Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Similar documents
Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Technical data. Safety notes

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Technical data sheet. Technical data. Safety notes

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Power consumption In operation At rest For wire sizing

Functional data Factory settings Variable Settings

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data. Parameterisable damper actuator in the

Power consumption Operation At rest Wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Brief description. Type overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Type overview. Technical data

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

GMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Rotary gear motor series AG8...

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Adaptive control system for duct and room pressure applications. Table of Contents

Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes

Rotary actuators for ball valves

Electromotoric actuators

Configured air damper actuators 6FU11xx-xDxxx-xxxx

M7061 ROTARY VALVE ACTUATORS

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DN [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rotary actuators for ball valves

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP6. Final Control Elements

Rotary actuators for ball valves

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Non-Spring Return EconoDrive Proportional Actuator

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Rotary actuators for ball valves

Rotary actuators for ball valves

Rotary actuators for ball valves

Electromotoric actuators for valves

Room Temperature Controllers. for heating and cooling systems

Spring Return DuraDrive Proportional Actuator

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

CR24-.. Single room controllers

Type 3374 Electric Actuator

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Technote. Actuator Frese OPTIMA. Application. Features actuator DN15-DN32. Features actuator DN40-DN50. Approval.

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Electromotoric actuators for stroke valves

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

Electronic Air / Fuel Ratio Control System

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power supply CP-D 24/1.3

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

NRT 105: Electronic fan-coil controller, equiflex

Actuators for modulating control AME 85, AME 86

Power supply CP-E 24/0.75

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Power supply CP-E 24/2.5

Non-Spring Return DuraDrive Modulating Actuator

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Power supply CP-E 24/20.0

Wireless Room Thermostat Installation and Operation Y6630D1007

Transcription:

echnical data sheet Rotary actuator LRA Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC... 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage AC... 4 V, 5/6 Hz Power supply range AC 85... 65 V Power consumption In operation At rest For wire sizing.5 W at nominal torque.4 W 4 VA Connection Cable m, x.75 mm Parallel connection Possible, note performance data Functional data orque (nominal torque) Min. 5 Nm at nominal voltage Manual override Gearing latch disengaged with pushbutton (temporary-permanent) Running time 9 s / 9 Noise level Max. 5 db (A) (without the valve) Position indication Mechanical, add-on Safety Protection class II otally insulated Degree of protection IP54 in any mounting position EMC Low voltage directive CE according to 89/6/EEC CE according to 7//EWG Mode of operation ype (to EN 67-) Rated impulse voltage 4 kv (to EN 67-) Control pollution degree (to EN 67-) Ambient temperature range... 5 C Media temperature 5... C in (control) ball valve C with stem heating upon request Non-operating temperature 4... 8 C Ambient humidity range 95% r.h., non-condensating (to EN 67-) Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page Weight Approx. 55 g Safety notes he rotary actuator has been designed for use in stationary heating, ventilation and air conditioning systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Caution power supply voltage It may only be installed by suitably trained personnel. All applicable legal or institutional installation regulations must be complied with. he switch for changing the direction of rotation may only be operated by authorized personnel. he direction of rotation must not be reversed in a frost protection circuit. he device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. he cable must not be removed from the device. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. www.belimo.com

LRA Rotary actuator AC... 4 V, 5 Nm Product features Simple direct mounting Straightforward direct mounting on the ball valve with only one screw. he assembly tool is integrated in the plug-on position indicator. he mounting position in relation to the ball valve can be selected in 9 steps. Adjustable angle of rotation High functional reliability Adjustable angle of rotation with mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Accessories Electrical installation Notes Caution power supply voltage Parallel connection of other actuators possible. Note performance data. Direction of rotation switch is covered. Factory setting: Direction of rotation Description Wiring diagram Open-close control -point control N L N L Data sheet Electrical accessories Auxiliary switch S..A.. - S..A.. Feedback potentiometer P..A.. - P..A.. Direction of rotation Y Rotary actuator Rotary valve A AB = % Y Dimensions [mm] Dimensional diagrams 5 7 84 R65 4 Further documentations Complete overview of actuators for water solutions Data sheets for ball valves Installation instructions for actuators and/or ball valves Notes for project planning (hydraulic characteristic curves and circuits, installation regulations, commissioning, maintenance etc.) www.belimo.com 5-LRA en v..6 Subject to changes

R..A.. / LR..A.. / NR..A.. / SR..A.. 774-.D 4 Z M4 A A AB = % A AB = % B AB = % AB A AB B 5 A AB = % www.belimo.com -R..A../LR..A../NR..A../SR..A.. v.. /

R..A.. / LR..A.. / NR..A.. / SR..A.. N L N L Y Y AC 4 V / DC 4 V S S S...% LR4A SR4A NR4A LR4A-S SR4A-S NR4A-S AC... 4 V N L L N L L S S S S S S S S S...% LRA SRA NRA LRA-S SRA-S NRA-S AC 4 V / DC 4 V Y U DC ()... V DC... V Y U DC ()... V MP 5 5 RC4A-SR LR(C)4A-SR NR(C)4A-SR SR4A-SR LR4A-MF NR4A-MF SR4A-MF LR4A-MP SR4A-MP NR4A-MP WORKS AC 4 V / DC 4 V V MF MF p MF MF / -R..A../LR..A../NR..A../SR..A.. v.. www.belimo.com

R..A.. / LR..A.. / NR..A.. / SR..A.. Z 764-.A A AB A B AB www.belimo.com -Z-R..A../LR..A../NR..A../SR..A.. v.. /