Electrical Controls. Isaac Queen

Similar documents
ELECTRICAL INDUSTRIAL INSTALLATIONS

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

ECET 211 Electrical Machines and Controls

Chapter 5 Electric Logic Sensors and Actuators

ECET 211 Electric Machines & Controls Lecture 4-2 Motor Control Devices: Lecture 4 Motor Control Devices

WESTERN IOWA TECH COMMUNITY COLLEGE. Course Syllabus. Electrical Technician Level 2

Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition)

Lessons In Industrial Instrumentation

Construction Electrician/Industrial Electrician/Power Electrician Common Core Level 2

CIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 92 Series and 93 Series

ECET 211 Electric Machines & Controls Lecture 7 Relays. Lecture 7 Relays

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

Primary Resistor Starters with Time Relays

Draw the symbol and state the applications of : 1) Push button switch 2) 3) Solenoid valve 4) Limit switch ( 1m each) Ans: 1) Push Button

AC Magnetic Starters (GE)

COURSE SYLLABUS. COURSE NUMBER AND TITLE: INTC-1357 AC/DC Motor Controls (2-4-3)

ECET 211 Electric Machines & Controls Lecture 7 Relays (1 of 2) Lecture 7 Relays

Take for instance this circuit:

Power systems Protection course

Mechatronics Electricity Advanced Mechatronics System (AMS) Courseware Sample

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems

ADVANCED PLC PROGRAMMING. Q. Explain the ONE SHOT (ONS) function with an application.

Monostable multivibrators

Join Us In Industrial Automation Group For Training & Consulting.


WHEN A PLC IS TOO MUCH, AND SPACE FOR

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate.

SUBELEMENT T6 Electrical components: semiconductors; circuit diagrams; component functions 4 Exam Questions - 4 Groups

Technician Licensing Class T6

Unit 2 Electrical Circuit Diagrams

Industrial Electrician Level 3

Construction Electrician Level 2

ELECTRICAL MAINTENANCE SKILLS

Creating Electrical Designs

T6A4. Electrical components; fixed and variable resistors, capacitors, and inductors; fuses, switches, batteries

Switches Unlimited Contact: Phone: Fax:

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Output of three-phase motors at 50 Hz and 400 V

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Experienced Worker Assessment Blueprint Industrial Electronics

Wisconsin Technical College System Curriculum Standards Model & Program Design Summary ELECTRICAL & INSTRUMENTATION APPRENTICE

Power Electrician Level 3

Massachusetts Amusement Device Safety Seminar 2015

Proximity sensors. Inductive. Connection. magnetic. Festo Didactic Training and Consulting Sensors

Interfacing of Proximity Sensor with My-RIO Toolkit Using LabVIEW R. Aasin Rukshna 1 S.Anusha 2 E.Bhuvaneswarri 3 T.Devashena 4

Introduction to PLC and Ladder Logic Programming

PLC BASED RAILWAY LEVEL CROSSING GATE CONTROL

Electromechanical Technology /Electromechanical Engineering Technology CIP Task Grid

Properties of Inductor and Applications

Energizing a world that demands more

Introduction to PLCs

Contents. Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T40-187

Electronic Systems - B1 23/04/ /04/ SisElnB DDC. Chapter 2

ELECTRONIC SYSTEMS. Introduction. B1 - Sensors and actuators. Introduction

Relay Types and Applications Dr. Sasidharan Sreedharan

Sensors. Chapter 3. Storey: Electrical & Electronic Systems Pearson Education Limited 2004 OHT 3.1

SKILLS DEVELOPMENT FACILITY PRE-QUALIFIED SUPPLIERS OF EQUIPMENT/TOOL-2017

Sensor boxes series SB

Job Sheet 2 Servo Control

in one housing (3). The light beam is reflected by a reflector (4). The objects are detected by interruption of the light beam.

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

CONTROL SYSTEM COMPONENTS

Technical Information General Purpose Relays

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

For Immediate Delivery call KMParts.com at (866)

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Implementation Of Solid State Relays For Power System Protection

FC Series Signal Conditioners

PARKER HANNIFIN TEST STAND

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

Introduction. A closed loop of wire is not an electrical circuit, a circuit requires

Industrial Maintenance Mechanics

Analog Inputs and Outputs

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors


g GE POWER MANAGEMENT

NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x G TIMER OUTPUTS INTRODUCTION SPECIFICATIONS AUXILIARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

NEMA Size 1 Cat. No. CN55DN3AB

GRAAD 12 NATIONAL SENIOR CERTIFICATE GRADE 12

Process & Instrumentation Diagram * (P&ID) Tutorial

Know about. Different Types of Relays

Power connections, minimum and maximum wiring capabilities, tightening torque

Auto Diagnosis Test #2 Review

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Mechatronics Chapter Sensors 9-1

Sensors. CS Embedded Systems p. 1/1

Interfacing Industrial Analog Sensors to the Internet of Things Darold Wobschall Esensors Inc.

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x A INTRODUCTION TIMER OUTPUTS SPECIFICATIONS AUXILARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

pi2ig-l 1988 STANDARD for GRAPHIC ELECTRICAL/ 00 ELECTRONIC AIR-CONDITIONING AND REFRIGERATING EQUIPMENT SYMBOLS FOR AIR-CONDITIONING

Experiment (1) Principles of Switching

BASIC ELECTRICAL AND INSTRUMENTATION DESIGN TRAINING SECTOR / ENGINEERING

The Global Expert in Solid State Switching Technology

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Application Alley. Automated Test Equipment - Reed Relays. Pulsed High Current Testing Applications use Reed Relays PARTNER SOLVE DELIVER

Crane Boss TITAN 500

Defining Sinking & Sourcing I/O

LV Compensation & Filtering Products

Transcription:

Electrical Controls Isaac Queen iqueen@atn.org www.atn.org 1

Contact blocks include normally open (NO), normally closed (NC), or both NO and NC contacts. 2

A joystick is used to control many different circuit operations from one location. 3

Limit switches are used to convert a mechanical motion into an electrical signal. 4

An actuator is the part of a limit switch that transfers the mechanical force of the moving part to the electrical contacts. 5

A foot switch is used to allow hands-free control or an additional control point. 6

Direct scan is a method of scanning in which the target is detected as it passes between the transmitter and receiver. 7

Retroreflective scan is a method of scanning in which the target is detected as it passes between the photoelectric sensor and reflector. 8

Diffuse scan is a method of scanning in which the target is detected when some of the emitted, reflected light is received. 9

Ultrasonic sensors detect objects by bouncing highfrequency sound waves off the object. 10

A reed relay is a fast-operating, single-pole, singlethrow switch that is activated by a magnetic field. 11

Inductive proximity sensors use a magnetic field to detect the presence of a target. 12

Capacitive proximity sensors use a capacitive field to detect the presence of a target. 13

Capacitive sensors work based on the dielectric of the material to be sensed. 14

A Hall generator is a thin strip of semiconductor material through which a constant control current is passed. 15

Hall effect sensors are available in a variety of packages for different applications. 16

A line (ladder) diagram consists of a series of symbols interconnected by lines that are laid out like rungs on a ladder to indicate the flow of current through the various components of a circuit. 17

A solenoid is an electric output device that converts electrical energy into a linear mechanical force. 18

A contactor is a control device that uses a small control current to energize or de-energize the load connected to it. 19

The electrical operation of a contactor can be shown using a line diagram, a pictorial drawing, and/or a wiring diagram. 20

Auxiliary contacts may be added to a contactor to form an electrical holding circuit. 21

A magnetic motor starter is an electrically operated switch (contactor) that includes motor overload protection. 22

The electrical operation of a motor starter can be shown using a line diagram, a pictorial drawing, and/or a wiring diagram. 23

The three stages a motor goes through during normal operation include resting, starting, and operating under load.

An overload relay does not open a circuit while a motor is starting, but opens the circuit if the motor gets overloaded and the fuses do not blow.

In three-wire control, three wires lead from the control device to the starter or contactor.

A step-down control transformer is used to step down the voltage to the level required in the control circuit.

Contactors have either an AC coil or a DC coil, but may have either AC or DC contacts.

A magnetic motor starter is a contactor with overload protection added.

An electronic overload has built-in circuitry that senses changes in current and temperature.

Auxiliary contacts are added to give circuits with pushbuttons memory.

Two stop pushbuttons connected in series and two start pushbuttons connected in parallel are used to control a motor from two locations.

Two start/stop stations are used to control two separate magnetic motor starter coils with a common emergency stop protecting the entire system.

Two motors can be started almost simultaneously from one location to prevent product separation or stretching.

A pilot light is used with a pressure switch to indicate when a device is activated.

A pilot light is used with a start/stop station to indicate when a device is activated.

NOT logic is used to indicate when a device is not operating.

A sequence control circuit does not let the first conveyor operate unless the second conveyor has started and is running.

A selector switch is used to provide a common industrial jog/run circuit.

40

A magnetic reversing starter may be controlled by forward and reverse pushbuttons. 41

42

43

44

45

A PLC simplifies the wiring of inputs and outputs by eliminating the need for auxiliary contacts on the starter. 46

Programmable logic relays are versatile and are normally used for control circuits that require numerous relays and/or frequent changes. 47

48

49