D) mm, [6.89"(W).71"(H) 1.57"(D)] Maximum measurement conductor: dia. 5 mm [.2"] Sensor cable (approx. 1.5 m [59.6"]) Power cable (approx. 1 m [39.37"]) Power supply plug Connects to the FET probe power supply outlet of an oscilloscope or to the optional 3269 / 3272 power supply unit. (Provided that connector type, pin assignment, voltage, and capacity rating match, the 3273-5 to 3276 can be powered also from another source. For operation safety, be sure to refer to the specifications to ensure an exact match.) Power supply plug pin assignment (Plug as seen from the front) 1 : Not connected 1 2 2 : GND 4 3 3 : V- (-12V) 4 : V+ (+12V) * Connector type: LEMO inc./ FFA.S.34.CLAC42Z Sensor cable (approx. 2 m [78.74"]) 3274/3275 : approx. 176(W) 69(H) 27(D) mm, [6.93"(W) 2.72"(H) 1.6"(D)] BNC output connector Can be connected directly to the BNC input of an oscilloscope or level recorder or similar device. Output voltage rate:.1 V/A (3273-5 / 3276).1 V/A (3274 / 3275) (Use only equipment with an input impedance of 1 MΩ or more.) Maximum measurement conductor: dia. 2 mm [.79"]

CLAMP ON PROBE 3273-5 to 3276 5 3274 / 3275 Specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months) 3274 3275 Frequency bandwidth DC to 1 MHz (-3 db) * See Fig. 1 on page 2. DC to 2 MHz (-3 db) * See Fig. 1 on page 2. Rise time 35 ns or less 175 ns or less Continuous maximum input range Maximum peak current value 15 Arms * Frequency derating see Fig. 2 on page 2. Non-continuous 3 Apeak 5 A peak at pulse width of 3 ms 5 Arms * Frequency derating see Fig. 2 on page 2. Non-continuous 7 Apeak Output voltage rate.1 V/A.1 V/A Amplitude accuracy Noise ±1.% rdg. ±1 mv ( to 15 Arms / DC, 45 to 66 Hz) ±2.% rdg. (15 Arms to 3 Apeak / DC, 45 to 66 Hz) ±1.% rdg. ±5 mv ( to 5 Arms / DC, 45 to 66 Hz) ±2.% rdg. (5 Arms to 7 Apeak / DC, 45 to 66 Hz) Input impedance * See Fig. 3 on page 2. * See Fig. 3 on page 2. Sensitivity temperature Within ±2% (At 55 Hz/15 A input, to 4 C [32 to 14 F]) Within ±2% (At 5 Hz/5 A input, to 4 C [32 to 14 F]) Maximum rated power 5.5 VA (Input within the maximum input range.) 7.2 VA (Input within the maximum input range.) Power supply voltage ±12 V ±1 V ±12 V ±.5 V Operating temperature and humidity Storage temperature and humidity Effect of external magnetic fields to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 15 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 8 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) Max. rated voltage to earth 6 V CAT-II, 3 V CAT-III (insulated conductor) 6 V CAT-II, 3 V CAT-III (insulated conductor) Measurement conductor Diameter max. 2 mm [.79"] Diameter max. 2 mm [.79"] Sensor: approx. 176(W) 69(H) 27(D) mm; 5 g Sensor: approx. 176(W) 69(H) 27(D) mm; 52 g Dimensions and mass [6.93"(W) 2.72"(H) 1.6"(D), 17.6 oz.] [6.93"(W) 2.72"(H) 1.6"(D), 18.3 oz.] Termination unit: approx. 27(W) 55(H) 18(D) mm Termination unit: approx. 27(W) 55(H) 18(D) mm [1.6"(W) 2.17"(H).71"(D)] [1.6"(W) 2.17"(H).71"(D)] Cable length Sensor cable: approx. 2 m [78.74"] (BNC connector) Sensor cable: approx. 2 m [78.74"] (BNC connector) Power cable: approx. 1 m [39.37"] Power cable: approx. 1 m [39.37"] Supplied accessories Hard case 1 Hard case 1 Applicable standards Safety standards EMC 25 marms or less (measured with 2 MHz bandwidth equipment) EN 611 Overvoltage category II, III (anticipated transient overvoltage 4 V), Pollution Degree 2 EN 61326 EN 6-3-2 EN 6-3-3 25 marms or less (measured with 2 MHz bandwidth equipment) EN 611 Overvoltage category II, III (anticipated transient overvoltage 4 V), Pollution Degree 2 EN 61326 EN 6-3-2 EN 6-3-3 Current consumption of the 3273-5 to 3276 (sum of real values). [ 3273-5 ] [ 3274 ] [ 3275 ] [ 3276 ] current consumption (ma) 6 5 3274 3275 AC(f=5Hz) DC 4 3 2 1 2 3 current to be measured (A) current consumption (ma) 6 AC (f=5hz) 5 DC 4 3 2 5 15 current to be measured (A) Power Supply for Clamp-on Probes POWER SUPPLY 3269, 3272 3269 Combination example of the 3272 + Clamp-on probe Power supply for the Clamp on probe 3273-5 - 3276, CT67 series Supplies power when connected to a general-purpose instrument such as a recorder. current consumption (ma) 6 5 4 3 2 AC (f=5hz) DC 2 3 4 5 6 7 current to be measured (A) Basic specifications Compatible sensors Number of power supply connectors Output Power supply Dimensions and mass current consumption (ma) 6 AC (f=5hz) 5 DC 4 3 2 1 2 3 4 5 current to be measured (A) 3269 3272 Model CT67, CT671: up to 2 units Model CT67, CT671, 3273-5, Model 3273-5, 3274, 3275 or 3276: up to 1 unit 3274, 3275 or 3276: up to 4 units Note: May be used with up to 2 units of Model 3273 (not Note: Also up to 4 units for the discontinued -5 type), and up to 2 units of Models 3273-5, 3274, 3275 Model 3273 or 3276 on condition that the measurement current is sufficiently low. 4 2 ±12 V ±.5 V, ±2.5 A (sum total of all channels) V to 24 V AC (free) 5/6 Hz 17 VA max. 8 mm (3.15 in)w 119 mm (4.69 in)h 2 mm (7.87 in)d, 1.1 kg (38.8 oz) Accessories Instruction manual 1, Power cord 1 ±12 V ±.5 V, 6 ma (sum total of all channels) V or 12/ 22/ 24 V AC (specify when ordering), 5/6 Hz 2 VA max. 73 mm (2.87 in)w 11 mm (4.33 in)h 186 mm (7.32 in)d, 1.1 kg (38.8 oz) Power cord 1, Instruction manual 1, Spare fuse 1

6 Wide-Bandwidth, High-Precision and Large Current Measurements Basic specifications AC/DC CURRENT SENSOR CT6865, 979 HIOKI PL23 (1-pin terminal) A large current measuring applications in the fields of electric and hybrid electric vehicles (CT6865) Operating temperature range of -3 C to 85 C (CT6865) Super high precision, ±.6% amplitude accuracy, ±.2 phase accuracy Wide-bandwidth DC to 2 khz (CT6865), khz (979) excellent frequency Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with the 9555-1) Offset - Temperature Characteristics (979) CAT III V HIOKI ME15W (12-pin terminal) Effect of conductor position (the wire 1 mm diameter) (979) CT6865 (Accuracy guaranteed for 1 year, Post-adjustmentaccuracy guaranteed for 1 year) Rated input current A AC/DC Max. allowable input Frequency Amplitude and Phase accuracy 12 A AC/DC (Continuous 18 A peak, up to Hz, up to 4 C (14 F), other requires derating ) Amplitude: DC to 2 khz Phase: DC to 1 khz DC ±.5 % rdg. ±.1 % f.s. (Phase: Not defined) 16 Hz f 66 Hz ±.5 % rdg. ±.1 % f.s., Phase: ±.2 deg. Amplitude is defined to 2 khz, Phase is defined to 1 khz 979 (Accuracy guaranteed for 6 months, Postadjustment accuracy guaranteed for 6 months) 5 A AC/DC 7 Arms ( Apeak, requires derating at frequency) Amplitude: DC to khz Phase: DC to khz DC, 45 Hz f 66 Hz (±.5 % rdg. ±.1 % f.s. (Phase: ±.2 deg) Defined to khz Power consumption 7 VA max. 5 VA max. (at A/55 Hz, ±12 V power requirement) (at 5 A/55 Hz, ±12 V power requirement) Output voltage rate 2 V /rated current value (voltage output with the Sensor Unit 9555-1, use with a device having a 1 MΩ input resistance or higher) Max. rated voltage to earth AC/DC V (5/6 Hz, CAT III) Core diameter φ 36 mm (1.42 in) Operating temperature, humidity -3 C to +85 C (-22 F to 185 F) 8% rh or less (with no condensation) C to +5 C (32 F to 122 F) 8% rh or less (with no condensation) Power supply DC ±11 V to ±15 V (Power suppled via the 9555-1, which supports to 24 V AC) 16 mm (6.3 in)w 112 mm (4.41 in)h 5 mm Dimensions and mass (1.97 in)d, 98 g (34.6 oz), cord length 3 m (9.84 ft) Accessories Instruction manual 1, Mark bands 6 16 mm (6.3 in)w 112 mm (4.41 in)h 5 mm (1.97 in)d, 85 g (3. oz), cord length: 3 m (9.84 ft) Sensitivity - Temperature Characteristics (979) Model : AC/DC CURRENT SENSOR CT6865 Model No. (Order Code) CT6865 CT6865-5 (Note) ( A AC/DC) ( A AC/DC, 12 pin terminal) Model : AC/DC CURRENT SENSOR 979 979 (5A AC/DC) 979-5 (5 A AC/DC, 12 pin terminal) Delivering Wide-bandwidth and High-precision Current Measurement AC/DC CURRENT SENSOR CT6862, CT6863 HIOKI PL23 (1-pin terminal) CAT III V HIOKI ME15W (12-pin terminal) Super high precision, ±.6% amplitude accuracy, ±.2 phase accuracy Wide-bandwidth DC to 1 MHz (CT6862) excellent frequency Applications in the fields of electric and hybrid electric vehicles Wide operating temperature range fit for automobile applications Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with the 9555-1) Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year) CT6862 CT6863 Rated current 5 A AC/DC 2 A AC/DC Max. allowable input A (requires derating) 4 A (requires derating ) Frequency Amplitude and Phase accuracy Amplitude: DC to 1 MHz Phase: DC to 3 khz Amplitude: DC to 5 khz Phase: DC to 3 khz DC ±.5 % rdg. ±.1 % f.s. (Phase: Not DC ±.5 % rdg. ±.1 % f.s. (Phase: Not defined) defined) 16 Hz f 4 Hz ±.5 % rdg. ±.1 % f.s. 16 Hz f 4 Hz ±.5 % rdg. ±.1 % f.s. (Phase: ±.2 ) (Phase: ±.2 ) Defined to 1 MHz Defined to 5 khz Power consumption 5 VA max. (at 5 A/55 Hz, ±12 V power requirement) 6 VA max. (at 2 A/55 Hz, ±12 V power requirement) Output voltage 2 V/rated current range (voltage output with the Sensor Unit 9555-1, use with a device having a 1 MΩ input resistance or higher) Max. rated voltage to earth AC/DC V (5/6 Hz, CAT III ) Core diameter φ 24 mm (.94 in) Operating temperature, humidity -3 C to +85 C (-22 F to 185 F), 8% rh or less (with no condensation) Power supply DC ±11 V to ±15 V (Power suppled via the 9555-1, which supports to 24 V AC) Dimensions and 7 mm (2.76 in)w mm (3.94 in)h 53 mm (2.9 7 mm (2.76 in)w mm (3.94 in)h 53 mm (2.9 mass in)d, cord length: 3 m (9.84 ft), 34 g (12. oz) in)d, cord length: 3 m (9.84 ft), 35 g (12.3 oz) Accessories Instruction manual 1, Mark bands 6 Model : AC/DC CURRENT SENSOR CT6862 Model No. (Order Code) CT6862 CT6862-5 (Note) (5 A AC/DC) (5 A AC/DC, 12 pin terminal) Model : AC/DC CURRENT SENSOR CT6863 Model No. (Order Code) CT6863 CT6863-5 (Note) (2 A AC/DC) (2 A AC/DC, 12 pin terminal)

7 Shared options for CT6865, 979, CT6862, and CT6863 Options A SENSOR UNIT 9555-1 Power supply for current sensors when used alone CONNECTION CORD L9217 Cord has insulated BNC connectors at both ends, for signal output, 1.6 m (5.25 ft) length CONNECTION CORD 9165 Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length, not CE marked Options B Connects up to 2 cables in series, Cannot be used in combination with the CT6862/ 63 or 9277 to 9279 CONVERSION CABLE CONVERSION CABLE CT99 CT991 Convert HIOKI PL23 (1-pin) to Convert HIOKI ME15W (12-pin) HIOKI ME15W (12-pin) terminal to HIOKI PL23 (1-pin) terminal EXTENSION CABLE 976 Extension for 5 m (16.41 ft) length, HIOKI PL23 (1-pin) - HIOKI ME15W (12-pin) terminal Options C Connects up to 2 cables in series, Cannot be used in combination with the CT6862/ 63 or 9277 to 9279 EXTENSION CABLE CT992 Extension for 5m(16.41 ft) length, HIOKI ME15W (12-pin) - HIOKI PL23 (1-pin) terminal Options D For connecting to the F/V Unit 894 or Current Unit 8971 CONVERSION CABLE 975.2 m (.66 ft) length, to connect the CT6841/43/44/45/46, CT6863/65, 979, 9272-1 to the F/V Unit 894 Cannot be used in combination with the CT6862 CONVERSION CABLE 9318 To connect the CT6841/43/44/45/46, CT6865/63, 9277/78/79, 927/71/72 to the 8971/4/51, 38 cm (14.96 in) length Ideal for Measuring Current with Low Frequencies such as Inverter Control Devices CLAMP ON SENSOR 9272-1 Model : CLAMP ON SENSOR 9272 9272-1 (2/2 A AC) Note: This product cannot be used alone. The optional 9555-1 is required in order to supply power and connect the clamp to a Memory HiCorder or other instrument. The clamp can be directly connected the Power Meter 3193-1, 3193, 3194, and 339. CAT III 6 V Superior low frequency and phase suitable for testing the current and power of inverter control devices Wide 1 Hz to khz frequency bandwidth perfect for harmonic analysis, FFT analysis and waveform monitoring Basic specifications (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months) Rated current 2 A AC, or 2 A AC (selectable) Max. allowable input 2 A range: 5 A rms Max. 2 A range: 3 A rms Max. Accuracy Amplitude: ±.3 % rdg. ±.1 % f.s. Phase: ±.2 (45 to 66 Hz) Frequency 1 Hz (±2 % rdg. ±.1 % f.s.) to khz (±3 % rdg. ±.1 % f.s.) Output rate 2 V/2 A rated current range, or 2 V/2 A rated current range (voltage output With the 9555-1 with the Sensor Unit 9555-1, use with a device having a 1 MΩ input resistance or higher) Max. rated voltage to earth 6 V rms (CAT III) Core diameter φ 46 mm (1.81 in) Power supply DC ±11 V to ±15 V (Power suppled via the 9555-1, which supports to 24 V AC) Power consumption 5 VA Max. (when measuring 2 A) Dimensions and mass 78 mm (3.7 in)w 188 mm (7.4 in)h 35 mm (1.38 in)d, 43 g (15.2 oz), cord length: 3 m (9.84 ft) Accessories Carrying case 9355 1, Instruction manual 1, Mark bands 6 Model 9272-1 Compatibility (use with the connection cord) Compatible models Status Note 3193-1, 3193, 3194 (use with the 962) 3 Directly connectable, Add.1% rdg. to accuracy MR8827, MR8847s (use with the 8971) 3 To connect via the Conversion Cable 9318 Model 894 for Memory HiCorders 3 Need the Conversion Cable 975, and use with the Conversion Cable 9318 to connect Model 9272-1 to the F/V Unit 894. (Not necessary when using Model 9272 due to different output wiring specifications.) Options A SENSOR UNIT 9555-1 Power supply for current sensors when used alone CONNECTION CORD L9217 Cord has insulated BNC connectors at both ends, for signal output, 1.6 m (5.25 ft) length CONNECTION CORD 9165 Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length, not CE marked CONVERSION CABLE 9318 To connect the CT6841/43, CT6865/63, 9277/78/79, 927/71/72 to the 8971/4/51, 38 cm (14.96 in) length *The 9355 is bundled CARRYING CASE 9355 For the 9272-1, 927s, or other models Options B *The Clamp Sensor 9272-1 has different output wiring than the previous 9272. Both the 9318 and 975 are required in order to connect to the F/V Unit 894. CONVERSION CABLE 975.2 m (.66 ft) length, to connect the CT6841/6843, CT6863/6865, 979, 9272-1 to the F/V Unit 894 Cannot be used in combination with the CT6862 EXTENSION CABLE 976 Extension for 5 m (16.41 ft) length, HIOKI PL23 (1-pin) - HIOKI ME15W (12-pin) terminal SENSOR UNIT 9555-1 Basic specifications Compatible sensor One of the CT6862 to CT6865 series, CT6841 to CT6846 series, 979, 9279 to 9277 series, 9272-1, 927 to 9272 series Output Terminal BNC Terminal Power supply AC Adapter 9418-15, to 24 V, 5/6 Hz, 2 VA Dimensions and mass 42 mm (1.65 in)w 82 mm (3.27 in)h 132 mm (5.2 in)d, 6 g (21.2 oz) Accessories Instruction manual 1, AC Adapter 9418-15 1 Power supply for the Current Sensor series when the sensors are used alone Model No. (Order Code) 9555-1 Compatible models...ct6865 (-5), 979 (-5) Compatible models CT6865 CT6865-5 979 979-5 Model s (Requires CT99) 3 s (Requires CT99) 3 PW61 CT ratio: 2 s (Requires CT991) Model 339 3 CT ratio: 2 3 s (Requires CT991) CT ratio: 2 Input unit model 962 for 3193-1/ 3193/ 3194 Model 8971 Model 894 3 CT ratio: 2 s (Requires 9318) CT ratio: 2 975) CT ratio: 2 s (Requires CT991) CT ratio: 2 CT991) CT ratio: 2 s (Requires 9318, 975, and CT991) CT ratio: 2 3 s (Requires CT991) s (Requires 9318) s (Requires 9318 and 975) CT991) s (Requires 9318, 975, and CT991) Compatible models...ct6862 (-5), CT6863 (-5) Compatible models CT6862 CT6862-5 CT6863 CT6863-5 Model PW61 s (Requires CT99) 3 s (Requires CT99) 3 Model 339 3 s(requires CT991) 3 s (Requires CT991) Input unit model 962 for 3193-1/ 3193/ 3194 3 s (Requires CT991) 3 s (Requires CT991) Model 8971 s (Requires 9318) s (Requires 9318) CT991) CT991) Model 894 N/A N/A s (Requires 9318 and 975) s (Requires 9318, 975, and CT991)

Rated current & Frequency AC/DC AC For wide-band current observatiom For high-precision current measurement up to 5A up to 15A 1mA class to 3A up to A up to 5A up to 2A up to 5A up to 2A up to 2A 3275 : DC to 2 MHz 3274 : DC to 1 MHz 3273-5 : DC to 5 MHz 3276 : DC to MHz CT6865 : DC to 2 khz 979 : DC to khz CT6863 : DC to 5 khz CT6862 : DC to 1 MHz 9272-1 (2A) : 1Hz to khz 9272-1 (2A) : 1Hz to khz Frequency (Hz) DC 1 1 1k 1k k 1M 1M M Wide-Band Current Probe Allows Direct Input to Oscilloscope CLAMP ON PROBE 3273-5, 3274, 3275, 3276 Model : CLAMP ON PROBE 3273 3273-5 (DC to 5 MHz, 3 Arms) 3275 Insulated conductor Model : CLAMP ON PROBE 3274 3274 (DC to 1 MHz, 15 Arms) 3274 3273-5 3276 Note: Use the Power Supply 3269/3272 for general measurements or when power is not available from the Memory Hicorder. When performing continuous measurements, be aware of offset voltage drift. 3269 3272 Model : CLAMP ON PROBE 3275 3275 (DC to 2 MHz, 5 Arms) Model : CLAMP ON PROBE 3276 3276 (DC to MHz, 3 Arms) Options POWER SUPPLY 3272 For single sensor, 12/ 22/ 24 V AC, specify when ordering POWER SUPPLY 3269 For four sensors, V to 24 V AC CONVERSION CABLE 9319 To connect the 3273-5 and the 894, Note: cannot be used with the 3274, 3275, 3276 to connect the 894 via this cable 9319 WARNING 1. To avoid short circuits and electric shock accidents when using a clamp-on sensor, use only with power lines carrying voltages within the rating limit of the sensor. 2. To avoid short circuits and electric shock accidents when the clamp-on sensor is open, do not use on bare conductors. Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. Test Equipment Depot - 8.517.8431-99 Washington Street Melrose, MA 2176 TestEquipmentDepot.com All information correct as of July 28, 216. All specifications are subject to change without notice. Current_sensor_E6-67E Printed in Japan