Single Phase Soft Starters

Similar documents
AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

SECTION AUTOMATIC TRANSFER SWITCH

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Soft starters with internal by-pass

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

CI-tronic Soft start motor controller

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

STRATO 70W LED P DESCRIPTION KEY FEATURES APPLICATIONS AND BENEFITS MODEL CODING AND OUTPUT RATINGS TRC ELECTRONICS, INC

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Instructions for D64RPB30 Series C1 Ground Fault Relay

Zelio Control Measurement Relays

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

CP-T range Product group picture

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

RE17LLBM asymmetrical flashing relay s V AC - solid state output

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

08/07/2015

HEC-45LTN-45PFAS Rev A

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

50W Constant Current (700mA) Dimming LED Driver

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Thermistor motor protection relays

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

ES-777-MV-P2_A1 03/01/10

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Power Factor (1) Efficiency (1)

SPECIFICATION FOR OVERCURRENT RELAYS

75W Constant Current (700mA) LED Driver

HEC-30/35LTA-33TDAA Rev A

HEC-40LTN-XXPSCA Rev A

RS Pro ENGLISH. Datasheet

150 C 30 F B D 8L 152H C 30 F BD 43 8L

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

08/07/2015

Switching power supplies CP range, Linear power supplies CP-L range. Content

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

FS24W Series LED Driver Input: V High Power Factor High efficiency Subminiaturization IP66 SPECIFICATIONS

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

Protection components

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

S11 Adjustable Speed Drive Engineering Specification

CP-T range Benefits and advantages

Modbus Register Map: InfraStruXure Symmetra 3-Phase Absolute Starting Register Number, (Decimal)

Power Factor (1) Efficiency (1) Parameter Min. Typ. Max. Notes A Measured at full load and 100 Vac input

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

CP-E range Benefits and advantages

Output Voltage Range ma ma 700 ma 176~305 Vac 160~357 Vdc 250W 93% 0.98 EBD-255S105DV

INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

02/11/2015

Typical Efficiency (2) Power Factor (2)

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

HEC-35LTA-XXTSAA Rev A

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ST-250MAK-05E. Switching Power Supply SPECIFICATION

RS Pro ENGLISH. Datasheet

Typical Efficiency (2)

CB Scheme UL508 UL ATEX II3G

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Compliance with CE Marking, UL Standard and CSA Standard

Installation and Operational Instructions for ROBA -switch Type 017._00.2

HEC-100RTA-48QSCA Rev A1.0

Transcription:

Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (877) 304-0724 C US

Model Nomenclature 1 2 3 4 5-9 10 11 S S 0 B 12-20 S N Type S SureStart Contactor Function P Primary 1 S Secondary 2 Nominal Voltage Rating 0 115/60/1 1 208-230/50-60/1 Vintage B Current, Single-Phase Auxiliary Alarm Relay N None Standard S Standard Full Load Amps (FLA) (Corresponds to Compressor Run Load Amps (RLA)) 12-20 (115V Single Phase) 08-16 (230V Single Phase) 16-32 (230V Single Phase) Rev.: 27 February 2014D Notes: 1 Not available in the United States. 2 Primary includes a contactor. Secondary operates in series with contactor. 04/14 2 Page of

Dimensional Data Single Phase 5.30 2.94 LED 1.96 3.80 3.80 0.65 3.16 3.16 Mounting Bracket Approved Mounting Positions 1 2 LED LED 3 4 Not Approved LED 5 6 7 8 LED 04/14 3 Page of

Physical Characteristics SureStart Model Single Phase SS0B12-20 SS1B08-16 SS1B16-32 Storage Temperature, o F [ o C] -40 [-40] to 185 [85] Case Material ABS Flameproof UL-94 V0 IP Rating IP207 Line Conductor, AWG 14-6 14-6 14-6 Line Conductor Strip Length, in. [mm] 0.47 [12] 0.47 [12] 0.47 [12] Minimum Line Conductor Length, in. [mm] 15.7 [400] 15.7 [400] 15.7 [400] Line Terminal Tightening Torque, in-lbs [N-m] 11.5 [1.3] 11.5 [1.3] 11.5 [1.3] Start Winding & Compressor Common, AWG 16-12 16-12 16-12 03/06/14 Operating Characteristics SureStart Model Single Phase SS0B12-20 SS1B08-16 SS1B16-32 Rated Voltage, VAC 115 208-230 208-230 Rated Phase 1 1 1 Rated Frequency, Hz 60 50/60 50/60 Maximum Load Current, Amps 20 16 32 Maximum Starting Current, Amps 35 35 65 Control input, VAC Auto-Start at Power Up Number of Starts/Hour (Evenly Distributed) 15 15 15 Short Circuit Current Rating (SCCR), ka 5 5 5 Shutdown on Low Voltage 98 175 175 Minimum Startup Voltage 103 180 180 Maximum High Voltage 126 253 253 Operating Ambient, o F [ o C] -4 [-20] to 140 [60] Life Expectancy (At Maximum Rated Load) Minimum 100,000 Operations 03/06/14 Software Characteristics SureStart Model Single Phase SS0B12-20 SS1B08-16 SS1B16-32 Software Fault Delay, seconds 300 300 300 Initial Power on Delay, seconds, 60 Hz [50Hz] 1 [2] 1 [2] 1 [2] Power Loss Reset, milliseconds 100 100 100 Contactor Chatter Protection Yes Yes Yes Motor Reversal Protection Yes Yes Yes Software Optimization Auto tune 10/01/13 04/14 4 Page of

SureStart Compatibility Guide Nominal Supply Voltage* Single Phase SS0B12-20 SS1B08-16 SS1B16-32 115/60/1 208-230/50-60/1 Full Load Amperage, FLA (Typical) 12-20 08-16 16-32 * - Voltage/Hz/Phase 11/21/13 Wiring Schematics RUN WINDING COMP CONT L2 T2 COMP CONT L1 T1 R C RUN CAP S RUN CAPACITOR ACTIVE (T2) START WINDING NOT USED COMPRESSOR COMMON SureStart 230V with Two Pole Contactor RUN WINDING COMP CONT L T N R C RUN CAP S RUN CAPACITOR ACTIVE (T) START WINDING NOT USED COMPRESSOR/MOTOR COMMON SureStart CAUTION: SureStart must be installed in a location that ensures that the external heat from a hot gas line, compressor discharge piping, or similar heat source will not cause damage. Minimum 3 [76mm] clearance is recommended. 115V/230V with Single Pole Contactor 04/14 5 Page of

SureStart Mode of Operation 04/14 6 Page of

SureStart Single Phase LED Flash Codes Led Flash Codes A Red LED indicator will flash under the following conditions. [NOTE: LED fault indicator is turned off in normal running mode.] a) Rapid Flash (10 / sec) : Low Voltage b) Triple Flash Every Three Seconds (3 / 3 secs): Lockout on Three Failed Starts c) Slow Flash (1 / 3 secs): Lockout on Over Current d) Slow Steady Flash (1 / sec): Cycle Delay / Fault Mode Flash Code (Rapid Flash (10 / sec) : Low Voltage) - Displayed for Low supply voltage before or after a softstart. - If Low voltage is detected before a start, a re-start is attempted after 50 seconds. - If Low voltage is detected after a start, a re-start is attempted after 3 minutes. Flash Code (Triple Flash every three seconds (3 / 3 secs): Lockout on Three Failed Starts) - Displayed after failure to start on Three consecutive start attempts. - Re-start is attempted after 50 minutes. - Standard lockout period is revised to 3 minutes after a successful start. In circumstances where the compressor may have seized or is unable to startup due to failure of other components in the HVAC system, the software will check for three consecutive failed starts. On the third sequential failed start, the program goes into Lockout for 50 mins. On failing to get a good start even after 50 mins, it will re-attempt start again after duration of 50 mins. Once a good start is eventually achieved, it will reset the hardstart counter and will require 3 failed starts again to force it back into Lockout mode. Lockout can be cleared anytime through a power reset of the SureStart device. Flash Code (Slow Flash (1 / 3 secs): Lockout on Over current) - Displayed for Overcurrent in running mode of the compressor motor. - Overcurrent limit is 25A for 08-16A version and 50A for 16-32A rated version. - Also displayed, if internal Klixon of the compressor trips out on overheat. - Re-start is attempted after 10 minutes. To limit the current in compressors from extending abnormally beyond its stated capacities, SureStart is also equipped with Overcurrent limit protection. For models rated from 16-32A, SureStart is designed to trip out in overload conditions exceeding 50A. In smaller models, it is designed to cutoff power to the compressor if the current drawn exceeds 25A. On overcurrent lockout, SureStart attempts a re-start automatically after 10 minutes. Both failed start lockout and overcurrent limit protection have been designed to prevent the compressor from drawing abnormal currents in conditions not feasible for the compressor operation. Flash Code (Slow Steady Flash (1 / sec): Cycle Delay / Fault Mode) - Displayed for Cycle delay between two consecutive softstarts or other faults mentioned below. - Re-start is attempted after a default period of 3 minutes. - Other possible reasons for this Fault mode indicator can be due to - incorrect wiring during installation, - a failed Softstart attempt, - intermittent power loss (duration longer than 100ms), - frequency out of range, or - failed run capacitor. 04/14 7 Page of

Declaration of Conformity SureStart technology has been tested and certified under the following standards that apply. For United States, Canada, & Mexico UL 508/ CSA 22.2 # 14 (ETL control # 4004190) For European Union, Australia, and other countries accepting CE Marking Low Voltage Directive (LVD) IEC/ EN 60947-4-2: Low Voltage switchgear and control gear: contactors and motor-starters IEC/ EN 60335-1 & IEC/ EN 60335-2-40: Safety requirements for electrical heat pumps, air conditioners, dehumidifiers. Electromagnetic Compliance (EMC) IEC/ EN 55014-1 Conducted & radiated emissions IEC/ EN 61000-3-11 Flicker IEC/ EN 61000-3-12 Harmonics emissions IEC/ EN 61000-3-2 Harmonic current emissions IEC/ EN 55014-2 Conducted & radiated immunity IEC/ EN 61000-6-1 Immunity for residential, light commercial, and light industrial IEC EN 61000-3-3 Voltage fluctuations IEC/ EN 61000-4-2 Electrostatic discharge (ESD) immunity test IEC/ EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test IEC/ EN 61000-4-4 Electrical fast transient/burst immunity test IEC/ EN 61000-4-5 Surge Immunity Test IEC/ EN 61000-4-6 Conducted radio-frequency immunity IEC/ EN 61000-4-11 Voltage dips, short interruptions, and voltage variations immunity tests EMC compliance tested in accordance with: ANSI C63.4 EN55022 + A1:2000 + A2:2003 CISPR16 and CISPR22 VCCI V-3/2007.04 04/14 8 Page of

Definitions Case Material SureStart enclosure material Line conductor Wiring that connects to the run winding and active terminations on single phase SureStart. Line Conductor Strip Length This is the length of insulation stripped away in order to properly insert into the SureStart. Line Terminal Tightening Torque The necessary torque needed to secure line conductors to the SureStart. Rated Voltage This is the nominal supply voltage to the SureStart. Rated Frequency This is the nominal frequency, Hz, of the power supply to the SureStart. Maximum Starting Current The maximum current at motor startup for the largest motor that can be applied to the SureStart. Control Input Any AC/DC voltage that needs to be applied in addition to active supply to SureStart. Short Circuit Current Rating This is the maximum fault current that can be applied without damaging the SureStart. Shutdown on Low Voltage SureStart will shutdown motor if the supply voltage falls below this threshold. Maximum High Voltage The maximum voltage that can be applied to SureStart. Maximum Operating Ambient The maximum temperature the SureStart can properly operate. Maximum Load Current This is the maximum current the SureStart is capable of handling. Minimum Startup Voltage SureStart will not attempt a motor start if the supply voltage is below this limit. Software Fault Delay This is the time delay that will initiate if the SureStart encounters a problem during motor operation. Initial Power Delay The time delay from when the SureStart receives power and motor start occurs. Power Loss Reset SureStart is designed to turn motor off in the event power is lost for more than this time period. Contactor Chatter Protection SureStart can detect faulty contactor conditions and shut the motor off. Motor Reversal Protection SureStart will prevent a single phase motor from reverse rotation due to intermittent power outages. Software Optimization The maximum number of starts required to achieve optimized motor starting. 04/14 9 Page of

Notes 04/14 10 Page of

Revision Guide Pages: Description: Date: By: 3 Updated Nomenclature for New Revision 22 Apr 2014 DS 4 Updated Single Phase Dimensional Drawing 22 Apr 2014 DS 5 Updated Physical and Operational Characteristics 22 Apr 2014 DS 7 Updated Operation Flow Chart 22 Apr 2014 DS 8 Added LED Flash Code Description 22 Apr 2014 DS 9 Updated Declaration of Conformity 22 Apr 2014 DS 10 Updated Definitions 22 Apr 2014 DS 5 Updated Physical and Operational Characteristics 21 Nov 2013 DS 6 Updated SureStart Compatibility Guide 21 Nov 2013 DS All Updated Model Nomenclature 10 Oct 2013 DS All First Published 26 Jun 2013 DS 04/14 11 Page of

Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (+61) 2 4229 2069 C US