Excilamps as efficient UV VUV light sources*

Similar documents
UV GAS LASERS PREPARED BY: STUDENT NO: COURSE NO: EEE 6503 COURSE TITLE: LASER THEORY

Ultraviolet Visible Infrared Instrumentation

Plasma Efficiency and Losses for pulsed Xe Excimer DBDs at high Power Densities

Lecture 5: Introduction to Lasers

Analysing DBD Plasma Lamp Intensity versus Power Consumption Using a Push-Pull Pulsed Power Supply

ON THE IGNITION VOLTAGE AND STRUCTURE OF COPLANAR BARRIER DISCHARGES

Multi-pass Slab CO 2 Amplifiers for Application in EUV Lithography

This is an author s version published in :

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE*

APRAD SOR Excimer group -Progress Report 2011-

Control of Induction Thermal Plasmas by Coil Current Modulation in Arbitrary-waveform

arxiv:hep-ex/ v1 19 Apr 2002

Nd: YAG Laser Energy Levels 4 level laser Optical transitions from Ground to many upper levels Strong absorber in the yellow range None radiative to

Laser Induced Ignition with Resonant Multiphoton Absorption in Oxygen

THE THREE electrodes in an alternating current (ac) microdischarge

Vertical External Cavity Surface Emitting Laser

EUVL Activities in China. Xiangzhao Wang Shanghai Inst. Of Opt. and Fine Mech. Of CAS. (SIOM) Shanghai, China.

Couplings between a resonant current source power supply and a DBD excilamp

event physics experiments

6 - Stage Marx Generator

High Power CO 2 Laser, EUVA

Scintillation Counters

Laser-Produced Sn-plasma for Highvolume Manufacturing EUV Lithography

Enhancement of Non-Equilibrium Atmospheric Pressure He Plasma Discharges by Using Silicon Diode for Alternating Current

The KrF alternative for fast ignition inertial fusion

Characteristics of a Normal Glow Discharge Excited by DC Voltage in Atmospheric Pressure Air

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 18.

Measurements of high voltage pulses with subnanosecond rise time

THE COST of current plasma display panel televisions

High power VCSEL array pumped Q-switched Nd:YAG lasers

A simple and compact high-voltage switch mode power supply for streak cameras

SYNCHRONIZABLE HIGH VOLTAGE PULSER WITH LASER-PHOTOCATHODE TRIGGER

Design and Construction of a High Energy, High Average Power Nd:Glass Slab Amplifier. Dale Martz Department of Electrical & Computer Engineering

Development of Ultrashort Pulsed VUV Laser and its Applications

SPECIAL EXCIMER LASERS

Design Guidelines for a Copper Halide Laser

Enable Highly-Stable Plasma Operations at High Pressures with the Right RPS Solution

Terahertz Radiation of a Low-inductance Discharge in Vacuum with Laser-plasma Initiation

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

Drive Beam Photo-injector Option for the CTF3 Nominal Phase

Japan Update. EUVA (Extreme Ultraviolet Lithography System Development Association) Koichi Toyoda. SOURCE TWG 2 March, 2005 San Jose

Density and temperature maxima at specific? and B

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

A Study on Enhancement of Ozone Gas Concentration using Microcontroller based PWM Circuit

IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 38, NO. 10, OCTOBER

Investigation of an atmospheric pressure radio-frequency capacitive plasma jet

PELHAM RESEARCH OPTICAL L.L.C.

Measurement of the Speed of Light in Air

Making 1 MW cw HF practical

New Color-Enhancing Discharge Mode Using Self-Erasing Discharge in AC Plasma Display Panel

ELECTRICAL CHARACTERIZATION OF ATMOSPHERIC PRESSURE DIELECTRIC BARRIER DISCHARGE IN AIR

Volume 44, number 2 OPTICS COMMUNICATIONS 15 December 1982

Multi-Lamp Microwave UV Systems Physics and Technology

Analysis of discharge parameters and optimization study of coaxial DBDs for efficient excimer light sources

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

Power scaling of picosecond thin disc laser for LPP and FEL EUV sources

3.6 An Ultra-Stable Nd:YAG-Based Laser Source. 8. Jayatna Venkataraman (private communication). ACKNOWLEDGMENT

Optodevice Data Book ODE I. Rev.9 Mar Opnext Japan, Inc.

Advanced post-acceleration methodology for pseudospark-sourced electron beam

INVESTIGATION OF PULSED MICRO-DISCHARGES AND OZONE PRODUCTION BY DIELECTRIC BARRIER DISCHARGES

A large area VHF plasma source for atmospheric air plasma treatment of coated surfaces

SOLID-STATE SWITCHING MODULATOR R&D FOR KLYSTRON

AC BARRIER PIN-PLANE CORONA: SIMILARITIES AND DISTINCTIONS TO DC POSITIVE AND NEGATIVE CORONAS AND DIELECTRIC BARRIER DISCHARGE

Plasma Sheath Velocity and Pinch Phenomenal Measurements in TPF-II Plasma Focus Device

COMPONENTS OF OPTICAL INSTRUMENTS. Chapter 7 UV, Visible and IR Instruments

COMPONENTS OF OPTICAL INSTRUMENTS. Topics

High Average Power, High Repetition Rate Side-Pumped Nd:YVO 4 Slab Laser

Pulse Niru Company. General Catalogue.

Study on Glow Discharge Plasma Used in Polyester. surface modification

Far infrared generation by CO 2 lasers frequencies subtraction in a ZnGeP 2 crystal.

II. PHASE I: TECHNOLOGY DEVELOPMENT Phase I has five tasks that are to be carried out in parallel.

Improved Radiometry for LED Arrays

the physics of different light sources incandescence and blackbody radiation the concept of photons

The Absolute Detection Efficiency of Vacuum Electron Multipliers, to kev Protons and Ar + Ions.

RAVEN, A 5 kj, 1.5 MV REPETITIVE PULSER* G. J. Rohwein Sandia National Laboratories Albuquerque, New Mexico 87185

Fiber Lasers for EUV Lithography

A Low Impedance Marx Generator as a Test bed for Vacuum Diodes

Design and Construction of a150kv/300a/1µs Blumlein Pulser

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Lecture 5. Optical Lithography

Removal of diesel soot particules using an esp supplied by a hybrid voltage

Introduction Fundamentals of laser Types of lasers Semiconductor lasers

SCCH 4: 211: 2015 SCCH

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

Femtosecond laser microfabrication in. Prof. Dr. Cleber R. Mendonca

R a pulsed, supersonically-expanding gas has been reported

Fiber Coupled Semiconductor Laser

Q-switched resonantly diode-pumped Er:YAG laser

High-Density Helicon Plasma Thrusters Using Electrodeless Acceleration Schemes

Plasma Generators

LEP Optical pumping

SIPP 2011 / UKM Ouargla / February/Février 2011

Thin-Disc-Based Driver

DESPITE their predominant position in the flat-panel largescreen

Highly efficient SERS nanowire/ag composites

The Design of Double YAG Laser Implement Controlled by Industrial Computer

RF discharge at medium and high pressure & its possibilities for material surface modification

Powerful Single-Frequency Laser System based on a Cu-laser pumped Dye Laser

Design and Analysis of Resonant Leaky-mode Broadband Reflectors

Transcription:

Pure Appl. Chem., Vol. 74, No. 3, pp. 465 469, 2002. 2002 IUPAC Excilamps as efficient UV VUV light sources* Victor F. Tarasenko High Current Electronics Institute, 4, Akademichesky Ave., Tomsk, 634055, Russia Abstract: Operating parameters of powerful UV and vacuum ultraviolet (VUV) excilamps with different discharge geometry excited by capacitive discharge, barrier discharge, glow discharge, and UV-preionized discharge were investigated. Intense radiation of Ar 2 *, Kr 2 *, Xe 2 *, ArF*, KrBr*, KrCl*, KrF*, XeI*, Cl 2, XeBr*, XeCl*, XeF* molecules and I* atoms was obtained in rare gas or in rare gas F 2 (Br 2, CH 3 Br, Cl 2, Br 2, HCl, I 2, NF 3 ) mixtures. INTRODUCTION In recent decades, interest in design and development of new types of UV and VUV spontaneous radiation sources, in particular excilamps, has considerably grown [1 18]. The most efficient excilamps on transitions of rare gas dimers R* 2 and rare gas monohalides RX* can find wide industrial application. Therefore, improving their output parameters is of great importance. In this paper, output parameters of excilamps with different geometry pumped by capacitive discharge, barrier discharges, glow discharges, and UV-preionized discharge are presented. The paper reviews some results obtained at the HCEI [8 18]. EXPERIMENTAL SETUP Designs of the cylindrical, coaxial (Fig. 1) and planar excilamps excited by barrier and capacitive discharge under study are described in [12,16,18]. Two types of pulsed generators were used for capacitive and barrier discharge formation. The first one produces sinusoidal voltage pulses with amplitude up to 10 kv and pulse repetition rate up to 100 khz. In the second case, unipolar wave thyristor (or tranzistor), magnetic generators were used. The Fig. 1 Schematic diagram of electrodeless excilamps [capacitive (a) and barrier (b)]. 1 solid electrodes; 2 perforated electrodes; 3 discharge volume; 4 quartz envelopes. *Lecture presented at the 15 th International Symposium on Plasma Chemistry, Orléans, France, 9 13 July 2001. Other presentations are presented in this issue, pp. 317 492. 465

466 V. F. TARASENKO generators provided voltage pulses with duration from 20 ns to 10 µs. A pulse repetition rate was up to 100 khz. The cylindrical and coaxial glow discharge excilamps (Fig. 2) were made from high-quality quartz tubes [10 12,14,15,17]. Diameter of the tubes was 10 60 mm and their length was up to 90 cm. The gap between the tubes in coaxial excilamp varied from 2.5 to 8 mm. Water-cooling of the inner tube or electrodes was used. The electrodes of glow discharge excilamps were coupled to dc power supply providing discharge current up to 1 A and voltage across the discharge gap up to 10 kv. AC power supply voltage was used in some experiments. The coaxial of barrier discharge and cylindrical of capacitive discharge excilamp (Fig. 2) were made from quartz tubes of high quality. There were three types of pulsed excilamps in experiments with short pulse duration: such as a cylindrical glow discharge lamp, capacitive discharge lamp (electrodeless excilamp), and high pressure of volume discharge planar lamp with UV-preionization of discharge gap (Fig. 3) [8]. Average output and pulsed power were measured by photocathode FEK-22SPU. Excilamp spectra were recorded by monochromator MDR-23, equipped with photomultiplier FEU-100 or vacuum monochromator VMR-2 with 600 hatch/mm grating. The photomultiplier was connected to amplifier and registering system. Fig. 2 Schematic diagram of cylindrical (a) and coaxial (b) excilamps. Electrodes (1), quartz tubes (2), and discharge region (3) are designated. Fig. 3 Simplified diagram of UV-preionized self-sustained discharge excited lamp: 1 solid electrode; 2 peaking capacitors; 3 causing; 4 window; 5 spark gaps for preionization; 6 grid electrode; D output window diameter; d operation gap size. RESULTS The operating parameters of powerful pulsed excilamps with different discharge geometry pumped by capacitive discharge, barrier discharge, glow discharge, and UV-preionized discharge were studied.

Excilamps as efficient UV VUV light sources 467 Intense radiation of Ar 2, Kr 2, Xe 2, ArF*, KrBr*, KrCl*, KrF*, XeI*, XeBr*, XeCl*, XeF*, Cl 2 *, Br 2 *, I 2 *, IBr* molecules and I* atoms was obtained in rare gas or in rare gas Cl 2 (Br 2, CH 3 Br, F 2, HCl, I 2, NF 3 ) mixtures [8 18]. The best results are as follows below. An efficient low-pressure sealed-off cylindrical excilamp with capacitive discharge excitation was developed. Investigation was made of the characteristics of XeCl (λ ~ 308 nm), XeBr (λ ~ 282 nm), KrCl (λ ~ 222 nm), and XeI (λ ~ 253 nm) excilamps. High efficiency of exciplex molecules and simple design were obtained under capacitive HF discharge excitation. High UV radiation power and electrical power deposition to fluorescence conversion resulted in efficiencies of up to 15 %. When the tube operates on Xe I 2 mixture in addition to B X band of XeI* molecules (λ ~ 253 nm) band of I 2 * molecules at λ ~ 342 nm and narrow (70 pm) resonant line of I* at λ = 206.16 nm were observed in glow discharge spectra. Output power up to 10 W and efficiency about 10 % were obtained. Gas mixture He(Ne) Xe(Kr,Ar) Cl 2 (HCl, Br 2, I 2, F 2, NF 3 ) at pressure of 0.1 1 atm was used in coaxial excilamps with barrier discharge excitation. UV output power and efficiency of 80 W and 10 %, respectively, at λ 222 nm were obtained under excitation by pulses with frequency of 100 khz. The lifetime of gas mixture in KrCl*, XeCl*, XeI* capacitive discharge and barrier discharge excilamps over 1000 h was demonstrated. Coaxial excilamp pumped by a glow discharge with the gap of 8 mm was found to emit the highest average power. Output power at λ 222 nm up to 200 W (specific output power P sp = 1 W/cm 3 ) was obtained (Fig. 4). Efficiency with respect to input power as high as 14 % was demonstrated. Similar results were obtained in Xe Cl 2 mixture at λ 308 nm. Output power of about 500 W was demonstrated when three excilamps operated in parallel. It was shown that the efficiency of luminescence of exciplex molecules KrCl* up to 25 % can be obtained in high-voltage glow discharge and positive column of glow discharge. Operation time of the excilamp is limited due to its overheating and exhaust of chlorine molecules. It is significant that enlargement of excilamp dimensions can substantially increase the operation time. Besides, upgrading of excilamp design, using stable to halogen action materials, cleaning of the original gas components, and improvement in water cooling show promise of substantial increase of the mixture lifetime. Excilamps with high-pulsed power and short pulse have been developed. The effect of input electric power on the efficiency of the exciplex molecule luminescence was studied. The possibility of creation of capacitive discharge excilamps with short pulse duration was examined. In capacitive dis- Fig. 4 Output power and efficiency of KrCl-coaxial excilamp pumped by normal glow discharge vs. discharge current. The gap is 8.5 mm. Mixture Kr:Cl 2 = 10:1, p = 6 Torr.

468 V. F. TARASENKO charge cylindrical KrCl-excilamp, at λ ~ 222 nm the radiation pulse power up to 2.5 kw was obtained. Powerful radiation pulses of 50 ns in duration were obtained at pulse repetition rate of 1 khz. In cylindrical longitudinal excilamp with inner electrodes at Xe I 2 mixture the total pulse power of 75 kw was measured. Under pumping by UV-preionized high-pressure volume discharge maximal pulsed radiation densities of 5 kw/cm 2 were obtained in mixtures Ne Kr HCl (λ ~ 222 nm) and He Kr F 2 (λ ~ 250 nm). Figure 5 shows the typical waveforms of current and lamp intensity. Fig. 5 Typical waveforms of current (a) and lamp intensity (b) in cases of electrodeless excilamp (I) and excilamp with additional UV-preionization of discharge gap (II). I Mixture Kr:Cl 2 = 25:0.5 Torr. II Mixture Ne:Kr:Cl 2 = 2 atm:45:2 Torr. Solid electrode diameter is equal to 40 mm; gap 29 mm. Ug = 36 kv, Cg = 4.2 nf. CONCLUSION Design and operating parameters of powerful UV and VUV excilamps with different discharge geometry pumped by glow discharge, high-pressure volume discharge with UV-preionization, capacitive discharge, barrier discharge were investigated. Intense radiation of Ar 2 *, Kr 2 *, Xe 2 *, ArF*, KrBr*, KrCl*, KrF*, XeI*, Cl 2 *, XeBr*, XeCl*, and XeF* molecules was obtained in rare gas or in rare gas F 2 (CH 3 Br, Cl 2, HCl, I 2, NF 3 ) mixtures [8 18]. Excilamps with high spatial uniformity of the output, narrow emission line, and long gas lifetime were developed. The lifetime of gas mixture in KrCl*, XeCl*, XeI* capacitive and barrier discharge excilamps over 1000 h was demonstrated. It was shown that efficiency of luminescence of exciplex molecules KrCl* of about 25 % can be obtained in highvoltage glow discharge and positive column of glow discharge. Output at λ 222 and 308 nm up to 200 W from single excilamp and 500 W from three excilamps operating in parallel was demonstrated. High efficiency (15 %) of exciplex molecules and simple design was obtained under capacitive HF discharge excitation. Under pumping by UV-preionized high-pressure volume discharge maximal pulsed radiation densities of 5 kw/cm 2 were obtained in mixtures Ne Xe HCl (λ ~ 308 nm) and He Kr F 2 (λ ~250 nm). ACKNOWLEDGMENT We gratefully acknowledge the ISTC support Project #1270 in new works on development and application of UV and VUV excilamps. REFERENCES 1. B. Eliasson and U. Kogelschatz. IEEE Trans. on Plasma Science 19, 309 (1991). 2. Science and Technology of Light Sources, Proc. of the 7th Int. Symp LS-7, Kyoto, Japan, August 27 31, (1995).

Excilamps as efficient UV VUV light sources 469 3. J.-Y. Zhang and I. W. Boyd. J. Appl. Phys. 80, 633 (1996). 4. Z. Falkenstein and J. J. Coogan. J. Phys. D: Appl. Phys. 30, 817 (1997). 5. Science and Technology of Light Sources, Proc. of the 8 th Int. Symp LS-8, Greifswald, Germany, August 30 September 3 (1998). 6. R. P. Mildron and R. J. Carman. J. Phys. D: Appl. Phys. 34, L1 (2001). 7. Science and Technology of Light Sources, Proc. of the 8 th Int. Symp LS-9, Ithaca, USA, 13 16 August (2001). 8. B. A. Koval, V. S. Skakun, V. F. Tarasenko, E. A. Fomin, E. B. Yankelevitch. Pribori i Tech. Experiment. 4, 244 (1992). 9. A. A. Kuznetsov, V. S. Skakun, V. F. Tarasenko, E. A. Fomin. Pisma Zh. Tech. Fiz. 19, 1 (1993). 10. A. M. Boichenko, V. S. Skakun, V. F. Tarasenko, E. A. Fomin, S. I. Yakovlenko. Laser Physics. 3, 838 (1993). 11. A. N. Panchenko, V. S. Skakun, E. A. Sosnin, V. F. Tarasenko, M. I. Lomaev. Pisma v Zh. Tech. Fiz. 21, 77 (1995). 12. A. N. Panchenko, V. S. Skakun, E. A. Sosnin, V. F. Tarasenko. Atmos. Oceanic Optics. 9, 199 (1996). 13. A. M. Boichenko, A. N. Panchenko, V. F. Tarasenko, S. I. Yakovlenko. Kvant. Elektr. 23, 417 (1996). 14. M. I. Lomaev, A. N. Panchenko, V. S. Skakun, E. A. Sosnin, V. F. Tarasenko, M. G. Adamson, B. R. Myers, F. T. Wang. Laser Particle Beams 15, 339 (1997). 15. A. N. Panchenko, E. A. Sosnin, V. F. Tarasenko. Zh. Tech. Fiz. 67 (1), 78 (1997). 16. V. F. Tarasenko, E. B. Chernov, M. V. Erofeev, M. I. Lomaev, A. N. Panchenko, V. S. Skakun, E. A. Sosnin, D. V. Shitz. Appl. Phys. A 69, S327 (1999). 17. A. N. Panchenko, E. A. Sosnin, V. F. Tarasenko. Opt. Comm. 166, 249 (1999). 18. M. I. Lomaev, V. S. Skakun, E. A. Sosnin, V. F. Tarasenko, D. V. Shitz. Pisma v Zh. Tech. Fiz. 25, 27 (1999).