COUPLING DECOUPLING NETWORK MODEL CDN-AF4

Similar documents
Log Periodic Antenna

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

MODEL 3810/2 Line Impedance Stabilization Network

Bulk Current Injection Probe Test Procedure

Coupling/Decoupling Networks (CDN)

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Current Probe Fixture Instruction Manual

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Broadband Current Probe Series Operation Manual

Broadband Current Probe Series Operation Manual

Model 1791 VHF Radio User's Manual

ELECTROSURGICAL UNIT ANALYZER

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Coupling / decoupling network (CDN) for screened or coaxial cables

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Instruction Manual Model Upconverter

Coupling/Decoupling Networks (CDN)

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

SAS-563B Active Loop Antenna Operation Manual

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Model 7000 Low Noise Differential Preamplifier

POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2. 5 khz 1 GHz

Instruction Manual Model M Switch, DPDT, Manual Select

SAS-551 Passive Monopole Antenna Operation Manual

INTRODUCTION The B-24-G is a VHF band high power linear amplifier designed for the 144 MHz band. It has a maximum output power of 50W.

Instruction Manual Model Upconverter

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SAS-562B Active Loop Antenna Operation Manual

INSTRUCTION MANUAL LKG

Advanced Test Equipment Rentals ATEC (2832)

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Broadband Power Amplifier

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Current Probes. User Manual

411LA Broadband Power Amplifier

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

COM-POWER OPERATION MANUAL ACS W

Emerging Standards for EMC Emissions & Immunity

Advanced Test Equipment Rentals ATEC (2832)

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

MODEL W Power Amplifier

CBA 400M MHZ to 400 MHZ

200Amp AC Clamp Meter + NCV Model MA250

Amplifier Series BASIC. Installation & Operations Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

PI-10 Broadband Power Indicator

DL102 Counter Loop Amplifier

User Guide. Digital AC/DC Clamp Meter Model 38394

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

User s Guide. Digital AC/DC Clamp Meter Model 38394

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

MICRO SERIES MONITORS

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

TDS-535 Tuned Dipole Set Operation Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Mirage B-320-G FEATURES

TA MHz oscilloscope probe TA MHz oscilloscope probe

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

SAS-543 Biconical Antenna Operation Manual

Opus 21 s80 Integrated Amplifier Owner's Manual

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

A 500 Broadband Power Amplifier

Model 4007DDS. 7 MHz Sweep Function Generator

MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AMP-13 OPERATOR S MANUAL

MONITORING DEVICE 4 khz to 400 MHz

MODEL FS-4 INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A.

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

2100L Broadband Power Amplifier

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

DM-45 Digital Multimeter

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

True RMS AC / DC Power Clamp Meter Model

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

SPM-50 RF Spectrum Power Meter PC Software User Manual

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Copyright 2014 by Minarik Drives

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Operator s Manual. PP016 Passive Probe

Instruction Manual. KP-1 Series 10M, 6M, 2M, 1-1/4M, 70 CM. IN-SHACK GaAsFET PRE-AMPLIFIER. MIRAGE KP-1 Pre-Amplifier

PI-150 Broadband Power Indicator

AMM-1022 Digital Multimeter USER`S MANUAL

A Channel Amplifier

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Transcription:

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

II Warranty Com-Power warrants to its Customers that the products it manufactures will be free from defects in materials and workmanship for a period of 2 years. This warranty shall not apply to: a) transport damages during shipment from your plant. b) damages due to poor packaging. c) product operated outside their specification. d) improperly maintained or modified. e) consumable items, fuses, power cords, cables, etc. f) normal wear g) calibration h) product is shipped outside the United States without the prior knowlege of Com-Power. In addition, Com-Power shall not be obliged to provide service under this warranty to repair damage resulting from attempts to install, repair, service or modify the instrument by personnel other than Com-Power service representative. Under no circumstances does Com-Power recognize or assume liability for any loss, damage or expense arising, either directly or indirectly from the use or handling of this product, or any inability to use this product seperately or in combination with other equipment. When requesting warranty services, it is recommended that the original packaging material be used for shipping. Damage due to improper packaging will void warranty. In the case of a complaint, a label should be attached to the housing of the instrument which describes briefly the faults observed. If at the same time the name and telephone number (dialing code and telephone or direct number or department designation) is stated for possible queries, this helps towards speeding up the processing of waranty claims. In order to obtain service under this warranty, Customers must contact the Com-Power factory.

Safety Precautions III This instrument has left the factory in a safe condition. Proper safety precautions must be observed in order to avoid injury to test personnel. Prior to the connection of RF power, the CDN must be securely fastened to the ground plane. Proper grounding ensures the low impedance required for accurate immunity measurements. Proper grounding must be verified after installation. The resistance between the CDN grounding base plate and the ground plane should indicate a value of 10 milli-ohms or less. Power conductors to the mains should not be connected until all the connections to the EUT, CDN, auxilary equipement and test equipment are completed. Test personnel should not touch any exposed test leads or terminals during the test. After each test disconnect power conductors from the mains and turn off power to the amplifier. About this this manual This manual provides instructions on how to operate and maintain Model CDN-AF4 coupling decoupling network. Information contained in this manual is property of Com-Power Corporation. It is issued with understanding that none of this material may be reproduced of copied without permission from Com-Power. If you need assistance: Telephone: (949) 587-9800 Fax: (949) 587-9960 Email: Sales@Com-Power.com

IV Operating Enviroment Maintenance The instrument has been designed for indoor use only. It should not be used in damp or wet enviorment. The permissible ambient temperature range during operation is +10 C (+50 F) to +40 C (+104 F). Please read the safety section. There are no user serviceable parts inside these units. If the unit does not operate or needs calibration, please return it to the factory. Do not open instrument cover. Any modifications or repairs performed on the unit by someone other than a auhorized factory trained technician will void warranty. The exterior surface may be cleaned with mild detergent and then be wiped with a dry clean lint-free cloth. Do let any cleaning agent seep into into the chassis.

V Content Section Page 1 General Information... 1-1 1.0 Introduction... 1-1 1.1 General Description... 1-1 1.2 Specifcations... 1-1 1.3 Standard Accessories Supplied... 1-1 2 CDN Requirement... 2-1 2.0 Overview... 2-1 2.1 CDN Requirement... 2-1 2.2 Important CDN parameters... 2-3 3.0 Calibration... 2-3 4.0 Establishing drive table... 2-4 4.1 Setting levels... 2-5 3 Theory of Operation... 3-1 3.0 Overview... 3-1 3.1 Typical test setup... 3-1 List of Figures Figures... page 1-1 CDN-AF4 Photo... 1-2 1-2 Typical terminal impedance... 1-3 1-3 Typical coupling factor... 1-4 1-4 Typical attenuation factor... 1-5 3-1 Conducted immunity setup... 3-1 List of Tables Tables... page 1-1 CDN-AF4 specifications... 1-2 2-1 CDN parameters... 2-1 2-2 Required test levels... 2-5

General Information This section includes the following Introduction General Description Specifications Standard Accessories Supplied 1 1-1 1.0 Introduction This section contains general description and performance information on the Com-Power model CDN-AF4 Coupling Decoupling Network (CDN). More detailed explanation on how to use CDN is given in sections 2 and 3 of this manual. 1.1 General Description The Com-Power CDN-AF4 Coupling / Decoupling networks (CDN) is intended for testing products according to EN61000-4-6 standard for immunity to conducted disturbance induced by radio frequency fields from 150 khz - 80 MHz. The CDN-AF4 couples common mode CW and modulated signals on to a unshielded 4 conductor cable. 1.2 Specifications Please see table 1-2 on page on next page. 1.3 Standard Accessories Supplied; 1. Coupling Decoupling Network 2. User's Guide 3. Calibration data- Impedance, attenuation,coupling factor 4. Certificate of calibration Options if ordered: Jig with shorting bars, Two 150Ω - 50Ω, One 50 Ω adapter, one Ground plane (Complete kit Part# CK-

1-2 Table 1-1 Specifications Frequency Range: 150 khz - 80 MHz Cable type: Unshielded 4 conductor cable Coupling: Each Conductor Voltage: 160 VAC Current: 2 Amps Common mode impedance: 150 khz - 26 MHz: 150 Ohms ± 20% 26 MHz - 80 MHz: 150 Ohms + 60% and - 45.5% Maximum RF voltage input: 40 V max Voltage attenuation (RF/EUT): 9 db to db Insertion loss EUT/AE: 30 db min from 150 khz to 2 MHz 50 db min from 2 MHz to 80 MHz Coupling factor: 0. db, + 1 db / - 2 db Decoupling attenuation (RF/AE): 50 db min, 150 khz - 80 MHz I/O connections: Proffessional Audio Sockets Note: The shield is not connected to ground. RF (Disturbance coupling) connector: BNC (f) 50 Ohm Dimensions ( L x W X H): x 6 x 6" inches Weight : 4 lb. Figure 1-1 Model CDN-AF4

1-3 Figure 1-2 CDN Model CDN-AF4 typical common mode impedance

1-4 Figure 1-3 CDN Model CDN-AF4 typical attenuation factor graph

1-5 Figure 1-4 CDN Model CDN-AF4 typical Coupling factor graph

2-1 CDN Requirements This section includes the following Overview CDN requirements Calibration 2 2.0 Overview Com-Power CDN-AF4 allows coupling of RF CW and modulated voltages into equipment throught the shield of four conductor signal cables. This CDN was built to meet the requirments of IEC-1000-4-6. This CDN-AF4 can be used to verify that electronic equipment are not susceptible to sources electromagnetic disturbance which may couple to shield of signal cables. 2.1 CDN requirements The CDN-AF4 coupling and decoupling network: Allows Coupling of the disturbing signals to the equipment under test. Provides stable impedance to the equipment under test independent of the auxillary equipment common mode impedance. Prevents interference to the auxillary equipment by decoupling the disturbing signals. Does not interrupted signals to the EUT The Com-Power CDN-AF4 meet the following parameters specified by IEC-1000-4-6 specifications. Table 2-1 Coupling Decoupling Device Parameters

The IEC-1000-4-6 recommends putting coupling decoupling networks on signal cables between the EUT and Auxillary equipment. Generally the stop frequency range for IEC-1000-4-6 requirement is 80 MHz. Some product specific standards may require extending the stop frequency to 230 MHz when the dimensions of device under test may be be less than λ /4. The Com-Power CDNs can be used to meet this extended frequency requirement. 2.2 Important CDN parameters The most important characteristic when selecting CDN is to insure that it meets the Common mode terminal impedance specified in the IEC-1000-4-6. It would be also benificial to select CDN with low attenuation and coupling factors. Please see section 1 for typical measured values for these parameters for Com-Power CDN-AF4 Common mode impedance parameters at the EUT port of the CDN are given in table 2-1. This ensures that any circuit level abnormal operation was caused by the injected RF signal on the EUT and not the auxillary equipment (AE). The requirement must be met with CDN auxillary input terminals open or short circuited to ground. 2.2.2 Voltage attenuation Attenuation is the amount of power that is lost between the signal input terminal of the CDN and the EUT port. The IEC- 1000-4-6 specification does not specify the attenuation factor, however it benificial to keep it low as possible. The attenuation factor for the Com-Power CDN is approximately 10 db for the frequency range of 150 khz - 80 MHz. The attenuation is useful factor for predicting the amount of input power required to generate required immunity voltage. 2.2.3 Coupling factor The CDN coupling factor is defined as the open circuit voltage obtained at the EUT (common mode) port devided by the open circuit voltage obtained at the input connector. The coupling factor value is not defined by IEC-1000-6 specification, but 2-2

should kept minimum. The Com-Power CDN coupling factor is almost 0 db for the entire frequency of 150 khz - 80 MHz. 3.0 Measuring these factors on site Typically, the common mode terminal impedence, attenuation and coupling factors are measured at the factory and supplied with each unit. However if you wish to check the attenuation and coupling factor on site you could purchase optional calibration kit which includes the shorting bars, set of 150Ω - 50Ω adapters and 50Ω adapter. You will aso need calibration the shorting bars for making level measurements described in section 4.0 (part# CK-CDNAF4RCA). The common mode impedance measurement is made using appropriate network analyzer. 2-3

4.0 Establishing a drive table 2-4 Before you begin you will need to test your setup to establish the correct immunity levels. The setup is similar to the attenuation measurment setup except connect the power amplifier to the CDN input (please see figure 2-5). The 1EC- 1000-4-6 call out testing to three different open circuit test levels. The table below shows unmodulated disturbing signal levels expressed in r.m.s. Table 2-2 Test Levels specified by IEC-1000-4-6 SIGNAL GENERATOR POWER AMPLIFIER POWER ATTENUATOR 6 db SPECTRUM ANALYZER DIRECTIONAL COUPLER POWER METER INPUT 150Ω - 50Ω EUT CDN AE 150Ω - 50Ω 50Ω Adapter Adapter Adapter 345678903456789034567890345678903456789034567890 Calibration Jig with shorting bars Figure 2-5 Level measurement setup using CDN

2-5 4.1 Setting Levels After you make all the connection shown in figure 2-5, you are now ready for level measurements. The open circuit voltage levels given in table 2-2 must be recalculated to to account for the 50 Ω impedance adapter and the spectrum analyzer in the test setup. They are given below: Level 1 0.167 RMS 150 khz - 80 MHz Level 2 0.5 RMS 150 khz - 80 MHz Level 3 1.67 RMS 150 khz - 80 MHz The above voltage levels were calculated by deviding the open circuit voltage specified in table 2-1 by a factor of 6. The factor of 6 established due to the following. When the 150 Ω impedance adapter is connected CDN EUT port, the voltage level at the output terminal of the 150 Ω adapter it will be to half the injected voltage level at the CDN input. When adapter output is connected to a 50Ω spectrum analyzer, the voltage measured will be one third of the that value. Next, turn on the power amplifier and signal generator and take the measurements from 150 khz - 80 MHz for each level with CW unmodulated. The rate of the sweep shall not exceed 1.5 x 10 3 decades/seconds. If the frequency is swept incrementally, the step size shall not exceed 1% start and thereafter 1% of preceding frequency value. Create a chart and record the frequency and input power needed at each frequency to achieve each of the three levels for the entire range. (This process can be automated with appropriate software, contact Com-Power for details.) The next step is to activate the 1 khz sine wave modulator on your signal generator set it to 80% modulation depth and repeat measurements described in the previous paragraph. 4.2 Expected amplifier power requirement The power requirement to generate the maximum level is not expected to be more than 10 Watts. This takes into account attenuation factor 9 - db of the CDN for entire frequency range and the loss of amplifier forward power due to 3:1 VSWR created by the CDN and the passive impedance adapter.

3-1 Theory of Operations This section includes the following Overview Typical Test Setup 3 3.0 Overview This describes the typical test setup for making measurements using the CDN. Please read safety precautions in this manual before proceeding. 3.1 Typical test setup The IEC-1000-4-6 requires that an appropriate coupling decoupling networks (CDN) with defined common mode impedance must be connected the various cables connected to the EUT. The AF series CDN are only appropriate for cables with multiple unshielded conductors. Other types CDN may be necessary to couple and decouple different types of cables that may connected to the EUT. Such as coax, shielded cables, and powerline. Please see connection diagram below for typical conducted immunity test setup using the AF series CDNs. DISTURBING VOLTAGE SOURCE FORWARD POWER PORT 50 Ohm TERMINATOR ON INPUT EUT POWER DIRECTIONAL COUPLER UNSHIELDED CABLE AE POWER METER TO CDN INPUT FROM MAINS CDN M ser. EUT 345 345 CDN AF ser. 345678903456789034567890345678903456789034567890 AE 3 Ground Plane 100 mm insulating support Figure 3-1 Conduted Immunity test setup using S series CDNs