TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

Similar documents
TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

SPECIFICATION. Optical Fiber Cable

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

Outdoor, CCTV or CCTV, Fig 8 Armored.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Outdoor, Fig 8 Armored, Multi Tube

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Standard Monotube SAFE

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Ø 1250 * 688 mm 93 kg ± 105m

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Ø560*336mm 4.25 kg 2100 ± 105m

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Optical Systems Contents

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Type QG-G50-2C- M-BU

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Fiber Optic Outside Plant Cables (4-144 Fibers)

features and benefits

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Electric cables. Cranes

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Optical Ground Wires (OPGW)

Datasheet Outside Plant Cable

OFS AllWave non-dispersion shifted single-mode optical fiber

ZHONGTIAN TECHNOLOGIES CO., LTD

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Integrating Global Communications...

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

Nufern 980 nm Select Cut-Off Single-Mode Fiber

ZHONGTIAN TECHNOLOGIES CO., LTD

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

u n a B Optical Cables UNIFLEX CABLES LTD.

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Cable Type 100. CAI Certification Specification

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

Cable Type 125. CAI Certification Specification

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

ABOUT US ABOUT US 1 CRANE CABLES

Fibre Optic Indoor/Outdoor Cable

CommunicationCables FIBER OPTICS OPGW FTTH

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Single-Armored Cables, Fibers

Industrial Automation

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

For Public Comment DRAFT MALAYSIAN STANDARD STAGE : PUBLIC COMMENT (40.20) DATE : 01/10/ /11/2015

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

REPORT OF PERFORMANCE TIC

PERFORMANCE SPECIFICATION SHEET

Technical Specification. for 1.1 KV Copper Control Cable

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

kv: medium voltage reeling cable with fibreoptics

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

ITU-T G.654. Characteristics of a cut-off shifted single-mode optical fibre and cable

DRAFT MALAYSIAN STANDARD. Telecommunication cable: Single-mode optical fibre cable - Loose tube type for aerial installation

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

FTTH Fiber Optical Cable

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT

DESIGNING AND DEPLOYING SPECIAL MULTI FUNCTION FIBER OPTIC CABLES

IBER OPTIC ATTENUATOR (FC/UPC, SC/UPC,

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

ITU-T G.656. Characteristics of a fibre and cable with non-zero dispersion for wideband optical transport

HERMETICALLY SEALABLE PATCHCORDS WITH METAL SOLDER

Welding Cables Rubber Insulated

Outside Plant All Dielectric

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

COPPER + LWL RAW CABLES

Y O U R W A Y ENGINEERING PRODUCTS. adritec.com

Information technology. Generic cabling systems, General requirements

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

FiberHome Fiber Products

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

This special provision is for the installation and testing of the following equipment:

Transcription:

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application (SM 12 Fibers) Product: Single Mode Optical Fiber Cable Customer: Date: Write by: Kevin Zhou / technical engineer International Business Dept. TONGDING GROUP JIANGSU TONGDING OPTIC-ELECTRONIC STOCK CO., LTD. Add: No.18 Xiaoping Rd., Badu Industrial Zone, Wujiang City, Jiangsu Province China 215233 Tel: 0086-512-63873510, Fax: 0086-512-63873512 Webpage: http://www.tdgd.com.cn, E-mail: tongdingchina@yahoo.cn Page 1 of 6

1. Cable Construction 1.1 Cable cross-section Loose tube Optical fiber Filling gel Filling compound Steel wire Filler rod Inner sheath Filling compound Steel tape Outer sheath 2. Cable Specification 2.1 Sheath marking TDGD TDGD 2010 GYTY53 12B1.3 (G.652.D) =XXXXm : Manufacturer s brand 2010 : Manufacture year GYTY53 : Cable type 12B1.3 (G.652.D) : 12 cores single-mode optical fiber (ITU-T Rec. G.652.D) =XXXXm *The marking is printed every 1 meter; : Mark of meters ** G.652D means ITU-T Rec. Low Water Peak (LWP) G.652 single mode optical fiber. 2.2 The color of marking is white, but if the remarking is necessary, the yellow color marking shall be printed newly on a different position. 2.3 An occasional unclear of length marking is permitted if both of the neighboring markings are clear; 2.4 The both cable ends are sealed with heat shrinkable end caps to prevent water ingress. Page 2 of 6

2.5 Fiber color code No 1 2 3 4 5 6 Color Blue Orange Green Brown Slate White No 7 8 9 10 11 12 Color Red Black Yellow Violet Pink Aqua 2.6 Color codes for Loose Tube (LT) & Filler Rod (FR) Fiber Element no. number 1 2 3 4 5 6 12 LT LT FR FR FR FR 2.7 Cable structure and parameter Fiber number Max. fiber number per tube Total unit number (LT + FR) I / O sheath thickness (nominal*) Overall diameter (nominal**) Weight (approx.) mm mm kg/km 12 6 6 (2LT + 4FR) 1.0 / 1.8 12.7 170 * The nominal sheath thickness may vary by 0.2mm. ** The nominal outer diameter and height may vary by 0.2mm. Page 3 of 6

3. Fiber Properties 3.1 The properties of single mode optical fiber (ITU-T Rec. G.652.D) Item Specification Fiber type Fiber material Attenuation coefficient @ 1310 nm @ 1383 nm @ 1550 nm @ 1625 nm Point discontinuity Cable cut-off wavelength Zero-dispersion wavelength Zero-dispersion slope Single mode Doped silica 0.36 db/km 0.32 db/km 0.22 db/km 0.30 db/km 0.05 db 1260 nm 1300 ~ 1324 nm 0.093 ps/(nm 2.km) Chromatic dispersion @ 1288 ~ 1339 nm 3.5 ps/(nm. km) @ 1271 ~ 1360 nm 5.3 ps/(nm. km) @ 1550 nm 18 ps/(nm. km) @ 1625 nm 22 ps/(nm. km) PMD Q (Quadrature average*) 0.2 ps/km 1/2 Mode field diameter @ 1310 nm Core / Clad concentricity error Cladding diameter Cladding non-circularity Primary coating diameter 9.2±0.4 um 0.5 um 125.0 0.7 um 1.0% 245 10 um Proof test level 100 kpsi (=0.69 Gpa), 1% Temperature dependence 0 o C~ +70 o C @ 1310 & 1550nm 0.1 db/km * PMD Q is a link of 20 cable sections (M) and a probability level of 0.01% (Q). 4. Characteristic of Optical Cable 4.1 Mechanical & environmental characteristics 4.1.1 Cable bending radius: 10 x cable diameter (during operation) 4.1.2 Temperature range Operating temperature range Storage / Transport temperature range Installation temperature range 20 x cable diameter (during installation) -40 o C to +60 o C -50 o C to +70 o C -20 o C to +50 o C Page 4 of 6

4.2 Main mechanical & environmental characteristics test NO ITEM TEST METHOD ACCEPTANCE REQUIREMENTS 1 Tensile Strength IEC 794-1-E1 - Load: 3, 000 N - Length of cable under load: 50m 2 Crush Test IEC 60794-1-E3 3 Impact Test IEC 60794-1-E4 - Load: 3, 000 N/100mm - Load time: 1min - Points of impact: 5 - Times of per point: 5 - Impact energy: 10.0Nm - Radius of hammer head: 12.5mm - Impact rate: 2sec/cycle 4 Repeated Bending IEC 60794-1-E6 - Bending Dia.: 20 x OD - Load: 250N - Flexing rate: 3sec/cycle - No. of cycle: 30 5 Torsion IEC 60794-1-E7 - Length: 1m - Load: 250N - Twist rate: 1min/cycle - Twist angle: ±90 - No. of cycle: 10 6 Water Penetration IEC 60794-1-F5B - Height of water: 1m - Sample length: 3 m - Time: 24 hour - No water shall have leaked from the opposite end of cable 7 Temperature Cycling IEC 60794-1-F1 - Temperature step: +20 o C -40 o C +60 o C +20 o C - Time per each step: 24 hrs - Number of cycle: 2 8 Compound Flow IEC 60794-1-E14 - Sample length: 30 cm - Temp: 70 C 2 C - Time: 24 hours - No compound flow 9 Sheath High Voltage Test - On line test - 9t KV (t-sheath thickness) - No sheath breakdown Page 5 of 6

5. Packing and Marking 5.1 Packing 5.1.1 Each single length of cable shall be reeled on Fumigated Wooden Drum suitable for long distance shipment. 5.1.2 Covered by plastic buffer sheet. 5.1.3 Sealed by strong wooden battens. 5.1.4 At least 1 m of inside end of cable will be reserved for testing. 5.1.5 Drum length 5.1.5.1 Standard drum length is 2000m±3%; 5.1.5.2 Single length not less than 95% of standard length per drum shall be permitted for quantity not exceeding 10% of the total supply; 5.1.5.3 Total quantity is at least the ordered quantity. 5.2. Drum Marking 5.2.1 Cable drum - Manufacturer brand; - Roll-direction arrow; - Cable outer end position indicating arrow; - The word OPTICAL FIBER CABLE ; - Origin, The word MADE IN CHINA ; - Caution plate indicating the correct method for loading, unloading and convey the cable; - Other customer information such as contract no., project no., and delivery destination. (if needed) 5.2.2 Marking plate - Product name; - Cable type and size; - Drum length; - Gross / Net weight in kilograms; - Drum number in meters; - Manufacturer's name; - Manufacturing year and month; - Project number, contract number or purchasing order number (if needed). 5.3 Cable identification documents - Test report. -----------End---------- Page 6 of 6