Light Detectors (abbreviated version, sort of) Human Eye Phototubes PMTs CCD etc.

Similar documents
Charged-Coupled Devices

Digital Imaging Rochester Institute of Technology

Properties of a Detector

3/5/17. Detector Basics. Quantum Efficiency (QE) and Spectral Response. Quantum Efficiency (QE) and Spectral Response

The Design and Construction of an Inexpensive CCD Camera for Astronomical Imaging

IV DETECTORS. Daguerrotype of the Moon, John W. Draper. March 26, 1840 New York

INTRODUCTION TO CCD IMAGING

Infrared Detectors an overview

Components of Optical Instruments

CHARGE-COUPLED DEVICE (CCD)

Astro-photography. Daguerreotype: on a copper plate

Activity 1: Make a Digital Camera

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Introduction. Laser Diodes. Chapter 12 Laser Communications

CCD Characteristics Lab

Light gathering Power: Magnification with eyepiece:

Astronomical Cameras

Charged Coupled Device (CCD) S.Vidhya

CCDS. Lesson I. Wednesday, August 29, 12

Photons and solid state detection

Based on lectures by Bernhard Brandl

Introduction to CCD camera

Introduction. Cambridge University Press Handbook of CCD Astronomy: Second Edition Steve B. Howell Excerpt More information

Astronomical Detectors. Lecture 3 Astronomy & Astrophysics Fall 2011

Where detectors are used in science & technology

APPENDIX D: ANALYZING ASTRONOMICAL IMAGES WITH MAXIM DL

A new Photon Counting Detector: Intensified CMOS- APS

LE/ESSE Payload Design

A new Photon Counting Detector: Intensified CMOS- APS

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

The DSI for Autostar Suite

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Image and Multidimensional Signal Processing

AST 443 / PHY 517. Photon Detectors

Machine Vision: Image Formation

Submillimeter (continued)

Engineering Medical Optics BME136/251 Winter 2018

Dynamic Range. Can I look at bright and faint things at the same time?

Light Microscopy for Biomedical Research

Receiver Performance and Comparison of Incoherent (bolometer) and Coherent (receiver) detection

2013 LMIC Imaging Workshop. Sidney L. Shaw Technical Director. - Light and the Image - Detectors - Signal and Noise

light sensing & sensors Mo: Tu:04 light sensing & sensors 167+1

3/27/17. Detector Basics. Quantum Efficiency (QE) and Spectral Response. Quantum Efficiency (QE) and Spectral Response

Charge-Coupled Device (CCD) Detectors pixel silicon chip electronics cryogenics

What an Observational Astronomer needs to know!

RADIOGRAPHY TERMS TO KNOW SELF STUDY DENTALELLE TUTORING

CCD reductions techniques

The new CMOS Tracking Camera used at the Zimmerwald Observatory

Lecture 12 OPTICAL DETECTORS

Ground-based optical auroral measurements

Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters

Production of HPDs for the LHCb RICH Detectors

Welcome to: LMBR Imaging Workshop. Imaging Fundamentals Mike Meade, Photometrics

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Telescopes and their configurations. Quick review at the GO level

Photometry using CCDs

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

Observational Astronomy

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

Electron Multiplying Charge Coupled Devices. Craig Mackay, Institute of Astronomy, University of Cambridge.

Photometry of the variable stars using CCD detectors

The Charge-Coupled Device. Many overheads courtesy of Simon Tulloch

10/3/2012. Study Harder

VII. IR Arrays & Readout VIII.CCDs & Readout. This lecture course follows the textbook Detection of

Lecture 8 Optical Sensing. ECE 5900/6900 Fundamentals of Sensor Design

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

10/26/2015. Study Harder

Charge Coupled Devices. C. A. Griffith, Class Notes, PTYS 521, 2016 Not for distribution.

Digital camera. Sensor. Memory card. Circuit board

CPSC 4040/6040 Computer Graphics Images. Joshua Levine

Lecture 5. Telescopes (part II) and Detectors

TIRCAM2 (TIFR Near Infrared Imaging Camera - 3.6m Devasthal Optical Telescope (DOT)

Time Delay Integration (TDI), The Answer to Demands for Increasing Frame Rate/Sensitivity? Craige Palmer Assistant Sales Manager

The 0.84 m Telescope OAN/SPM - BC, Mexico

Data Acquisition System for the Angra Project

An Introduction to CCDs. The basic principles of CCD Imaging is explained.

How Does One Obtain Spectral/Imaging Information! "

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

Acquisition, Processing and Display

Scintillation Counters

Detectors that cover a dynamic range of more than 1 million in several dimensions

Colorado School of Mines. Computer Vision. Professor William Hoff Dept of Electrical Engineering &Computer Science.

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Three Ways to Detect Light. We now establish terminology for photon detectors:

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

SUPPLEMENTARY INFORMATION

Lecture 9. Lecture 9. t (min)

Three Ways to Detect Light. Following: Lord Rosse image of M33 vs. Hubble image demonstrate how critical detector technology is.

Photomultiplier Tube

Cooled cameras for scientific applications and astronomy. Ian Alderton Alrad Imaging division of Alrad Instruments Ltd

Performance of Image Intensifiers in Radiographic Systems

University Of Lübeck ISNM Presented by: Omar A. Hanoun

Last class. This class. CCDs Fancy CCDs. Camera specs scmos

Astronomy 341 Fall 2012 Observational Astronomy Haverford College. CCD Terminology

TDI Imaging: An Efficient AOI and AXI Tool

Chemistry Instrumental Analysis Lecture 7. Chem 4631

IT FR R TDI CCD Image Sensor

High Performance. Image Intensifiers

Transcription:

Light Detectors (abbreviated version, sort of) Human Eye Phototubes PMTs CCD etc.

Human Eye Rods: more sensitive no color highest density away from fovea Cones: less sensitive 3 color receptors highest density near fovea

Phototubes Example of an early phototube attached to a telescope

Photomultiplier Tubes (these 2 figures from Hamamatsu s web page at http://hamamatsu.magnet.fsu.edu/articles/photomultipliers.html ) Not used much in astronomy today, but common in Cherenkov detectors in particle physics

Microchannel Plates (like a 2-D array of PMTs)

Charge Coupled Devices - CCDs Front-lit CCD - gate blocks the light! Back-lit CCD (for more discussion of MCPs, CCD,s etc, see http://downloads.micron.ox.ac.uk/lectures/micron_course_2015/lecture_10_cameras.pdf )

???? Quantum Efficiency

Hubble Space Telescope Spatial resolution ~0.1 arcsec (50 micro-radians) (5 AU at a distance of 50 pc)

MAMA = Multi-Anode Microchannel Array UV-sensitive CCDS on Hubble use down-converting phosphors & back side reprocessing http://www.stsci.edu/stsci/meetings/space_detectors/clampin.htm

CCD UV Phosphors include coronene, liumogen, metachrome, etc. Cowens, Blouke, Fairchild, & Westphal, 1980, Applied Optics, 19, 3727 coronene - a polycyclic aromatic hydrocarbon (PAH) (highlighter pens use pyranine) (similar chemical technology is used in clothes brighteners and in bright printer paper)

In the upper figure, a positive voltage on one of the gates attracts and confines the electrons. By increasing the voltage in the next gate while reducing that in the original gate, the electrons are effectively handed off to the next gate. By sending voltage pulses to the gates in groups of three, all the charge packets can be moved to the side.!

Once a column of charges has reached the edge of the chip, they are then read out in the perpendicular direction. These are then sequentially dumped onto a capacitor (small charge storage device), which changes its voltage. The voltage is detected and this number sent out as the signal that hit that one picture element, or pixel. This readout process can be slow, especially for large chips. While reading out, the chip is still busy and light sensitive, so no exposing can be done.

The charge of each x,y pixels is read out by passing it through an amplifier to produce a voltage (think of it as reading the voltage across a capacitor with the electrons stored on one plate). This voltage must then be converted into a digital signal using an Analogto-Digital (A-to-D) Converter. Each Digital Number (DN) represents a certain number of electrons, and is referred to as the Analog-to-Digital Unit (ADU). The number of electrons per ADU is the gain. Full Well - each diode has a maximum number of electrons it can hold before it is full or saturated. Charge may leak to neighboring pixels even before saturation is reached. Dynamic Range - the largest number that can be represented, compared to the smallest non-zero value (i.e. unity). This may be set by the full well capacity or by the AD converter. As these are digital devices that work in binary numbers (zero or one) they will always be: 2 n 1 where n is some integer (and the -1 is to get an ADU=0). We will come back to this topic later.

To speed up the process, it is possible to mask half the pixels with a reflective material, expose the naked ones, shift then under the masked pixels, and read them out while the next exposure begins. Such schemes are useful for video cameras, when rapid readout is essential. But the blockage of 50% of the incoming light renders them less suitable for low-light applications.!! Interline transfer CCD Screen transfer CCD

!! Upper Left 800 x 800 pixel CCD like the ones used on the cameras of the Galileo spacecraft. Upper Right, the same chip under 20x magnification. Lower Left, under 60x magnification. Here the structure of the individual pixels is becoming apparent. Lower Right: Jupiter s Great Red Spot from Galileo.!!

CCDs are black & white devices. To get color: Successive images, each through a different filter. OR Deposit colored filters right on the chip! (these images from Santa Barbara Instrument Group (SBIG))

HgCaTe Photovoltaics (currently the main 2-D near-ir detector) Often the sensitivity is given in terms of the Noise Equivalent Power (NEP) - that minimum detectable power (required to give a signal-to-noise ratio of 1) per square root of the bandwidth. The Detectivity D is the reciprocal of the NEP.

Sometimes InSb is Used (old versus new SpeX)

You need to select the appropriate detector for the job at hand

Bolometers Generally, these are meant to detect everything Uses a photoconductive material painted black Photons hitting it are absorbed, changing the temperature of the material, and its resistance. Usually operated at temperatures below 2 Kelvins. A commonly-used detector for far-ir photons. (these images from the Herschel Space Telescope web site)

Historical Note The original Palomar Sky Survey used the 48inch Samuel Oschin Schmidt, and photographic plates that were 14 inches on a side!! This covered much more of the sky - 6 degrees square - than any puny CCD could. However, the Quasar Equatorial Team (QUEST) used a mosaic of 112 CCDs to cover 4 degrees squared. This was the instrument astronomer Mike Brown and others used to discover the biggest objects in the solar system beyond the orbit of Neptune.