PQM3000R Class A network analyzer according to EN for power quality monitoring

Similar documents
PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

PQM3000RGW Class A rack 19 power quality analyzer with Rogowski coils

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

UPM209 1/5A CT, 80A Multifunction three-phase meter

PQube 3 Specifications

PQube 3 Specifications

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Side view View from below Rear view

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

MT 560/UMT TRANSDUCER & ANALYZER

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

UMG 509-PRO. Multifunction power analyser with RCM

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

a * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD

DM-5 Power Quality Analyzer

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Data Sheet. RISH Master Record %THD

PQA823 PQA824 Rel /09/18

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Measuring transducers

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Fluke 1750 Three-Phase Power Recorder

ND40 V V. Ethernet www/ ftp / smtp. Ethernet TCP IP RS-485 USB HOST /SD CARD.

A Power Quality Interface for Low and Medium Voltage Smart Grids

MEASURING INSTRUMENTS AND TESTERS

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

ULTRA RAPID POWER QUALITY ANALYZER

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

PQA823 PQA824 Rel /01/2007

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

SOLAR300N Rel /01/10

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

1 In This Document Elspec

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Transienten. Datenspeicher

Network Analyzer for Low-, Medium- and High-Voltage Networks

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

Technical Data Sheet

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Power Quality Analyzer Topas 2000

PQA823 PQA824 Rel /03/2007

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

PLA 34. Power quality analyzer class S. User and service manual. version 1.8

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

PM5000 Series. PowerLogic PM5100, PM5300 and PM5500 series

1 In This Document Elspec

Network Analyzer for Low-, Medium- and High-Voltage Networks

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Power Meter Series PM3200 Functions and characteristics

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Power Quality Monitoring:

Energy Management Modular Smart Power Transducer Type SPT-90

MPQ1000. Handheld Power Quality Analyzer. Automatic CT recognition. Automatic connection verification. On-board data analysis

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

Choosing the Right PowerSight Model

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

T108, GPS/GLONASS/BEIDOU Time Server

METRAClip87 and 88 Clamp Multimeters

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

Power Quality Analysers

Choosing the Right PowerSight Model. Comparison Table between PowerSight models**

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Network Analyzer for Low-, Medium- and High-Voltage Networks

Energy Management Three-phase energy meter with output modules Type EM4-DIN

ELECTRICAL NETWORK RECORDER - MC 750 ELECTRICAL NETWORK ANALYZER -MC 760 ENERGY METER - MC 720 POWER METER - MC 710 MULTIFUNCTION METER - MC 740

Energy Measurement & Management

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Power Quality and Energy Measurement PEM575

Power Quality Analyzer / High Frequency Recorder

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Supervision and analyse of the electrical network EN50160 & POWER QUALITY

Power Quality and Energy Measurement PEM575

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet

Technical Data Sheet AMIK 300 / 301

Power Quality and Energy Measurement PEM735

ND40 - POWER NETWORK ANALYZER /RECORDER

Measuring centers MC7x0 series Multifunction Meter MC740

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Power analyzers and Energy Meters Power Analyzer Type WM14-96

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

AMIK 200 / 201 Technical Data Sheet

Digital Multifunction Instrument - Rish Master 3440

3 Phase Power Quality Analy er

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Transcription:

Class A network analyzer according to EN 50160 for power quality monitoring Possibility to carry out parameter recording according to EN 50160 Integrated web server for complete device management 4 GB internal memory for data recording Harmonic measurement according to IEC/EN 61000-4-7 Flicker measurement according to IEC/EN 61000-4-15 Network analyzer for power quality monitoring according to IEC/EN 61000-4-30 Class A Communication with 2 Ethernet ports RTC synchronisation by NTP or GPS Rack 19 version PQ Meters - Class A» General features is a multifunction metering device with advanced functionality features, suitable for electrical parameters measurement and power quality analysis according to EN 50160 and IEC/EN 61000-4-30. is able to store the measured values according to a programmable rate and the events when they occur. Up to 50th voltage and current harmonics, voltage, current, frequency, flicker, voltage and current THD factor, unbalance, and many more measurements to be monitored. Available for three phase 3/4 wire and single phase systems, it is provided with 3 inputs for low voltage measurement, 1 input for V4 voltage measurement, 3 current inputs, 4 analog outputs as well as 4 digital inputs for logical status of the external signals. includes two 10/100Mbit Ethernet ports for instrument remote management by the integrated web server. The digital input status can be monitored as well as the voltage and current variations. The integrated web server structure makes the instrument easy-to-use and allows a quick check of the instrument configuration and status.» Benefits is suitable for low voltage measurement. Up to 4 GB data memory for event recording, inrush current with storage of RMS values and waveforms as well as continuous recording of MIN/AVG/MA values at a preset time. Internal realtime clock synchronisation by GPS or NTP server Integrated web server for instrument management by any PC in remote mode. Voltage parameters according to EN 50160.» Applications Switchboards, gensets, motor control centers, etc. Power monitoring & control systems Individual machine load monitoring Power demand analysis and management Harmonic monitoring Remote metering and cost allocation Motor inrush current studies» Related products Current clamps Rogowski coils 1

» Specifications for IEC/EN 61000-4-30 compliance Frequency (5.1) Magnitude of supply voltage (5.2) Flicker (5.3) Supply voltage dips and swells (5.4) Voltage interruptions (5.5) ±10 mhz 42.5 Hz 57.5 Hz; 51 Hz 69 Hz ±0.1% di U din 10% 150% di U din ±5% of reading 0.2 10 P st Magnitude: ±0.2% di U din Duration: ±1 cycle Duration: ±1 cycle Unbalance (5.7) ±0.15% 0.5% 5% u 2 0.5% 5% u 0 Harmonics (5.8) IEC/EN 61000-4-7 Class I 10% 200% of Class 3 of IEC/EN 61000-2-4 The meets IEC/EN 61000-4-30 Class A requirements for: Aggregations Time Clock Uncertainty Flagging Transient Influence Quantities» Technical drawing 380 64 66.7 482.6 380 128 133.4 482.6 2

» Specifications power supply Auxiliary power voltage: Auxiliary power consumption: Fuse: Backup battery: 85...285 VAC 50/60 Hz / 65...250 VDC 17 VA max 250 VAC / 0.63 A T type delayed 3.6 V Li-Ion, 3.0 Ah (>20 min autonomy) Measurement inputs Three-phase voltage inputs for direct connection / PT: Three-phase low voltage inputs: Phase-neutral: max 580 V RMS CAT III Phase-phase: max 1000 V RMS CAT III Phase-neutral: max 4.5 V RMS Crest factor: 2 V4 voltage input for direct connection: max 150 V RMS CAT II Current inputs: according to the selected option (CTs, clamps, Rogowski coils) Wiring modes: Three phases, 4 wires, 3 currents (3.4.3) Three phases, 3 wires, 3 currents (3.3.3) Three phases, 3 wires, 2 currents (3.3.2) Single phase, 2 wires, 1 current (1.2.1) Input impedance: >3 MΩ/phase for direct voltage inputs Frequency range: 42.5...57.5 Hz / 51...69 Hz Frequency reference channel: Phase 1/Line 12 voltage Sampling: Simultaneous on all channels, 1024 samples/cycle Accuracy Three-phase voltage: ±0.1% U n over 10... 150% U n range V4 voltage: ±0.2% reading Currents: ±0.2% reading (clamp dependent) Powers: ±0.2% reading Frequency: ±10 mhz Harmonics: Class 1 (IEC/EN 61000-4-7) Internal realtime clock (RTC): < 1 s for 24h period without synchronisation < 3 ms with GPS synchronisation Calculation technique Powers: Active and reactive, four quadrants Power factor: Four quadrants Currents: Continuous sampling, 1 cycle Flicker: Compliant to IEC/EN 61000-4-15 Voltages: Compliant to IEC/EN 61000-4-30 Voltage event hysteresis: Programmable 1...25% U n Unbalance: Compliant to IEC/EN 61000-4-30 V4 voltage: Continuous sampling, 1 cycle Harmonics, THD: Component DC+1...50 compliant to IEC/EN 61000-4-7 Frequency: Compliant to IEC/EN 61000-4-30 I/O channels Digital inputs: 4 optoisolated 24 VDC 1PPS synchronisation inputs: 4 optoisolated 24 VDC ±20% Analog outputs: 4 optoisolated 4... 20 madc, max load 300 Ω Analog output reaction time: max 200 ms Memory Recording memory: Communication Ethernet ports: Protocols: Integrated router (only for instrument with integrated router): 4 GB (8 or 16 GB on request) 2 switched 10/100 Base Ethernet (IP and MAC) HTTP, HTTPS, FTP, NTP UMTS-3G/HSPA RTC synchronisation Synchronisation system: NTP and/or GPS 3

Environmental conditions Operating temperature: Storage temperature: Relative humidity: Altitude: Installation & use: Mechanical characteristics Mounting: Size: Weight: -10... +50 C -30... +70 C 95% max without condensing max 2000 m Indoor Rack 19 3U Front (L x H): 482.6 x 133.4 mm (3U) Rear (L x H x D): 380 x 128 x 215 mm 3700 g Safety standards Safety: CAT III power supply, insulation class II, 600 V Pollution degree: 2 (EN 61010-1) Protection degree: IP40 front panel, IP20 rear Directive: 2006/95/EC LV, EN 61010 EMC: 2004/108/EC EMC, EN 50081-2, EN 50082-2, EN 61326/A1, EN 55011:1998+A1:1999+A2:2002, EN 61000-6-2/-4-2/-4-3/-4-4/-4-5/-4-6/-4-11 4

15 DIGIT ORDER CODE AQA Logo A = Algodue A Language I = Italian U = English GPS device = None A = PQMGPS1 Router = None A = Integrated 2G/3G router Current inputs A = 1/5A CTs B = 3V clamps C = Rogowski coils NOTE: - Subject to change without notice - The code made up of 15 digits including the Via Passerina, 3/A - 28010 Fontaneto d Agogna (NO) - Italy - Tel.: +39 0322 89307 Fax: +39 0322 89871 sales@algodue.it - www.algodue.com 72PG01_2_201506_2