SECTION MECHANICAL IDENTIFICATION

Similar documents
SECTION MECHANICAL IDENTIFICATION

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

Industrial Pipe Marking

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

Piping & Equipment Identification

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

A. Product Data: For each electrical identification product indicated.

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION MECHANICAL IDENTIFICATION

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

SECTION MECHANICAL IDENTIFICATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

1. ASME A Scheme for the Identification of Piping Systems.

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION ELECTRICAL IDENTIFICATION

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

SECTION COMMON WORK RESULTS FOR HVAC

SECTION IDENTIFICATION DEVICES

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

IDENTIFICATION DEPOT, INC. 206 East Second Street Washington, NC PHONE FAX

U of I Facilities Standards Updates for 2017

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

SECTION SIGNAGE

SECTION ELECTRICAL IDENTIFICATION

1. State that all workmanship must conform to all pertinent laws, ordinances and regulations of all bodies having jurisdiction.

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

2012 IMC Performing Commercial Mechanical Inspections

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

Technical Development Program

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

ADDENDUM NO. 4 November 15, Page 1

Facility Services Subgroup Preface for Divisions 21` through 28

A. Submit properly identified manufacturer's literature before starting work.

This specification describes the minimum requirements for piping systems for the following service:

Residential Construction Checklist Single and Two Family Construction

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

SECTION IDENTIFYING DEVICES

SECTION LOW PRESSURE DUCTWORK

This specification describes the minimum requirements for piping systems for the following service:

Heat Exchanger Construction Checklist

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

Design Deliverables. Summary. A. Expectations for Design Deliverables:

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

SECTION INTERIOR SIGNAGE

DIVISION 6 WOOD AND PLASTICS

BUILDING PLAN REVIEW REQUIREMENTS

SECTION PROJECT COORDINATION VIA BIM

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Electrical Identification

A. It is preferred that all submittals to be submitted electronically in PDF format.

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

Page PRODUCT DESCRIPTION

CHAPTER 6 DUCT SYSTEMS

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

TO WHOM IT MAY CONCERN:

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

A. This Section includes plumbing fixtures and related components.

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

Design and Construction Standards SECTION ATHLETIC LOCKERS

SECTION CABLE TRAYS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

B. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits.

This specification describes the minimum requirements for piping systems for the following service:

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SECTION BULLET- RESISTANT DOORS

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

OCPS Submittal Register for Product Data and Shop Drawing Reviews

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

SECTION SHEET METAL FLASHING AND TRIM

SECTION BATHROOM ACCESSORIES

*********************************************************************************************************

Basic Principles and Operation of Transformer

This specification describes the minimum requirements for piping systems for the following service:

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

SECTION IDENTIFYING DEVICES

Installation Instructions Student 101 Fume Cupboard

SECTION TRANSFORMERS

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Page PRODUCT DESCRIPTION

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

Transcription:

PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections: 1. Section 15050 Basic Mechanical Materials and Methods. 2. Other Division 15 specifications as applicable. 1.2 SUMMARY A. This Section includes mechanical identification materials and devices. 1.3 SUBMITTALS A. Product Data: For identification materials and devices. B. Samples: Of color, lettering style, and graphic representation required for each identification material and device. C. Valve Schedules: For each piping system. Reproduce on standard-size bond paper. Tabulate valve number, piping system, system abbreviation as shown on tag, room or space location of valve, and variations for identification. Mark valves intended for emergency shutoff and similar special uses. Besides mounted and laminated copies, furnish copies for maintenance manuals. D. Equipment Nameplates: List of equipment and nameplate text. 1.4 QUALITY CONTROL A. Comply with ASME A13.1, "Scheme for the Identification of Piping Systems" for lettering size, length of color field, colors, and viewing angles of identification devices. 1.5 SEQUENCING AND SCHEDULING A. Coordinate installation of identifying devices with completion of covering and painting of surfaces where devices are to be applied. B. Install identifying devices before installing acoustical ceilings and similar concealment. PART 2 - PRODUCTS 2.1 IDENTIFYING DEVICES AND LABELS Page 1 of 6

A. General: Products specified are for applications referenced in other Division 15 Sections. If more than single type is specified for listed applications, selection is Installer's option. B. Equipment Nameplates: Plastic-laminate permanently fastened to equipment with data engraved or stamped. 1. Data: Manufacturer, product name, model number, serial number, capacity, operating and power characteristics, labels of tested compliances, and essential data. 2. Location: Accessible and visible. 3. Nameplates shall be provided for air handling units, fans, compressors, pumps, boilers, chillers, condensing units, motors, motor controls, safety switches, starters, controllers, panelboards, remote control pushbuttons, and alarms. Nameplates shall also be provided special or separate items of temperature control, but not room thermostats. C. Stencils: Standard stencils, prepared with letter sizes conforming to recommendations of ASME A13.1. Minimum letter height is 1-1/4 inches for ducts, and 3/4 inch for access door signs and similar operational instructions. 1. Material: Fiberboard. 2. Material: Brass. 3. Stencil Paint: Exterior, oil-based, alkyd gloss black enamel, unless otherwise indicated. Paint may be in pressurized spray-can form. 4. Identification Paint: Exterior, oil-based, alkyd enamel in colors according to ASME A13.1, unless otherwise indicated. D. Snap-On Plastic Pipe Markers: Manufacturer's standard preprinted, semirigid, snap-on type. Include color-coding according to ASME A13.1, unless otherwise indicated. E. Pressure-Sensitive Pipe Markers: Manufacturer's standard preprinted, color-coded, pressure-sensitive, vinyl type with permanent adhesive. F. Pipes with OD, Including Insulation, Less Than 6 Inches: Full-band pipe markers, extending 360 degrees around pipe at each location. G. Pipes with OD, Including Insulation, 6 Inches and Larger: Either full-band or strip-type pipe markers, at least 3 times letter height and of length required for label. H. Lettering: Use piping system terms indicated and abbreviate only as necessary for each application length. 1. Arrows: Either integrally with piping system service lettering, to accommodate both directions, or as separate unit, on each pipe marker to indicate direction of flow. I. Plastic Duct Markers: Manufacturer's standard laminated plastic, in the following color codes: 1. Green: Cold-air supply. 2. Yellow: Hot-air supply. 3. Blue: Exhaust, outside, return, and mixed air. Page 2 of 6

4. Hazardous Material Exhausts: Use colors and designs recommended by ASME A13.1. 5. Terminology: Include direction of airflow; duct service such as supply, return, and exhaust; duct origin, duct destination, and design flow. J. Plastic Tape: Manufacturer's standard color-coded, pressure-sensitive, self-adhesive, vinyl tape, at least 3 mils thick. 1. Width: 1-1/2 inches on pipes with OD, including insulation, less than 6 inches; 2-1/2 inches for larger pipes. 2. Color: Comply with ASME A13.1, unless otherwise indicated. K. Valve Tags: Stamped or engraved with 1/4-inch letters for piping system abbreviation and 1/2-inch sequenced numbers. Include 5/32-inch hole for fastener. 1. Material: 18 gauge polished brass. 2. Size: 1-1/2-inches diameter, unless otherwise indicated. 3. Shape: Round. 4. Letter Color: Black 5. Terminology: Each valve shall have an identifying letter designating the system and an identifying number designating the unit. Identifying letter for various systems shall be, for example: HWS, HWR, CWS, CWR, CDWS, CDWR, D (drain), etc. L. Access Panel Markers: 1/16-inch- thick, engraved plastic-laminate markers, with abbreviated terms and numbers corresponding to concealed valve. Provide 1/8-inch center hole for attachment. M. Valve Charts and Diagrams: Drawings, listing and showing all valves shall be provided in duplicate. Diagrams shall be floor plans with valve locations shown and valve identification numbers identified. The chart shall designate the location and service of each valve. N. Valve Diagram Frames: Glazed display frame for removable mounting on masonry walls for each page of valve charts and diagrams. Include screws. 1. Frame: Finished hardwood. 2. Frame: Extruded aluminum. 3. Glazing: ASTM C 1036, Type I, Class 1, Glazing quality B, 2.5-mm, singlethickness glass. O. Engraved Plastic-Laminate Signs: ASTM D 709, Type I, cellulose, paper-base, phenolicresin-laminate engraving stock; Grade ES-2, black surface, black phenolic core, with white melamine subcore, unless otherwise indicated. Fabricate in sizes required for message. Provide holes for mechanical fastening. 1. Engraving: Engraver's standard letter style, of sizes and with terms to match equipment identification. 2. Thickness: 1/16 inch, for units up to 20 sq. in. or 8 inches in length, and 1/8 inch (3 mm) for larger units. 3. Fasteners: Self-tapping stainless-steel screws or rivets. Page 3 of 6

P. Plastic Equipment Markers: Manufacturer's standard laminated plastic, in the following color codes: 1. Green: Cooling equipment and components. 2. Yellow: Heating equipment and components. 3. Brown: Energy reclamation equipment and components. 4. Blue: Equipment and components that do not meet criteria above. 5. Hazardous Equipment: Use colors and designs recommended by ASME A13.1. 6. Terminology: Match schedules as closely as possible. Include the following: a. Name and plan number. b. Equipment service. c. Design capacity. d. Other design parameters such as pressure drop, entering and leaving conditions, and speed. 7. Size: 2-1/2 by 4 inches for control devices, dampers, and valves; 4-1/2 by 6 inches for equipment. Q. Plasticized Tags: Preprinted or partially preprinted, accident-prevention tags, of plasticized card stock with mat finish suitable for writing. 1. Size: 3-1/4 by 5-5/8 inches. 2. Fasteners: Brass grommets and wire. 3. Nomenclature: Large-size primary caption such as DANGER, WARNING, CAUTION, or DO NOT OPERATE. R. Lettering and Graphics: Coordinate names, abbreviations, and other designations used in mechanical identification with corresponding designations indicated. Use numbers, letters, and terms indicated for proper identification, operation, and maintenance of mechanical systems and equipment. 1. Multiple Systems: Identify individual system number and service if multiple systems of same name are indicated. PART 3 - EXECUTION 3.1 LABELING AND IDENTIFYING PIPING SYSTEMS A. Install pipe markers on each system. Include arrows showing normal direction of flow. B. Marker Type: Stenciled markers with painted, color-coded bands or rectangles. C. Marker Type: Stenciled markers complying with ASME A13.1. D. Marker Type: Plastic markers, with application systems. Install on pipe insulation segment where required for hot, non-insulated pipes. E. Fasten markers on pipes and insulated pipes smaller than 6 inches OD by one of following methods: 1. Snap-on application of pre-tensioned, semi-rigid plastic pipe marker. 2. Adhesive lap joint in pipe marker overlap. 3. Laminated or bonded application of pipe marker to pipe or insulation. Page 4 of 6

4. Taped to pipe or insulation with color-coded plastic adhesive tape, not less than 3/4 inch wide, lapped a minimum of 1-1/2 inches at both ends of pipe marker, and covering full circumference of pipe. F. Fasten markers on pipes and insulated pipes 6 inches in diameter and larger by one of following methods: 1. Laminated or bonded application of pipe marker to pipe or insulation. 2. Taped to pipe or insulation with color-coded plastic adhesive tape, not less than 1-1/2 inches wide, lapped a minimum of 3 inches at both ends of pipe marker, and covering full circumference of pipe. 3. Strapped to pipe or insulation with manufacturer's standard stainless-steel bands. G. Locate pipe markers and color bands where piping is exposed in finished spaces; machine rooms; accessible maintenance spaces such as shafts, tunnels, and plenums; and exterior nonconcealed locations according to the following: 1. Near each valve and control device. 2. Near each branch connection, excluding short takeoffs for fixtures and terminal units. Mark each pipe at branch, where flow pattern is not obvious. 3. Near penetrations through walls, floors, ceilings, or nonaccessible enclosures. 4. At each pipe passage to underground. 5. At access doors, manholes, and similar access points that permit view of concealed piping. 6. Near major equipment items and other points of origination and termination. 7. Spaced at a maximum of 50-foot intervals along each run. Reduce intervals to 25 feet in areas of congested piping and equipment. 8. On piping above removable acoustical ceilings. 3.2 VALVE TAGS A. Install on valves and control devices in piping systems, except check valves, valves within factory-fabricated equipment units, plumbing fixture supply stops, shutoff valves, faucets, convenience and lawn-watering hose connections, and HVAC terminal devices and similar roughing-in connections of end-use fixtures and units. List tagged valves in valve schedule. B. Install mounted valve diagrams and charts in each major equipment room. C. Provide second diagram and chart laminated between 15 mil plastic sheets. Two (2) holes to be furnished at top, with each hole reinforced. 3.3 EQUIPMENT SIGNS AND MARKERS A. Install engraved plastic-laminate signs or equipment markers on or near each major item of mechanical equipment. Include signs for the following general categories of equipment: 1. Main control and operating valves, including safety devices and hazardous units such as gas outlets. Page 5 of 6

2. Fire department hose valves and hose stations. 3. Meters, gages, thermometers, and similar units. 4. Fuel-burning units, including boilers, furnaces, heaters, stills, and absorption units. 5. Pumps, compressors, chillers, condensers, and similar motor-driven units. 6. Heat exchangers, coils, evaporators, cooling towers, heat recovery units, and similar equipment. 7. Fans, blowers, primary balancing dampers, and mixing boxes. 8. Packaged HVAC central-station and zone-type units. 9. Tanks and pressure vessels. 10. Strainers, filters, humidifiers, water-treatment systems, and similar equipment. B. Optional Sign Types: Stenciled signs may be provided instead of engraved plastic, at Installer's option, where lettering larger than 1-inch high is needed for proper identification because of distance from normal location of required identification. 1. Lettering Size: Minimum 1/4 inch for name of units if viewing distance is less than 24 inches, 1/2 inch for viewing distances up to 72 inches and proportionately larger lettering for greater viewing distances. Include secondary lettering two-thirds to three-fourths the size of principal lettering. 2. Terms on Signs: Distinguish between multiple units, indicate operational requirements, indicate safety and emergency precautions, warn of hazards and improper operations, and identify units. C. Plasticized Tags: Install within concealed space, to reduce amount of text in exposed sign outside concealment, if equipment to be identified is concealed above acoustical ceiling or similar concealment. 1. Identify operational valves and similar minor equipment items located in unoccupied spaces, including machine rooms, by installing plasticized tags. D. Duct Systems: Identify air supply, return, exhaust, intake, and relief ducts with duct markers; or provide stenciled signs and arrows showing service and direction of flow. 1. Location: Locate signs near points where ducts enter into concealed spaces and at maximum intervals of 50 feet in each space where ducts are exposed or concealed by removable ceiling system. 3.4 ADJUSTING AND CLEANING A. Relocate mechanical identification materials and devices that have become visually blocked by work of this or other Divisions. B. Clean faces of identification devices and glass frames of valve charts. END OF SECTION Page 6 of 6