IMPORTANT: If installing a Glide Bifold Door only; ie. a recess installation, please refer to alternative fixing details on the document reverse.

Similar documents
Bi-fold Door Installation Instructions

Slider Door Installation Instructions

Bath Screen. IN00351(rev C)

IN00571 (Iss 2) L Shaped Bath Screen. Instruction suitable for both Right and Left Hand Fixing.

Half framed 2-Panel Bath Screen

Modular Shower Panel. IN00580 (Iss 1)

INSTALLATION INSTRUCTION New Luxury Slider Door 8mm

Centre-fold Door. Installation Instructions. Please note: Images shown are for illustration purposes only

Step-by-Step Installation Instructions for

Step-by-Step Installation Instructions for

CORNER ENTRY ENCLOSURE

Step-by-Step Installation Instructions for

Gallium 03 Installation Instructions & Parts List

INSTALLATION INSTRUCTIONS

Step-by-Step Installation Instructions for

Hinge Door + Side Panel

INFINITE RANGE - HINGE DOOR

INFINITE RANGE - CENTRE FOLDING DOOR

Curium 19.4H Installation Instructions & Parts List

Curium 19H Installation Instructions & Parts List

Argon 02 Installation Instructions & Parts List

INSTALLATION INSTRUCTIONS

Hinge Door + One Inline Panel

Xenon 05 Installation Instructions & Parts List

INFINITE RANGE - CENTRE FOLDING DOOR

Dubnium 11 Installation Instructions & Parts List

Wall Profiles 2 Pozi Screwdriver. Wall Profile Covers 4 Sealant. Large Panel and Thin Panel Assemblies Sealant Gun

Cleaning. This instruction will cover installation of the following units Codes:

Radon 07 Installation Instructions & Parts List

SLIDING DOOR for CORNER installation ONLY - this door closes to side panel -

Hinge Door + Inline Panel + Return Panel

Installation Instructions

SHOWERLUX HELPLINE: TEL: SHOWERLUX (UK) Ltd.

B A T H R O O M G L A S S

DESIGN TRIPLE PANE BATH SCREEN

LUXURY CURVED QUADRANT SINGLE DOOR

UNIT No FRAMELESS PIVOT SHOWER DOOR

Installation Site Preparation - Site Preparation

PREMIER PENTAGON SHOWER ENCLOSURE

Sliding Door Enclosure. Telephone Cleaning. Please retain this manual after installation for future reference and maintenance.

IMPORTANT - GLASS IS FRAGILE AND CAN SHATTER.

DESIGN QUADRANT SINGLE DOOR


Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

Frameless Fixed Panel Slider

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

Assembly Instructions Pivot Door

Installation Instructions. Walk-in Shower Screen. with 180 Return Panel

Sliding Door Enclosure

935 RODA VINESSE NEED INSTALLATION HELP? DOUBLE ROLLERS FRAMELESS DOOR INSTALLATION INSTRUCTIONS QCI XX/XX/XXXX. Call BASCO ( )

Frameless Fixed Panel Slider QCI5279

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Frameless Bypass Slider

*** All chrome surfaces should be cleaned using a clean damp cloth. *** No abrasive cleaning agents or materials should be used.

Solutions. Installation Instructions. Ref Description Illustration Qty. A Shower Tray* mm Radius Curved Panel* Universal. Curved Quad Panel*

Shower Screen and Door Kit Instructions

Installation Instructions

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE

IMPORTANT INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

COMPONENTS AND BOX CONTENTS

Please read these instructions throughout before installing as incorrect fitting will invalidate the guarantee.

INSTALLATION INSTRUCTIONS 960 RODA GLASS TO GLASS HINGES ANGLED FRAMELESS PANEL / DOOR / PANEL CELESTA DRESDEN TRESOR

Frameless Inline Door With Return QCI5263

Installation Instructions

Frameless Bypass Slider

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

Frameless Hinged Door Enclosure. These instructions must be left with the user. Installation Guide W2-B

PRISM LUX / PYRAMID SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE

Frameless Inline Door QCI5248

PRIME SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Monaco Installation Guide - Surface Profiles

INSTALLATION INSTRUCTIONS 935 RODA GLASS TO GLASS HINGES FRAMELESS DOOR / PANEL CELESTA DRESDEN GEOLUX TRESOR VONSE

INSTRUCTION FOR WALL-FIXING OF VANITY UNIT GAYA

QUADRANT SHOWER ENCLOSURE

Installation Instructions

Portofino Installation Guide

mistley PELE Installation Guide vapr16 Mistley Bathroom Glass Limited No 4 One Mistley Quayside, High Street, Mistley, Essex CO11 1AL England

Frameless Inline Door With Return QCI5128

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

FLEX 48 x 72 / 60 x 72

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

INSTALLATION INSTRUCTIONS

Deauville Installation Guide

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE 1400A-1700A-1800A

Frameless Inline Door QCI5288

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.

SHOWER DOORS INSTALLATION INSTRUCTIONS SHOWER DOORS: LBSDD Version 4.0

Installation Guide. Frameless Sliding Door - Alcove. These instructions must be left with the user

VITREO X SHOWER / TUB DOOR INSTALLATION INSTRUCTIONS

QWALL 5.2 (2 Back Panels)

Double Door Quadrant Enclosure (V2 ~ Semi frameless). Installation / Maintenance Instructions rev Lakes. Bathrooms

UNIDOOR LUX (STYLE E)

Model 5400H / 7000H Illustrated Installation Instructions

COMPONENTS AND BOX CONTENTS

Panel Riser Kit Option 1. Installation Instructions 226BEE 0117CH

Frameless Inline Door QCI5254

SHOWER ENCLOSURES INSTALLATION INSTRUCTIONS SHOWER ENCLOSURES:

300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT

Transcription:

IN00422 (rev A) Aqua 6 / Aqua 8 Glide Bifold Door & Side Panel Instruction suitable for both Right and Left Hand fixing variations. IMPORTANT: If installing a Glide Bifold Door only; ie. a recess installation, please refer to alternative fixing details on the document reverse.

Before You Start Check that the tray has been installed correctly and that it is level (Fig. A), tiled down onto and sealed to the manufacturer s guidelines. Please Note: All product supplied without tray. Ensure the product is fitted to a non-porous surface ie. tiled. Check that the wall surface is flat. Unpack and check the product is complete and undamaged. Fixings are supplied for solid walls only. Ensure that the correct fixings are used for the wall type if in doubt seek professional advice. Ensure the area is clean, dry and dust free. Read the instructions in full. Have the correct tools available, (as shown below, see Tools Required ). It is recommended to situate the showerhead and door adjacent to each other in order to allow any water spray to be on the side panel or upstanding wall. Safety Handle all glass with care - support on cardboard to avoid risk of breakage. This product is heavy and requires 2 people to carry and install it. When drilling walls check first for hidden pipes and cables. All glass is toughened it cannot be reworked or replaced by ordinary glass. Use safety eyewear when drilling. Use safety eyewear when handling glass. Keep all small parts away from children. Disclaimer Please notify the retailer immediately of any damage or faults. The manufacturer cannot be held responsible for any installation costs that may arise from damaged or faulty product being installed. Please dispose of all packaging with due regard to the environment. Tools Required (not supplied) Fig.A. Spirit Level Screwdriver Tape Measure Pencil Utility Knife Junior Hacksaw Silicone Gun & Sealant Power Drill Suitable Drill Bits 6mm dia. * 3mm dia. HSS * Ensure drill bit used is suitable for wall surface Help Line: 0870 241 6131 Lines open: 8.30am - 5.00pm Monday to Friday Standard National call charge rate from BT landlines

Parts & Fittings Supplied Please notify the retailer immediately of any damage or faults. The manufacturer cannot be held responsible for any installation costs that may arise from a damaged or faulty product being installed. Keep small parts away from children D2 Side Panel X1 Glide Bifold Door* X1 D1 D3 D4 Allen Keys Supplied 3mm Allen Key *Please Note: Glide Bifold Door Aqua 6 and Aqua 8 Hinge Variants, please refer to Fig. B for details.

Fig. B: Glide Bifold Door hinge details* *Aqua 8 Variant: D1 D2 **Left and right hand variants supplied Wall Channel Top Cap** X2 **Left and right hand variants supplied Corner Post Top Cap** X1 Wall Channel X2 Corner Post Trim X1 Stile Cap X3 A Wall Channel Trim X2 B C C

D3 D4 Towel Rail Assembly*** X1 Door Knob Assembly X1 ***Aqua 8 Variant: Loose Screws & Fittings Supplied Qty A No.8 x 1¾ Pan Head Pozi Screws (actual size) x8 Qty B Wall Plugs (actual size) x8 Qty C No.8 x ⅜ Pan Head Pozi Screws (actual size) x12

Before you start - IMPORTANT NOTE: Right hand Entry Rail Cut-out at the TOP of door Glide Bifold Door is supplied preassembled for Right hand entry. If you are happy with the Standard Right Hand entry as shown please begin your installation at step 1.1. If in doubt please seek advice. Right Hand Entry Before you start - IMPORTANT NOTE: Left hand Entry Rail Cut-out at the TOP of door Glide Bifold Door is supplied preassembled for Right hand entry. However if you would prefer your installation to have a left hand entry please follow the alternative door entry steps i-viii. If in doubt please seek advice. Left Hand Entry

Left hand entry only: i Door in to open position. Left hand entry only: ii Using Allen Key supplied, loosen set screw as shown.

Left hand entry only: iii Remove Head Fixing Block Assembly as shown Move door into central location bringing the left hand carriage in line with the head rail access point. Left hand entry only: iv Remove retainer screw.

Left hand entry only: v Re-position Head Fixing Block Assembly as shown Move Door back slightly so that bringing the right hand fixing carriage is with level head access point. Left hand entry only: vi Reinsert retainer screw on opposite side.

Left hand entry only: vii Left hand entry only: viii If required, use Allen Key supplied to loosen set screw before locating door block on retaining screw. Using Allen Key supplied, tighten set screw as shown.

1.1 1.2 1.3 Mark position of Wall Channels Ensure glass is positioned straight and is parallel with tray.

Wall plugs supplied are for solid walls only. Ensure correct wall plug for wall type is used. If in doubt seek professional advice. 2.1 2 Position Wall Channel on wall as shown, ensure Wall Channel is fixed level. Mark position of pre-drilled Wall Channel fixing hole 2.2 6mm dia. holes with drill bit suitable for wall surface 2.3 A B Fix through pre-drilled Wall Channel fixing hole * Tip: When drilling tiles apply masking tape to surface to stop drill bit slipping. Plan View 3 Ensure glass is positioned straight and is parallel with tray.

* 3mm dia. holes through pre-drilled holes using HSS drill bit 4 4.1* 4.2 C * Tip: When inserting screws apply a small amount of oil to the screw thread to allow easier fixing. Ensure that the door frame stile verticals are perfectly vertical for a smooth opening of the door. 5 *3mm dia. holes through pre-drilled holes using HSS drill bit 5.1* 5.2 C Ensure that the door frame stile verticals are perfectly vertical for a smooth opening of the door. * Tip: When inserting screws apply a small amount of oil to the screw thread to allow easier fixing.

6 Please Note: Towel Rail is supplied assembled. Using Allen key supplied, disassemble part and then re-assemble as shown. Ensure all screw heads are on the enclosure interior. DO NOT overtighten. Aqua 8 Variant: Please Note: Towel Rail is supplied assembled. Using Allen key supplied, disassemble part and then reassemble as shown. Ensure all screw heads are on the enclosure interior. DO NOT overtighten.

7 Please Note: Door Knob is supplied assembled. By hand, disassemble part and then re-assemble as shown. DO NOT overtighten. 8 8.1 Push fit Corner Post Trim 8.2 Push fit Wall Channel Trim

9 * * Push fit Wall Channel End Cap and Stile End Cap into position. For best results, locate Stile Caps at the back edge first in the U feature. Take care not to let Wall Channel End Caps or Stile End Caps slip down the Wall Channel. 10 Apply Silicone Sealant, (not supplied) horizontally between glass and tray only. Apply Silicone Sealant, (not supplied) vertically between wall channel and wall only.

Apply Silicone Sealant, 11 (not supplied). 150mm 150mm 150mm * Product Care: Use a non-abrasive cleaner. Water marks may be removed with a proprietary limescale remover or household vinegar.

IN00422 (rev A) Aqua 6 / Aqua 8 Glide Bifold Door Recess Fit Instruction suitable for both Right and Left Hand fixing variations. IMPORTANT: If installing a Glide Bifold Door and Side Panel; ie. a corner installation, please refer to alternative fixing details on the document reverse.

Before You Start Check that the tray has been installed correctly and that it is level (Fig. A), tiled down onto and sealed to the manufacturer s guidelines. Please Note: All product supplied without tray. Ensure the product is fitted to a non-porous surface ie. tiled. Check that the wall surface is flat. Unpack and check the product is complete and undamaged. Fixings are supplied for solid walls only. Ensure that the correct fixings are used for the wall type if in doubt seek professional advice. Ensure the area is clean, dry and dust free. Read the instructions in full. Have the correct tools available, (as shown below, see Tools Required ). It is recommended to situate the showerhead and door adjacent to each other in order to allow any water spray to be on the side panel or upstanding wall. Safety Handle all glass with care - support on cardboard to avoid risk of breakage. This product is heavy and requires 2 people to carry and install it. When drilling walls check first for hidden pipes and cables. All glass is toughened it cannot be reworked or replaced by ordinary glass. Use safety eyewear when drilling. Use safety eyewear when handling glass. Keep all small parts away from children. Disclaimer Please notify the retailer immediately of any damage or faults. The manufacturer cannot be held responsible for any installation costs that may arise from damaged or faulty product being installed. Please dispose of all packaging with due regard to the environment. Tools Required (not supplied) Fig.A. Spirit Level Screwdriver Tape Measure Pencil Utility Knife Junior Hacksaw Silicone Gun & Sealant Power Drill Suitable Drill Bits 6mm dia. * 3mm dia. HSS * Ensure drill bit used is suitable for wall surface Help Line: 0870 241 6131 Lines open: 8.30am - 5.00pm Monday to Friday Standard National call charge rate from BT landlines

Parts & Fittings Supplied Please notify the retailer immediately of any damage or faults. The manufacturer cannot be held responsible for any installation costs that may arise from a damaged or faulty product being installed. Keep small parts away from children D1 Glide Bifold Door* X1 D2 Allen Keys Supplied 3mm Allen Key *Please Note: Glide Bifold Door Aqua 6 and Aqua 8 Hinge Variants, please refer to Fig. B for details.

Fig. B: Glide Bifold Door hinge details* *Aqua 8 Variant: D1 D2 **Left and right hand variants supplied Wall Channel X2 Wall Channel Trim X2 B Wall Channel Top Cap** X2 Stile Cap X2 Door Knob Assembly X1 A C

Loose Screws & Fittings Supplied Qty A No.8 x 1¾ Pan Head Pozi Screws (actual size) x8 Qty B Wall Plugs (actual size) x8 Qty C No.8 x ⅜ Pan Head Pozi Screws (actual size) x8 Before you start - IMPORTANT NOTE: Right hand Entry Before you start - IMPORTANT NOTE: Left hand Entry Rail Cut-out at the TOP of door Rail Cut-out at the TOP of door Right Hand Entry Left Hand Entry Glide Bifold Door is supplied preassembled for Right hand entry. If you are happy with the Standard Right Hand entry as shown please begin your installation at step 1.1. If in doubt please seek advice. Glide Bifold Door is supplied preassembled for Right hand entry. However if you would prefer your installation to have a left hand entry please follow the alternative door entry steps i-viii. If in doubt please seek advice.

Left hand entry only: i Door in to open position. Left hand entry only: ii Using Allen Key supplied, loosen set screw as shown.

Left hand entry only: iii Remove Head Fixing Block Assembly as shown Move door into central location bringing the left hand carriage in line with the head rail access point. Left hand entry only: iv Remove retainer screw.

Left hand entry only: v Re-position Head Fixing Block Assembly as shown Move Door back slightly so that bringing the right hand fixing carriage is with level head access point. Left hand entry only: vi Reinsert retainer screw on opposite side.

Left hand entry only: vii Left hand entry only: viii If required, use Allen Key supplied to loosen set screw before locating door block on retaining screw. Using Allen Key supplied, tighten set screw as shown.

1.1 Please Note: Position one wall channel and mark. Ensure Wall Channel is level and in correct location to the tray. (If in doubt refer to illustration on step 2). 1.2 1.3

Plan View 2 Ensure glass is positioned straight and is parallel with tray. IMPORTANT: Ensure Door is not twisted. For best results fix one side wall channel, and check door is level before continuing to fix second wall channel. 3.1 Mark position of pre-drilled Wall Channel fixing hole 3 3.2 6mm dia. holes with drill bit suitable for wall surface 3.3 B Fix through pre-drilled Wall Channel fixing hole Position Wall Channel on wall as shown, ensure Wall Channel is fixed level. A

4 *3mm dia. holes through pre-drilled holes using HSS drill bit 4.1* 4.2 C Ensure that the door frame stile verticals are perfectly vertical for a smooth opening of the door. * Tip: When inserting screws apply a small amount of oil to the screw thread to allow easier fixing. 5 Please Note: Door Knob is supplied assembled. By hand, disassemble part and then re-assemble as shown. DO NOT overtighten.

6 Push fit Wall Channel Trim 7 * * Push fit Wall Channel End Cap and Stile End Cap into position. For best results, locate Stile Caps at the back edge first in the U feature. Take care not to let Wall Channel End Caps or Stile End Caps slip down the Wall Channel.

8 Apply Silicone Sealant, (not supplied) vertically between wall channel and wall only. 9 Apply Silicone Sealant, (not supplied). 150mm * Product Care: Use a non-abrasive cleaner. Water marks may be removed with a proprietary limescale remover or household vinegar.

Notes: Notes: