OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

Similar documents
Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Outdoor, CCTV or CCTV, Fig 8 Armored.

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

RECOMMENDATION ITU-R BT.1367 *

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

CONTENTS. Introduction Characteristics Product range Pages

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

Outdoor, Fig 8 Armored, Multi Tube

Industrial Automation

Lectureo5 FIBRE OPTICS. Unit-03

is a method of transmitting information from one place to another by sending light through an optical fiber. The light forms an electromagnetic

R2CT Outdoor Interconnection System

Type QG-G50-2C- M-BU

Fiber Optic Principles. Oct-09 1

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

FIBER OPTIC CABLE ASSEMBLIES

Fiber Optic Communication Systems. Unit-05: Types of Fibers.

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Light Guide Overview

Multi-gigabit intra-satellite interconnects employing multi-core fibers and optical engines

Optical fibres. Outer protective

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

2. The Basic principle of optical fibre (Or) Working principle of optical fibre (or) Total internal reflection

FIBER OPTICS. Dr D. Arun Kumar Assistant Professor Department of Physical Sciences Bannari Amman Institute of Technology Sathyamangalam

Books: 1. Data communications by William L Schweber 2. Data communication and Networking by Behrouz A F0rouzan

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

Class 4 ((Communication and Computer Networks))

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

TECHNICAL ARTICLE: DESIGN BRIEF FOR INDUSTRIAL FIBRE OPTICAL NETWORKS

Fiber Optic Communications Communication Systems

features and benefits

COM 46: ADVANCED COMMUNICATIONS jfm 07 FIBER OPTICS

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

This special provision is for the installation and testing of the following equipment:

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

CAT 5e UTP Cable: NETSET BOX [305m], indoor

Optical Fiber. n 2. n 1. θ 2. θ 1. Critical Angle According to Snell s Law

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

4-Channel Optical Parallel Transceiver. Using 3-D Polymer Waveguide

Migration to 50/125 µm in the Local Area Network

Standard Monotube SAFE

Core Polymethyl Methacrylate (PMMA )

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Introduction to Fiber Optics

COPPER + LWL RAW CABLES

Application Note 5596

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Laboratory of Optoelectornics

P802.3cd Clause 138 hazard level recommendations. P802.3cd Interim meeting, May 2017 Richard Johnson and Jonathan King, Finisar

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Analog OptoLock FC300T

Exp. No. 13 Measuring the runtime of light in the fiber

A presentation of Pirmin Vogel, Benjamin Weber and Marco Karch 2008 by P.V.B.M.M.K. Ltd. & Co KG (release date , ver. 1.

Ø560*336mm 4.25 kg 2100 ± 105m

SUBMERSIBLE PUMP CABLES

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

HIGH BIT RATE OPTICAL FIBRE NETWORKS - optical fibre selection and implementation

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

SISNet Distance Extenders

Ø 1250 * 688 mm 93 kg ± 105m

Absorption: in an OF, the loss of Optical power, resulting from conversion of that power into heat.

Copper and Fiber Optic Cables

Computer Networks Lecture -4- Transmission Media. Dr. Methaq Talib

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Z EE E E Z E Z Z Z Z Z

Why Using Fiber for transmission

Optical Fiber Technology. Photonic Network By Dr. M H Zaidi

u n a B Optical Cables UNIFLEX CABLES LTD.

Chapter 2: Computer Networks

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

FIBER CABLE ASSEMBLIES Termini, Cable, and Connectors

Attenuation and Time Dispersion Measurements of Graded Index Polymer Optical Fiber for. Indoor Cellular Coverage

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

kv: medium voltage reeling cable with fibreoptics

Optical Systems Contents

This Special Provision covers the requirements for the installation and testing of fibre optic modems (FOM).

RF Connectors Technical Data Sheet. Gold over Nickel Plated Beryllium Copper Contact. Size in [11.81 mm] . Weight lbs [3.18 g].

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

7/16 DIN Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

Single-Armored Cables, Fibers

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Cable Attachment Method (Shield/Contact) Size Length, in [mm] 0.98 [24.89] Width/Dia., in [mm] [9.53]. Weight, lbs [g] 0.02 [9.07] 3.

Transcription:

IEEE 1394b Series Dongle OptoLup TM OptoLup TM Data Sheet Ver. 1.0 Overview COMOSS OptoLup TM Cable is a type of APF, All Plastic-fiber; both the core and the cladding are made of plastic, among of which the refractive index of the core is higher than the cladding, so that when an optical ray is transmitted at an angle into the cable, the optical ray can be reflected back at the boundary between the core and the cladding for the transmitting. This is International standard IEC60794-2-40 compliant s. 1 Web: http://www.comoss.com/

Content CONTENT... 2 FEATURES... 3 GENERAL SPECIFICATIONS (S.I. POF)... 4 APPLICATION... 5 STRUCTURAL DRAWING OF REFRACTIVE INDEX... 6 ORDER INFORMATION... 7 2

Features (1) Low cost, low attenuation and high band width. (2) Better installed bend radius than GOF, bending failures can be solved. (3) Designed to be used with plugless connection technology. (4) With the specialty for use with COMOSS former designed POF cutter. (5) With matured process, the concentricity between fiber core and cladding are well controlled. (6) Not only suitable for Toslink, Mini-Plug, SMI and IDB1394, OptoLup TM can be used with FC/SC/ST & LC connectors as well. (7) Both Simplex and Duplex are available, with Comoss designed field installation tool kit, technical people are easily to be trained for fast installation. (8) Targeted applications : Industrial, Multimedia, Interconnection, LAN, and Surveillance. (9) Compliant to IEC60794-2-40. (JIS C 6836). 3

General Specifications (S.I. POF) Fiber Type Products number -S51D1W -S51S1W -S51D2B -S51S2B Core PMMA PMMA PMMA PMMA Cladding Fiber Diameter 1000+/-60uM 1000+/-60uM 1000+/-60uM 1000+/-60uM Attenuation at 650nm 0.2dB/m 0.2dB/m 0.2dB/m 0.2dB/m Refractive Index Core 1.492 1.492 1.492 1.492 Cladding 1.405 1.405 1.405 1.405 Acceptance Angle, 60 60 60 60 Outer Sheath Mat l PE PE PE PE Sheath color White White Black Black Numerical Aperture 0.5 0.5 0.5 0.5 Minimum Bend Radius 15mm 15mm 25mm 25mm Conductors Duplex Simplex Duplex Simplex Outer Diameter, mm 1.5mm*3.0mm 1.5mm 2.2mm*4.4mm 2.2mm Standard length, KM 2.0 2.0 2.0 2.0 Cable weight, KG/km 5 2.5 8.5 4.5 Storage, operating temperature -40~+75-40~+75-40~+75-40~+75 Note: relative specifications (1) IEC 60793-1-1 : Optical fibres Part 1-1 : Measurement methods and test procedures General guidance. (2) IEC60794-1-2 : Optical fibre cables Part 1-2 : Generic specification Basic optical cable test procedures. (3) IEC60793-1-20 : Optical fibres Part 1-20 : Measurement methods and test procedures Fibre geometry. (4) IEC60793-1-40 : Optical fibres Part 1-40 : Measurement methods and test procedures Attenuation. (5) IEC60793-2-40 : Optical fibres Part 2-40 : Product specifications Sectional specification for category A4 multimode fibres. (6) IEC 60794-2-40 : Optical fibre cables Part 2-40 : Indoor optical fibre cables Family specification for A4 fibre cables. 4

Application 5

Structural drawing of refractive index 6

Order Information - S 5 1 D 2 B (1) (2) (3) (4) (5) (6) (1) Index type : S: Step Index. (S.I.) G: Graded Index. (G.I.) (6) Jacket Color Option: B: Black color W: White color (2) Numerical Aperture (N.A.): 2: N.A. 0.2 3: N.A. 0.3 (5) Jacket O.D.: 1: O.D. 1.5mm 2: O.D. 2.2mm 5: N.A. 0.5 (3) Core size: 1: 980micron/core, 1000micron cladding 2: 120micron/core, 490micron cladding (4) Conductors: D: Duplex. (Zip cord type) S: Simplex P.S. OptoLup TM is registered by COMOSS Electronic Co., Ltd. 7