This addendum forms a part of the Contract Documents dated: August 10, 2012.

Similar documents
PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

SECTION MANHOLES

HUSSEY GAY BELL SAVANNAH, GEORGIA

Miscellaneous. Demolition

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD.

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION MANHOLES

Appendix C Construction Details

PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT ADDENDUM NO. 1

CITY OF MUSKEGO DRAFTING STANDARDS

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

STANDARD BID ITEM NUMBERS

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

MSD STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY

February 18, Re: Zephyr Lakes Amenity Center Zephyrhills, Florida

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

Standard Specifications

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

June 10, 2014 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS

INVITATION FOR BID (IFB) IFB NO. GSWA

ROWAN UNIVERSITY 201 MULLICA HILL ROAD GLASSBORO, NEW JERSEY 08028

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed 6/1/18 STANDARD DRAWINGS

Grease Interceptor Design Checklist

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

BID TABULATION SUMMARY Project: CONTRACT 3 SANITARY SEWER REPLACEMENTS Bid Date: Wednesday, January 10, :00 PM

STRUCTURES FOR SANITARY AND STORM SEWERS

I. MINUTES OF THE PRE-BID CONFERENCE

MAY J. Collins Engineering Associates, LLC San Jose Blvd. Jacksonville, Florida 32223

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

MAJOR GRADING PLAN CHECKLIST

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP

CITY OF SAN MARCOS ENGINEERING DIVISION

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

ROUTES: 65 SECTIONS: miles in length. THE FOLLOWING ITEMS AND APPROXIMATE QUANTITIES ARE INVOLVED:

City of Massillon Site Plan Checklist


2. What are the estimated volumes for the Residuum Harvesting See response to Question 1

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

OFFICE OF MANAGEMENT AND FINANCE

City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS

TAXIWAY B NORTH ROAD RUNWAY TAXIWAY C NORTH ROAD VICINITY MAP. Plans Prepared By:

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

EXTERIOR BUILDING, ROOFING, AND SITE IMPROVEMENTS

SECTION PRECAST CONCRETE STRUCTURES

FINAL ENGINEERING FOR 11 W. HOME AVE. VILLA PARK, IL LOCATION MAPS VICINITY SITE LOCATION SUMMARY OF QUANTITIES 67 FT. 32 FT. 92 SQ.-FT.

SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM Miraloma ES & Sunnyside ES Green Schoolyard ADDENDUM NO. 1

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

CITY OF DANA POINT DEVELOPMENT REVIEW

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

Application for Site Plan Review

"A" "A" SECTION "A-A" X-SECTION VERTICAL CURB (TYPE B) Village STREET & PAVEMENT STR-05. Engineering Department

Washington County Road Engineering Plan Submittal/Review Checklist

Oil-Water Separator Design Checklist

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST

Guidelines and Checklist For SAWS Sanitary Sewer. Developmental Engineering Division

CONCRETE MANHOLES.

Peters Township Sanitary Authority 3244 Washington Road McMurray, PA 15317

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

SECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings

Sewer Line Extension Permit Design Checklist

November 16, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA. Y CH / Addendum #6 SHERRY DRIVE BRIDGE REPLACEMENT

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee)

PART MATERIALS. Section Fencing Materials. Description

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF VISTA STANDARD DRAWINGS

APPENDIX FENCE GENERAL NOTES

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

Marshall Truck Station Laboratory Addition Project No. TZ MnDOT

RECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO.

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

LONCY LEAKE BASEBALL FIELD RENOVATION MESQUITE, TX PROJECT NO ISSUED FOR PROPOSALS

I. GENERAL: The Bidding and Contract Documents for Riverside North Parking Lot are modified as described in this Addendum.

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

M I N N E S O T A D O T BID TABULATION SUMMARY JOB PAGE 1 ON 01/14/97 MINNESOTA PROJECT NO.S: DPI 015-8(021) DPI 015-8(022)

REGIONAL TRANSIT AUTHORITY PUBLIC NOTICE. IFB Rail Expansion (Streetcar) Rampart Street. Addendum IV

TOWN of LAKESHORE SITE PLAN CHECKLIST

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS

18" 1.5" 3"R 11.5" 10" 3-1/2" MINIMUM STONE CUSHION GRADATION CA-6

Charlotte County Utilities DESCRIPTION

CITY OF NEW WESTMINSTER SECTION Westminster Pier Park ADDENDUM NO. 1 Landscape Contract

EXCAVATION AND BACKFILL

WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL

CITY OF VISTA STANDARD DRAWINGS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

SECTION 2.0 PREPARATION OF MASTER PLANS, CONSTRUCTION PLANS, AND RECORD DRAWINGS

Transcription:

Addendum # 1 Date Issued: August 28, 2012 Issued By: Project: Owner: Renker Eich Parks Architects 1609 Dr. Martin Luther King Street North St. Petersburg, Florida 33704 Ph# (727) 821-2986 Fax # (727) 896-4911 tmiller@reparch.com MIRAMAR EST + HEAT FACILITY At The SNAKE CREEK TRAINING SITE CFMO NO: 211004 Department of Military Affairs Construction & Facility Management Office Post Office Box 1008 St. Augustine, FL 32085-1008 This addendum forms a part of the Contract Documents dated: August 10, 2012. This Addendum serves to clarify, revise, and supersede information in the Contract Manual and Technical Specifications, Drawings, and previously issued Addenda. Portions of the Addendum affecting the Contract Documents will be incorporated into the Contract by enumeration of the Addendum in the Owner/Contractor Agreement. All of these items are hereby incorporated into the project and made a part of the project just as though they were included in the Contract Manual and Technical Specifications, and Drawings, Construction Document Submittal Dated August 10, 2012. The Contract Manual and Technical Specifications, and Drawings, for this project are amended as follows: General Items 1.01 1. Mandatory Pre-Bid Agenda: Attached is the Mandatory Pre-Bid Agenda. 2. Mandatory Pre-Bid Sign In Sheet: Attached is the Mandatory Pre-Bid Sign In Sheet.

Addendum #1 MIRAMAR EST + HEAT FACILITY At The SNAKE CREEK TRAINING SITE Page 2 Reissued Drawings 1.02 This Addendum includes the following attached Revised/Reissued Drawings (reason: Extended Building Pad) 1. Civil Sheets - C-1 Paving Grading Drainage & Utility Plan, Addenda No1 Reissued 08.28.2012. - C-2 Utility Plan, Addenda No1 Reissued 08.28.2012. - C-3 Erosion and Sedimentation Control Plan, Addenda No1 Reissued 08.28.2012. - C-4 Details and Specifications, Addenda No1 Reissued 08.28.2012. - C-5 Details and Specifications, Addenda No1 Reissued 08.28.2012. Added Drawings 1.03 This Addendum includes the following attached Added Drawing (reason: Extended Building Pad) 1. Civil Sheets - C-5 Details and Specifications, Addenda No1 Reissued 08.28.2012. Attachments As stated above. End of Addendum #1 Attachments: As stated above Distribution: DMA/CFMO Mr. Joe Poltis Mr. Bunk Crosby Mr. Butch Hersey G:\2012\1211 EST + HEAT Miramar DMA\B and N\Addenda\ADD-01.1211.doc

W. INV ELEV. -4.50' RIM ELEV. - 6.10' PAD SHALL BE PAD TO EXTENDED AT A MINIMUM OF 4FT ONSITE THAT ALL SW. INV ELEV. - 4.75' (TYP) INSTALL TYP 'C' DB INLET RIM ELEV. - 6.25' EXISTING (TYP) INV - 4.50' 12" MES RELOCATED PAD (SEE DETAILS) AROUND EXTENSION TO BE EXISTING FENCE BE EXTENDED FOR EMT. PAD CONSTRUCTION SHALL BE BASED ON THE HEAVY DUTY PAVEMENT DETAIL AND THE TIERRA GEOTECHNICAL REPORT 6511-11-230 DATED 07/25/11. FROM THE PERIMITER WITH A MINIMUM POSITIVE SLOPE TO SLOPE OFF TO EXISTING GRADE. CONTRACTOR SHALL CONFIRM ELEVATIONS SLOPE TOWARDS DRAINAGE SYSTEM. GENERAL NOTES: EST HEAT FACILITY F.F.E. = 7.7 NGVD STORAGE ( 5,000 SF) GRADING NOTES: FOR ARCHITECTURAL PLANS DETAILS SEE MATCH GRADE EXISTING PROJECT AREA SHOWER TRAILER ADMIN GRADE MATCH EXISTING S. INV ELEV. - 5.50' RIM ELEV. - 7.00' EXISTING (TYP) TYP 'C' DB INLET ADMIN STORAGE ( 5,000 SF) SUBMITTAL SET: FOR AGENCY REVIEW AND APPROVAL B E T A J O N E S EXISTING TYP 'C' DB INLET N GRAPHIC SCALE RIM ELEV. - 6.25' EXISTING (TYP) TYP 'C' DB INLET NW. INV ELEV. - 4.75'

ADMIN W. INV: 4.5 NGVD EXISTING 6" CLEANOUT EST HEAT FACILITY F.F.E. = 7.7 NGVD STORAGE ( 5,000 SF) ARCHITECTURAL PLANS DETAILS FOR SEE 6" CLEANOUT E. INV: 5.48' NGVD S. INV: 5.48.' NGVD RIM EL.: C900 DR18FM SEWER LINE NOTES (PART 2):. TESTING: SDR 35, 70 LF @ MIN 0.4% SLOPE 6" CLEANOUT W/ 10LF OF 6" PVC SDR 35, 6" PVC W. INV: 5.00.' NGVD S. INV: 5.00' NGVD SANITARY SEWER CONNECTION N. INV: 4.70 NGVD W. INV.: 4.70 NGVD RIM EL.: 6" CLEANOUT EXISTING 6" PVC SDR 35, 20 LF WITH 6" PLUG SDR 35, 116 LF @ MIN 0.4% SLOPE 6" PVC PROJECT AREA EXISTING 2" LINE, 190 LF± EXISTING 2" SCH 40 PVC WATER EXISTING 2" PLUG WITH BLOW OFF VALVE 1.5" DIA AWWA C901 PVC WATER LINE, 32, 77, AND 55 LF, RESPECTIVELY SHOWER TRAILER ADMIN STORAGE ( 5,000 SF) 1.5" DIA AWWA C901 PVC WATER LINE, 17 AND 49 LF, RESPECTIVELY SUBMITTAL SET: FOR AGENCY REVIEW AND APPROVAL WATER LINE NOTES: 13. TESTING: SEWER LINE NOTES (PART 1): B E T A J O N E S N GRAPHIC SCALE

EROSION CONTROL NOTES: PROJECT AREA SEE ARCHITECTURAL PLANS FOR DETAILS EST HEAT FACILITY F.F.E. = 7.7 NGVD CONSTRUCTION SEQUENCE NOTES: N GRAPHIC SCALE SUBMITTAL SET: FOR AGENCY REVIEW AND APPROVAL B E T A J O N E S

A A MANHOLE INVERTS DESIGN CRITERIA FALL ACROSS MANHOLE FROM INFLUENT TO EFFLUENT OF IN LINE PIPES SHALL BE 0.041 FT. MIN. INFLUENT TO EFFLUENT PIPES THAT ARE AT AN ANGLE SHALL BE 0.10 FT. MIN. PIPES OF DIFFERENT SIZES SHALL MATCH CROWNS. (UPON SPECIAL CIRCUMSTANCES, WITH PERMISSION, THIS MAY BE REDUCED TO 0.02 FT. COMPACTION IN ROADWAYS AROUND MANHOLES COMPACTION SHALL BE IN 12" LIFTS. THE LAST 18" WILL BE LIMEROCK, 2' AROUND MANHOLE TOP COMPACTED TO 98% MAXIMUM DENSITY WITH LBR OF 100 TO THE FINISHED LIMEROCK GRADE. NO BRICK ADJUSTMENTS WILL BE ALLOWED IN ROADWAYS (ONLY GRADE RINGS WILL BE ACCEPTED). PLAN VIEW USF 170E MANHOLE FRAME & COVER FINISHED GRADE WHEN MANHOLE IS WITHIN LIMITS OF PAVEMENT 3" FINISHED GRADE WHEN MANHOLE IS OUTSIDE LIMITS OF PAVEMENT COVER SECTION "A-A" PRECAST ECCENTRIC CONE SECTION AND SIDEWALLS PER ASTM C 478 LATEST EDITION 4000 P.S.I. CONCRETE TYPE II CEMENT 8" KOR-N-SEAL BOOT W\ TYPE II LEAN CEMENT GROUT (SHOWN) 1/2"/FT 1/2"/FT FRAME SECTION "A-A" MIN. D.O.T. CLASS I, TYPE II CEMENT GROUT WITH BRICK OR RUBBLE AND TROWEL TO A SMOOTH SURFACE FINISH. GROUT SURFACE SHALL BE 1" MIN. THICKNESS OVER BRICK OR RUBBLE. MANHOLE LOCATIONS MAY IMPACT PAVING, #57 STONE SHALL BE COVERED IN A FASHION AS TO PREVENT SOIL MIGRATION INTO VOIDS WITHIN THE #57 STONE. MANHOLE FRAME AND COVER SEWER SERVICE CONNECTION AND CLEANOUT AT PROPERTY LINE THRUST BLOCK REQUIREMENTS CONTRACTOR NOTES: CONSTRUCTION NOTES: PROJECT CLOSEOUT NOTES: 10" GRANULATED AGGREGATE BASE (GAB) FDOT SECTION NO. 204 MIRAFI BXG12 GEOGRID OR APPROVED EQUAL 8" INPLACE/FILL STABILIZED SUBGRADE @ 95% DENSITY 2 HEAVY DUTY PAVEMENT N.T.S. SUBMITTAL SET: FOR AGENCY REVIEW AND APPROVAL B E T A J O N E S

TREE-PROTECTION FENCE TRENCH BACKFILL (UNPAVED AREA) SILT FENCE GATE VALVE AND VALVE BOX UTILITY CROSSING DETAIL WATER TAP AND SERVICE CONNECTION WATER MAIN CROSSING TRENCH BACKFILL (PAVED LOCAL ROAD) NOTES: 1. ALL PIPE AND FITTINGS 2" AND SMALLER SHALL BE THREADED BRASS, AS SHOWN. ALL 3" PIPE TO BE GALVANIZED STEEL. 2. ALL PIPE FITTINGS LARGER THAN 4" SHALL BE CEMENT-LINED DUCTILE IRON WITH FLANGED FITTINGS FOR ABOVEGROUND USE. MECHANICAL JOINT FITTINGS SHALL BE USED UNDERGROUND WITH RESTRAINED JOINTS AND THRUST COLLARS. 3. MEGALUGS, OR EQUAL, CAN BE USED IN PLACE OF RESTRAINED JOINTS ON ALL USED UNDERGROUND WITH RESTRAINED JOINTS AND THRUST COLLARS. 4. PAINT ALL ABOVEGROUND DUCTILE PIPING, FITTINGS AND VALVES. 5. BACKFLOW DEVICES MUST BE IN PLACE AND OPERATIONAL PRIOR TO THE INSTALLATION OF WATER METERS. SUBMITTAL SET: FOR AGENCY REVIEW AND APPROVAL B E T A J O N E S

CHAIN-LINK SECURITY FENCE DETAIL TOP OR BRACE RAIL ATTACHMENT END OR GATE POST DETAIL ROUND POST H-BEAM TENSION BAND DETAIL TRUSS ROD AND BAND BRACE RAIL CLAMP DETAILS FASTENING DETAILS H-BEAM ROUND POST LINE POST ATTACHMENTS BRACE PANEL DETAIL GROUNDING DETAIL BOTTOM RAIL DETAIL SUBMITTAL SET: FOR AGENCY REVIEW AND APPROVAL B E T A J O N E S