Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level

Similar documents
Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Agilent 4072A Advanced Parametric Test System with Agilent SPECS

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement

Keysight Technologies Power of Impedance Analyzer

Variable-temperature, wafer-level capacitance measurements

Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement

Agilent Technologies Impedance Measurement Handbook December 2003

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Wafer Probing System Parametric Evaluation Files

Linear Regulators: Theory of Operation and Compensation

Switching Between C-V and I-V Measurements Using the 4200A-CVIV Multi-Switch and 4200A-SCS Parameter Analyzer APPLICATION NOTE

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Grundlagen der Impedanzmessung

Agilent Accessories Selection Guide For Impedance Measurements. December 2008

Fast IC Power Transistor with Thermal Protection

S540 Power Semiconductor Test System Datasheet

Agilent 4285A Precision LCR Meter

Measuring CNT FETs and CNT SETs Using the Agilent B1500A

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

Keysight Technologies


Agilent How To Accurately Evaluate Low ESR, High Q RF Chip Devices. Application Note

The Aleph 2 is a monoblock 100 watt audio power amplifier which operates in single-ended class A mode.

Impedance Measurement Handbook

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Figure 2 shows the actual schematic for the power supply and one channel.

Three Terminal Devices

Accessories Selection Guide For Impedance Measurements. April 2005

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

S540 Power Semiconductor Test System Datasheet


Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

High Speed Parametric Test Using Agilent 4070 Series

APPLICATION NOTE. Wide Range of Resistance Measurement Solutions from μω to PΩ

The Aleph 5 is a stereo 60 watt audio power amplifier which operates in single-ended class A mode.

Test Structure Design for Parallel Testing

4082A Parametric Test System Keysight 4080 Series

Agilent AN Applying Error Correction to Network Analyzer Measurements

LF444 Quad Low Power JFET Input Operational Amplifier

Agilent AN 1310 Mobile Communications Device Testing

Frequency-Domain Characterization of Power Distribution Networks

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Welcome! Device Characterization with the Keithley Model 4200-SCS Characterization System.

Keysight Technologies Accessories Catalog for Impedance Measurements. Catalog

Agilent 4083A DC/RF Parametric Test System A fully automatic on-wafer RF S-parameter measurement environment

LF442 Dual Low Power JFET Input Operational Amplifier

Achieving 3000 V test at the wafer level

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

AN301. High-Speed DMOS FET Analog Switches and Switch Arrays. Introduction. Description. Principle of Operation. Applications

TL082 Wide Bandwidth Dual JFET Input Operational Amplifier

UNIT 3: FIELD EFFECT TRANSISTORS

Agilent LCR Meters, Impedance Analyzers and Test Fixtures

Permittivity Measurements of PC Board and Substrate Materials using the HP 4291B and HP 16453A

Keysight Technologies E4980A Precision LCR Meter

Solving Connection Challenges in On-Wafer Power Semiconductor Device Test. Application Note Series. Introduction

Agilent U9397A/C FET Solid State Switches (SPDT)

LDO Regulator Stability Using Ceramic Output Capacitors

LM6162/LM6262/LM6362 High Speed Operational Amplifier

Transient Current Measurement for Advance Materials & Devices

EIS Measurement of a Very Low Impedance Lithium Ion Battery

Using the 4200A-CVIV Multi-Switch to Make High Voltage and High Current C-V Measurements APPLICATION NOTE

Frequency Response Properties of the Silicon Vertex Detector for BaBar

Keysight Technologies Accessories Catalog for Impedance Measurements. Catalog

Agilent 4284A/4285A Precision LCR Meter Family

Internal Model of X2Y Chip Technology

Keysight Technologies Precise Evaluation of Input, Output, and Reverse Transfer Capacitances of Power Devices. White Paper

6 Tips for Successful Logic Analyzer Probing

MOSFET & IC Basics - GATE Problems (Part - I)

Advanced Test Equipment Rentals ATEC (2832)

LF444 Quad Low Power JFET Input Operational Amplifier

Verification Structures for Transmission Line Pulse Measurements

Lithium-ion batteries are emerging as the de facto. battery.

Agilent 4287A RF LCR Meter 1 MHz - 3 GHz. Technical Overview

INTRODUCTION: Basic operating principle of a MOSFET:

Agilent EEsof EDA.

LF353 Wide Bandwidth Dual JFET Input Operational Amplifier

Network, Spectrum, and Impedance Evaluation of Electronic Circuits and Components

Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

A Self-Biased Anti-parallel Planar Varactor Diode

Low Noise, Matched Dual PNP Transistor MAT03

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Direct calculation of metal oxide semiconductor field effect transistor high frequency noise parameters

LM6172 Dual High Speed, Low Power, Low Distortion, Voltage Feedback Amplifiers

Wide Range DC Current Biased Inductance Measurement. Application Note with HP 4284A Precision LCR Meter / HP 42841A Bias Current Source

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Keysight E5061B-3L3/3L4/3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function

Application Guidelines for Non-Isolated Converters AN Input Filtering for Austin Lynx Series POL Modules

Power MOSFET Zheng Yang (ERF 3017,

Ensuring that Power Supply Performance Meets Your Requirements. Application Note Series

profile New Generation Precision Impedance Analyzer for functionality and efficiency in engineering 40 Hz to 110 MHz 4294A

Keysight Technologies Solid State Switches. Application Note

Keysight Technologies Making Matching Measurements for Use in IC Design

The Design and Characterization of an 8-bit ADC for 250 o C Operation

Using High-Directivity Couplers in Isolatorless Cellular Phone PA Control

Special-Purpose Operational Amplifier Circuits

Transcription:

Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level Application Note 4070-2 Agilent 4070 Series Semiconductor Parametric Tester

Introduction The continuing trend of decreasing device geometries of the next generation of ULSI devices is making precise characterization evaluation of semiconductor devices more and more critical. Measurement of capacitance is used to determine oxide thickness, one of the key parameters of semiconductor devices. This oxide thickness is becoming thinner and thinner from generation to generation. Therefore, accurate capacitance measurement is very important in semiconductor process integration and process monitoring. The Agilent 4070 series of semiconductor parametric testers perform accurate capacitance measurements, reliably and quickly. In order for 4070 series testers to perform such precise measurements, appropriate fixturing and measurement techniques are required. (A) (B) CMU Hp 4 m cable Hc Mother B d Input B d [F1] 4m cable Input Board Mother Board Pin B d Probe Card Switching matrix Pin Board Probe card Device Figure 1. (A) Simplified diagram of Agilent 4070 series tester (B) Equivalent circuit of measurement path for capacitance measurement DUT [F(DUT + Probe card)] Pin B d Probe Card [Ftotal] = [F1] [F(DUT + Probe card)] [F2] [F(DUT + Probe card)] = [F1] 1 [Ftotal] [F2] 1 Mother B d Input B d [F1] SMU Lp Lc 4 m cable This application note describes the procedures required to precisely evaluate the capacitance of a Device Under Test (DUT) when using a 4070 series tester with an automatic wafer prober. Chuck Probe pin Wafer Step 1 Measure Coffset with prober s chuck down (A) Cp G Factors Affecting the Measurement of Capacitance and Problem-Solving Techniques Chuck Step 2 Measure Cmeas by probing DUT (B) R Cs Stray Capacitance and Residual Inductance Cable and electrical leads in the measurement system behave like distributed electrical lines when a highfrequency AC signal passes through them. Capacitance measurement in 4070 series testers is done by applying a relatively high frequency measurement signal, selectable from 20 Hz to 1 MHz, to the DUT and then measuring the resulting current using an autobalancing bridge circuit. Cdut =Cmeas Coffset Step 3 Calculate DUT s capacitance by subtracting Coffsett Figure 2. Procedure to cancel offset capacitance (C) n+poly- Si Oxide A1 Figure 3. (A) Equivalent circuit of normal device (B) Equivalent circuit of device that has large series resistance (C) Example of device structure that has large series resistance p p+ 2

When measuring capacitance using a high frequency signal such as 1 MHz, stray capacitance and residual inductance inherent to cables, electrical leads, and other portions of the measurement circuit can cause AC signal loss. This leads to degradation of the capacitance measurement accuracy. Figure 1 shows an equivalent circuit of the measurement path. The Capacitance Measurement Unit (CMU) in 4070 series testers regards the entire measurement path as the device to measure. Compensation for the cables and switching matrix is automatically performed by the Test Instruction Set (TIS) command so that the actual capacitance of the DUT is obtained. For example, the compensation for 4 m cables is performed by a built-in function of the CMU (Agilent 4284A). For a switching matrix, the actual capacitance of the DUT is calculated by multiplying the inverse matrix of the F matrix by the entire measurement value. The circuit constants used in the F matrix are measured when the system is installed and recorded for each 4070 series tester. Therefore, precise capacitance measurement results are obtained by using TIS commands. Offset Capacitance The offset capacitance caused by a probe card or probe needles cannot automatically be compensated for by the TIS commands. Offset capacitance depends on the probe card used. If adjacent pins and the recommended probe card are used, the offset capacitance value would be smaller than 500 ff. To obtain the actual capacitance of the DUT, measure the offset capacitance and then measure the capacitance of the DUT. Subtract the offset capacitance from the measured capacitance. (See Figure 2.) Series Resistance of the DUT In most cases, semiconductor capacitors can be viewed as a parallel circuit of capacitance and conductance. Agilent 4070 series testers assume the DUT can be modeled as a parallel connection of capacitance and conductance. However, in other cases, the equivalent circuit of the device can be drawn as a series connection of resistance and capacitance. For instance, if poly-si is used between the oxide and Al lead and the resistance of the poly-si is relatively large compared to the impedance of the capacitance, the DUT is regarded as a series connection of capacitance and resistance. In such cases, measurement results need to be adjusted to eliminate the error caused by the incorrect assumption. The Conv_mode command is provided to allow you to calculate the correct capacitance value if the equivalent circuit of the DUT can be modeled as a series connection of resistance and capacitance. Measurement signal Leakage to ground Figure 4. Unexpected leakage of measurement signal Signal Loss Through the Large Chuck of the Prober The capacitance between the chuck on the probe station and ground is becoming large. There are two reasons for this. 1) The size of the chuck on the probe station is increasing as wafer size increases. Capacitance is proportional to chuck size. 2) The demand for a hot chuck is increasing for process integration or process monitoring. Having the heater of the hot chuck close to the top of the chuck reduces the distance between the chuck top and ground, which results in the increase of capacitance to ground. In many situations, the large capacitance between the chuck and ground affects the accurate capacitance measurement of the DUT. When the chuck on a probe station is used as a measurement terminal for the capacitance measurement, the measurement current flows to ground through the chuck. Unexpected leakage of the measurement signal affects measurement accuracy. (See Figure 4.) 3

The same type of signal loss occurs when the isolation is insufficient between the expected measurement signal path and the chuck on the probe station. (A) p (B) n p Figure 5 shows two other typical device structures. If the electrode for the wafer substrate is placed on the top side of a wafer, an error can occur if the device structure is as shown in Figure 5(A) where the wafer substrate and probe chuck are not electrically isolated. Figure 5. Device structure The device structure shown in Figure 5(B) has better isolation between the measurement signal path and the prober chuck because the PN junction formed by the N-well in the P-substrate acts as a barrier for the leakage current. The isolation level of the PN junction determines whether or not there is a signal loss to ground. Figure 6 shows the frequency dependency of capacitance measured on the device shown in Figure 5(A). The results show that measurement error increases as the measurement frequency is increased beyond 200 khz. The amount of error increases up to 4% at a 1 MHz measurement frequency. When a high frequency measurement signal is used, signal loss is proportional to the residual inductance and stray capacitance along the measurement signal path. Therefore, total measurement error is proportional to the square of the measurement frequency. In other words, if the measurement frequency is reduced by a factor of 10, then the measurement error is reduced by a factor of 100. A 4% error observed at a 1 MHz measurement frequency is reduced to a negligible level if the measurement frequency is reduced to 100 khz. 4 5.30E-11 5.25E-11 Cap (F) 5.20E-11 5.15E-11 5.10E-11 5.05E-11 1.E+03 2.E+03 5.E+03 1.E+04 2.E+04 5.E+04 1.E+05 2.E+05 5.E+05 1.E+06 The accuracy of a capacitance measurement is proportional to the measurement frequency. The CMU measures the current induced by the capacitance of the DUT. For an AC signal this current is proportional to the measurement frequency (I = 2 pfcv). Figure 7 shows the relationship between the standard deviation of the capacitance measured on the actual device and measurement frequency. The results show that measurement accuracy improves as the measurement frequency is increased. It decreases when measurement frequency is over 200 khz. This degradation at frequencies over 200 khz is due to the effects of inductance along the signal path. Freq (Hz) Figure 6. Frequency dependency of capacitance taken on the device structure shown in Figure 5(A) Therefore, a measurement frequency between 10 khz and 100 khz is recommended when measuring capacitance. External Signal The measurement results are affected if the measurement environment includes a large amount of electrical noise. If the capacitance between the prober chuck and ground is large, then the chuck will likely receive high frequency noise. This is because the isolation between the prober chuck and ground is not as good in the high frequency range.

Standard Deviation (F) 1.00E-11 1.00E-12 1.00E-13 1.00E-14 1.00E-15 1.00E-16 1.E+03 The major sources of noise in the automatic prober are the power supply circuit and the hot chuck. If sufficient shielding is provided in the prober station, then the measurement is less affected by the ambient noise. Using a large AC signal to increase the signal-to-noise ratio will reduce the error caused by external noise. 2.E+03 5.E+03 1.E+04 2.E+04 5.E+04 Frequency (Hz) Figure 7. Frequency dependency of standard deviation of measured capacitance (Integration time: LONG) Standard Deviation (F) 1.00E-12 1.00E-13 1.00E-14 1.00E-15 1.00E-16 5.0E-03 1.0E-02 2.0E-02 Signal level (V) 1.E+05 2.E+05 5.10E-11 5.09E-11 5.08E-11 5.07E-11 5.06E-11 5.05E-11 5.04E-11 5.03E-11 5.02E-11 5.01E-11 Figure 8. Signal level dependency of standard deviation of capacitance measurement 3.0E-02 5.0E-02 1.0E-01 Figure 8 shows the signal level dependencyof standard deviation of capacitance measurements. Integration time is also varied from short to long. Repeatability is improved as signal level is increased. The standard deviation can be reduced to less than 1 ff by using a 100 mv signal level and a long integration time. 5.E+05 Capacitance (F) 1.E+06 Short Medium Long Cap (S) Cap (M) Cap (L) However, depending on the characteristics of the DUT, increasing the signal level can have a negative impact on the capacitance measurement. If C-V measurement is desired, characteristics in depletion mode can have some error because the capacitance value changes drastically with applied voltage. Signal level should be determined by considering the voltage dependency of the DUT in the swept voltage range and the required repeatability. When evaluating oxide thickness, using a large signal level will help reduce the measurement error. Oxide thickness is calculated from the capacitance value when the DUT is in an accumulation mode that doesn t show voltage dependency. When evaluating oxide thickness by measuring capacitance in accumulation mode, it is important to put the device well into accumulation mode. The applied bias voltage should be determined by finding the C-V characteristics where the capacitance fluctuation caused by a change in voltage is small. Quasi-unbalanced State Caused by Improper Connection When the capacitance between the chuck and ground is large, the connections between the measurement ports and the device terminals are important for making a precise capacitance measurement. Figure 9 shows example measurement results taken with two different connections of the measurement ports and the device terminals. One result was measured by connecting the port to the gate terminal of the device and connecting the port to the substrate terminal of the device. The other result was measured by connecting the port to the gate terminal and connecting the port to the substrate terminal. When connecting the to the gate terminal 5

a deviation of up to 7% can be seen. The opposite connection shows a stable result. This kind of error does not always occur. It depends on the DUT and the measurement environment. 5.50E-11 5.45E-11 5.40E-11 5.35E-11 5.30E-11 The CMU in the Agilent 4070 series tester uses an auto-balancing bridge method to measure the impedance of the DUT as shown in Figure 10. Cap (F) 5.25E-11 5.20E-11 5.15E-11 5.10E-11 5.05E-11 -> Gate -> Gate The detector D detects the potential at point A and controls the magnitude and phase of the Osc2 output so the detected potential is zero. If the measurement signal is not stable, then it becomes difficult for the auto-balancing bridge to force stabilization of the potential at point A to zero. When the port is connected to the substrate terminal of a device and the substrate has insufficient isolation from the chuck on the prober, the autobalancing bridge is likely to become unbalanced due to the large capacitance and external noise. Figure 11 shows C-V measurement results with both connections. Clearly, connecting the port to the gate and the port to the substrate provides better measurement results. The recommended connection is shown in Figure 12. In this case, the polarity of the bias voltage must be taken into account when writing a measurement algorithm. 1.E+06 5.E+05 2.E+05 1.E+05 5.E+04 2.E+04 1.E+04 5.E+03 2.E+03 1.E+03 Freq (Hz) Figure 9. Measurement results with two different connections E(dut) Osc DUT Zx V D E(dut) Zx = Rr E(rr) Figure 10. Auto-balancing bridge in CMU (A) (B) E(rr) A Rr Osc 2 CV Characteristics (-> Gate) CV Characteristics ( -> Bulk) 6.00E-11 6.00E-11 Signal Loss Through Other Devices When the capacitance between probe pins is high and the capacitance of the adjacent device is not negligible, then an unexpected current path is formed as shown in Figure 13. In this case, additional current flows into the port through the stray capacitance between probe pins and the adjacent device. Cap (F) 4.00E-11 3.00E-11 2.00E-11 1.00E-11 0.00E+00-5.5-4.3-3.1-1.9-0.7 0.5 1.7 Vg ( V ) 2.9 4.1 5.3 10k Short 10k Medium 10k Long 100k Short 100k Medium 100k Long Cap (F) 4.00E-11 3.00E-11 2.00E-11 1.00E-11 0.00E+00-5.5-4.3-3.1-1.9-0.7 0.5 1.7 Vg (V) 2.9 4.1 5.3 10k Short 10k Medium 10k Long 100k Short 100k Medium 100k Long Figure 11. Measurement results with two different connections (A) Connecting port to the gate terminal and port to the substrate (B) Connecting the port to the gate and the port to the substrate 6

A CMU84 The measured capacitance value is larger than the actual capacitance value since additional current is measured by the current meter in the port. The total amount of error is determined by the stray capacitance between the measurement pins and the capacitance value of the adjacent device. (See Figure 13.) Figure 12. Recommended connection Coff_Adj1 Adjacent DUT (Coff_Adj_DUT) Coff_Adj2 With Agilent 4070 series testers, the error caused by this mechanism will be limited to less than a couple of hundred ff if the recommended probe card is used. The problem is likely to be seen when correlating the results between the Agilent 4070 series testers and other parametric testers. Due to large stray capacitance between the probing needles, other parametric testers can exhibit an error as large as the amount of stray capacitance between the measurement pins. DUT Error = 1/(1/Coff_Adj1 + 1/Coff_Adj2 + 1/Coff_Adj_DUT) There are three solutions for solving this problem. Figure 13. Unexpected current flow through other devices SWM CMU 1) Use a probe card interface and a probe card that have a small stray capacitance between the measurement pins. Reducing capacitance between pins is achieved by having a shield around the measurement pin. However, the cost of changing the probe card interface and probe card may be too great. Coff_Adj1 GCMU Adjacent device 4m cable Coff_Adj2 2) Change the test structure so adjacent devices do not have large capacitances. Stray capacitance between measurement pins is inversely proportion to the distance between the pins. Swapping the pad locations for the pins by modifying the design of the test structure will reduce this error significantly. DUT Figure 14. Reducing error by connecting the GCMU to adjacent terminals 3) Use the GCMU to sink extraneous current flow through the stray capacitance between pins. 7

Cap ( F) 6.00E-11 4.00E-11 3.00E-11 2.00E-11 1.00E-11 0.00E+00 The third suggestion is the easiest to implement. The GCMU is the shield of the CMU as shown in Figure 14. Extraneous current, going through stray capacitance between pins, will flow into the GCMU. This is because the impedance of the GCMU is lower than the impedance of the adjacent device. Additional current will not be measured by the current meter in the port. For example, this method will not work when the impedance between the measuring pad and the adjacent pad is low. However, it should be the first method tried when the capacitance measured by the other tester is larger than that measured by the 4070 series tester. Conclusion Agilent 4070 series testers can perform accurate and repeatable capacitance measurements. (See Figure 15.) The following conditions are necessary for the system to reach its full potential: CV Characteristics (p-substrate) -5.5-5.2-4.9-4.6-4.3-4 -3.7-3.4-3.1-2.8-2.5-2.2-1.9-1.6-1.3-1 -0.7-0.4-0.1 0.2 0.5 0.8 1.1 1.4 1.7 Figure 15. Example measurement results Vg (V) 2 2.3 2.6 2.9 3.2 3.5 3.8 4.1 4.4 4.7 5 5.3 2) When the series resistance in the DUT is large, compensation by using the Conv_mode command is required. 3) A measurement frequency between 10 khz and 100 khz should be used in order to avoid signal loss caused by the large capacitance of the chuck. 4) A higher signal level is recommended to reduce the effect of external noise. 5) To reduce noise and to reduce unbalance of the CMU, it is important to connect the port to the bulk or substrate and to connect the port to the gate. 6) An appropriate probe card that has small stray capacitance between pins is required. For more information about Agilent Technologies semiconductor test products, applications, and services, visit our website: www.agilent.com/go/semiconductor or you can call one of the centers listed and ask to speak with a semiconductor test sales representative. For more information about other Agilent test and measurement products, go to www.agilent.com United States: 1 800 452 4844 Canada: 1 877 894 4414 Europe: (31 20) 547 2000 Japan: (81) 426 56 7832 Fax: (81) 426 56 7840 Latin America: (305) 269 7500 Fax: (305) 269 7599 Australia/New Zealand: 1 800 629 485 (Australia) Fax: (61 3) 9272 0749 0 800 738 378 (New Zealand) Fax: (64 4) 495 8950 Asia Pacific: (852) 2599 7889 Fax: (852) 2506 9233 Taiwan: (886 2) 717 9524 Fax: (886) 2 718 9860 Korea: (822) 769 0800 Fax: (822) 786 1083 Singapore: (65) 1 800 292 8100 Fax: (65) 275 0387 Product specifications and descriptions in this document subject to change without notice. Copyright 2000 Agilent Technologies Printed in U.S.A. 11/00 5968-2499E 1) The offset capacitance must be subtracted in the user s measurement program.