Installation and Operation Manual Document Number 000-specc

Similar documents
JAZ-ALP Adjustable Laser Pointer Operation Manual Document Number 013-RD

RaySphere Solar Analysis System (RaySphere and RaySphere 1700) Installation and Operation Manual Document Number RAYSPHERE

IDRaman micro Installation and Operation Manual

Installation and User Guide. FlexIR TM NIR Fiber Optic Accessory

Miniature Spectrometer Technical specifications

SPM-50 RF Spectrum Power Meter PC Software User Manual

SPECTRONIC Standards User Guide

How-to guide. Working with a pre-assembled THz system

EDUCATION EXPERIMENT. Determining Color Difference (Delta E) Introduction

Using the Integrating Sphere in the Multiple Application Platform (MAP)

OVA-50 Optical Variable Attenuator User s Manual

ACA-4HSRPP-2458 Data Sheet

Model BiConiLog Antenna. User Manual

SWS SWS62221 Spectral Sensor. General Description. Block Diagram

Microscope-Spectrometer

sig pro TM LASER (SPP) Handling & Safety Instructions

OP735. Benchtop Optical Power Meter Instruction Manual

Model 3110B Biconical Antenna

specification display & lighting hera spectrometer

CFC Series Cable Replacement Kit. for CFP Series Carbon Fiber Boom Poles. Owner s Manual

User s Manual. English SUN-HMS200/400. Fiber Microscope. Table: SUN-UM-TL-HMS001 Version: A/0

OP710. Multichannel Optical Power Meter Instruction Manual. (Also supports the OP710-ANX)

SCREENING EFFICIENCY TESTER Model 271

NANOSECOND PULSE GENERATOR NPG-15/2000(N) USER MANUAL

Flat Sample Holder Part Number

Pulsed Laser Power Measurement Systems

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

SMALL GAUGE NIBBLER ASSEMBLY & OPERATING INSTRUCTIONS Mission Oaks Blvd., Camarillo, CA Visit our Web Site at

Z-5652 plus Series. 2D Image Hands-Free Scanner

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

External Optical Probes. EOP-xxx and ISP 40. Two Global Leaders. One Complete Solution.

Advanced Test Equipment Rentals ATEC (2832)

UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Industrial Automation

ACC-6SMRP2U Data Sheet

Installing the detector filter assembly (G )

InsuLogix T Portable One Channel Temperature Measurement System Manual

Model 3180B Mini-Bicon Antenna User Manual

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

MANUAL MOUNTING SYSTEM FOR CORRUGATED ROOF

FSCTD Dual Back to Back Flat Screen Ceiling Mount

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Lab Junior Educational UV-VIS Spectrometer

HEIGHT ADJUSTABLE WORKBENCH

All Purpose Hardware

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Owner s Manual & Safety Instructions

Double-Ridged Waveguide Horn Antennas

AvaLight-DHc Full-range Compact Light Source

Model 3116 Double-Ridged Waveguide Horn

JETI Specbos Instruments

INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

MW-C WALL MOUNT ADAPTER. For MD-ASL15W and MD-BSL15W Monitor Mounts. User Manual

ROLLER STAND WITH TWO-LEG SUPPORT ASSEMBLY AND OPERATING INSTRUCTIONS

Quick Release Hardware

SlimScan BT Users Manual

Section IX: AF Series Fibers and Fiber Couplers

Light Guide Overview

Multi-function bar clamp

Wenger Corporation 2010 Printed in China 02/10 Part #148H Wenger Corporation, 555 Park Drive, P.O. Box 448, Owatonna, Minnesota

Diode Pointer Quick Start Guide

LC200WT Security Wall Mount with Tilt for up to 32" Flat Screens

18 PIECE HOLE SAW SET

OxFAC-08 Angled Fiber Cleaver. User Manual. Issue 1.5

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

15-GHz & 25-GHz Photodetectors Models 1480-S & 1481-S

Radio System Strobe Wizard Plus Freemask

LED Lighting Flux and Color Measurement System (LFC)

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL

ENGLISH Spider Stage 1 x 1 m / 2 x 1 m

LC6X4WTM Security Wall Mount with Tilt for up to 60" Flat Screens with VESA 600mm x 400mm or less

Elcometer 141. Paint Inspection Gauge. Operating Instructions

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

Photosynthetically Active Radiation (PAR) Smart Sensor (Part # S-LIA-M003)

Folding Beauty Dish. Guide

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS

Coating Thickness Measurement System

DEP 001. Operation Manual

Variable Anamorphic Prism Pair. Manual

Supplementary Materials

APPLICATION NOTE. Computer Controlled Variable Attenuator for Tunable Lasers. Technology and Applications Center Newport Corporation

We bring quality to light. MAS 40 Mini-Array Spectrometer

Laser Light Barrier. Operating Manual. Electronic pdf files of Nordson EFD manuals are also available at nordsonefd.com

Angle Grinder. Model Visit our website at:

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Microscope Boom Clamp Stand

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

INSTALLATION & ADJUSTMENT INSTRUCTIONS FOR LETHAL WEAPON MODEL 150 & MODEL 200 SIGHTS AND ACCESSORIES

Table 8 Overview light sources

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

DC to 3.5-GHz Amplified Photoreceivers Models 1591 & 1592

Improving the Collection Efficiency of Raman Scattering

Mobile Cart for Flat Panel Display (PTC-2000 Series)

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

Radiant Pro 2500 Video Light (Cat. No. 6047)

Transcription:

SpectroClip Probe SpectroClip-R/SpectroClip-TR/Jaz-SpectroClip-TR Installation and Operation Manual Document Number 000-specc-110-02-201203 Offices: Ocean Optics, Inc. World Headquarters 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 Fax 727.733.3962 8 a.m. 8 p.m. (Mon-Thu), 8 a.m. 6 p.m. (Fri) EST E-mail: Info@OceanOptics.com (General sales inquiries) Orders@OceanOptics.com (Questions about orders) TechSupport@OceanOptics.com (Technical support) WARNING Protective Eye Wear Must Be Worn When Using This Instrument - Intense Ultraviolet Radiation Present See Important Safety Notices inside. 000-00000-000-02-A

Additional Offices: Ocean Optics Asia 666 Gubei Road, Kirin Tower, Suite 601B, Changning District, Shanghai, PRC. 200336 Phone 86.21.5206.8686 Fax 86.21.5206.8686 E-Mail Sun.Ling@OceanOptics.com Ocean Optics EMEA Sales and Support Center Geograaf 24, 6921 EW DUIVEN, The Netherlands Phone 31-26-3190500 Fax 31-26-3190505 E-Mail Info@OceanOptics.eu Copyright 2012 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Ocean Optics, Inc. This manual is sold as part of an order and subject to the condition that it shall not, by way of trade or otherwise, be lent, re-sold, hired out or otherwise circulated without the prior consent of Ocean Optics, Inc. in any form of binding or cover other than that in which it is published. Trademarks Microsoft, Windows, Windows 95, Windows 98, Windows Me, Windows NT, Windows 2000, Windows XP and Excel are either registered trademarks or trademarks of Microsoft Corporation. Limit of Liability Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an as is basis. Ocean Optics, Inc. shall have neither liability nor responsibility to any person or entity with respect to any loss or damages arising from the information contained in this manual.

Important Safety Notices 1. Read this manual before you attempt to use this instrument. 2. Do not remove or modify any installed safety device on this equipment. Doing so will void your warranty and create an unsafe operating environment. 3. Only allow qualified personnel to service this unit. 4. Before using the optical tool for the first time check for transport damage. Do not use the unit if it is damaged in any way. Contact your dealer for repair or replacement information. 000-specc-110-02-201203 A

Important Safety Notices B 000-specc-110-02-201203

Table of Contents About This Manual... iii Document Purpose and Intended Audience... iii Document Summary... iii Product-Related Documentation... iii Upgrades... iii Chapter 1: Setup and Operation...1 Overview... 1 SpectroClip Models... 2 Unpacking SpectroClip... 2 Package Contents... 3 SpectroClip Parts... 3 Using SpectroClip... 4 Using SpectroClip-R... 4 Using SpectroClip-TR... 4 Transmission Measurement Loss of Intensity... 5 Adjustment of the 8 Coupling Port... 5 Chapter 2: SpectroClip Specifications...7 Index...9 000-specc-110-02-201203 i

Table of Contents ii 000-specc-110-02-201203

About This Manual Document Purpose and Intended Audience This document provides you with an installation section to get your light source up and running. Document Summary Chapter Chapter 1: Setup and Operation Chapter 2: SpectroClip Specifications Description Provides a list of package contents and unpacking instructions. Also contains a list of parts and operating instructions. Contains product specifications. Product-Related Documentation You can access documentation for Ocean Optics products by visiting our website at http://www.oceanoptics.com. Select Technical Operating Instructions, then choose the appropriate document from the available drop-down lists. Or, use the Search by Model Number field at the bottom of the web page. You can also access operating instructions for Ocean Optics products on the Software and Technical Resources CD included with the system. Engineering-level documentation is located on our website at Technical Engineering Docs. Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number. Please contact an Ocean Optics Application Scientist for specific instructions when returning a product. 000-specc-110-02-201203 iii

About This Manual iv 000-specc-110-02-201203

Chapter 1 Setup and Operation Overview The SpectroClip probe is designed to measure thin materials such as leaves and other thin samples in the field. Transmission, reflection and absorbance can be measured on materials with a maximum thickness of 5 mm. SpectroClip features specially designed integrating spheres that function as collection probes and can be connected to any Ocean Optics spectrometer to acquire data. The top integrating sphere also includes an input port for a fiber-coupled light source to illuminate your sample. SpectroClip's integrating spheres capture diffuse reflected or transmitted light more efficiently than lens-based collection optics. Jaz-SpectroClip-TR SpectroClip can support wavelength ranges from 200-2500 nm -- depending on which light source, fiber (UV-VIS or VIS-NIR) or spectrometer configuration you use. The active illuminated area is 5 mm. 000-specc-110-02-201203 1

1: Setup and Operation SpectroClip Models SpectroClip includes the following models: Model Purpose Included Equipment Other Recommended Equipment* SpectroClip-R Collects reflected light from the sample One integrating sphere Spectrometer, one light source, two fibers SpectroClip-TR Collects both transmitted and reflected light from the sample Two integrating spheres Two spectrometers (or one 2-channel Jaz), one light source, three fibers Jaz-SpectroClip-TR Performs transmission and reflectance characterization of (thin) samples in the field Two integrating spheres; a Jaz spectrometer (400 1000 nm) with two spectrometer channels, a tungsten-halogen light source module, and a battery module; 3 fibers, and the Spectro-Clip-TR probe N/A * Fibers are sold separately. The recommend fiber core is 600 µm or larger because of the attenuation of the sphere. Unpacking SpectroClip The following sections provide instructions on unpacking and setting up your SpectroClip. Before using the SpectroClip for the first time, check for transport damage. Be sure to adhere to all warnings on the unit and in this manual. Procedure 1. Unpack your SpectroClip device carefully. 2. Inspect the outside of the instrument and make sure that there is no damage. Do not use the instrument if damage is present. 3. Detach the outer side of the fiber protection and inspect the SMA connectors. Do not use the instrument if damage is present. 2 000-specc-110-02-201203

Package Contents 1: Setup and Operation Your SpectroClip package should contain the following: SpectroClip device (plus Jaz spectrometer for Jaz-SpectroClip-TR) Black and white reference device Spiral coiled tube 1.5 meters long (for fiber protection) Hexagonal socket screw keys SW 2.5 mm and SW 1.3 mm SpectroClip Parts For optimal optical measurements, take care that no objects or liquids enter into the integrating spheres. To do this, use protection caps on open SMA connectors, and keep the gripper closed while not using the SpectroClip. In addition, keep the reference clean and undamaged for best reference measurements. 000-specc-110-02-201203 3

1: Setup and Operation Using SpectroClip The procedure for using your SpectroClip differs, depending on which model you have. Using SpectroClip-R Procedure 1. Unscrew one part of the fiber cover. 2. Slip the spiral coiled tubes over the fibers. 3. Connect the two fibers to the SMA connectors. You shouldn t use a fiber thicker than 400 µm on the focusable SMA connector from the picture above. 4. Assemble the fiber cover and tighten the three screws. The spiral coiled tube should begin inside the fiber cover. 5. To record a dark spectrum use the black/ white reference with the black side turned to the reflectance sphere. 6. To record a reference spectrum use the black/ white reference with the white side turned to the reflectance sphere. 7. Clamp your measuring object into your SpectroClip and start the measurement. Caution For mechanical reasons, you can use samples with a height of up to 15 mm only. Avoid stray light. During your measurement there should be no light bypassing your sample. Using SpectroClip-TR 1. Unscrew one part of the fiber cover. 2. Slip the spiral coiled tubes over the fibers. 3. Connect three fibers to the SMA connectors. If you don t use all SMA connectors cover the empty connector with a protection cap. 4 000-specc-110-02-201203

1: Setup and Operation 4. Assemble the fiber cover and tighten the three screws. The spiral coiled tube should begin inside the fiber cover. 5. To record a dark spectrum, use the black/ white reference with the black side turned to the reflectance sphere. 6. To record a reference spectrum use your SpectroClip without any object between the clamps. 7. Clamp your measuring object into your SpectroClip and start the measurement. Caution Don t use samples thicker than 5 mm. With thicker samples, the amount of unwanted stray light increases. Transmission Measurement Loss of Intensity It is recommended to use the same distance between integrating spheres to measure the reference spectra as was used for the sample measurement. The loss of intensity for a port difference of 1 mm is 3 % @620 nm with respect to zero difference. Other losses of intensity for the reference spectra are shown in the table below. Fiber and Diameter Distances (Valid for Optical Alignment) Fiber Diameter (µm) Maximum Port Difference Loss in Reference Spectrum (relative to 0 distance) 100 8 10% 400 4 10% Adjustment of the 8 Coupling Port You can adjust the focus of the light beam between the upper fiber and the opening of the reflectance sphere. Procedure To adjust the focus, 1. Loosen the screw on the SMA connector (#7 in SpectroClip Parts) with the hexagon socket screw key (SW 1.3 mm). 2. Move the SMA connector for optical performance. 3. Block the screw after adjustment. 000-specc-110-02-201203 5

1: Setup and Operation 6 000-specc-110-02-201203

Chapter 2 SpectroClip Specifications Specification Size (without fibers)(lxhxw) Weight (without fibers) Wavelength Range (Spectrometer) Value 22 cm x 12 cm x 17 cm 500 g Spectralon 000-specc-110-02-201203 7

2: SpectroClip Specifications 8 000-specc-110-02-201203

Index A adjusting the coupling port, 5 C coupling port adjustment, 5 document audience, iii purpose, iii summary, iii D J Jaz-SpectroClip-TR, 2 M models, 2 operation, 1 O P package contents, 3 parts, 3 product-related documentation, iii S safety notices, A setup, 1 specifications, 7 SpectroClip-R, 2 using, 4 SpectroClip-TR using, 4 Spectro-Clip-TR, 2 Transmission loss of intensity, 5 unpacking, 2 upgrades, iii T U 000-specc-110-02-201203 9

Index 10 000-specc-110-02-201203